Thermal Shut-Off I. OVERVIEW OF THERMAL SHUT-OFF VALVES

Similar documents
FEATURES FLP SERIES COMPLETE ASSEMBLIES FL SERIES PRODUCT CONFIGURATOR ONE VALVE DOES IT ALL

FEATURES ONE VALVE DOES IT ALL IDEAL FOR YOUR VALVE... OR OURS SURE STOP MOUNTING PLATE BALL OR BUTTERFLY VALVES

Fisher 2052 Diaphragm Rotary Actuator

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

Specification for FLP-series Fusible Link Packages

G Type Range of Actuators

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Fisher 3024C Diaphragm Actuator

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

IOM-CleanFLOW TM. CleanFLOW Series Ball Valves. SV F Flow Controls I N C O R P O R A T E D

Valtek Auxiliary Handwheels and Limit Stops

Model DFR 070/156/220 Rotary Actuator

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

F8/FB8 Series Ball Valves IOM-F8/FB8

NOAH ACTUATOR NA-SERIES MANUAL EMICO EUNHA MACHINERY INDUSTRIAL CO.,LTD.

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Manual Flushing. I nspection and Service

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

IOM Manual. IOM Manual. Series 76/77.

ONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

HQ Series ¼ Turn Electric Actuator

FRONT SEAT TRACK MOTOR. Removal

SD Bendix Manual Slack Adjusters DESCRIPTION ADJUSTING MECHANISM OPERATION

IOM FOR DYNATORQUE D-LOCK LOCKING DEVICE (DL TYPE)

AE Installation Operation & Maintenance Instructions

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

Fisher 1052 Size 70 Diaphragm Rotary Actuator

Series 820 AWWA Butterfly Valves

CALIPER BRAKE INSTALLATION AND MAINTENANCE MANUAL

Tech Note Truck 14 & 15.5 Twin Plate Cast Iron Type Installation Guidelines

Installation Operation Maintenance

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+

Brake System H TX, H2.0TXS [B475]; H TX [B466] Safety Precautions Maintenance and Repair

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

DISASSEMBLY. Transmission. 2. Remove the 4 clutch housing bolts. Separate the clutch housing from the transmission.

Installation Instructions

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Small Motorized Actuator

Installation Manual TWM Performance Short Shifter Subaru STi 2008+

Model DFR 026 Rotary Actuator

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

Embedded Rack Slide-out System

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

Butterfly Valve Type 57P

Sofa Slideout Assembly OWNER'S MANUAL. Rev: Page 1 Sofa Slideout Owners Manual

Fisher 657 Diaphragm Actuator Sizes and 87

Installation, Operation and Maintenance Manual

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

LC149 SERIES BUTTERFLY VALVE INSTALLATION, OPERATION, & MAINTENANCE

ONYX VALVE CO MODEL DAC-ADA Installation & Maintenance

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

MMR20. Instruction Manual for Operation & Maintenance. IB International. Ph:

Mixer Discharge Door Adjustment on models; 30, 42, 54, 81, 108, 135 mixers.

Fisher RSS Lined Globe Valve

ALLDATA Online Dodge Truck RAM 1500 Truck 2WD V6-3.7L VIN K - Steeri... Steering Column

Installation, Operation, and Maintenance Manual

Ford AOD-4R70W-AODE Cable Operated Shifter Installation Instructions

Disassembly and Assembly

B&W Trailer Hitches 1216 Hawaii Road / PO Box 186 Humboldt, KS P: F: " Split Lock Washers 8

Thank you for purchasing a Nelson RainTrain2.

ONYX VALVE CO MODEL CER and CEP Installation & Maintenance

Crestline Dampening System. Installation Instructions. A.B. Dick 350, 360, 375 Single & Dual Lever Machines. X /01 Rev-A

Butterfly valves Figure 56 Installation & Maintenance Instructions

KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York Telephone (607) Fax (607)

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

3 PHASE TESTER & MOTOR ROTATION TESTER

Model 3400 ATTENTION: WARNING

brochure PN

BETTIS ACTUATOR & CONTROLS SERVICE INSTRUCTIONS FIELD CONVERSION OF SPRING CARTRIDGE FAIL DIRECTION CLOCKWISE TO COUNTER-CLOCKWISE OR THE INVERSE

Tactical Laser Illuminator

Butterfly Valve Type 58 (PDCPD)

Installation Manual TWM Performance Short Shift Kit Stage 1 and Stage 2 MazdaSpeed 6

Fisher V270 Full-Bore Ball Control Valve

DeZURIK R1 POWERRAC ACTUATOR ON 1/2-3" PEC ECCENTRIC VALVES

TECHNICAL SERVICE MANUAL

PRODUCT OBSOLETED 4Q16

ONYX VALVE CO MODEL DEC Installation & Maintenance

CHAPTER 4 GOVERNORS AND LINKAGE

DeZURIK R1 AND R2 POWERRAC ACTUATORS

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

Installation Manual TWM Performance 2010 Mazda 3 short shifter 5 and 6 speed non-mazdaspeed

Installation Instructions HURST COMPETITION AND BILLET/PLUS SHIFTER Mustang w/5-speed Manual Transmission (GT only)

Spring Return and Double Acting Pneumatic Quarter-turn Actuators Operations Manual

Installation and Operation Manual

Transcription:

Thermal Shut-Off Valve I. OVERVIEW OF THERMAL SHUT-OFF VALVES BI-TORQ Valve Automation thermal shut-off valves are designed for flow shutoff protection in piping systems handling flammable gasses, liquids, solvents, toxic fluids, or any other potentially dangerous media. These fire control valves terminate flow in the event of fire, aiding in reducing fire intensity. In the event of fire, the fusible link separates, allowing the top mounted spring pack to drive an API 607 fire safe rated valve into a closed position. Fusible links are available in a range of temperature settings. The thermal shut-off valves also are available in a fail open position, ideal for a fire supression system in the event of a fire. The thermal shut-off valves you have received have been assembled and tested at our factory with attention to safety in mind. BI-TORQ Valve Automation uses high quality materials and tested engineering to ensure that this product will operate safely and reliably. Carefully read all instructions before handling in order to avoid injury to the operator or damage to the product. NOTE: Please refer to the attached assembly drawing FL-HD-0600 for parts identification and complete parts list. II. GENERAL SAFETY INSTRUCTIONS safety link (painted red) WARNING: Use extreme caution in handling the assembly because the spring pack is under full tension at all times. NOTE: Ball valves are shipped in the OPEN and ARMED position; butterfly valves are shipped in the CLOSED and ARMED postion. BALL VALVES ONLY: For shipping purposes, a safety link (#9) has been installed. This part is PAINTED RED. (see illustration 2.1) illustration 2.1 IMPORTANT: THE SAFETY LINK MUST BE REMOVED AND REPLACED WITH THE FUSIBLE LINK(S) AFTER THE VALVE HAS BEEN PUT IN LINE. IF SAFETY LINKS ARE NOT REMOVED, THE ASSEMBLY WILL NOT OPERATE CORRECTLY. The unit must be installed in a location with carefully maintained ambient temperatures. Installing the link in locations where high temperature fluctuations are possible (such as direct sunlight) is not recommended. Exposure to high ambient temperatures can cause the fusible links to break prematurely. (See chart 1 for link temperature ratings.)

III. INSTALLING FUSIBLE LINKS ON THE HT SERIES ASSEMBLY FOR ARMED ASSEMBLY USING BALL VALVES IMPORTANT: ASSEMBLIES WITH BALL VALVES ARE SHIPPED IN OPEN POSITION WITH RED SAFETY LINK(S) INSTALLED. UNITS ARE PROPERLY ARMED AND READY FOR INSTALLATION WHEN FUSIBLE LINKS ARE INSTALLED AND DECLUTCH GEAR IS DISENGAGED. NOTE: INSTALL VALVE IN PIPELINE BEFORE PROCEEDING! REQUIRED TOOLS: NONE 1. Engage declutchable manual override gear with declutch mechanism (#2). (Refer to drawing FL-HT-0600-1.4 for engaged/disengaged positions on declutch gear.) 2. Turn the declutch gear handwheel toward the open position (CCW) to relieve tension on the red safety link(s) (#9) and then remove link. CAUTION: Keep declutch in engaged illustration 3.1 positon while replacing safety links. 3. Secure fusible link(s) to retaining arm (#8) studs with 5/16 x 18 nuts until link is held firmly in position. CAUTION: HAND-TIGHTEN ONLY! Do not tighten nuts. Tightening will stress the links and could result in improper functioning. 4. Disengage declutch by turning handwheel clockwise (CW) until the declutch lever can easily move into disengaged position. DO NOT FORCE LEVER INTO POSITION. FOR ARMED ASSEMBLY USING BUTTERFLY VALVES IMPORTANT: ASSEMBLIES WITH HIGH PERFORMANCE BUTTERFLY VALVES ARE SHIPPED IN THE CLOSED POSITION AND MUST BE MOVED TO THE OPEN POSITION AND ARMED WITH FUSIBLE LINKS AFTER INSTALLATION. NOTE: INSTALL VALVE IN PIPELINE BEFORE PROCEEDING! REQUIRED TOOLS: NONE 1. The declutchable manual override gear is in the ENGAGED position. IMPORTANT: Leave the declutch in the engaged position while following the steps below. (Refer to drawing FL-HT-0600-1.4 for engaged/disengaged positions on declutch gear.) 2. Remove the nuts holding the red safety link (#9). CAUTION: Keep declutch in engaged positon while replacing safety links and fusible links. 3. While leaving the links off and keeping the declutch engaged, turn the declutch handwheel counter-clockwise (CCW) until the valve is fully open. (Refer to drawing FL-HT-0600-1.4 for engaged/disengaged positions on declutch gear.) 4. Move pivot arm (#11) into armed position (see drawing FL-HT-0600-1.1 and 1.2). 5. Place fusible links onto #8 link holding studs. IMPORTANT: DO NOT REINSTALL SAFETY LINK. 6. SLOWLY turn declutch handwheel clockwise (CW) toward the closed position until spring tension is held by fuses. 7. Disengage declutch by turning handwheel EITHER slightly clockwise (CW) or counter-clockwise (CCW) if necessary until the declutch handwheels can easily move into disengaged position. DO NOT FORCE handwheels INTO POSITION. 8. Unit is now armed. IMPORTANT: THE UNIT IS NOT ARMED UNTIL THE GEAR HAS BEEN DISENGAGED AFTER INSTALLATION OF LINKS. IF THE GEAR IS LEFT IN THE ENGAGED POSITION THE VALVE WILL NOT SPRING CLOSE.

IV. OPERATION The valve may be operated closed-open in the normal manner using the declutchable gear handwheel ONLY upon removal of the fusible links. IMPORTANT: FAILURE TO REMOVE FUSIBLE LINKS PRIOR TO OPERATING VALVE WILL DAMAGE THE ASSEMBLY. In order to remove fusible links, REVERSE installation instructions listed in section III. After removing fusible links, store in a safe place. DO NOT re-install red safety link. To engage the declutchable gear operator for manual operation, refer to section VI (operating declutchable manual override gear). The gear lever must always be returned to the DISENGAGED position after manually operating the valve and the links must be put back into place. CAUTION: Failure to return the gear to the disengaged position will lock the gear and valve into position, and the fusible link assembly will not function properly. IMPORTANT: The fusible links must be returned to their original position after manual operation. V. MAINTENANCE IMPORTANT: The fusible link manufacturer recommends annual replacement of link(s) as part of a regular maintenance schedule. Contact your local distributor or BI-TORQ Valve Automation for replacement links. Order by part number or temperature rating on old link. Replacement valve seats and seals subject to normal wear are available from your local distributor or BI-TORQ Valve Automation. The spring case and declutchable gear are lifetime lubricated and do not require maintenance. Disassembly of the spring case or gear will void any written or verbal warranties. WARNING: THE SPRING CASE CLOCKSPRING IS ALWAYS UNDER PRESSURE. DO NOT DISASSEMBLE SPRING PACK UNDER ANY CIRCUMSTANCES. DISASSEMBLY OF THE SPRING PACK COULD RESULT IN SERIOUS INJURY OR DEATH. LINK PART NUMBER FL-1: for size 10 Spring LINK YIELD MAXIMUM AMBIENT FL-1-165 165 F/74 C 135 F/57 C FL-1-212 212 F/100 C 185 F/82 C FL-1-286 286 F/138 C 253 F/123 C FL-1-360 360 F/182 C 330 F/166 C LINK PART NUMBER K-LINK: for size 12 Spring LINK YIELD MAXIMUM AMBIENT 110135 135 F/57 C 104 F/41 C 314165 165 F/74 C 135 F/57 C 110212 212 F/100 C 185 F/82 C 110280 280 F/138 C 253 F/123 C 110360 360 F/182 C 330 F/166 C Please consult factory for special order links

FL-HT-0600-1.1 7 9 8 11 4 12 TOP VIEW ARMED FL-HT-0600-1.2 2 5 6 3 1 TOP VIEW DISARMED FL-HT-0600-1.4 ASSEMBLY DRAWING FL-HT-0600 IMPORTANT: IMPROPER INSTALLATION OR ARMING OF FUSIBLE LINK ASSEMBLIES WILL VOID WARRANTY, AS WILL DISASSEMBLY OF THE PRODUCT WITHOUT PRIOR APPROVAL FROM FACTORY. 1 mounting bracket 2 declutch lever 7 8 spring pack keeper lever link holding studs SPRING PACK # OF LINKS PER UNIT LINK TYPE 109-020 6 FL-1 129-020 6 K-LINK 3 4 5 declutchable gear operator 9 fusible links (NOTE: see chart on left for link quantities per spring pack size) spring pack (109, or 129) 10 open position adjustment stops valve adapter 11 pivot arm 6 spring pack mounting plate (129 spring pack only) 12 mounting plate for fusible link

VI. OPERATING THE DECLUTCHABLE MANUAL OVERRIDE GEAR IMPORTANT: Make sure that the fusible links have been removed before attempting to operate the valve with the declutchable manual override. Use the following instructions to ENGAGE the declutchable manual override. 1. Using one hand, grab the override engagement handle, squeezing the bottom handle and top handle together. 2. With the handles still squeezed together, rotate the handle from its declutched position upward toward the spring pack mounting flange until the handle locking tabs are inline with their locking positions. NOTE: In some cases the override gear teeth will not mesh correctly when rotating the handle upward. If this occurs, rotate the override handwheel slightly to mesh the gears and then rotate the declutch handle upward. 3. Once the override handle is in its locked position, the override is ready to be used. Clockwise rotation of the override handwheel will produce clockwise rotation of the override output and valve. Conversely, counterclockwise rotation of the handwheel will produce counterclockwise rotation of the override output, and valve. Use the following instructions to DISENGAGE the declutchable manual override. Note: When the assembly is rearmed with the fusible links back in place, the the manual override must be returned to its declutched position. Reversing the procedure above will return the override to the declutched position. Make sure that the handle locking tabs are inserted into their locking position on the override housing. Leaving the declutch engaged will prohibit the spring return unit from cycling the valve to the closed position when the fusible links yield. Leaving the unit in the engaged position will prevent the unit from operating correctly, may cause damage to the override as well as drivers linkages, etc. and void the override warranty. IMPORTANT: The fusible links will have to be reinstalled and the declutch disengaged before the assembly is properly armed. The picture on the left shows the declutch operator in the disengaged to allow the spring pack to close the valve when the fusible links yielf. As shown, the handle arrangement is pinned in the down position. The handwheel should rotate freely in either the clockwise or counterclockwise directions without affecting the valve rotation. DISENGAGED ENGAGED The picture on the left shows the declutch in the override position, or engaged, for operating the valve manually. As shown, the handle arrangement is pinned in the up position for override. Rotation of the handwheel clockwise will rotate valve clockwise (generally closed direction); rotation of the handwheel counter-clockwise will rotate actuator counterclockwise (generally open). IMPORTANT: FUSIBLE LINKS MUST BE REMOVED BEFORE ATTEMPTING TO OPERATE THE VALVE WITH THE DECLUTCH.