LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

Similar documents
Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED light engines LED linear / area

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

LED light engines LED linear / area

LED light engines LED linear / area

LED light engine / OLED LED linear / area

LED modules LED linear / area

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

LED modules LED linear / area

LED light engines LED linear / area

LED light engine / OLED LED compact

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

PHASED OUT. LED / OLED Light Engine LED linear / area. Umodule STARK LLE STARK LLE

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

LED light engines LED linear / area

LED modules LED linear / area

Tunable White LED linear / area

LED modules LED flexible. Module LLE FLEX G1 8mm EXC Modules LLE FLEX EXCITE

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

PHASED OUT. LED light engine / OLED LED compact. Umodule STARK DLE GEN2 CLASSIC STARK DLE

LED light engine / OLED LED compact. Umodule SLE G4 FASHION EXC

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

LED light engine / OLED LED compact. Umodule EOS P214-4 umodule EOS

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule STARK QLE CLASSIC EM umodule STARK QLE PHASED OUT. Ordering data.

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

LEDtape 800 TW Tunable White K CRI>90

U LED modules, converters and systems SIGNAGE. Uengine IMAGE SELECT

Applications. Shelf Lighting General Lighting Food Lighting Accent Lighting. Electrical Properties. Photometric Code. Typ.

Applications. Food Lighting Shelf Lighting Accent Lighting Ambient Lighting. Electrical Properties

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Applications. General Lighting Office Lighting Food Lighting Accent Lighting. Electrical Properties

Applications. Accent Lighting Ambient Lighting Display Lighting Shelf Lighting. Electrical Properties

Emergency lighting units EM LED Light Engines

Uengine COOL door for integration uengine COOL

Adjustable Adjustable Large Adjustable Deep. Deep / Deep IP44 / Deep Adjustable Deep Gold Deep Black Gold. IP44 Square Square Adjustable / 1-2-3

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

PRODUCT DESCRIPTION TECHNICAL DATA. Dimmable 0.1% - 100% Operating temperature - 30 C +45 C LED per meter 60 Pitch distance Cutting Length (C)

LED Driver Linear / area fixed output

Emergency lighting units EM powerled

LED control gear Compact fixed output

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Emergency lighting units EM powerled

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

VMU048012LP8xxA 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT

VMU080030LP8xxA 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT

VMU140055LP8xxC 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT

VMU240095LP8xxA 44 LP-LINEARHO DC MODULE, 2400mA MAX CURRENT

Fortimo LED Line High Flux

TMU140055CL8xxA 44 LINEARHO DC MODULE, 1400mA MAX CURRENT

TMU125050CL8xxA 22 LINEARHO DC MODULE, 1250mA MAX CURRENT

Fortimo LED Line Gen3

LED MODULES. Comfort COB Residential, Retail and Industrial Lighting COMFORT COB 500 LM TO 11,000 LM

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Emergency lighting units EM converterled

Typ. CRI. SDCM Module P [W]

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

TAT120015AC8XX TJT120015AC8XX

Emergency lighting units EM converterled

Experience bright and vivid colors

LED BUILT-IN MODULES. LUGA C 2016 HiCRI COB modules for lumen packages from 1500 to 4500 lm. LUGA C 2016 HiCRI 1500 LM TO 4500 LM.

Emergency lighting units EM powerled

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Emergency lighting units EM powerled

Experience bright and vivid colors

LED LINE SMD KIT GEN. 2

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

DATA SHEET. GLV92C50501 Series. Part of the simpleled Program v1 P-1

Emergency lighting units EM converterled

LED MODULES. LUGA Shop Gen. 5 Retail and Industrial Lighting LUGA SHOP GEN LM TO 20,000 LM LUGA SHOP GEN. 5 RETAIL AND INDUSTRIAL LIGHTING

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature

EVOLVE 50. LEDSpots for Retail Lighting HID and Halogen Replacement NEW MODULAR LED ENGINES FOR MULTIPLE OPTICS CONFIGURATIONS

LED BUILT-IN MODULES. LED Module Easy 28 Industrial and Hospitality Lighting EASY 28 3,500 LM TO 14,000 LM EASY 28 INDUSTRIAL AND HOSPITALITY LIGHTING

Emergency lighting units EM converterled

PrevaLED Linear Slim 3

15W (+/- 1W) 5.08" diameter x 0.75 H. Energy Star Luminaire CSD

BUILT-IN LED LIGHTING MODULES

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

THE PERFECT REPLACEMENT

Experience bright and vivid colors

LED MODULES. LUGA Shop Gen. 6 Retail and Industrial Lighting LUGA SHOP GEN LM TO 15,000 LM LUGA SHOP GEN. 6 RETAIL AND INDUSTRIAL LIGHTING

VR44-MU-xxx-8yy-xxxxA

PrevaLED Linear Slim 3

Transcription:

Module LLE PREMIUM CRI90 LLE PREMIUM Linear Tunable White LED module with 2,700 and 6,500 K SMT packages High module efficacy up to 122 lm/w at tp = 65 C High colour rendering index CRI > 90 Low tolerances for colour temperature (MacAdam 3) Low light current tolerances Excellent thermal management Ideal for linear and panel lights Long life-time: 50,000 hours 5-year guarantee È Standards, page 6 Colour temperatures and tolerances, page 9 www.tridonic.com 1

Module LLE PREMIUM CRI90 LLE PREMIUM Technical data Beam characteristic 120 Ambient temperature ta 3-25... +55 C tp rated 65 C tc 80 C Irated for LLE-24-280-700 125 ma Irated for LLE-24-280-1500 250 ma Imax for LLE-24-280-700 150 ma Imax for LLE-24-280-1500 300 ma Max. DC forward current for LLE-24-280-700 165 ma Max. DC forward current for LLE-24-280-1500 330 ma Max. permissible LF current ripple for LLE-24-280-700 180 ma Max. permissible LF current ripple for LLE-24-280-1500 360 ma Max. permissible peak current for LLE-24-280-700 240 ma / max. 10 ms Max. permissible peak current for LLE-24-280-1500 480 ma / max. 10 ms Max. working voltage for insulation 24 500 V Insulation test voltage 2 kv CTI of the printed circuit board 600 ESD classification severity level 4 Risk group (EN 62471:2008) 0 Classification acc. to IEC 62031 Built-in of protection IP00 2.5 3 279.5 125 125 Ø4 125 (77.25) Article numbercolour temperature Packaging carton (14.75) 24 Weight per pcs. LLE 24x280mm 700lm 927-965 PRE 89602732 2.700 / 6.500 K 210 pc(s). 0.029 kg LLE 24x280mm 1500lm 927-965 PRE 89602733 2.700 / 6.500 K 210 pc(s). 0.030 kg Specific technical data Channel Photometric Typ. luminous code flux at tp = 25 C 1 Typ. luminous flux at tp = 65 C 1 Typ. forward current 2 Min. forward voltage at tp = 65 C 2 Max. forward voltage at tp = 25 C 2 Typ. power consumption at tp = 65 C 2 Efficacy of the module at tp = 25 C Efficacy of the module at tp = 65 C LLE 24x280mm 700lm 927-965 PRE WW 827/349 670 lm 630 lm 125 ma 42.7 V 48.4 V 5.6 W 115 lm/w 113 lm/w 90 CW 865/349 720 lm 685 lm 125 ma 42.7 V 48.4 V 5.6 W 124 lm/w 122 lm/w 90 LLE 24x280mm 1500lm 927-965 PRE WW 827/349 1,330 lm 1,260 lm 250 ma 42.7 V 48.4 V 11.3 W 115 lm/w 113 lm/w 90 CW 865/349 1,440 lm 1,370 lm 250 ma 42.7 V 48.4 V 11.3 W 124 lm/w 122 lm/w 90 1 Tolerance range for optical data over the CCT range: ±5 %. 2 Tolerance range for electrical data: ±5 %. 3 CRI according to CIE 1931. 4 Mounted with non-conductive element like ACL CLIP 4.3mm. Colour rendering index CRI 3 www.tridonic.com 2

ACCES- SORIES LINEAR COVER SY LINEAR COVER / ENDCAP for LLE 24 Protection against direct touch for non-selv applications Mounting COVER: Fast snap on mounting on to LLE 24 with clips or plastic washers Mounting ENDCAP: Fast snap on mounting (sheet thickness 0.5 1.0 mm), for drilling hole 4 mm High transmission: transparent 94 %, semi-transparent 87 %, diffuse 76 % Linear cover made of PMMA Endcap made of Polycarbonat Tolerances LINEAR COVER: ± 1 mm for 597 mm length (ends finished), + 20 mm for 1,200 / 1,500 / 1,600 / 1,800 mm R17.5 R19.2 R10.5 legth (ends raw) 28.6±0.3 30.3 5 1.3±0.1 24+0.5/-0.4 1.8 12 20.0 38.4 6 35±0.5 Article number Colour Length Packaging carton Weight per pc. LINEAR COVER SY Transparent 1600mm 28000338 Transparent 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Frosted 1800mm 28000437 Semi-transparent 1,800 mm 12 pc(s). 0.308 kg LINEAR COVER SY Frosted 1600mm 28000339 Semi-transparent 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Frosted 1500mm 28000435 Semi-transparent 1,500 mm 12 pc(s). 0.244 kg LINEAR COVER SY Frosted 1200mm 28000422 Semi-transparent 1,200 mm 12 pc(s). 0.205 kg LINEAR COVER SY Frosted 597mm 28000340 Semi-transparent 597 mm 12 pc(s). 0.102 kg LINEAR COVER SY Diffuse 1800mm 28000438 Diffuse 1,800 mm 12 pc(s). 0.308 kg LINEAR COVER SY Diffuse 1600mm 28000341 Diffuse 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Diffuse 1500mm 28000436 Diffuse 1,500 mm 12 pc(s). 0.257 kg LINEAR COVER SY Diffuse 1200mm 28000434 Diffuse 1,200 mm 12 pc(s). 0.205 kg LINEAR COVER SY Diffuse 597mm 28000342 Diffuse 597 mm 12 pc(s). 0.102 kg www.tridonic.com 3

ACCES- SORIES ACL ENDCAP LLE24 PUSH-FIX ENDCAP for LLE 24 Fast snap on mounting (sheet thickness 0.5 1.0 mm), for drilling hole 4 mm Made of Polycarbonat 30.3 12 5 20.0 38.4 ACCES- SORIES LINEAR LENS Linear lens for LLE 24 Available in 60 and 90 light distribution Protection against direct touch for non-selv applications Fast snap on mounting on to LLE 24 with clips or plastic washers High transmission: semi-transparent 97 % Linear lense made of PMMA Tolerances: ± 20 mm for 1,600 mm legth (ends raw) 60 90 13.12 10.55 R19.2 R10.5 6 Article number Colour Packaging carton Weight per pc. ACL ENDCAP LLE24 PUSH-FIX 28001037 White 480 pc(s). 0.003 kg 24+0.2/-0.4 32±0.5 24+0.2/-0.4 32±0.5 Article number Colour Length Packaging carton Weight per pc. ACL LINEAR LENS 24x1200mm 60 28001428 Semi-transparent 1,200 mm 21 pc(s). 0.196 kg ACL LINEAR LENS 24x1200mm 90 28001429 Semi-transparent 1,200 mm 21 pc(s). 0.165 kg ACL LINEAR LENS 24x1600mm 60 28000953 Semi-transparent 1,600 mm 21 pc(s). 0.261 kg ACL LINEAR LENS 24x1600mm 90 28000955 Semi-transparent 1,600 mm 21 pc(s). 0.221 kg www.tridonic.com 4

ACCES- SORIES CLIP 4.3mm Clip for fixation of LED modules with 4.3 mm holes Fast snap on mounting (sheet thickness 0.5 1.0 mm) For drilling hole 4 mm Clip made of Polycarbonat 2.2±0.05 ø9 7.4 1.2 ø5.3 ø3.6 Article number Colour Packaging bag 1 Weight per pc. ACL CLIP 4.3mm PUSH-FIX 28001036 White 500 pc(s). 0.001 kg 1 Minimum sales quantity 500 pcs. www.tridonic.com 5

1. Standards EN 62031 EN 62471 EN 61347-1 EN 61547 EN 61000-4-6 1.1 Photometric code Key for photometric code, e. g. 930 / 349 1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit Luminous flux after 25% Code CRI McAdam after of the life-time (max.6000h) Colour temperature in McAdam 25% of the Code Luminous flux 7 70 79 initial life-time 7 70 % Kelvin x 100 8 80 89 (max.6000h) 8 80 % 9 90 9 90 % 2. Thermal details 2.1 tc point, ambient temperature and life-time The temperature at tp reference point is crucial for the light output and life-time of a LED product. For LLE a tp temperature of 65 C has to be complied in order to achieve an optimum between heat sink requirements, light output and life-time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. LLE PREMIUM 1,500 lm ta tp Forward current Rth, hs-a Cooling area 25 C 65 C 250 ma 5.1 K/W 131 cm² 35 C 65 C 250 ma 3.8 K/W 176 cm² 45 C 65 C 250 ma 2.5 K/W 268 cm² Notes The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. LED modules have to be insulated against the heat sink with a insulating thermal interface material. The LED modules must rest flat on the heat sink. 3. Installation / wiring 3.1 Electrical supply/choice of LED Driver LLE modules can be operated either from SELV LED Drivers or from LED Drivers with LV output voltage. LLE modules are basic isolated up to 500 V (mounted with non-conductive element like ACL CLIP 4.3mm) against ground and can be mounted directly on earthed metal parts of the luminaire. If the max. output voltage of the LED Driver (also against earth) is above 500 V, an additional isolation between LED module and heat sink is required (for example by isolated thermal pads) or by a suitable luminaire construction. At voltages > 60 V an additional protection against direct touch (test finger) to the light emitting side of the module has to be guaranteed. This is typically achieved by means of a non removable light distributor over the module. The tc and tp temperature of LED modules from Tridonic are measured at the same reference point. 2.2 Storage and humidity Storage temperature -30... +80 C Operation only in non condensing environment. Humidity during processing of the module should be between 30 to 70 %. 2.3 Thermal design and heat sink The rated life of LED products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the LLE will be greatly reduced or the LLE may be destroyed. Therefore the LLE needs to be mounted onto a heat sink. Tridonic s excellent thermal design for the LED products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life-time. 2.4 Heat sink values LLE PREMIUM 700 lm ta tp Forward current Rth, hs-a Cooling area 25 C 65 C 125 ma 9.8 K/W 68 cm² 35 C 65 C 125 ma 7.3 K/W 90 cm² 45 C 65 C 125 ma 4.8 K/W 135 cm² www.tridonic.com 6

3.2 Wiring Wiring diagram for switchdim and colourtemperature for LLE PREMIUM L N 220 240 V AC 0/50/60 Hz switchdim colourtemperature DA DA CS Udriver Wiring diagram for DALI for LLE PREMIUM L N 220 240 V AC 0/50/60 Hz DALI DA DA CS Udriver 3.3 Wiring type and cross section The wiring can be stranded or solid wires with a cross section of 0.2 to 0.75 mm². For the push-wire connection you have to strip the insulation (6 9 mm). wire preparation: 0.2 0.75 mm² 6 9 mm To remove the wires use a suitable tool (e.g. Microcon release pin) or through twist and pull. 3.4 Mounting instruction None of the components of the LLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing: 0.5 Nm. Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage. 3.5 EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection The LED modules are mounted onto a heat sink with 5 nonconductive elements (like ACL Clip 4.3 mm) per module. www.tridonic.com 7

4. Life-time 4.1 Life-time, lumen maintenance and failure rate The light output of an LED module decreases over the life-time, this is characterized with the L value. L70 means that the LED module will have 70 % of its initial luminous flux after the stated operating time. This value is always related to the number of operation hours and therefore defines the life-time of an LED module. As the L value is a statistical value the lumen maintenace may vary over the delivered LED modules. The B value defines the amount of modules which are below the specific L value, e.g. L70B10 means 10 % of the LED modules are below 70 % of the inital luminous flux, respectivly 90 % will be above 70 % of the initial value. In addition the percentage of failed modules (fatal failure) is characterized by the C value. The F value is the combination of the B and C value. That means for F degradation and complete failures are considered, e.g. L70F10 means 10 % of the LED modules may fail or be below 70 % of the initial luminous flux. Life-time declarations are informative and represent no warranty claim. 5. Photometric characteristics 5.1 Coordinates and tolerances according to CIE 1931 The specified colour coordinates are central measured by a current impulse with typical values of module and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the colour coordinates are ± 0.01. 3,000 K x0 y0 Centre 0.4325 0.3955 MacAdam ellipse: 3SDCM 0,4150 0,4050 0,4050 0,4000 0,3950 0,3900 4.2 Lumen maintenance for LLE PREMIUM Life-time declarations are informative and represent no warranty claim. LLE 24x280mm 700lm tp Forward temperature current L90 / B10 L90 / B50 L80 / B10 L80 / B50 L70 / B10 L70 / B50 55 C 36,000 h >50,000 h >50,000 h >50,000 h >50,000 h >50,000 h 125 ma 60 C 26,000 h >50,000 h 49,000 h >50,000 h >50,000 h >50,000 h 65 C 19,000 h 45,000 h 37,000 h >50,000 h >50,000 h >50,000 h 70 C 14,000 h 33,000 h 28,000 h 50,000 h 41,000 h >50,000 h 0,3850 0,3800 0,3750 0,4150 0,4200 0,4250 0,4300 0,4350 0,4400 0,4450 0,4500 0,4550 6,000 K x0 y0 Centre 0.3220 0.3330 MacAdam ellipse: 3SDCM 0,3550 LLE 24x280mm 1500lm tp Forward temperature current L90 / B10 L90 / B50 L80 / B10 L80 / B50 L70 / B10 L70 / B50 55 C 33,000 h >50,000 h >50,000 h >50,000 h >50,000 h >50,000 h 250 ma 60 C 24,000 h >50,000 h 45,000 h >50,000 h >50,000 h >50,000 h 65 C 18,000 h 41,000 h 34,000 h >50,000 h >50,000 h >50,000 h 70 C 13,000 h 30,000 h 26,000 h >50,000 h 39,000 h >50,000 h 0,3500 0,3450 0,3400 0,3350 0,3300 0,3250 0,3200 0,3150 0,3050 0,3100 0,3150 0,3200 0,3250 0,3300 0,3350 0,3400 0,3450 Colour spectrum at different colour temperatures 100 80 norm. Intensity [%] 60 40 20 3.000 K 4.000 K 6.000 K 0 380 420 460 500 540 580 620 660 700 740 780 Wavelength [nm] www.tridonic.com 8

5.2 Light distribution The optical design of the LLE product line ensures optimum homogenity for the light distribution. The colour temperature is measured integral over the complete module. To ensure an ideal mixture of colours and a homogenious light distribution a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between module and optic (typ. 6 cm) should be used. relative intensity Iv/Iv,max -10-20 100-30 -40 80-50 60-60 40 20 0 10 20 30 40 50 60 70 80-90 -100-80 -60-40 -20 0 20 40 60 80 100 90 The diagrams are based on statistic values. For further information see Design-in Guide, 3D data and photometric data on www.tridonic.com or on request. 5.3 Relative luminous flux vs. operating temperature rel. luminous flux [%] 100 95 90 85 6500 K 2700 K 80 25 30 35 40 45 50 55 60 65 70 75 80 operating temperature [ C] www.tridonic.com 9