CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Similar documents
CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

cgm.3 2 ry Distribution Switchgear

CPG.0 Single busbar gas-insulated cubicles

cgm.3 system Fully SF6 gas insulated medium voltage switchgear up to 40.5 kv in accordance with IEC Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CGMCOSMOS-2LV. MEDIUM-VOLTAGE SF 6 GAS-INSULATED RING MAIN UNIT UP TO 12 kv LIB

CGM.3 System. Medium Voltage SF 6 gas-insulated cubicles up to 38 kv according to IEEE and CSA standards

cgm.3 Reliable innovation. Personal solutions. Modular, compact system (RMU) with full gas insulation

CGM.3 Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

CBGS-0. Medium voltage distribution

cpg.0 & cpg.1 Reliable innovation. Personal solutions. Single and double busbar panel type GIS system

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

cpg.0 Reliable innovation. Personal solutions. Family of GIS metal-enclosed switchgear assemblies

cpg.0 GIS-type medium-voltage switchgear with full insulation in SF 6 gas, up to 40.5 kv in accordance with IEC Standards

ga-gae630 2 ry Distribution Switchgear

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

NXPLUS C Single busbar. Maintenance-free for lifetime

Modular medium-voltage switchgear. NorMax

cpg.0 y cpg.1 Reliable innovation. Personal solutions. Families of single and double busbar GIS-type cubicles

Prefabricated transformer substations

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

8DJ. Maintenance-free for lifetime

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MESG 12 / 17.5 / 24 / 36 KV

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

ga / gae630 Reliable innovation. Personal solutions. Fully gas-insulated compact (RMU) and modular system

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Metal Clad Switchgears

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

ZX2 Gas-insulated medium voltage switchgear

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

ZX-Family Gas-insulated medium voltage switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Contents. The RM6 range

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Power IT Air Insulated Cubicle Uniswitch

UniGear. Technical Guide

Product catalogue. ABB AS, Power Products Division SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus 36

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Gas Insulated Metal-clad Switchgear, HMGS!

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

PIX-H Metal-clad switchgear up to 17.5kV

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Innovac SVS/08 - SVS/ kv modular switchgear

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

Air-insulated switchgear UniGear type ZS1

NEXT STEP B) SAFETY :

COMPACT SUBSTATION GUIDE

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Switchgear Type 8DJH 36 for Secondary

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Benefits, typical uses

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

XIRIA Green, Smart, Compact solution

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

36kV Gas Insulated Medium Voltage Switchgear

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

Metal Clad Air Insulated Switchgear

SF6 Gas-Insulated Metal Enclosed Switchgear

Adak Behin Niroo. co.com

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Medium Voltage Metal-Enclosed Switches

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

voltage switchgear ZX ABB ZX Family 1

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

HD4. Gas insulated MV circuit-breakers kv A ka

Unitole UP kv Primary substations Motor control centres

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Medium Voltage Metal-Enclosed Switches

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

B kv T&D GAS INSULATED SWITCHGEAR

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

Medium-Voltage Switchgear and Switches

Transcription:

MV Switchgear for CGMCOSMOS Fully gas insulated modular and compact (RMU)system Up to 24 kv Up to 27 kv mediumvoltage mediumvoltageag AG Langackerstrasse Langackerstrasse 25 25 CH CH 6330 6330 Cham Cham +41 +41 41 41 783 783 18 18 18 18 info@mediumvoltage.ch info@mediumvoltage.ch www.mediumvoltage.ch www.mediumvoltage.ch IEC Standards ANSI / IEEE Standards Reliable innovation. Personal solutions. www.ormazabal.com

CGMCOSMOS MV Switchgear for CGMCOSMOS-2LV Circuit-breaker protection and feeder functions New 2013! Compact cubicle (RMU) with two feeder functions and one vacuum circuit breaker protection function in a single gas tank. Extensibility: Right, left, both sides or none. Electrical characteristics IEC L V Rated voltage Ur [kv] 24 24 Rated frequency fr [Hz] 50 / 60 50 / 60 Rated current General busbar Ir [A] 400 / 630 400 / 630 Feeder Ir [A] 400 / 630 - Output to transformer Ir [A] - 250 Rated short-duration power frequency withstand voltage (1 min) phase-to-earth and between phases Ud [kv] 50 50 phase-to-earth and between phases Ud [kv] 60 60 Rated lightning impulse withstand voltage Phase-to-earth and between phases Up [kv] 125 125 Across isolating distance Up [kv] 145 145 Internal arc classification IAC AFL[R] 20* ka 1s / 25 ## ka 1 s Circuit-breaker IEC 62271-100 Rated short-time withstand current (main circuit) - Value tk = 1 s or 3 s Ik [ka] - 16 / 20* / 25 Peak value Ip [ka] - 40 / 52* / 62.5 Rated breaking capacity and making capacity - Mainly active current rated breaking capacity I1 [A] - 400 / 630 Short-circuit breaking capacity Isc [ka] - 16 / 20* / 25 Main switch making capacity (peak value) Ima [ka] - 40 / 52* / 62.5 Rated operating sequence - CO-3 min-co Circuit-breaker category - Mechanical endurance (operations-class) - 2000 (M2) Electrical endurance (class) - E2 Switch-disconnector IEC 62271-103 IEC 62271-102 Rated short-time withstand current (main circuit) - Value tk = 1 s or 3 s Ik [ka] 16 / 20* / 25 - Peak value Ip [ka] 40 / 52* / 62.5 - Mainly active current rated breaking capacity I1 400 / 630 - Main switch making capacity (peak value) Ima 40 / 52* / 62.5 - Switch-disconnector category - Mechanical endurance 1000-M1 (manual) / 5000-M2 (motor) - Cycles of operations (Short-circuit making current)- class 5-E3 - Disconnector and Earthing Switch IEC 62271-102 IEC 62271-102 Rated short-time withstand current (earthing circuit) Value tk = 1 s or 3 s Ik [ka] 16 / 20* / 25 16 / 20* / 25 Peak value Ip [ka] 40 / 52* / 62.5 40 / 52* / 62.5 Main switch making capacity (peak value) Ima [ka] 40 / 52* / 62.5 40 / 52* / 62.5 Earthing switch Category Mechanical endurance 2000-M1 2000-M1 Cycles of operations (Short-circuit making current)- class 5-E2 5-E2 * Tests conducted at 21 ka / 52.5 ka. ## Consult availability Applications RMU which includes the features of the feeder and circuit breaker cubicles. 28

MV Switchgear for CGMCOSMOS Configuration Cubicle Internal arc IAC AFLR 20 ka 1s 25 ka 1 s* 1740 mm height cubicle 1300 mm height cubicle (*) Consult availability Gas tank Stainless steel tank Frontal connection: Cable bushing Side connection: Two side extensibility Left extensibility / right blind Right extensibility / left blind Blind both sides Type of side connection: Female bushing Right Left Both Cone bushing Right Left Both Driving mechanism Actuating levers B type switch mechanism BM type motorized mechanism AV type manual mechanism Capacitive voltage presence indicator ekorvpis Capacitive voltage presence / absence indicator ekorivds Other capacitive voltage indicators Additional interlocks: Electrical interlocks Key lock interlocks Pad locks Cable compartment Screw type IEC bushings Cover for one cable connector per phase Pressure Relief Duct Rear chimney Control box Other voltage indicators Other protection relays Other metering and automation components Options CGMCOSMOS-2L2V* 2 feeders + 2 CB protection functions (*) Consult availability CGMCOSMOS-2LV (SANS type) According to SANS standards available. Consult www.ormazabal.com [mm] [in] Dimensions [mm] 420 kg 29

CGMCOSMOS MV Switchgear for Other components and accessories HRC Fuses Features: Horizontal fuse holders Front access Phase-independent compartments Protected within the gas tank Insulation and sealing against external agents (pollution, temperature changes, adverse weather conditions, including floods) Internal interlocks for a safe access to the fuse holder area Protection with fuses Protection against short circuits in the Medium Voltage network is made by means of the fuse protection functions. The fuse holder tubes reach a uniform temperature all along the tube when they are placed horizontally inside the gas tank. When the cover is closed, they are fully sealed against floods and external pollution. In accordance with the IEC 62271-105 standard, the switch-fuse combination may be either the associated or combined type. In the latter case, the tripping of each of the fuses is indicated on the front mimic diagram of the cubicle. Protection with fuses and tripping coil The combined switch-fuse option enables the opening of the switchdisconnector caused by an external signal, as for example that sent by the transformer thermostat in the event of overheating. Fuse selection according to IEC standards U r Network [kv] U r Fuse [kv] Rated transformer power without overload [kva] 25 50 75 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 Rated fuse current IEC 60282-1 [A] 10 6 / 12 6.3 10 16 16 20 20 25 31,5 40 50 63 63 80 100 160 200-13,5 10 / 24 6.3 6,3 10 16 16 20 20 25 31,5 40 50 63 63 80 100 - - 15 10 / 24 6.3 6,3 10 16 16 16 20 20 25 31,5 40 50 63 80 80 - - 20 10 / 24 6.3 6,3 6,3 10 16 16 16 20 20 25 31,5 40 50 50 63 80 125 Fuse selection according to IEEE standards U r Grid [kv] U r Fuse [kv] Rated Transformer Power without overload [kva] 25 50 75 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 Rated fuse current [A] 7.2 6 / 12 6.3 16 16 20 20 25 40 40 50 63 80 100 160 200 250 - - 12.5 10 / 24 6.3 6.3 16 16 16 20 20 25 31.5 40 50 63 80 80 125 - - 13.2 10 / 24 6.3 6.3 10 16 16 20 20 25 31.5 40 50 63 63 80 100 - - 14.4 10 / 24 6.3 6.3 10 16 16 16 20 20 25 40 40 50 63 80 80 - - 25 10 / 24 6.3 6.3 6.3 6.3 10 16 16 16 20 20 25 31.5 40 50 50 80 80 Remarks: Fuses recommended: SIBA brand with medium type striker, conforming to IEC 60282-1 (low power loss fuses). The values for combined fuses are given in blue. The fuse-switch assembly has been temperature-rise tested under normal service conditions in accordance with IEC 62271-1. A fuse holder carriage adapted for 292 mm (12.49 inches) 6 / 12 kv fuses is available. For ratings marked in bold the length is 442 mm (17.40 inches). If any of the fuses blow, we recommend changing all three. For overload conditions in the transformer or other brands of fuse, please consult Ormazabal. 32

MV Switchgear for CGMCOSMOS Indicators ekorsas acoustic alarm The ekorsas earthing (grounding) prevention acoustic alarm unit is an acoustic indicator that works in association with the earthing (grounding) switch shaft and the voltage presence indicator, ekorvpis. The alarm is activated when the earthing (grounding) switch actuation shaft access handle is operated while there is voltage in the cubicle's Medium Voltage incoming line. Then an acoustic alarm warns the operator that a short-circuit may be caused in the network if the operation is carried out, resulting in greater safety for individuals and equipment and the continuity of supply. Cable connections Bushings EN 50181 & IEEE 396 Manufactured in epoxy resin, they conform to the dielectric and partial discharge tests. There are three types: Plug-in up to 250 A (IEC) & 200 A (IEEE) Plug-in up to 400 A Screw-in up to 630 A (IEC) & 600 A (IEEE) Located in the cable compartment. Optionally, they may be placed on the side of the cubicles for direct supply to the main busbar. d ekorvpis voltage presence indicator ekorvpis is a self-powered indicator incorporated into the cubicles that displays the presence of voltage in the phases via three permanent light signals, designed in accordance with the IEC 62271-206 standard. It has easily accessible test points for performing the phase balance test. Ormazabal's ekorspc phase comparator and ekorivds voltage presence / absence detector can be supplied on request. Bushing Cable connectors Features: For single-core or three core cables. For dry cable or impregnated cable. Shielded or unshielded. Elbow or straight. Detailled information: Direct connection to the bushings located in the cable compartment or on the side via plug-in or screw-in connectors (rated current greater than 400 A or short-circuit current equal to or higher than 16 ka). 250 A plug-in connectors (straight or elbow type for rear exit of cable) in outputs to transformer (cable compartment) for fuse protection functions. Shielded connectors for circuit-breaker protection functions. Distance (d) CGMCOSMOS-L / RB [mm] (In) [310] (12.2) CGMCOSMOS-V [mm] (In) [500] (19.68) CGMCOSMOS-P Vertical CGMCOSMOS-P Bushing position Accessories Plug-in shunt in T Plug-in shunt in cross formation Insulating plugs Reducers Connection terminals Surge arresters For other types and values, please consult Ormazabal. 33

CGMCOSMOS MV Switchgear for Spare parts Metal enclosure Covers Operating levers Switch-disconnector general lever Connectivity Ormalink connecting set It includes the earthing bar, bolts and nuts, instructions and other elements required for the correct assembly of two modules Antireflex lever for BR mechanism Levers for Circuit Breaker End assembly kit It includes end plugs, metal cover to be mounted on the side of one cubicle, instructions and other elements required for assembly. Auxiliary profiles for uneven floors Fuse protection 12 kv fuse holder carriage 24 kv fuse holder carriage Carriage adaptor for 292 mm 6 / 12 kv fuses Lateral incoming box (CGMCOSMOS-CL) 34

MV Switchgear for CGMCOSMOS Handling, installation and after sales Handling Reduced size and weight make easier manipulation and installation tasks Safe cubicle delivery: Upright position on a pallet, wrapped in protective plastic with polystyrene corner pieces Inside buildings Easy handling with pallet jack (go through standard doors and elevators) Small dimensions: minimum room occupation Operation, extensibility and removal in reduced space No gas manipulation on site Optionally, installation on auxiliary profiles in case of uneven floors or to avoid cable trench works Handling methods (up to 5 functional unit assemblies): Lifting: Forklift truck or hand-operated pallet jack Alternative methods: rollers or rods underneath Raising: Slings & lifting beams Installation minimum distances Side wall (a) [100] (4) Ceiling (b) [500] (20) Front clearance (c) [500] (20) Rear wall (d) [>100] (>4)** ** Except for CGMCOSMOS-V (> 50 mm / 4 inches) and CGMCOSMOS-M (0 mm / inches). In case of rear chimney = 0 mm / inches The space required to extend the assembly with an additional cubicle is 150 mm / 5.90 inches plus the width of the new cubicle. b Ergonomic design for easy cubicle connection and floor fastening a d c For handling and installation instructions request the corresponding manuals to Ormazabal. 35

CGMCOSMOS MV Switchgear for Inside mobile or prefabricated transformer substations Turn-key solutions (fully assembling, testing and transportation from factory) Uniform quality Maximum trench dimensions for cubicles internal arc tested In gastank up to 20 ka 0.5s. Dry cable Function L, RB & RC P Cubicle height [1300] (51) [1740] (68) [1300] (51) [1740] (68) A F [285] (11) [590] (23) [390] (15) [590] (23) (1) D (2) D Single Core 3-core Single Core 3-core [400] (15) [600] (23) [500] (19) (R*) [300] (11)(R*) [350] (13) [600] (23) Ask [400](15) [250] (9.8) [500] (19) (R*) [300](11)(R*) [350](13) [250](9.8) V [1740] (68) [520](20) [590] (23) [500](19) [850](33) [850](33) (R*) For rear cable exit R = 500 mm (16.6 In) Ask Significant reduction of installation costs and time Possibility of cubicle on-site installation Wide range of Ormazabal s TS: Walk-in, underground, kiosk, compact Availability of having an operational Transformer Substation in short time IAC class + in gastank up to 20 ka 1 s. Dry cable Function Cubicle height A F (1) D (2) D L, RB & RC P [1300] (51) [1740] (68) [1300] (51) [1740] (68) [285] (11) [590] (23) [390] (15) [590] (23) Single Core 3-core Single Core 3-core [500](19) [300](11) Ask [500](19) [300](11) V [1740] (68) [520](20) [590] (23) [500](19) [850](33) [850](33) Ask Trench dimensions for metering cubicle The depth of the trench, suitable for all cable types, is [800 mm] (31 inch) Inside wind turbines Off-shore & On-shore wind farms Since 1995 supplying MV GIS cubicles for RES commercial generation Over 10 years of experience in the offshore wind sector The dimensions of the trench depend on the minimum curvatureradius of the cables used. The dimensions given below are for the largest trench. To dimension the trench with optimum proportions (minimum trench dimensions) for a particular type of cable, please consult Ormazabal. 36

MV Switchgear for CGMCOSMOS Commissioning and After Sales Services Technical assistance Engineering Procurement Contracting Installation Cubicle connection Earthing (grounding) Cable/busbar connection Commissioning Relay configuration Phase comparison Energizing Tests After sales support Maintenance Training Recycling and end-oflife As a part of its after sales services, Ormazabal provides electrical utilities and electrical end users recycling services for its switchgear. The Ormazabal production centres have introduced the corresponding environmental management systems, conforming to the requirements of the international ISO 14001 standard and endorsed by the Environmental Management Certificate AENOR CGM-00/38 among others. CGMCOSMOS system cubicles have been designed and manufactured in accordance with the requirements of international standard IEC 62271-200. By design, and depending on the models, they have a sealed compartment with SF 6 which allows full operation of the equipment throughout its service life, estimated at 30 years (IEC 62271-200). At the end of the product life cycle, the SF 6 gas content must not be released into the atmosphere. It is recovered and treated for reuse, in accordance with the instructions given in standards IEC 62271 303, IEC 60480 and the CIGRE 117 guide. Ormazabal will provide the additional information required to carry out this task correctly, out of respect for the safety of individuals and that of the environment. 37

mediumvoltageag Langackerstrasse 25 CH 6330 Cham +41 41 783 18 18 info@mediumvoltage.ch www.mediumvoltage.ch CA-100-EN-1305 CA-100-GB-1109