MCM Cabinet. Specification Sheet E2F2 or E2C2 or E2T2 Joint distribution pedestal

Similar documents
MCM Cabinet. Specification sheet LX3 (LTC2) Joint distribution pedestal

MCM Bolt cap / Decorative cap Specification sheet CBX1

Levanto. details CLE17T4A

Paseo. Luminaire CE21T4UF Pole PA40 base cover BD11

Symphony DETAILS. IP66 EPA: 1.8 FT 2 Weight: 52 lbs - 24 kg

Morino DETAILS IP67. Contact factory for WIRELESS CONTROLS and further details REV. 5: 06/18. EPA: 1.8 FT 2 Weight: 35 lbs - 16 kg

CD20S2 DENVER. Luminaire. Optics. Sources Lamp 4K = High power LED, 4000K (neutral white) ±150K.

Levanto DETAILS. IP67 EPA: 0.96 FT 2 Weight: 35 lbs - 16 kg

Meridian DETAILS CA10T4A CA10T4D CA13T4A. IP66 EPA: 2.2 FT 2 Weight: 27 lbs - 12 kg

Campana DETAILS CN55P1A. IP67 EPA: 1.8 FT 2 Weight: 52 lbs - 24 kg CN55P1B

Domia DETAILS CY55P1A CY55T4 IP67

Park Avenue DETAILS. IP67 EPA: 1.8 FT 2 Weight: 45 lbs - 20 kg

CR17S1 CELESTE. Luminaire. Optics. Sources. Finish / Options 5mils/127microns polyester super durable powder coating.

ONTRAC WIRE MESH CABLE TRAY SYSTEM

Options. Pole and Arm. Suitable for wet locations

APPENDIX B: LISTS OF APPROVED MATERIALS

Historia DETAILS CY25P1A CY25T4B (FGC/FGF) IP66 CY25P1A (M222/WPB)

ROT6022, ROT6524, ROT6526

CG42T4 AUGUSTA. Luminaire. Optics. Sources Lamp 4K = High power LED 4000 K (neutral white) ± 150K.

Augusta POST-TOP. IP66 EPA: 2.2 FT 2 Weight: 48 lbs - 22 kg

215E. Operator and Parts Manual MM158

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

CN12P1A GCPO REV. 1: 12/16

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

Applications. Standard Materials

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Augusta POST-TOP. IP66 EPA: 2.2 FT 2 Weight: 48 lbs - 22 kg

Majesta DETAILS CO12P1A CO12P1B IP66 COM12P1A

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

CI/W_ C2 C2A CI/W_ C2 C2A

GRANITE ENCLOSURES MODEL NO. NPS Standard Features

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Three-Phase Pole Mounted Recloser

IR600 Infra-red Lamp

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

TECHNICAL SPECIFICATION CLIENT : MCM

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

INSTALLATION INSTRUCTIONS

Installation, Maintenance, and Operation Manual

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

ITT. Goulds Pumps 65L, 95L, 120L, 160L, 250L, 320L 6" Stainless Steel Submersible Pumps. Engineered for life B65-320L. Residential Water Systems

Sconce INSTALLATION INSTRUCTIONS P C

Requirements for Secondary Voltage Revenue Metering (750 V and less)

Quick Connection Panel (QCP) Installation Guide

PARTS CATALOG Brush Rover RM98(US) < Table of contents > Frame 1 Transmission 15. Handle 26 Front 29 Control 33 Cover 38 Seat 45 Engine 48

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Replacement Parts List

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Lighthouse Power Pedestals,

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Product Information Packet ECP84404T-4 75HP,1185RPM,3PH,60HZ,405T,A4072M,TEFC,F

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

Generator Fire Safety: Generator assemblies should be located outside the building.

TYPE BLT DISCONNECT SWITCHES

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Enclosed Cable System with Portable Lowering Tool for Drop Ceiling Mount * Manual System for Indoor and Outdoor Use.

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

PDX and PX Retrofit Series

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

RZT TWIN STICK HYDRO DRIVE 250 Z 44" & 50" SERIES 0

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

The ideal complement for commercial and retail spaces where users will appreciate classic interpretations of style and elegance. Kaleidoscope Series

Anatomy SILENE OUT 3455-KDB SILENE OUT SINGLE. Double machined K9 crystal Single machined K9 crystal glass glass w/ smooth exterior and interior

Cellwatch Electrical Installation

General Specifications for Lighthouse Power Pedestal

Pre-assembled plug connectors Product range overview

Method Of Procedure For Retrofitting ECS Power Systems (CC )


Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

LED Lamp. Halogen Lamp

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Contractors Guide Central Inverter System Installation

Operation & Service Manual INSTALLATION

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

PARTS ORDERING INFORMATION

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

EQUIPMENT INFORMATION SHEET REFRIGERATION - MEDIUM TEMP. Link to PDF file

StorSystem Adaptable Storage Solutions Incorporating Glide & Tilt

HALO H7ICAT. 6" RECESSED DOWNLIGHTING Incandescent

SURFACE TRACK (120/250V) SPECIFICATIONS

Designer Series. Blanket Warming Cabinet.

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

SUBMERSIBLE SECONDARY CONNECTORS

MOTOALLIANCE WINCH MOUNT

Undercounter Refrigeration Design Guide

Recreational Vehicle Park Electrical Products & Accessories

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

Product Group 10 Wheelchair accessories and Other wheelchair components 02/2014 MBL

Transcription:

Specification Sheet E2F2 or E2C2 or E2T2 Joint distribution pedestal Standards colors : BL1-TX (Black); BG3-TX (Blue green); FG2-TX (Forest green); OG1-TX (Olive green); JD2-TX (Jade green); BR1-TX (Bronze). Note: All paints are textured (TX) SECTION SPECIFICATION ----- TO BE COMPLETED BY INSTALLER AND VERIFIED BY ENGINEER Qty Base functions Voltage Lamp post Option Network connection Satellite conduits Color code and name Remarks ** Example: 0 E2CT - 12SF / CB / I - 2SC BL1-TX Black textured All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 1 de 8

Joint distribution pedestal / General The MCM Base is a device added at the bottom of a lamp post which allows for the connection of surrounding homes with power (120/240V) and telecom (Tel. + Cable TV) We may use the MCM Base for the following: - 120/240V connections (residential) up to 400A each (Hydro-Québec Standard B.41.21, drawing 10-6005 revision E); - telephone and cable TV connections (residential), - municipal protection devices (lighting) and other electrical or control devices. - the lamp posts to be installed on the JDP's must first be approved by MCM, see this list of certified suppliers: LUMEC, CYCLONE, BCL, SNOC, QUATTRO, STRESSCRETE, SDL LIGHTING and LUMCA. House side The MCM Base comprises two main parts: The cabinet and the sub-base (this specification sheet only concerns the cabinet) MCM Bolt Cap (optional) Overall dimensions (no bumper) : Height: 1416,5 mm (55,75") Dia.: 445 (17,5") at doors level Weight: approximately 180 kg (400 lb). Materials: Structure : steel 9,5 mm (3/8 "), Envelope : Cast aluminium (min. thickness 4 mm) Note: To get a stainless steel envelope (min. thickness 2 mm), please contact MCM. Finishes: Structure : epoxy primer and super durable 60 degrees luster polyester finish (Test 1500 hrs+); Envelope : epoxy primer and super durable polyester finish, either textured or smooth (res.: 2000 hrs) Choice of colors Installation: The cabinet is bolted on the sub-base using four threaded rods 19 mm diam.(3/4") galvanized (included with sub-base). An aluminium bumper completes this installation. A sealed temporary cover closes the top of the cabinet until the eventual installation of the lamp post above. Notes: Contact MCM for structural specifications enquiries. Bumpers have to be installed in the same axis as the hinges. Cabinet and sub-base fixture hardware is included. Street side See our website for more technical information: http://www.mcmintegration.com/en/documentation/ Patents: Canada # 2,266,151, # 2,449,194 / USA # 6,167,673 / Europe # 1,062,399. / TM & : MCM Integration 2017. MCM Integration 8585, boul. St-Laurent, bureau 220, Montréal, QC, H2P 2M9 Tel.: 514 481-9191 / Fax.: 514 274-0284 / www.mcmintegration.com All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 2 de 8

Specification Sheet E2F2 or E2C2 or E2T2 / Dimensions Top view Note : Boulons non inclus / Bolts not included Always refer to the installation procedure provided by the lamp post manufacturer. Always install the bolts with their heads facing up when a MCM Bolt Cap is installed. Front view Side view All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 3 de 8

Specification Sheet E2F2 or E2C2 or E2T2 / Components Item Description Qty Part number 28 Electrical section lock option MCM-C1 2 CDI-1005 29 Communication section lock option MCM-C1 6 CDI-1006 30 Label: «Hardware inside» 1 CDI-7204 Item Description Qty Part number 31 Label: «Street side» 1 CDI-7205 1 Eyebolt 7 Spaenaur 024-820 32 Peel back foam hinge side 2 P-1410 2 Grounding connection label 1 MCM-7206 33 Peel back foam lock side 2 P-1411 3 Main solid copper neutral bar 8 terminals 1 CDI-2000 or CDI-2004 34 Neoprene band ¼ 4 P-1532 4 Main solid copper grounding bar 6 terminals 1 CDI-2001 or CDI-2005 35 Hinge set for transition door 2 A-1301 / P-1309-1 5 Cable tie mount 4 Spaenaur 086-460 36 Hinge set for large door 8 A-1301 / P-1308 6 Black tie wrap 3/16 X 8 in. 4 Spaenaur 086-446 37 Hinge set for threshold door 4 A-1301 / P-1309-1 7 Stainless steel rod 14-20 X 306 mm 3 38 Door hook 4 P-1671 8 39 Assembled right threshold door 2 A-1530 9 Coupling nut 1/4 X 7/8 po. 3 Spaenaur 155-800 40 Assembled left threshold door 2 A-1540 10 Stainless steel rod 14-20 X 750 mm. 3 41 Threshold 4 A-1535 11 Patent label 1 CDI-7203 42 Bumper (2 halves) 1 P-1058 12 Pulling ring 4 CDI-7202 43 Right shelf 1 A-1685 13 Serial number label 1 CDI-7201 44 Left shelf 1 A-1686 14 Electrical diagram label 1 CDI-7300/02 46 Knock-out seal 1 CDI-4510 15 Grounding bar 4 terminals (telecom type) 2 CDI-2003 47 Structure 1 A-1103 16 Electrical section wire 610 mm. Bare wire no. 4 AWG 49 Threshold lock 4 P-1531 17 Cable section wire 935 mm. Bare wire no. 4 AWG 50 Skirt 4 P-1533 18 Transition section wire 815 mm. Bare wire no. 4 AWG 51 Fuse holder 120 Volts (with wire) 1 CDI-3100 19 Temporary steel cover (silicon sealed) 1 P-BORN-102 52 Fuse holder 240 Volts (with wire) 1 CDI-3101 20 Interface plates (2 half assembly) 1 P-1008 53 Fuse holder 120/240 Volts (with wire) 1 CDI-3101 21 Transition section door (universal) 2 A-1691 54 Fuse holder 120 Volts (wireless) 1 CDI-3102 22 Large door 2 A-1201 55 Fuse holder 240 Volts (wireless) 1 CDI-3103 23 Protective tip 1/4. 3 Spaenaur RB-192 56 Satellite conduit (optional) 2 CDI-4501,02,03 24 Stainless steel nut 1/4-20 8 57 Main removable partition 1 P-1032 25 Support 2 P-1729 58 Bumper Label 4 MCM-7410 26 Left XL door 1 A-1211 59 MCM Bolt Cap (2 halves) (optional) 1 P-1028 27 Right XL door 1 A-1212 60 Decorative cap screw cover (optional) 1 P-1029 All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 4 de 8

Specification Sheet E2F2 or E2C2 or E2T2 / Exterior 44 35 House side 43 45 38 58 33 46 47 32 36 40 37 Street side 42 49 34 50 41 58 39 57 All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 5 de 8

Borne MCM Specification Sheet E2F2 or E2C2 or E2T2 / Energy Section MCM Bolt cap without cover (optional) Decorative cap (optional) 56 15 House side 60 59 12 Energy section Optional satellite conduits 19 F2 Section (C2 ou T2) 20 1 30 3 Street side 22 21 29 4 2 28 House side 5 53 Standard Optional fuse-holders: # Voltage lamp. Pièce Note 0 No lamp post 1 120V 51 White wire connected and black wire free 2 240V 52 Black and red live wires not connected. 53 12 120V/240V 53 White wire connected, others not connected. 1SF 120V 54 No wires 14 12SF 36SF 120V/240V 347V/600V 55 No wires No wires White: Connected to the 7th terminal and tightened to 30 ft/lb. All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 6 de 8

M Specification Sheet E2F2 or E2C2 or E2T2 / Telecommunication Section 25 31 10 29 24 1 24 9 7 15 23 11 13 All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 7 de 8

Specification Sheet E2F2 or E2C2 or E2T2 / Grounding connection N.B. The wires connected to the ground and the neutral bar shall be tightened to 30 lb-pi. Energy Telephone / Cable 3 16 18 4 The surface under main grounding bar must be paint free and covered with conductive grease ref. Thomas/Betts Contax Cat. no. CTB8 indicates connection to the neutral bar (from top). indicates connection to the main grounding bar. 17 Connected on 4th terminal Approx. 610 mm. of bare wire no. 4 AWG is required to connect the main ground bar Item 16 Item 17 Item 18 Approx 935 mm.of bare wire no. 4 AWG is required to connect the main ground bar to the to the neutral bar. cable ground bar. 30 mm. 8 100 mm 30 mm. 50 mm.. no. 4 wire 30 mm. 4 5 lug no. 4 wire 180mm. lug 50 mm. 250 mm. 250mm. 200 mm. Connected 270 mm. to 4th terminal 135 mm. 785 mm. 20 mm. 30 mm. Approx. 853 mm. of bare wire no. 4 AWG is required to connect the main ground bar to the transition section ground bar. 3 All rights reserved MCM Integration 2017. TM: Trademark used by MCM Integration. This specification sheet may vary from the actual product and may change without prior notice. 8 de 8