Mechanical Seal Presentation April 22, 2009 Seattle WA.

Similar documents
CENTRIFUGAL PUMP AND SEAL (API Std. 610 and 682) Presented By Prakash Kumar ME(NSPL)

Hastelloy is a trademark of Hayes Int l, Inc., Aflas is a trademark of Asashi Glass Co., Ltd.

Installation Instructions

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

High Temperature Air-Cooled Hot Oil Pumps

High Temperature Air-Cooled Hot Oil Pumps

Series Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:

4500C Series Vortex Pumps

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

PUMPS STEAM TURBINES BUILDING & FIRE WASTEWATER SERVICE PUMP CLINIC 15 MECHANICAL SEAL DESIGN, OPERATION AND MAINTENANCE PROBLEMS

Installation Instructions

Installation Instructions

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

800 Series Mechanical Seals

PLACE FOR TITLE AUTHORS. Potassium Carbonate Pump Failure High Axial Movement due to Uncontrolled (unbalanced) forces.

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

1SV (e-sv) 60 Hz 3500 RPM

155 CARTRIDGE SINGLE SEAL

The ELM Series Slurry Pump Installation and Operating Manual

250L Dual Cartridge Seal

RS Multi-Stage, Ring Section Pumps

HEAVY DUTY CENTRIFUGAL PUMPS

1SV (e-sv) 50 Hz 2900 RPM

Quality fluid sealing solutions for industry.

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Bristol: A History & Future.

ABS Dry Installed Waste Water Pumps Series FR

PUMP TYPE Single stage, axially split volute casing pump with double entry radial impeller, for horizontal installation.

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Centrifugal End Suction Fire Pumps

DELTA STYLE 9500 CARTRIDGE SPLIT SEAL INSTALLATION INSTRUCTIONS INTRODUCTION:

Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Stainless Steel.

EN. 850 Filtrate Pumps. Technical Specification Pages

250L Cartridge Dual Seal

D51 D61 D71 D91 Series

340 Series Double Suction Split Case Pumps

TYPE 5625/5625P DUAL METAL BELLOWS CARTRIDGE SEAL

Installation Instructions

4400 TwinHybrid Gas Seal

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

Basic Hydraulic Features. Basic Mechanical Features

UNIVERSAL PRODUCT LINE: CAST IRON NON-JACKETED PUMPS SERIES DESCRIPTION TABLE OF CONTENTS RELATED PRODUCTS OPERATING RANGE:

PROCESS PUMPS MODEL V200 ANSI B73.2

Installation Instructions

NB /193 A-F2-A-BAQE

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INNOVATION EFFICIENCY QUALITY CRP-M. Centrifugal Pump with Permanent Magnetic Drive according to DIN EN 2858 and DIN EN ISO 15783

CRANE-DEMING VERTICAL IN-LINE INDUSTRIAL BULLETIN 3180 SECTION 38

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

F-Series Fire Fighting Pumps

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

Fire Protection. FP-XA End Suction

DESIGN CONSIDERATIONS FOR ROTATING UNIONS SEALING TECHNOLOGIES

Chemical Motor Pump Unit BN

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range1: Nominal Flow Rates:

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

Installation Instructions

Installation Instructions

VIKING SG SERIES SINGLE PUMPS (WITH SHAFT SEAL)

Verdermag Global Style series

Regenerative Turbine Pumps

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

PUMP INSTALLATION. Tim Sullivan, P.E. 12/1/2017 PUMP INSTALLATION PRESENTATION 1

CM1-6 A-R-I-E-AQQE F-A-A-N

Contents. Identification

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

Background. The function of wear rings. Wear Rings. Throat Bushing

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

Installation Instructions

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

150 Cartridge Single Seal

LIQUID-SPECIFIC PRODUCT LINE: STAINLESS STEEL VANE PUMPS PRODUCT DESCRIPTION SERIES OPERATING RANGE 1 NOMINAL FLOW RATES 2

Shipping volume [ft 3 ] 3 SQF-2 47 * 2.9 1" NPT Dimensions [in] L B S 3 SQF-3 49 * 2.9 1" NPT

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

Design Characteristics. Aplicaciones

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

Non-Metallic Seal-less Mag-Drive Pumps

NS Series Non Metallic End-Suction Centrifugal Pumps

280 Heavy Duty Cartridge Dual Seal

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Stainless Steel Vertical Multistage Pump CONTENTS

GUJARAT NARMADA VALLEY FERTILIZERS COMPANY LIMITED MTPA PAC PROJECT SECTION 6 ANNEXURE 4.7 SPARES, INSP AGENCY & DOCUMENTATION

The Practical Pumping Handbook

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

Transcription:

Mechanical Seal Presentation April 22, 2009 Seattle WA.

ANSI Process Pump Discharge Outlet Bearing Frame Casing/Volute Thrust Bearing Suction Inlet Shaft/Sleeve Impeller Radial Bearing

ANSI Process Pump Mechanical Seal Seal Gland Back Plate Seal Chamber (Stuffing Box)

Radial Movement Install the dial indicator as shown. Lift the shaft, or exert light pressure at the impeller end. If more than.003 of radial movement occurs, check bearing and bearing fits.

Axial Movement Install the dial indicator as shown. Use a soft hammer or mallet to lightly tap the end of the shaft. Total Indicated Readout (TIR) should not exceed.002

Run-out (Bent Shaft) Install the dial indicator as shown. Rotate the shaft, at the impeller end. If more than.003 of radial movement occurs, check bearing and bearing fits. Also check for bent shaft.

Install the dial indicator as shown, clamped to the shaft With the stuffing box cover bolted in place, rotate the shaft T.I.R should not exceed.003 Box Squareness

INTRODUCTION TO MECHANICAL SEALS

Sealing Points Single Cartridge Mechanical Seal

Sealing Points Point A Shaft Seal Point B Gland Seal Point C Rotary Face Point D Stat. Face Point E Primary Seal Point C Point E Point B Point A Point D

Creating a seal Three conditions absolutely must be met for the two faces to create a proper seal. 1) They must both be extremely flat. 2) Held parallel to each other, keeping the faces in contact with each other at all times. 3) Kept closed together by an external force such as springs.

Making the seal work Now that we have a static seal between the two faces, how do we make it a functional dynamic seal at 3600 rpm? In order to create a functional dynamic seal, there must be a clean lubricating fluid present between the seal faces. MECHANICAL SEALS ABSOLUTELY MUST HAVE A LIQUID LUBRICATING THE FACES!

Lubrication Mechanical seals absolutely must have adequate fluid between the faces for proper lubrication and operation! The lubricant is an ultra-thin, hydrodynamic film of fluid filling the space between the two sealing faces The lubricating fluid is forced between the sealing faces by product pressure A combination of closing force and centrifugal force keep the product from completely crossing the seal faces Lubrication determines whether a single- or double-seal is required in an application: Single-seals use product to lubricate the faces Double-seals use a barrier fluid to lubricate the faces

Lubrication Microscopic surface scratches produced during lapping provide a path for lubrication. The natural waviness of the seal faces created during fabrication provides a path for lubrication. Although the face is nearly perfectly flat, it is through these imperfections that the product is forced between the faces.

Outside Mounted Seal Rotary unit is installed OUTSIDE of the stuffing box. No metal parts come in contact with the product. Only low temp. and pressure. Factory pre-set spring load. Easy to install. Used in aquatic applications with shallow or no stuffing box.

Single Cartridge Seal ASI Style 724 Utilizes one set of sealing faces. Product is used to lubricate the faces. Suitable for a broad range of applications. Can be either component or cartridge style.

Single Cartridge Seal ASI Style 724 PPS Gland Insert PPS Sleeve Silicon Carbide Rotary Face Carbon Graphite Stationary Face

Available with Non-metallic Adapter Creates flush port. For equipment with shallow or no stuffing box. Flushed or non-flushed. Single Cartridge Seal ASI Style 724

Single Cartridge Seal ASI Style 724 As Fluid Enters the Seal Chamber, It Only Contacts: 1. PPS Sleeve 2. PPS Insert 3. Silicon Carbide Face 4. Carbon Face 5. O-Rings

Available Controls Many adverse environmental conditions can occur in a single application. Controlling these adverse conditions becomes critical to extending the life of the seal. The first step to sealing an adverse environment is selecting the proper style of seal. The next step is setting up the seal with the proper environmental controls.

Flush A clean fluid, external to the process, is introduced into the seal chamber, either through the seal gland or the chamber itself. To ensure that the flush flow goes into the seal chamber (and not out), flush supply pressure must be greater than seal chamber pressure. The product is diluted by the flush. A throat bushing is typically used in the bottom of the chamber to minimize the flush flow rate.

Flush

Suction Bypass A piped fluid connection between the seal chamber and the pump suction Net flow is out of the seal chamber and into the suction Reduces the pressure in the seal chamber Flow may be regulated, cooled, or heated as needed May be used with a throttle bushing

Suction Bypass

Discharge Bypass Net flow is into the seal chamber and out of the discharge. Increases the pressure in the seal chamber. Flow may be regulated, cooled, or heated May be used with a throttle bushing

Discharge Bypass

Programs available to Aquatic users 1. Quantity Discounts 2. Exchange Programs 3. Fixed Price Repairs 4. Failure Analysis

THANK YOU FOR YOUR TIME SEE YOU AT MOODY GARDENS IN 2010