E.V.READY Specification for Installer Training Content

Similar documents
Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 ( )

NZQA registered unit standard version 1 Page 1 of 5

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply knowledge of electrical machines

EU-Mexico Free Trade Agreement EU TEXTUAL PROPOSAL

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

Major changes within the New 18 th Edition Wiring Regulations announced by The IET

Earthing Principles. Symmetra PX 250/500 kw

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

Technical Journal September 2012

WIRING MATTERS SEPTEMBER 2018

Demonstrate knowledge of electrical theory for Electrical Service Technician B

Notification of a Proposal to issue a Certification Memorandum. Approved Model List Changes

Certification Memorandum. Approved Model List Changes

HIGH-VOLTAGE BATTERIES DIAGNOSTICS & MAINTENANCE TRAINER

QUESTIONS & ANSWERS. Q1: Why does EASA not simply mandate accomplishment of a Service Bulletin (SB)?

National Certificate in Electricity Supply (Line Mechanic Distribution) (Level 4)

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018.

RSPO Supply Chain Certification. OCTOBER 17-18, 2016

NZQA registered unit standard version 1 Page 1 of 5. Apply and remove portable earths in an electricity supply system

EU RO Mutual Recognition Technical Requirements

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT

Implementation and development of standards for Lithium-ion energy storage technologies within the South African context

Level 4. Credits 61. Purpose. Replacement Information

Rule No. 1. Scope Definitions Periodicity of technical inspections Technical inspection Inspection requirements...

ANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS. Article 1. General Provisions

ESF on Fire Protection Proposed ESF on Fire Protection Engine attachment points applicable to Piston Engines EASA

FUSES. Safety through quality

Session Four Applying functional safety to machine interlock guards

Notice of Proposed Amendment Regular update of CS-25

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Instructionally Relevant Alternate Assessments for Students with Significant Cognitive Disabilities

NZQA registered unit standard version 1 Page 1 of 6

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

Offshore Application of the Flywheel Energy Storage. Final report

Subject: ACEA proposal for Euro 6 OBD and Euro 6 PN limit for gasoline direct injection engines.

ANNEX MOTOR VEHICLES AND EQUIPMENT AND PARTS THEREOF. Article 1. Definitions

The Impact of the 18 th edition (BS 7671:2018)

National Certificate in Electricity Supply (Distribution Faultman) (Level 4) with strands in Line Mechanic, and Electrician

COUNCIL OF THE EUROPEAN UNION. Brussels, 11 December /3/06 REV 3 ADD 1. Interinstitutional File: 2003/ 0153(COD) ENT 84 CODEC 561

COMMISSION REGULATION (EU) / of XXX

Breakout Session 1 Report-out presentations

EcoXpertTM Training & Certification Program

Electrical Energy Engineering Program EEE

SUBSTATION DESIGN TRAINING

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

RSPO Principles and Criteria Lead Auditor Course.

National Certificate in Electricity Supply (Sub Station Maintainer) (Level 4)

Academic Course Description

Grounding systems for power supply facilities

EVlink Parking EVF1 - EVW1

Economic and Social Council

OICA proposal for amendments to GRE/2013/3 (Regulation No. 10)

SOUTH AFRICAN NATIONAL STANDARD

Modifications to UN R131 AEBS for Heavy Vehicles

Guidelines for connection of generators:

Net +Plus Connection Code

POSITION PAPER Version 3.0

SYSTEM EARTHING & PROTECTIVE EARTHING

E-Mobility Trainings. Handling electric drives safely. TÜV SÜD Akademie GmbH

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

DIRECTIVE 2006/40/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

COMMISSION REGULATION (EU) / of XXX

COMMISSION REGULATION (EU) No /.. of XXX

MGE Galaxy 5500 Marine

(Text with EEA relevance)

FAA Part 27 Rotorcraft Safety Continuum for Systems & Equipment

TECHNICAL SPECIFICATION

Council of the European Union Brussels, 18 July 2014 (OR. en)

13 th Military Airworthiness Conference 25 th September 2013 EASA Presentation. Pascal Medal Head Of Certification Experts Department EASA

School Bus Driver Trainer Inservice

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

Section 1 Scope of application

Mode 2 Charging Testing and Certification for International Market Access

FAQ s. Are you AS/NZS Ready?

EVlink. Cluster Cabinet Including EVlink MS Energy Management and EVlink MS Supervision Recommendation Guide 04/2013.

KBA Kraftfahrt-Bundesamt

Training Program 2018 Where Education Meets Technology

A Concept Paper. Researchers: Dr. Benjamin G. Quito Dr. Villamor S. Quebral Dr. Edna C Aquino

Umatilla Electric Cooperative Net Metering Rules

ORION PLUS three-phase kVA

RESPONSE TO THE DEPARTMENT FOR TRANSPORT AND DRIVER AND VEHICLE STANDARDS AGENCY S CONSULTATION PAPER

Mode 2 Charging Testing and Certification for International Market Access

MINUTES. OF THE 1st MEETING TYPE-APPROVAL AUTHORITIES EXPERT GROUP - TAAEG * * *

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

ACEA RDE Cold Start. 30 th August 2016

Advanced Protective Relay Training

Renewable Energy Grid Integration and Distributed Generation Specialization Syllabus

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY NATIONAL CERTIFICATE MODULE: UNIT SPECIFICATION GENERAL INFORMATION. -Module Number Session

GT/TDINT100 Issue: 1 Date: SEP 1993 Page 1 of 11

OECD Standard Codes for the Official Testing of Agriculture and Forestry Tractors

ECE/RCTE/CONF/4/Add.1/Rev.2

SEVENTEENTH MEETING OF THE GRPE INFORMAL WORKING GROUP ON HEAVY DUTY HYBRIDS (HDH) Madrid, 08 to 09 April 2014 MINUTES OF THE MEETING

EarthSpark International 1616 H St. NW Suite 900 Washington, DC USA REQUEST FOR QUOTES REPAIRS TO THE LES ANGLAIS GRID. To Whom It May Concern:

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

ClearRoute Training Courses

76 th GRPE, 9-12 January 2018 Agenda item 3(a) OVC-HEV Certification according to R83/R101 Mode Selection for condition A and B

Economic and Social Council

SQA Advanced Unit specification: general information

Transcription:

E.V.READY Specification for Installer Training Content Document: TISN E.V.Ready 1.4D Ed 1.0 of 13/09/2016

Page: 2/2 Contents 1. Change tracking... 3 2. Background and purpose... 4 3. Training course structure... 5 3.1 Common core for all 3 levels Q1, Q2, Q3... 5 3.1.1 General information on electromobility... 5 3.1.2 Presentation of E.V.READY... 5 3.1.3 Evaluation before installation... 7 3.2 Implementation of requirements for the installation... 8 3.3 E.V.READY tool... 12 3.3.1 Presentation of the E.V.READY tool... 12 3.3.2 Implementation of the E.V.READY tool... 12 3.3.3 Control process with the E.V.READY tool... 12 3.4 Completing the self-checking form... 12 3.4.1 Presentation of the self-checking form... 12 3.4.2 How to complete the self-checking form... 12 4. Skills level of the E.V.READY trainer...13

Page: 3/3 1. Change tracking Reference Change Edition Date EVR87 Initial document 01 September 13, 2016

Page: 4/4 2. Background and purpose This document provides the specifications to be followed to design an "E.V.READY installer" training course. For this training course to be taken into account by the ASEFA certification body, the training material should address the issues presented in these specifications, while following the structure proposed in paragraph 3. The E.V.READY 1.4 repository introduced the concept of installer skills level based on various criteria listed below: - Performance and functionality level of the product to be installed - Field of intervention - Complexity of the installation These three levels are referred to as Q1, Q2 and Q3: (See EVR68 in Appendix 1) - Q1: base level - Q2: specialist level - Q3: expert level Training requirements will be adapted to the classification of the skills levels. This document presents the various themes and topics that the training course will develop, as well as the various stages of the course. It specifies the requirements for each skills level from Q1 to Q3. The grouping of the related training topics into modules will remain at the discretion of the training bodies. Finally, this training course should be sanctioned by an examination designed to assess the knowledge acquired by trainees at the end of the course.

Page: 5/5 3. Training course structure The training material will have to follow the structure shown below: The structure of the course is not required to follow the order of requirements as presented below: Each requirement must be referenced in the training material (traceability tracking). Presentation: For each requirement: - Display the requirement EVxx number - Display the requirement (official text of the technical requirements table) - Explain the purpose of the requirement for E.V.READY - Explain how the requirement should be implemented 3.1 Common core for all 3 levels Q1, Q2, Q3 3.1.1 General information on electromobility o Presentation of electromobility, economic, environmental and social challenges. o Rechargeable electric and hybrid vehicle. Presentation of the charging of the electric vehicle (mono or tri), the 4 charging modes, various types of plugs, charging power, charging time, EV/charging station communication, focus on the situation of the each concerned country. Reminder of the reference standards IEC 61851-1 Educational goal: - The installer must be able to provide the end customer with relevant information. 3.1.2 Presentation of E.V.READY o Presentation of E.V.READY / Transition from ZE-Ready to E.V.READY / E.V.READY to ZE-Ready prerequisites (since June 2015)

Page: 6/6 o Certification process for installers: registration with ASEFA, introduce ASEFA, installation company categorization according to E.V.READY, E.V.READY product categorization, classification of E.V.READY installers. o Presentation of the applicable E.V.READY technical requirements table, management of technical requirements upgrades. Educational goals: - Acquire a good overall knowledge of the E.V.READY certification process for products and installations. - The installer must also be able to explain to the end customer the contribution of the E.V.READY mark on an EV charging installation, as well as the reputation of E.V.READY in the market. - The installer must know the rights and duties attached to the use of the E.V.READY mark.

Page: 7/7 3.1.3 Evaluation before installation - Energy capacity of the installation (energy management, charging power vs. subscription), mono or tri, 400V or 230V, power connection and subscription. - Presence of an electric panel (main or secondary), available slot in the electric panel. EV7: - Presence of a ground connection, ground connection resistance measurement, value < 100 ohms - Checking of the interconnection of equipotential lines EV31: - Presence of a surge protector in the initial installation - Presence of a lightning rod - Complete an observation checklist - Compatibility of the recharging installation to be achieved with the legacy system: case analysis to develop during the course (minimum 3 cases). Educational goals: - Present to the installer the checks and verifications to be carried on the existing installation. - The installer will be able to complete a fact sheet on the condition of the installation before beginning the work.

Page: 8/8 3.2 Implementation of requirements for the installation EV3 (Q2, Q3): - If the additional isolation device is not placed in the charging station, it must be installed upstream and controlled by the charging station detection system. EV7, EV8 (Q1, Q2, Q3) : - Reminder on the TT and TN grounding diagram - Various methods for measuring the resistance of the grounding (loop measurement, 3 rods method) - Use of the E.V.READY tool (explanation of its implementation) - If ground measurement NOK: solutions to be applied Installation of an additional ground rod (introduce and explain the method) equipotential interconnection with the other ground connections / case of the upstream TN-C diagram (Q2 and Q3 levels) If the improvement measures do not reach a value <100 Ohm, intervention of a Q2 or Q3 level. EV9 (Q2, Q3): - The IT system is prohibited in direct use - Creation of a TN-S block with installation of an insulation transformer

Page: 9/9 EV10 (Q1, Q2, Q3): - Reminder of local regulations applicable to plugs. French example: NF-C 15100 article 555.1.8. EV12, EV17 (Q1, Q2, Q3): - Clarify that protection per charging point is necessary, a common RCD is possible. - A circuit breaker adapted by plug and wire diameter (e.g. 20A circuit breaker for a 16A plug) French example: reminder of the UTE C 15-722 guide EV14 (Q1, Q2, Q3) : - Reminder of the selection criteria in the case of an outdoor installation - Installation precaution as per the IK values (height of the installation) French example: E.V.READY more stringent in E.V.READY than the UTE C 15 722 guide EV22 (Q2, Q3): - Use of the installation's ground connection in each charging station + creation of an additional ground connection every 10 charging points with interconnection of all the ground connections to ensure equipotentiality. EV23 (Q2, Q3): - Explain the principle of self-resetting by local device for the RCD or circuit breaker in

Page: 10/10 case of default. - Remote resetting in case of default as per local regulations. French example: automatic resetting is prohibited EV29 (Q1, Q2, Q3) : - With a charging current between 8 and 10A the plug is not specific, present EV17 & EV29 Annex of the E.V.READY technical requirements table - >10A one dedicated line with a minimum wire at 2.5 mm 2 - The installer must check that the installed socket is E.V.READY compliant French example: refer to Annex LL of the NF C 61-314 standard. EV31 (Q1, Q2, Q3): - Implement local regulations regarding the need for a surge protector, and depending on the presence of a surge protector in the product or the installation. - Present the recommendations to be followed for the implementation and installation of a surge protector. French example: need for surge protector in accordance with: The keraunic area: present the map of France with keraunic areas (to be adapted for other countries) Presence of an overhead line Presence of a lightning rod Specific information on lightning strike if known. EV43 (Q1, Q2, Q3): - Measuring the neutral ground voltage

Page: 11/11 - Present the assumptions that lead to a neutral ground voltage >10V - Poor ground loop, in that case improve the grounding line - Rupture or improper grounding of the N-wire at the distribution transformer, in this case, inform the provider. To discriminate, one must measure the ground connection locally using the 3 rods method. - An imbalance between the 3 phases may generate voltage on the N-wire: Conduct an amperometric measurement of the voltages of each phase without consumption on the installation. - If >10V rms: how to identify the reasons and how to implement a correction - If unresolved: install an insulation transformer. Present the conditions and the installation diagram (upstream and downstream PE link). EV44, EV45 (Q1, Q2, Q3): - Explain what the harmonic disturbances mean and what their consequences are - How to assess the quality of the network and the harmonic distortion rate - How to implement a corrective solution in case of disturbances - How to use the E.V.READY tool to conduct that assessment EV49 (Q3): Installing an insulation transformer: - When to install an insulation transformer - How to install an insulation transformer and recreate a TN-S ground system on the secondary of the transformer

Page: 12/12 EV50 (Q3): Installation of an insulation transformer in the case of an excessive line impedance if the distribution transformer is too far from the installation. - Calculation of the voltage drops depending of the line impedance and the distance to the distribution transformer. EV51 (Q3): Installation of an insulation transformer if the N-wire is not distributed: - Check the presence of the N-wire 3.3 E.V.READY tool This tool is under development, but a description of its use to test the relevant requirements must be presented during the training course. 3.3.1 Presentation of the E.V.READY tool 3.3.2 Implementation of the E.V.READY tool 3.3.3 Control process with the E.V.READY tool - Requirements covered by the verification 3.4 Completing the self-checking form 3.4.1 Presentation of the self-checking form - Presentation of the E.V.READY self-checking form or an equivalent form. 3.4.2 How to complete the self-checking form - Conduct a case study to complete the self-checking form.

Page: 13/13 4. Skills level of the E.V.READY trainer This skills recognition is valid 5 years. The trainer should demonstrate to the ASEFA certifier that he has the following skills: - Technical and regulatory knowledge: Degree in the electrical field Study and design of Low Voltage electrical installations (proof of a minimum 5 days training) or equivalent experience (less than 3 years) - Training of trainers (less than 3 years) or recognition of a training experience in the electrical field. - Technical level of an E.V.READY trainer: Mastery of E.V.READY is paramount (EVREADY certification process, E.V.READY technical requirements table, use of the E.V.READY installation tool, case study) French additional specific requirements: - Electrical accreditation - initial - B1, B1V, B2, B2V, B2V tests, BC, BR electricians. Individual in charge of operations in LV: BE measurement, BE verification (proof of a minimum 5 days training) or equivalent level. - Electrical accreditation - initial electric vehicle (proof of a minimum 2 days training). Note: The ASEFA certification body reserves the right to conduct a "class background" audit during a training session to confirm the trainer's skills. The educational tool as a whole and the trainer's teaching methods will also be assessed.