SUBMERSIBLE BASIN MIXER

Similar documents
ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

MODELS HPGF/HPGFH, HPGH/HPGHH

SUBMERSIBLE SEWAGE PUMPS

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

MODELS 4VC(X * ), 6VC(X * ), 4VE(X * ) AND 4RC(X * ) SUBMERSIBLE SOLIDS HANDLING PUMPS. *Used in Hazardous Locations Class I, Division 1, Groups C & D

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

MODELS WGL20, WGL20H and WGL20F

SUBMERSIBLE GRINDER PUMPS

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

S4HVX Shown. (Class I, Division 1, Groups C & D): FM

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

HPGB750/1000/1500. Submersible Grinder Pumps. Pump Installation and Service Manual

PUMP VAULT S.T.E.P. SYSTEM

MODELS S3S(D)/S4S(D) and SB3S(D)/SB4S(D)

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

MODEL S4F SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

(Class I, Division 1, Groups C & D): FM

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

HYDROMATIC. G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM. Pump Installation and Service Manual

SP40 Submersible Sewage Ejector Pump

MODEL HPG200 ADVANCED SUBMERSIBLE GRINDER PUMP INSTALLATION AND SERVICE MANUAL

RAIL SYSTEMS WITH CHECK VALVE

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

MYERS MODELS 4V AND 4VX

Installation and Service Manual SK50 Submersible Sewage Ejector Pump

SUBMERSIBLE GRINDER PUMP Models HPGF/HPGFH; HPGH/HPGHH

MYERS MODELS 4R AND 4RX

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

MYERS MODELS 4VC & 4VCX

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

MYERS MODELS 6VC & 6VCX

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps

Installation Manual. Q Series Quadplex Grinder Systems. Contents

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

MYERS MODELS 4RC AND 4RCX

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

Pump Installation and Service Manual HRS Hydromatic Retractable System

471 US Hwy 250 East, Ashland, Ohio PH: FX:

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

SPC-PANEL Simplex, Single Phase Pump Control Panel

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SHEF30 Submersible Sump/ Effluent Pump

2460 / 2472 / Series Simplex Grinder Systems

S4HVX Submersible Pump with Explosion-Proof Motor End (Class I, Division 1, Groups C & D): FM For use with product built with USEM motor.

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 1HP CENTRIFUGAL SUBMERSIBLE EFFLUENT PUMPS

Ion Technologies WC33 Submersible Sump Pump

MYERS 4VCDP. 4" Solids Handling

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Kompensator External Low Voltage Heating Cable System

(Class I, Division 1, Groups C & D): FM

GARDEN HOSE UTILITY PUMP

XLE100/150 Series Explosion-proof Submersible Sewage Pumps

SUBMERSIBLE SUMP PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

PRE-PLUMBED SEWAGE SYSTEM

SUBMERSIBLE SUMP PUMPS

ESE Series Cast Iron Sewage Pumps

StormPro BA Series Sump Pump

SUNC3000 / Item #40885

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

IMPORTANT SAFETY INSTRUCTIONS

OWNER S MANUAL Submersible Sewage Ejector Pumps

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Transcription:

MBM(X)20* SERIES 1150 AND 1750 RPM MODELS *For use in Hazardous Locations Class I, Division 1, Groups C & D SUBMERSIBLE BASIN MIXER INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part # 23833A688 2015 Pentair Ltd. 07/14/15

SAFETY WARNINGS This manual contains important information for the safe use of this product. Read this manual completely before using this product and refer to it often for continued safe product use. Failure to heed these warnings and follow the instructions in this manual may result in severe bodily injury or death, or substantial property damage. Do not throw away or lose this manual. Keep it in a safe place so that you may refer to it often. Do not wear loose clothing that can become entangled in the propeller or other moving parts. This mixer is designed to handle materials that could cause illness or disease through direct exposure. Wear adequate protective clothing when working on the mixer. To reduce risk of electrical shock, mixer must be properly grounded in accordance with the National Electrical Code and all applicable state and local codes and ordinances. Always disconnect the mixer from power source before handling or servicing. Any wiring to be done on mixers should be done by a qualified electrician. Never operate a mixer with a power cord that has frayed or brittle insulation. Never let cords or plug lie in water. Never handle connected power cords with wet hands. WARNING: Risk of electrical shock! Follow all local electrical and safety codes and ordinances as well as the most recent National Electric Code (NEC-ANSI/NFPA 70). All mixers have a ground wire that is connected to a screw in the metal motor housing. This wire goes to the receptacle or control box which must be connected to a good outside ground such as a metal water pipe or ground stake driven at least 8 feet into the ground. WARNING: Severe injury may result from contact with moving propeller. Keep clothing, hands, and feet away from propeller any time power is connected to the mixer. MIXERS Mixers build up heat and pressure during operation. Allow time for mixer to cool before handling or servicing. Only qualified personnel should install, operate or repair mixer. This mixer must not be used to mix flammable, combustible or hazardous liquids. Make sure lifting handles are securely fastened each time before lifting. Do not lift mixer by power cord. Do not exceed manufacturer s recommendation for maximum performance, as this could cause the motor to overheat. Always secure the mixer in its operating position so it cannot tip over, fall or slide. Do not use in swimming pools, decorative fountains or any installation where human contact with mixer fluid is common. Do not operate mixer without safety devices in place. IMPORTANT! Myers is not responsible for losses, injury or death resulting from a failure to observe these safety precautions, misuse or abuse of mixers or equipment. CALIFORNIA PROPOSITION 65 WARNING: This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. 2

MBM(X)20 32 21 31 14 12 26 11 19 13 23 36 24 18 7 17 6 1 33 20 11 29 28 35 38 SECTION A-A 34 27 23 25 37 16 9 13 5 A 8 15 B B 30 MBM(X)20 PARTS LIST FOR USE WITH REGAL BELOIT MOTORS Item Description Eng. No. Qty. 1 CAP 22407C607 1 2 SCREW DRIVE #6 045800011 8 3 SCREW SET 5/16-18 05013A027 2 4 PLUG PIPE 1/4 05022A092 2 5 SCREW MACHINE 10-24 x 3/8 05434A043 1 6 O-RING 05876A122 1 7 O-RING 05876A123 1 8 O-RING 05876A125 2 9 WASHER LOCK 06107A015 1 10 SCREW MACHINE 5/16-18 x 1 07597A017 2 11 RING RETAINING 12558A006 2 12 CONNECTOR BUTT 22-16 12672A002 2 13 SCREW HHC 5/16-18 x 1-1/4 19100A012 6 14 SCREW CAP 5/16 x 7/8 001780011 6 15 SCREW CAP 3/8-16 x 1-1/4 001010101 2 16 WASHER SPRING 19331A005 2 17 CAP UPPER BEARING 21570B100X 1 CAP UPPER BEARING (MBM20 ONLY) 21570B100 1 18 HOUSING MOTOR 21571D100X 1 HOUSING MOTOR (MBM20 ONLY) 21571D100 1 19 HOUSING UPPER SEAL 21574D100X 1 HOUSING UPPER SEAL (MBM20 ONLY) 21574D100 1 20 PLUG SPECIAL 1/2 HEX 21577A000 1 21 HOUSING LOWER SEAL 21578C100X 1 HOUSING LOWER SEAL (MBM20 ONLY) 21578C100 1 22 BRACKET MIXER 526033065 1 23 SEAL 7/8" 21576A010 2 24 BEARING BALL 08565A013 1 25 BEARING BALL 08565A018 1 26 ELECTRODE WITH RESISTOR 22578A003 1 ELECTRODE (MBM20 ONLY) 22578A004A 1 27 SCREW HHC 5/16-18 UNC x 1-3/4 001010111 2 TUBE PLASTIC (NOT SHOWN) 10649A102 2 FERRULE RUBBER.312 O.D. x.265 I.D. (NOT SHOWN) 22579A000 1 10 22 A SECTION B-B MBM(X)20 MOTOR PARTS LIST 2 3 4 Item Description 1750 RPM 1150 RPM 36 ROTOR/SHAFT 152260111 152270111 37 STATOR 152260031 152270031 38 CONNECTOR 12672A001 (3) 12672A001 (3) MBM(X)20 WET END PARTS LIST Item Description Eng. No. 28 SCREW CAP 5/16-18 001780041 29 WASHER PROPELLER 005190001 30 KEY 3/16 SQ. x.69 101020011 31 HOUSING LIP SEAL 134894002 32 LIP SEAL 152220001 33 PROPELLER 152120002 34 RING PROPELLER 27755A000 35 SPACER PROPELLER 27799A000 3

Never enter a sump chamber after sewage or effluent has been in basin. Sewage water can give off methane, hydrogen sulfide and other gases that are highly poisonous. For this reason, Myers recommends installing the MBM(X) mixer with a quick removal system. See installation drawings for suggested installation. HAZARDOUS LOCATION SERVICE These pumps are to be used for handling sewage, wastewater and storm water only. Do not use in other hazardous locations. These motors must be repaired and serviced only at authorized agency approved service centers or at the Myers factory. Any unauthorized field repair voids the warranty, the hazardous location rating, and agency approval. SPECIAL INSTRUCTIONS FOR THREE- PHASE MIXERS Do not remove cord and strain relief. Do not connect conduit to mixer. Three-phase mixers are always installed with control boxes having magnetic starters with overload protections. Do not try to run three-phase mixers directly across the line. To connect mixer, run wire from pump to bottom of control box or appropriate junction box suitable for enclosing splice connections. A hole must be cut into the control box for the wires. With power on control box off, connect green (ground) line to ground lug. Connect black (power) wires to power lead terminals. NOTE: For a typical CE style control box and not in a position to be pinched or shorted when door is closed. Before installing mixers check rotation of propeller to make sure mixer is connected correctly to magnetic starter. All mixer propellers either single or three-phase must turn counterclockwise when looking from propeller side. To check for proper rotation, lay mixer on side, using Hand position of H-O-A switch. Turn on and off fast so that coast of propeller can be seen. Never put hands or fingers on the propeller when power is connected. Interchange any two line leads at magnetic starter to change if rotation is incorrect. GENERAL DESCRIPTION AND APPLICATION Myers MBM(X) series basin mixers are used to break up crusts and solids that float at the top of a solids handling basin. The unit can also be used for mixing and stirring applications in industrial areas and waste management facilities. The mixers are available in two speeds 1150 and 1750 rpm. The integral stainless steel motor shaft is sealed by two mechanical seals with an oil chamber between the seals to provide lubrication for both seal faces. Two ball bearings are used to handle the loads. The upper bearing takes radial load, while the larger lower bearing handles both thrust and radial loads. Both bearings are permanently lubricated by the dielectric oil in the motor housing. The motor is fixed within the motor housing and is completely submerged in the dielectric oil for maximum heat transfer. The motor housing and seal chamber are completely sealed with O-rings located at mating part faces. MOTOR TYPE Motors are Regal Beloit/Marathon 3/4 partial, 48 frame 2 hp three-phase, 50 or 60 hertz, 1150 or 1750 rpm with class B insulation. The threephase pump motors require a magnetic starter with 3-leg overload protection. All motors have upper and lower ball bearings and all are oil-cooled and lubricated. INSTALLATION Warning: Basin or tank must be vented in accordance with local plumbing codes. TROUBLESHOOTING Below is a list of troubles and their probable causes: Insufficient mixing 1. Mixer orientation needs adjusted 2. Wrong rotation 3. Speed is too slow Mixer overloads motor 1. Wrong rotation 2. Specific gravity or viscosity of liquid is too high 3. Speed of motor is too high 4. Mixer is clogged 5. Defective bearings Mixer is noisy 1. Defective bearings 2. No axial clearance between propeller and seal housing If the cause of the trouble cannot be determined and corrected as outlined above, contact your nearest factory representative. 4

REPLACING SEALS Drain the oil in the seal chamber by removing the drain plug on the side of the unit. If it contains water, the lower seal has failed and should be replaced. The motor housing should be drained and the upper seal replaced if the lower seal has failed, since foreign material in the chamber may have damaged the upper seal. Remove the propeller after first removing center set screw at the end of the motor shaft. Using a pair of snap ring pliers, remove the snap ring that secures the lower seal. Remove the lower seal rotating elements by sliding the spring off the shaft. Then using two screwdrivers, slide the carbon assembly off by prying on the retaining ring. Loosen and remove the cap screws that hold on the seal housing, then remove the seal housing. Tap the stationary assembly out of the seal housing. Using the snap ring pliers again, remove the snap ring that secures the upper seal. Remove the spring retainer and spring from the shaft, and using the same method as used for the lower seal, remove the carbon seal assembly. Pry up on the seal/bearing plate. Remove the seal/ bearing plate until you have access to the seal sensor wire, then carefully pull the seal sensor wire off the seal probe which will allow the complete removal of the seal/bearing plate. The stationary portion of the seal from the seal/ bearing plate in the same manner as used for the lower stationary seal. After checking both of the O-rings, replace the seal bearing plate in the motor housing, making sure that the seal sensor wire has been reattached to the seal probe. Use O-ring lube to prevent cutting in assembly. NOTE: Do not reuse O-rings. They must be replaced if exposed during disassembly. Take the stationary portion of the new seal and lube the rubber material with good quality dielectric oil. Press the stationary portion of the new seal into the seal/bearing plate. CAUTION: Do not reuse old seal parts. Replace all parts with new. Mixing old and new parts could cause immediate seal failure. Using an agency approved dielectric oil, lube the rubber material on the carbon seal assembly and press it on the shaft. Place the spring and the seal retainer on the shaft as removed. Replace the snap ring. Carefully place the seal housing onto the seal bearing plate, replace the cap screws, and evenly tighten. Using a pressure gauge with a fill stem, pressurize the motor housing to no more than 7 psi with dried air and check for leaks. If after several minutes the gauge reads the same, the seal is good and you can continue with assembly. NOTE: It is normal to observe some air bubbles in the seal area initially as the seal seats. If bubbles do not stop within a few seconds, the seal is either not properly installed or is damaged. Follow the same procedure outlined above to install the lower seal assembly. Reassemble the propeller and propeller set screw into mixer. Refill motor housing and seal chamber with agency approved dielectric oil. Fill the motor housing so that the tops of the motor windings have been covered (2500 ml), but leave an air gap to allow for expansion of the oil. NOTE: Myers built control panels supply the correct circuitry for moisture and heat sensor connections. Failure to install the correct circuitry with proper connection would negate warranty and agency approval. REPLACING THE MOTOR STATOR If replacement of the stator is necessary, first follow the disassembly steps outlined in the previous sections of the manual. Remove the shaft rotor assembly from the motor housing, making note that a wave washer is used on top of the upper bearing. Place motor housing vertically on the bench and remove the cord grip. Carefully remove the power cord from the unit, making sure that the wires are not damaged. Clip the power cable leads, taking note of the wire connections, and then remove the power cable. Turn the motor housing over and remove the stator bolts from the stator, then remove the stator from the motor housing. Place new stator into the motor housing while pulling the new leads through the power cord opening in the motor housing. Replace the stator bolts and tighten. Replace the seal sensor wire along the side of the stator. 5

Attach the power cord to the stator leads and the sensor leads using the insulated butt connector. Once attached, carefully tuck the wires into the motor housing making sure that they will not come in contact with the rotor. Press the molded end of the power cord into chamber in motor housing. Apply a sealant to the threads on the body of the cord grip that will enter the motor housing, then slide onto the power cord and tighten snugly. Attach the cord grip nut onto the cord grip and snug. Examine the bearings on the shaft/rotor assembly. If when rotated they feel rough, replace. When reinstalling new bearings, press only on the inner ring of the bearing or damage may occur. Replace the wave washer into the upper bearing pocket in the motor housing, and then reinstall the rotor and shaft assembly. Follow the previously outlined steps to reassemble the mixer from this point. Always run mixer for a few seconds after assembly work to be sure all parts run smoothly before replacing it in the sump. Check again for correct rotation. Mixer should rotate counterclockwise when viewed from the propeller end. NOTE: When applying power, be sure the mixer is restrained from turning by holding the unit at the motor housing, or by clamping it in a holding fixture. 6

MOTOR WIRING DIAGRAMS NOTE: Probe test resistor is used on MBMX20 UL Hazardous Location only CONTROL POWER CONTROL POWER P1 P1 P2 HEAT SENSOR ON STATOR GROUND SCREW ELECTRODE T1 T2 T3 P2 HEAT SENSOR ON STATOR GROUND SCREW ELECTRODE T3 T9 T2 TB T1 T7 T4 T5 T6 PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY 200 VOLT THREE PHASE CONTROL STATOR STATOR PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY 230 VOLT THREE PHASE POWER P1 P2 HEAT SENSOR ON STATOR GROUND SCREW ELECTRODE T1 T2 T3 T4 T7 T5 TB T6 T9 STATOR PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY 460 VOLT THREE PHASE MOTOR ELECTRICAL DATA FULL LOAD AMPS 7 LOCKED ROTOR AMPS SPEED HP VOLTS PHASE FREQ KVA CODE SF SF AMPS LINE RESISTANCE RUN KW START KVA RUN KVA 1750 2 200 3 60 J 1.2 8 9.2 43.2 2.17 2.2 8.6 1.6 1750 2 230 3 60 J 1.2 7 8 37.6 2.17 2.2 8.6 1.6 1750 2 460 3 60 J 1.2 3.5 4 18.8 4.6 2.2 8.6 1.6 1750 2 575 3 60 1.2 2.8 3.2 1150 2 200 3 60 L 1 5.5 5.5 20.9 4.6 1.1 4.2 0.9 1150 2 230 3 60 L 1 4.8 4.8 18.14 4.6 1.1 4.2 0.9 1150 2 460 3 60 L 1 2.4 2.4 9.07 18.23 1.1 4.2 0.9

STANDARD LIMITED WARRANTY Pentair Myers warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first provided that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids. during the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units. Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of startup through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m. Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility. this limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/oem parts. Warranty Exclusions: PEntAiR MYERS MAKES no EXPRESS or implied WARRAntiES that EXtEnd beyond the description on the FACE hereof. PEntAiR MYERS SPECiFiCALLY disclaims the implied WARRAntiES of MERChAntAbiLitY And FitnESS FoR AnY PARtiCuLAR PuRPoSE. Liability Limitation: in no EVEnt ShALL PEntAiR MYERS be LiAbLE or RESPonSibLE FoR ConSEQuEntiAL, incidental or SPECiAL damages RESuLtinG FRoM or RELAtEd in AnY MAnnER to AnY PEntAiR MYERS PRoduCt or PARtS thereof. PERSonAL injury And/oR PRoPERtY damage MAY RESuLt FRoM improper installation. PEntAiR MYERS disclaims ALL LiAbiLitY, including LiAbiLitY under this WARRAntY, FoR improper installation. PEntAiR MYERS RECoMMEndS installation by PRoFESSionALS. Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. no warranties or representations at any time made by any representatives of Pentair Myers shall vary or expand the provision hereof. 1101 MYERS PARKWAY 490 PinEbuSh RoAd, unit #4 AShLAnd, ohio, usa 44805 CAMbRidGE, ontario, CAnAdA n1t 0A5 419-289-1144 800-363-PuMP WWW.FEMYERS.CoM Warranty Rev. 12/13