Installation, Operation and Maintenance Manual

Similar documents
Installation, Operation and Maintenance Manual

Installation Operation Maintenance ADDENDUM

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

VSP SERIES Installation, Operation and Maintenance Manual

XP Peristaltic Pump Installation, Operation and Maintenance Manual. Fixed and Adjustable Models

Polymer Makedown Systems

READ ALL CAUTIONS CAREFULLY BEFORE INSTALLING PUMP SEE PAGE (4) SERIES 100/150 INSTRUCTION MANUAL P/N CDE: IM120 E/07

DC Variable Speed Drive Panel

Analog Condensate Monitor Instruction & Maintenance Manual

100 Gallon Skid Sprayer

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL

Vacuum Transport. Manual

Installation, Operation & Maintenance Supplement Instruction. Bulletin No.: IOMS-PUL PULSA Series 7120V DRIVE MOTOR INSTALLATION

Optional Accessories. Loss of Water Flow Switch. Loss of Polymer Flow Switch. Polymer Flow Transmitter. Remote Level Control. Stainless Steel Piping

Dosage Pumps - Installation Guide

50 Gallon Skid Sprayer

Model Due to continuing improvements, actual product may differ slightly from the product described herein.

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Air Compressor. Owner s Manual. Sonny's Enterprises, Inc Hiatus Road Tamarac, Florida v1

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual

Operating instructions Form no safety definitions

STAINLESS STEEL DETERGENT INJECTOR AW

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

ILCS EDGE System Installation Manual

150 Gallon 3- Point Hitch Sprayer

CRD610 Automatic Fitting Inserter

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

SAVE THESE INSTRUCTIONS

CRD600 Automatic Fitting Inserter

DIGITAL GLYCOL FEEDER

Corrosion Coupon Rack

Updated: October 2012

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

CONDENSER-NEEDLE COIL CLEANER OPERATING AND MAINTENANCE INSTRUCTIONS

EH Series High Viscosity Electronic Metering Pumps Instruction Manual

Manual. MicroTron. Series C. Installation Maintenance Repair Manual. Chemical Metering Pump

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

MicroTron Series C. Manual. Installation Maintenance Repair. Manual. Chemical Metering Pump


STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

M-3025CB-AV Fuel Pump

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

Installation, Operation, Repair and Parts Manual

Solenoid Chemical Metering Pump. Operating Manual

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

100 Gallon Skid Sprayer

TIN KNOCKER TK H1652 Hydraulic Shear

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

Heavy Duty Sprayer Owners Manual Model MS-O

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

Battery Capacity Analyzer

Agxcel GX12i Chemical Injection System

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Model C230 Pump Controller

Installation and Operation Manual

Installation and Operating Manual

An IDEX Water & Wastewater Business. pulsafeeder.com. Electronic Metering Pump

100 Gallon 4- Wheel Sprayer

1/2" AIR DRIVEN DIAPHRAGM PUMP

2 Model 826 Dispensing Valve User Guide

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

SUBMERSIBLE MINI-PUMP

Solar mosquito killer

AeroVironment Universal Solar Pump Controllers

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

QUALITY MISTING PUMPS

Walk-Behind Sprayer SL-80 & SL-80SS. Owner's Manual and Installation Instructions Original Instructions CAUTION

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

CONDUCTIVITY MONITOR AND CONTROLLER

50 Gordon Drive, Rockland, Maine sherplows.com. Walk-Behind Sprayer SS-120

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

OPERATORS MANUAL for Electric Pressure Washers

MODEL D-SBG Single Arm Barrier Gate Operator

SHOP PRO ST TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

Operating and Installation Instructions

General Installation Instructions for Valves and Gates

USER MANUAL. Tides La Mer Treatment Table Rev A 3/28/19. *all tables shown with optional accessories and/or finishes

SEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Asepsis 21 Delivery Unit

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

3 Phase Smart Controller

Voltmaster Centrifugal Trash Pumps

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

Cyclone Trash Separator

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

MODEL PS-4 DIGITAL PORTION SCALE

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

14.4 CORDLESS DRILL ASSEMBLY AND OPERATING INSTRUCTIONS

QUALITY MISTING PUMPS

Transcription:

Installation, Operation and Maintenance Manual Manual & Dry Contact Polymer Makedown Systems Manufacturers of Quality Pumps, Controls, and Systems Standard Product Operations 0 Airport Rd., Punta Gorda, FL 8 Tel: () -800 Tel: (800) - Fax: () -08 Fax: (800) -08 spotech@pulsa.com www.pulsafeeder.com -0-MPMDS-E Rev C

Pulsafeeder Factory Service Policy Should you experience a problem with your Polymer Makedown System, first consult the troubleshooting guide in this operation and maintenance manual, as well as the information in the manual for your Pulsatron pump. If the problem is not covered or cannot be solved, please contact your local Pulsafeeder Sales Representative or Distributor, or our Technical Services Department for further assistance. Trained technicians are available to diagnose your problem and arrange a solution. Solutions may include purchase of replacement parts or returning the unit to the factory for inspection and repair. All returns require a Return Authorization number to be issued by Pulsafeeder. Parts purchased to correct a warranty issue may be credited after an examination of original parts by Pulsafeeder. Warranty parts returned as defective which test good will be sent back freight collect. No credit will be issued on any replacement electronic parts. Any modifications or out-of-warranty repairs will be subject to bench fees and costs associated with replacement parts. Copyright 0 Pulsafeeder, Inc. All rights reserved. Information in this document is subject to change without notice. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or any means electronic or mechanical, including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of Pulsafeeder, Inc. -0-MPMDS-E Rev C ii

Table of Contents Topic Page Introduction... Safety... Skid Layout and Component Descriptions... Systems Overview... Supply Side... Process Side...8 Installation... Owner Installed Piping/Tubing, & Electrical... Initial System Start...0 Initial Prime... Polymer Makedown Process... -0-MPMDS-E Rev C iii

Introduction Congratulations With the Pulsafeeder Pre-Engineered Polymer Makedown System, you have the finest polymer makedown equipment platform available. This system includes the essential elements for successful installation and operation of your system(s). You are encouraged to: READ THIS MANUAL Pulsafeeder Pre-Engineered Polymer Makedown Systems are designed to support multi-pump installations for injection. The skid components (valves, gauges, interconnecting piping, etc.) are furnished to meet your specified operational requirements. The Dosing Pump(s), per se, may be furnished separately, so installation, operation and maintenance instructions for pump(s) are located elsewhere. -0-MPMDS-E Rev C Introduction Page

Safety Your safety is of the utmost concern to Pulsafeeder. Dosing pumps and systems can handle harsh or toxic chemicals and exposure can lead to serious injury or death. Always wear appropriate protective clothing (for example, safety glasses, gloves, coveralls, etc.) and follow safe handling procedures. Pay attention to what you re doing and note safety advisories where they are shown throughout this manual. Some examples of safety issues and precautions for Pulsafeeder Pre-Engineered Polymer Makedown Systems are: WARNING WARNING WARNING CAUTION CAUTION CAUTION Do NOT use Pulsafeeder Systems (or Pulsafeeder Pumps) for flammable liquids. Prior to working on any portion of the System, disconnect pump(s) from power supply, de-pressurize the system and drain chemicals from the lines. Inspect tubing regularly and replace as necessary. When inspecting tubing, wear protective clothing and safety glasses. If skid is exposed to sunlight, use UV-resistant tubing. Follow directions and warnings provided with chemicals from the chemical manufacturer. User/owner is responsible for determining chemical compatibility with chemical feed pump(s) and system components. Secure chemicals, metering pump(s) and system, making them inaccessible to children, pets and unauthorized personnel. WARNING CAUTION Always wear protective clothing including gloves and safety goggles when working on or near chemical metering pumps and systems. Installation and start-up of chemical dosing system will require both mechanical (plumbing) and electrical work. Only qualified and licensed plumbers and electricians should perform this. -0-MPMDS-E Rev C Safety Page

System Layout and Components Figure, below, illustrates a static mixer polymer makedown system with integrated control. This system can be used for two different chemicals or for redundant pump operation with one chemical. Your skid system may be less complex than this. Note the various components and their descriptions as they apply to your system. CAUTION Never remove the Tank Cover without removing power to the Polymer Makedown System first. The tank mixer blades (inside the tank) can cause serious harm or even death if allowed to come in contact with a person during operation. Control Panel Made-down Polymer Outlet Calibration Column Fill Valve Neat Polymer Injection Quill Static Mixer Back Pressure Valve Flow Indicator, Water Calibration Column Neat Polymer Pump Water Inlet Solenoid Valve Water Inlet, Left Side, Back or Front Pump Power Supply Calibration Column Supply Valve Neat Polymer Inlet Figure -0-MPMDS-E Rev C Skid Layout and Components Page

Systems Overview Manual Polymer Makedown Systems The Polymer Makedown System is designed to inject neat polymer into a clean water stream and to agitate this mixture through a static mixer causing the polymer strands to expand into a made-down aqueous solution. The solution is stored in the polymer solution day-tank and mixed occasionally with the rotary mixer located in the tank. The tank outlet is typically connected to the dosing pump(s) which inject the solution into the process application. The dosing pump(s) are not provided with the Polymer Makedown System and are not powered by the System. Supply Side Dosing chemicals are usually sourced from a barrel or tote container. The source must be located above the centerline of the neat polymer pump which is referred to as a flooded suction. Because Neat Polymer is a high viscosity fluid, the supply should never be located below the centerline of the pump(s) which is referred to as suction lift. Connections to and from the Neat Polymer Tank are most commonly made with flexible hose or tubing although they may be made with hard piping. The Neat Polymer Tank should be covered to prevent contamination. Flooded Suction This is the most trouble free type of installation. Since the Supply Line tubing is filled with chemical, priming is accomplished quickly and the chance of losing prime is reduced. Recommended for very low flow rate applications. e.g. ml/hr, or where pumping solutions such as sodium hypochlorite or hydrogen peroxide which can form air bubbles. Neat Polymer Tank Supply Line should gradually slope downward from the Solution Tank to the Skid Suction Connection. Pump It is strongly recommended to add a drain provision on the suction side to facilitate emptying and flushing of the system for maintenance. Supply Line Figure Flooded Suction -0-MPMDS-E Rev C Overview Page

Process side The Polymer Makedown System is not equipped with backflow prevention to protect against process fluid flowing back into the municipal water supply should the process pressure become greater than the water supply pressure. Please refer to all local, state and national codes for the proper backflow prevention requirements based on your type of installation. -0-MPMDS-E Rev C Overview Page 8

Installation Prior to attempting installation, familiarize yourself with the layout and components furnished with your Pulsafeeder Polymer Makedown System. These vary from system to system review the documentation supplied with your order. Inspect your system for damage which may have occurred during transit. If damage is discovered, immediately file a claim with the carrier and contact your Pulsafeeder distributor for any required replacement parts or components. All systems (and pumps) have been tested with water at the factory. CAUTION Some dosing chemicals will react with water, e.g., acids, polymers, etc. Check MSDS for the chemical to be handled. If adverse reaction with water is indicated, ensure that all portions of the skid piping, its components (and the pump) are free from water prior to filling skid system with chemical. Polymer Makedown Systems are to be floor-mounted only. Mounting holes are provided on the skid for floor mounting. Securely attach skid and the day-tank to the floor, in a position to prevent falling or tipping. Securely attach the provided ¾ x ½ diameter x 0 long tubing from the system s Made-down Polymer Outlet to the Day-tank s Made-down Polymer Inlet, on the hose barbs with the hose clamps provided; refer to Figure on page. It is best to cut this tubing to the desired length prior to installation, and be sure to support the tubing adequately over its length as its weight will increase when filled with made-down polymer. Installation area should provide ease of access to skid components (and pumps) and the area should be kept free of clutter to enable safe operation and maintenance. Note that pumps/motors are designed for ambient temperatures of 0 O F (0 O C) maximum. It is preferable that skid systems (and pumps) be located out of direct sunlight. If skid system is exposed to sunlight, provide protection for the pump/motor to prevent overheating and UV damage. CAUTION If skid is exposed to sunlight, use UV-resistant tubing. Owner-Installed Piping/Tubing The next series of steps are the connection of your piping/tubing which include the neat polymer supply line and tank outlet for made-down polymer supply to the system. These are your responsibility. WARNING Ensure that for all piping, tubing, fittings and other appurtenances, their materials are compatible with the liquid to be pumped and the design is suitable for the pressures and temperatures of the application. System design must ensure safety for operation and maintenance as well as for anyone who may be in proximity to the system. Failure to do so may result in damage to equipment, personal injury or death. -0-MPMDS-E Rev C Overview Page

Neat Polymer Supply Line This line connects the source of the neat polymer to the Pulsafeeder Polymer Makedown System. Please refer to Figure on page. The neat polymer source must be located above the centerline of the pump (flooded suction condition); ensure that the suction line has a gradual downward slope from the tank to the skid suction connection. The purpose of this is to prevent air pocket(s) in the suction line which could affect proper operation of the pump. Include whatever provisions you consider necessary to facilitate maintenance and operation such as isolation valve(s), drain and/or flush connections, etc., making sure that this sub-system enables SAFE OPERATION. Discharge Line This line connects the Pulsafeeder Polymer Makedown System to your served process. Please refer to Figure on page. If the injection point is below the dosing chemical source or if injecting into a low pressure area such as the suction of a pump, an anti-siphon/ back pressure valve should be located as close as possible to the injection point to prevent unwanted chemical feeding. Include whatever provisions you consider necessary to facilitate maintenance and operation such as isolation valve(s), drain and/or flush connections, etc., making sure that this sub-system enables SAFE OPERATION. Electrical Connection The control panel is provided with a standard plug for connection to V (+/-0%), 0A power to operate. Be sure that the selector switch is in the OFF position before power is connected. Manual System Dry Contact Control Option Initial Prime The neat polymer pump must be primed before it can function within the system. This will require an initial start of the pump. It is recommended that the system piping be filled with water before polymer is introduced to the system. Dry contact systems should have the Function selector switch in Manual.. Turn the Main Selector Switch to the Flush position (center) to initiate water flow.. Once water fills the system and begins to flow out of the system discharge, turn the Main Selector Switch to the OFF position to terminate water flow.. Open the Calibration Column Fill Valve; this aids in pump priming by providing a vent path to the calibration column, bypassing the Back Pressure Valve.. Depress the green Prime button to start the Neat Polymer Pump.. Observe polymer flow through the clear braided tubing connecting the pump discharge to the system piping; when present the pump is primed.. Release the Prime button to stop the Neat Polymer Pump.. Close the Calibration Column Fill Valve. 8. The system is now ready to operate. -0-MPMDS-E Rev C Overview Page 0

Polymer Makedown Process Manual System (without Dry-Contact input) Process Start This polymer makedown system utilizes a continuous makedown process. The makedown process is started by moving the Main Selector Switch to the Run position. This will open the Inlet Water Solenoid Valve and energize the Neat Polymer Injection Pump to add polymer to the water flow. The system will produce made-down polymer continuously while in the Run mode. System Adjustment Refer to Figure The Water Flow Meter can be adjusted to achieve the desired water flow rate by turning the adjustment knob until the indicator ball settles on the correct flow rate. Open the Calibration Column Fill Valve to divert neat polymer to the calibration column until full; close the fill valve. Simultaneously open the Calibration Column Supply Valve at the bottom of the column while closing the Neat Polymer Inlet Valve, and time the drawdown of polymer from the column for 0 seconds. Record the volume consumed and simultaneously close the Calibration Column Supply Valve at the bottom of the column while opening the Neat Polymer Inlet Valve. Calculate the actual flow rate of the pump and adjust to the desired rate. Repeat the calibration process to confirm. Adjust pump output as required and repeat calibration process to confirm adjustment. System Operation for Polymer Makedown Turn the Main Selector Switch to the Run position; leave in this position for the time required to produce the made-down polymer required. When complete, turn the Main Selector Switch to the Flush position for approximately minute. This allows incoming water flow to clean the injector nozzle and the static mixer of residual polymer. CAUTION: Failure to flush the system could result in significant fouling of the injector nozzle, static mixer and related piping as the made-down polymer solidifies over time before the next cycle. When the flush operation is complete, turn the Main Selector Switch to the Off position. -0-MPMDS-E Rev C Overview Page

Polymer Makedown Process Dry Contact input Manual System Process Start This polymer makedown system utilizes a continuous makedown process. The makedown process is started by moving the Main Selector Switch to the Run position and moving the Function Selector Switch to the Ext or External Input position. When the dry contact input circuit is closed, the Inlet Water Solenoid Valve will open and energize the Neat Polymer Injection Pump to add polymer to the water flow. The system will produce made-down polymer continuously while in the Run mode with the dry contact input closed. System Adjustment Refer to Figure The Water Flow Meter can be adjusted to achieve the desired water flow rate by turning the adjustment knob until the indicator ball settles on the correct flow rate. Open the Calibration Column Fill Valve to divert neat polymer to the calibration column until full; close the fill valve. Simultaneously open the Calibration Column Supply Valve at the bottom of the column while closing the Neat Polymer Inlet Valve, and time the drawdown of polymer from the column for 0 seconds. Record the volume consumed and simultaneously close the Calibration Column Supply Valve at the bottom of the column while opening the Neat Polymer Inlet Valve. Calculate the actual flow rate of the pump and adjust to the desired rate. Repeat the calibration process to confirm. Adjust pump output as required and repeat calibration process to confirm adjustment. System Operation for Polymer Makedown Turn the Function Selector Switch to the Ext position for External Input control, or to Man for manual on/off control. Turn the Main Selector Switch to the Run position; leave in this position to enable the external input for Ext mode, or to start the system if in Man mode. For Ext mode, when the dry contact input circuit is closed, the system will produce madedown polymer. When the dry contact input circuit opens, the system will turn off the Neat Polymer Injection Pump and leave the Inlet Water Solenoid Valve open for 0 more seconds to flush the system. The system will automatically restart when the circuit is closed again. -0-MPMDS-E Rev C Overview Page

If operating the system in manual mode, turn the Main Selector Switch to the Flush position for approximately 0 seconds; this allows incoming water flow to clean the injector nozzle and the static mixer of residual polymer. CAUTION: Failure to flush the system could result in significant fouling of the injector nozzle, static mixer and related piping as the made-down polymer solidifies over time before the next cycle. If in Man mode, when the flush operation is complete, turn the Main Selector Switch to the Off position. -0-MPMDS-E Rev C Overview Page

00- A B S- A B UPPER SLICE 0- D P NEMA -P Black White Green W Line A Line A Line A Line B Line B Line B 8 AWG Stranded E GND LUG L0 0 00 0 P CON P CON J CON J CON F 0VAC, SB,.A F 0VAC, SB,.A P CON P CON J CON J CON 0- S- 00- A B A B A B A B A B LOWER SLICE S- A B UPPER SLICE S- A B LOWER SLICE S- B 00-00- 0- SW SW PUSHBUTTON-DPST 00-0- D LOWER SLICE A B S- B 0- C UPPER SLICE C W LATCH LATCH AC POWER LEADS TO THE WATER SOLENOID Line A Line B Line A Line B Line A Line B 8 AWG Stranded LATCH - FPC LATCH - FPC B LBL LBL P-A NEMA -P Black White Green W Line A Line B Line A Line B Line A Line B 8 AWG Stranded B SW-LABEL SW-LABEL SWK PB P-B NEMA -P Black White Green A SW Actuator PUSHBUTTON Proprietary Data: This document discloses information and data in which Pulsafeeder has proprietary rights. The right to reproduce, use or disclose in whole or in part except by written permission is prohibited. Pulsafeeder, Inc. Standard Products Operation 0 Airport Road Punta Gorda, FL 8 http://www.pulsafeeder.com Title Manual PMDS MFG WIRING Size Document Number Rev B -8-0-: SD0 A Date: Monday, October 0, 0 Sheet of A

D P NEMA -P Black White Green W Line A Line B Line A Line B Line A Line B 8 AWG Stranded E GND LUG L0 00 00 00 P CON P CON J CON J CON F 0VAC, SB,.A F 0VAC, SB,.A 0- P CON P CON J CON J CON RED WHITE S- A A B B LEFT TOP SLICE S- A A B B LEFT BOTTOM SLICE S- A A B B CENTER TOP SLICE S- A A B B CENTER BOTTOM SLICE 00-0- 00-0- RED WHITE SW SW PUSHBUTTON-DPST 00-0- D 00- A B S- B 00- RIGHT TOP SLICE C B LATCH LATCH - FPC LBL LBL LATCH LATCH - FPC MANUAL/ EXTERNAL S- A B B LOWER SLICE S- A B B UPPER SLICE S- A A B B LOWER SLICE S- A A B B UPPER SLICE AC POWER LEADS TO THE WATER SOLENOID 00-0- 00-0- W Line A Line B Line A Line B Line A Line B 8 AWG Stranded L(HOT) S- A B B RIGHT BOTTOM SLICE OFF/FLUSH/ RUN TO PAGE TWO L(NEUTRAL) 0- TBC 0 WCA WCB J0 IBJA IBJB TBJMPR 8 IBJA IBJB WCA WCB TBB TBC 0 WCA WCB J IBJA IBJB TBJMPR 8 IBJA IBJB WCA WCB 00-8 0-8 C B TBB SWK SW-LABEL SW-LABEL PB P-A NEMA -P Black White Green W Line A Line B Line A Line B Line A Line B 8 AWG Stranded A SW Actuator PUSHBUTTON P-B NEMA -P Black White Green Proprietary Data: This document discloses information and data in which Pulsafeeder has proprietary rights. The right to reproduce, use or disclose in whole or in part except by written permission is prohibited. Pulsafeeder, Inc. Standard Products Operation 0 Airport Road Punta Gorda, FL 8 http://www.pulsafeeder.com Title SEMI-AUTOMATIC PMDS MFG WIRING Size Document Number Rev B A SD00 Date: Tuesday, January 0, 0 Sheet o f A

L 0- J8 TBC WCA IBJA WCB 0 IBJB 0- D L 00-00- TBJMPR IBJA IBJB 8 J WCA WCB TBJMPR TBB IBJA IBJB 0- WCA WCB TBD TBC WCA WCB 0 J IBJA IBJB TBJMPR IBJA IBJB 8 J WCA WCB TBJMPR TBB IBJA IBJB WCA WCB TBD 0-0 0-00- 00-0 8 LS 0 LS 8 RELAY DPDT 0-0- 0- (FROM PAGE ) 0-0- 00- (FROM PAGE ) TBC WCA WCB 0 J IBJA IBJB TBJMPR IBJA IBJB 8 WCA WCB TBB TBC WCA WCB 0 J IBJA IBJB TBJMPR IBJA IBJB 8 WCA WCB TBB 0- SOL_VLV 00- AC-L AC-L AC-N AC-N 0VAC WATER SOLENOID VALVE D RELAY DPDT C C 00-00- TBC WCA WCB 0 J IBJA IBJB 00- TBJMPR IBJA IBJB 8 LSA TBB WCA WCB CUSTOMER SUPPLIED CONTROL INPUT DRY CONTACT PSA 00- IN IN AC GROUND +VDC OUT TBC IN NEUTRAL LINE RETURN OUT WCA WCB 0 J 8- VAC, 0/0Hz to VDC, W 00- IBJA IBJB TBJMPR B IBJA IBJB 8 WCA WCB TBB SAME AS ON PAGE ONE B P-A NEMA -P Black White Green W Line A Line B Line A Line B Line A Line B 8 AWG Stranded P-B NEMA -P Black White Green A SAME AS ON PAGE ONE A Proprietary Data: This document discloses information and data in which Pulsafeeder has proprietary rights. The right to reproduce, use or disclose in whole or in part except by written permission is prohibited. Pulsafeeder, Inc. Standard Products Operation 0 Airport Road Punta Gorda, FL 8 http://www.pulsafeeder.com Title SEMI-AUTOMATIC PMDS MFG WIRING Size Document Number Rev C SD00 A Tuesday, January 0, 0 Date: Sheet o f