Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Similar documents
W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Vacuum Circuit Breaker

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Benefits, typical uses

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

MESG 12 / 17.5 / 24 / 36 KV

ZX-Family Gas-insulated medium voltage switchgear

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

NXPLUS C Single busbar. Maintenance-free for lifetime

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Gas Insulated Metal-clad Switchgear, HMGS!

UniGear. Technical Guide

with Vacuum Circuit Breaker HAF

8DJ. Maintenance-free for lifetime

Metal Clad Switchgears

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Air-insulated switchgear UniGear type ZS1

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV


GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Gas Insulated Switchgear

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

PIX-H Metal-clad switchgear up to 17.5kV

CPG.0 Single busbar gas-insulated cubicles

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

STROM SICHER SCHALTEN

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

Power IT Air Insulated Cubicle Uniswitch

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Power Transmission and Distribution. NXPLUS C double busbar. The economical solution when replacing old systems

Extensible Unit - VCE2a

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

36kV Gas Insulated Medium Voltage Switchgear

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

the safe, reliable, and efficient choice for MV switchgear

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres

HB3 Generator Circuit-Breaker Switchgear

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

132/11 kv, 25 MVA MOBILE SUBSTATION

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Metal Clad Air Insulated Switchgear

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

ZX2 Gas-insulated medium voltage switchgear

ZX2.2 Gas-insulated medium voltage switchgear

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

3AP1 DTC for 145 and 245 kv

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Air-insulated medium-voltage secondary distribution switchgear

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

HIGS Highly Integrated Generator Circuit-Breaker Switchgear

Switchgear Type 8DJH 36 for Secondary

Medium Voltage Distribution PI 100. up to 24 kv Air-insulated circuit-breaker switchgear for primary distribution. System configuration

VB1-D Generator Circuit-Breaker Switchgear

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

CBGS-0. Medium voltage distribution

Medium-Voltage Switchgear OPERATING INSTRUCTIONS

UniSec Operation and maintenance manual

with Vacuum Circuit Breaker HAF

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

COMPACT SUBSTATION GUIDE

Switchgear Delta H2000 Medium voltage switchgear for primary distribution

Adak Behin Niroo. co.com

Modular medium-voltage switchgear. NorMax

Transcription:

Medium voltage switchgear type W rated voltage kv rated current 0 A

General The metal-encapsulated, air-insulated medium voltage switchgears, type W are for universal application. They range from compact ring cable switchgears up to complex power distribution switchgears. Tailored to meet the needs of public utility networks and power supply companies in industry and municipal buildings. These medium-voltage switchgears meet the user s specific requirements in full and ensure a satisfactory power distribution. The W standard types are available in three different dimensional sizes: W 0; w x d x h: 00 x 0 x 00 mm, W ; w x d x h: 0 x 0 x 00 mm, W 0; w x d x h: 00 x 0 x 00 mm. They are available as individual s or as a combined switchgear, where the equipment, sequence etc. can be determined by the customer. The switch s are type-tested in compliance with DIN VDE 00, Part, including the Pehla directive No.. Operating conditions The switch s of type W are installed in closed electrical operating areas which are only to be entered by skilled personnel and appropriately instructed persons. The equipment can be used at an altitude of up to 000 m above sea level. For installations above an altitude of 000 m the rated insulating level of the switchgear must be corrected accordingly. The switch s are designed for use under normal operating conditions in compliance with the standard DIN VDE 00, Part 000(IEC ). Technical standards The design of the air-insulated switch s corresponds to the specifications of the DIN VDE 00, Part. The resistance to accidental arcs of the switch s has been determined at ka and 0 ka; s, by and independent testing institute. The installed switchgear equipment is designed in compliance with DIN VDE 00, Part 000 (IEC ). Technical data rated voltage rated frequency rated lightning impulse withstand voltage rated short-time withstand voltage rated short-circuit duration rated current s with circuit breaker V-0- KUF rated current s with load disconnector H rated short-time current s with circuit breaker V-0- KUF rated short-time current s with load disconnector H rated peak current s with circuit breaker V-0- KUF rated peak current s with load disconnector H degree of protection kv 0 Hz kv kv s 0 A 0 A ka 0 ka ka 0 ka IP X Description of the W switch s Design The air-insulated medium-voltage switch s of type W with a width of 00 mm, 0 mm and 00 mm are metal-encapsulated. The switch frame is made of a screwed, hot-galvanized composite structure. The front of the switch s has a single-wing door of steel sheet with door hinge optionally on the right or left. A window of compound glass is inserted in the door. The cover in front of the bus bar compartment is either screwed on or designed as a door for the relay box positioned behind it. Each switch has a screwed on rear of galvanized sheet metal. Connecting cables are conducted into the switch s from below and are mounted on cross rails. The doors and covers of the switchgear are painted in structural paint (available in different colours according to the customer s request).

Equipment The switch s of type W are available in the following versions: Cable switch WK Transformer feeder WT Measuring switch WM Bus sectionaliser WÜ Circuit-breaker WL All switch s are partitioned off from to, in the bus bar area, by means of fibrousglass reinforced plastic plates with lead-in openings. Pressure relief can be in upward or downward direction. Switch s equipped with load-break switches can optionally be fitted with an earthing switch as well. Integrated in the circuit-breaker, type WL, there is also a bus disconnector. It is also possible to equip these s with a set of current transformers and voltage transformers as well as with an earthing switch. The optional interlocking of the equipment practically rules out any form of incorrect operation. All built-in switchgear equipment can be operated manually or via motor-operated mechanisms when the door is closed. The product program is completed by special measuring s which are fitted with current and voltage transformers. Earthing switches or spherical fixed points are available for earthing and shortcircuiting. An insulating protective plate can be inserted when the door is closed. It is possible to install appropriate surge voltage protectors in the, if required. W switch s optional - not possible * not possible with current or voltage transformer WK WT WM WÜ WL WÜL Switch s W 0 Cable Transformer feeder Measuring Bus section. Circuit breaker Circ. br. bus sect. Disconnector * * - - Load disconnector / H H EA / EK H SEA - circuit breaker EK / EA / SEA V.. KUF V.. KUF Earthing switch - Current transformer - Voltage transformer - - - WK WT WM WÜ WL WÜL Switch s W, W 0 Cable Transformer feeder Measuring Bus section. Circuit breaker Circ. br. bus sect. Disconnector - - - - Load disconnector / H H EA / EK H SEA - circuit breaker EK / EA / SEA V.. KUF V.. KUF Earthing switch - - Current transformer - Voltage transformer - - Weights Panel type Description Weight [kg] W - 0 W - W - 0 WK cable switch 0 WT transformer feeder 0 0 WÜ bus sectionaliser 00 0 WM measuring switch 0 0 WL circuit-breaker 0 0 Auxiliary equipment insulating protective plate in compliance with DIN VDE 0 part illumination, floor coverings capacitive voltage testing system in compliance with DIN VDE 0 part, short-circuit indicators additional locking systems with profile cylinder and lockable operating mechanisms

Type W 0 switch s Positions: Pressure relief plate Relay box Bus terminal Switch-disconnector H Withdraw able plate Current transformer Voltage transformer Circuit breaker Position indicator and actuation of load-break switch 0 Position indicator and actuation of disconnecting switch Position indicator and actuation of earthing switch Earthing switch Disconnecting switch HV-HBC fuse Cable terminal Type W 0 switch front view Cable with H EA/EK load discon. also possible with current and voltage transf. 0 0 Cable with H EA/EK load disconnector and disconnector Transformer feeder with H SEA load disconnector, also possible with current and voltage transformer Transformer feeder with H SEA load disconnector and disconnector

Bus sectionaliser with H EA / EK load disconnector Bus sectionaliser with H SEA load disconnector Measuring with current and voltage transformers 0 Measuring in longitudinal rails with current and voltage transformers side and front view Circuit-breaker with circuit breaker and disconnector

Type W and W 0 switch s Type W and W 0 switch front view Cable (bus sectionaliser ) with H EK / EA load disconnector Cable with H EK / EA load disconnector, current and voltage transformer Measuring with current and voltage transformer Measuring in longitudinal rails with current and voltage transformer Transformer feeder (bus sectionaliser ) with H SEA load disconnector

0 0 0 Circuit-breaker (V-0- KUF) with current transformer Circuit-breaker (V-0- F) with current and voltage transformer Circuit-breaker (V-0- KUF) (bus sectionaliser ), also possible with current transformer Specifications are subject to change without notice. DRIBO 0/0