UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

Similar documents
PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

PM300E Voltage Regulator Instruction Manual

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

EA07. Generator Automatic Voltage Regulator Operation Manual

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

XR500B Universal Voltage Regulator

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

ESC2301. Universal Electronic Governor Controller Operation Manual

A1P OPERATING MANUAL

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

EG1069X. Generator Electronic Governor Controller Operation Manual

TROUBLESHOOTING GENERATOR UNITS

EG3000. Generator Electronic Governor Controller Operation Manual

EA16. Generator Automatic Voltage Regulator Operation Manual

SCR Power Controllers

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

AFM500X Automatic Flashing Module

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

A3Z OPERATING MANUAL

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

VoltPro VP4 Automatic Voltage Regulator

ESD5500E Series Speed Control Unit

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

A6Z OPERATING MANUAL

Filtered PWM Speed Control for Permanent Magnet DC Motors

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER

Specifications. Minimum Build Up Volts 3.5vac. Voltage Regulator

MX431 Generator Automatic Voltage Regulator Operation Manual

MDC Series

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

INSTRUCTION MANUAL FOR

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

Manual Installation & Operation

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

CONTROL FEATURES AVAILABLE OPTIONS

BLAZER D.C. MOTOR CONTROL

XR500D-277V Special Voltage Regulator

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

Experiment 3. The Direct Current Motor Part II OBJECTIVE. To locate the neutral brush position. To learn the basic motor wiring connections.

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

R231 A.V.R. Installation and maintenance R 231. This manual is to be given to. the end user. Armature 6- Field. Slow-blow fuse 250V 8 A

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

EG3002. Electronic Engine Governor Controller User Manual

N1233 Series Troubleshooting Guide for N Alternator

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

TRAC-3 TENSION READOUT AND CONTROL

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Installation and Operation Guide for PD4100 Series Power Control Centers

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

TD1512AX Technical Data. REMOTE MOUNT SOLENOID DRIVER (4-20mA Input Version)

RU BMS Power Supply and Battery Management System Owners Guide

IVT-1260 & IVT Generator Auxiliary Excitation Booster Operation Manual. (Patent Pending)

ESD5550 / 5570 Series Speed Control Units

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

KBIC SCR DC Motor Speed Controls

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

Boston Gear Ratiotrol DC Motor Speed Control

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide E. Landon Drive Anaheim, CA

LNII Series Motor and Drives

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

TABLE OF CONTENTS STANDARD FEATURES

EA06. Generator Automatic Voltage Regulator Operation Manual

Boston Gear Ratiotrol DC Motor Speed Control

CLEAN POWER TM CPS Series Operator s Manual

M O D E L USER MANUAL. FLIGHT SYSTEMS 207 Hempt Rd. Mechanicsburg PA FLIGHT SYSTEMS 207 Hempt Rd. Mechanicsburg PA 17050

CABINET REEL OPERATING INSTRUCTIONS

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

3-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

M O D E L USER MANUAL FLIGHT SYSTEMS FLIGHT SYSTEMS

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

M O D E L USER MANUAL. FLIGHT SYSTEMS 207 Hempt Rd. Mechanicsburg PA FLIGHT SYSTEMS 207 Hempt Rd. Mechanicsburg PA 17050

INSTALLATION & OPERATION MANUAL

AUTO CHARGE 11HO PIM AUTOMATIC BATTERY CHARGER

Transcription:

Model 348 UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by FLIGHT SYSTEMS www.flightsystems.com Description INSTALLATION and ADJUSTMENT INSTRUCTIONS The Model 348 Universal Regulator is a fully encapsulated and repairable module suitable for OEM applications as well as an economical replacement for many hard to get or obsolete regulators found on older generator sets. It is easy to install, does not require field flash* and works with all 240V single phase and 208-240V three-phase (or 12-lead 380-480V), 50 or 60Hz systems by connecting just 4 or 5 wires. Field or brushless exciter current of up to 4A is provided by a phase controlled SCR. The output voltage is automatically reduced during under-speed operation. A soft start feature helps prevent a sudden load on the engine at startup. See specifications and wiring diagrams below. Specifications Power Input 190-280VAC Sensing 208-480VAC Field Output-Continuous 73 VDC at up to 4.0A (255W cont.) Field Output-Forcing (240V input) 90 VDC at up to 5.0A (450W, 10 Sec.) Regulation +/- 1% Field (or exciter) Resistance 10 to 100 ohms, isolated Voltage Adjustment +/- 20% of nominal voltage Remote Voltage Adjustment +/- 5% with 1K external rheostat Stability Adjustment Under Frequency Adjustment 54-60 Hz for 60Hz systems 45-50 Hz for 50 Hz systems Generator Residual Voltage * 5 VAC min. for self starting Protection Internally Fused at 5A EMI Suppression EMI filter and voltage spike suppression Weight 6.5 oz. [0.18 Kg] Operating Temperature Range -40 C to +60 C Storage temperature Range -65 C to +85 C Power Dissipation 8 watts, Max. Connection Barrier strip with screw terminals. Size 2.64 [67] W x 3.89 [99] L x 1.90 [48] H. Installation 1. If applicable, remove the old regulator and carefully mark the wires. Verify that the field circuit is isolated from all other circuits, including ground, and that the field resistance is between 10 and 100 ohms. 2. Please refer to the dimensioned drawing. Mount (fix) the unit to a flat surface in a suitable location using the two (0.188 [4.8mm]) clear holes provided. Screw size may be #8 or #10. Make sure that the location chosen provides adequate ventilation for cooling and access to the adjustments. 3. Please refer to the appropriate wiring diagram below. Observing polarity, connect the positive field terminal of the generator to F+ and the negative field terminal to F-. 1

NOTE: Connecting the field backwards may require re-flashing of the field due to reversal/ loss of residual magnetism. 4. Connect terminals A, B and C to the proper points as shown in the appropriate wiring diagram below. The regulator is powered by the voltage between terminals C and B (280 VAC max.). The regulator senses the voltage between terminals C and A (490 VAC max.). Set switches 2 and 3 as shown in the diagrams for your system voltage. Also see re-connection diagrams under TROUBLESHOOTING at flightsystems.com. 5. Set SW 1 to the 50Hz or 60Hz position as appropriate for your generator (OFF for 60Hz, ON for 50 Hz). 6. If desired, an external remote voltage adjustment rheostat may be added by connecting it in place of the jumper that is now connected between terminals EXT1 and EXT2. See illustration & adjustment inst. below. CAUTION: Do not come in contact with any metal parts of the regulator, including the heat sink, as dangerous voltages are present when the generator is running. Adjustment Verify the wiring before proceeding with adjustment. Make sure that the 50/60Hz switch is in the correct position for your system frequency (OFF for 60Hz). Turn the STAB and U/F pots full CCW. Start the generator and bring it up to rated operating speed (use the Hz function on your DVM). Adjust the VOLTS pot until the desired output voltage is obtained. The object of the STABILITY adjustment is to obtain the best dynamic response to changes to load without instability. Under no-load conditions, turn the STAB pot slowly CW until the output voltage starts to fluctuate, then CCW until it becomes stable. Repeat if necessary. To adjust the U/F RAMP, reduce the speed of the generator to 58 Hz (48 Hz for 50Hz systems). Turn the U/F pot CW until the AC voltage just starts to fall. Optional Remote Voltage Adjustment The output voltage of the generator can be remotely adjusted by adding a 1K rheostat in place of the jumper connected between terminals EXT1 and EXT2. Before connecting the remote rheostat, follow all of the steps above for installation and adjustment. The rheostat should be wired so that its resistance decreases with clockwise rotation. See illustration. Perform output voltage adjustment as follows: 1. Set the remote rheostat at its mid point. 2. Start the generator and set the VOLTS pot on the regulator for the desired output voltage (208, 230, 240, etc.). The remote rheostat will now have an adjustment range of approximately +/- 5%. Field Flash In order for the regulator to start up automatically and build voltage, the residual voltage of the generator should be 5 VAC or higher. If a generator has not been used for a long period of time, has been apart or has had its field inadvertently reversed, it may have lost some or all of its residual magnetism. In this case, it may require field flashing. To flash the field, the generator must be stopped and the field leads disconnected. Momentarily connect the field leads to a 12 volt battery for 3-5 seconds, observing polarity (positive to F+, negative to F-). Repeat a few times. CAUTION: Do not come in contact with the field circuit because a high-voltage kickback will occur each time the circuit is interrupted. 2

TROUBLESHOOTING CHART Warranty The Model 348 Universal Regulator is warranted against defects in materials and workmanship for a period of two years from the date of shipment. This warranty does not cover damage caused by operation outside of ratings, misapplication or abuse. Flight Systems is not responsible for consequential damage to other equipment, loss of use, spoilage of product, labor or travel costs, or injury to personnel as a result of its use. Warranty service is limited to repair or replacement of product that we determine is defective, otherwise our standard repair rates will apply. This product is proudly Manufactured in the USA by FLIGHT SYSTEMS 207 Hempt Rd. Mechanicsburg PA, 17050 717-590-7330 Fax: 717-590-7327 www.flightsystems.com Issued 6/6/13 - Printed in USA 3

4

Issued 9/712 - Printed in USA 5