00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need consistent high levels of performance, reliability and stability the 00 and 00 Series sputtered thin film units offer unbeatable price performance ratio in a small package size. They feature all-stainless steel wetted parts, a broad selection of electrical and pressure connections, and wide choice of electrical outputs to allow stock configurations suitable for most applications without modification. At the heart of both these series is a sputter element that also provides exceptional temperature specifications. Plus, our manufacturing process for the 00 and 00 Series include the latest automated equipment, producing the most consistent and best price to performance sensor on the market today. Additionally, 00 Series transmitters feature thicker diaphragms and a pressure restrictor to withstand the rigors of cavitations or extreme pressure spikes, delivering years of reliable and stable performance in pulsating applications. The compact construction of both these series makes them ideal for installation where space is at a premium. And they are fully RoHS compliant. Specifications Performance Long Term Drift 0.% FS/YR (non-cumulative) Accuracy 00 0.5% FS 00 0.5% FS for <000 psi (60 bar) Thermal Error 00 0.8% FS/00 F (.5% FS/00 C) 00 % FS/00 C for <000 psi (60 bar) Compensated Temperatures -40 F to +5 F (-40 C to +5 C) Operating Temperatures -40 F to +5 F (-40 C to +5 C) Zero Tolerance 00 0.5% of span 00 % FS for <000 psi (60 bar) Span Tolerance 00 0.5% of span 00 % FS for <000 psi (60 bar) Response Time ms Fatigue Life Designed for more than 00 M cycles Mechanical Configuration Pressure Port See under How to Order, last page Wetted Parts -4 PH Stainless Steel Electrical ion See under How to Order, last page Enclosure IP6 (IP65 for electrical code A) Vibration 40G peak to peak sinusoidal, (Random Vibration: 0 to 000 Hz @ approx. 40G peak per MIL-STD-80E) Shock Withstands free fall to IEC 68-- procedure EMC (Radiated Immunity) 00 V/m Approvals CE, conforms to European Pressure Directive, Fully RoHS compliant, UL recognized files # E984 & E48 Weight 5 grams Deutsch DT04-4P M x P Amp Superseal.5 Cable Individual Specifications Output (-wire) DIN 9.4 mm Packard MetriPack 00/00 Conduit 0 V min. to 0 V max. See under How to Order, last page Volts above full scale to 0 Vdc max @ 4.5 ma (6.5 ma on dual output version) Source and Sinks ma Output (-wire) 4-0 ma 8-0 Vdc Maximum Loop Resistance ( -8) x 50 ohms Ratiometric Output 0.5 to 4.5 Vdc @ 4 ma (6.5 ma on dual output version) 5 Vdc ±0% H-
sputtered thin film Pressure Capability Pressure Range PSI (Bar) 50-00 (.5-5).00 x FS 500-,500 (40-00) Pressure Ports Proof Pressure (x Full Scale) Burst Pressure (x Full Scale) 00 00 00 00 40 x FS,000-6,000 (60-400).00 x FS 0 x FS,500-9,000 (600).00 x FS 0,000 (00) 4 x FS >60,000 PSI 5,000 (,000).50 x FS (4,000 bar) 5,000 (,800).8 x FS.40 x FS 0,000 (,00).5 x FS 0 x FS 0 x FS 9.65 0.8 4.44 0.5 4 0.55.8 0.5. 0.44 Fitting Code 08 = /8 - NPT 0 = /4-8 NPT 04 = /6-0 UNF with Flare J = /6-0 UNF with O-Ring Torque - TFFT* - TFFT* 5-6 NM 8-0 NM 6 0.6 0.6 4.5 0.5 0.4 Fitting Code OE = /4-8 NPT Internal 0K = M4 x.5 G = SAE 4 Female /6 Schrader P = 9/6-8 "Heavy Duty" Torque - TFFT* 4C - 4D TFFT* 8-0 NM 4N 8-0 0 NM 4.44 0.5 Fitting Code 4C = /4-8 /4"-8 NPTF Dryseal 4D = /8 - /8"- NPTF NPTF Dryseal 4N = SAE SAE J96/:/8-4 J96/:/8-4 /4"-9 BSPT / PT 0 = G/4 External Torque - TFFT* 05 - TFFT* OL 8-0 T NM 0-5 NM 9.65 0.8. 0.44 9.5 0. Fitting Code 05 = G/4 G/4"A A Integral Integral Face Face Seal Seal ISO OL 649-:M = M x.5 x.5 T = Mx.5 ISO 649-:M HP Metal x Washer.5 Seal Torque 0-5 NM 8-0 NM 0-5 NM tes: The diameter of all cans is 9 mm (0.48 ) Hex is mm (0.866 ) Across Flats (A/F) for deep socket mounting *NPT Threads - turns from finger tight, then wrench tighten - turns. H-
Electrical or DIN 9.4 mm M x P Amp Superseal.5 Deutsch DT04-4P Packard MetriPack KEY A C 4 POLARIZING WIDE CONTACT 4 5.9.0.9 0.0 0.8 0.8 4 B 6 0. 9. 0.6 9. 0.8 8. 0. M x P.46 8..5.45 Pin # Code B Code E Code 6 Code 8 Code 9 V supply 4 Ground Return V supply Ground Return V supply Ground Return C Pin ID Ground Return V supply A Ground Return B V supply Wiring Diagram Output (Load Resistor Range) POWER SUPPLY (-) (+) IN (+) COMMON (-) (+) OUT(+) READOUT POWER SUPPLY (-) (+) + (-) (+) (-) READOUT VOLTAGE OUTPUT TRANSDUCER CURRENT OUTPUT TRANSDUCER CUSTOMER LOAD RESISTOR (OHMS) 00 00 000 900 800 00 600 500 400 00 00 00 0 8 MAXIMUM RESISTOR (RL) 9 0 4 5 6 8 9 0 4 5 6 8 9 0 CUSTOMER SUPPLY VOLTAGE (V) Minimum Resistor Value = 50 * (+V 4) for +V > 4V Maximum Resistor Value = 50 * (+V 8) for +V > 8V MINIMUM RESISTOR (RL) H-4
sputtered thin film Cable-Out Types Strain Relief Gland / Conduit ion BLACK RED WHITE GREEN BLACK RED WHITE GREEN 4 AWG CABLE (PVC) STRAIN RELIEF 4 AWG CABLE (PVC) STRAIN RELIEF / NPT 60..4 60..4 HEX Wire Color Red Black Ground Return Ground Return White Green Mating ors Part Number Description 550 MINI DIN or, Strain Relief B 550-0M0 M Cord Set Meter (Red, Green, Blue, Yellow 4) E 550-0M0 M Cord Set Meters (Red, Green, Blue, Yellow 4) E 550-04M0 M Cord Set 4 Meters (Red, Green, Blue, Yellow 4) E 550-05M0 M Cord Set 5 Meters (Red, Green, Blue, Yellow 4) E Recommended Mating Parts (AMP p/n: Housing 808-; Contacts X 805-; Seal 894-; Boot 8808-) 6 550 AMP Superseal Mate Kit 6 09 AMP.5 Cable Cord Set Clear Pos, Black Pos, Red Pos 6 00 AMP Flying Leads Cord Set White Pos, Black, Red Pos 6 Recommended Mating Parts (AMP p/n: Socket Conn -965-. Consult AMP for Contacts, Wire Seal and Strain Relief options) 550 DIN 585 Twist Lock Mate Kit Recommended Mating Parts (Deutsch p/n: Housing Plug DT064S-P0; Wedge W4S-P0; Sockets 4X 046-0-6) 8 45 Deutsch Cord Set Long (8 AWG PVC Cable Black, Red, Green, White 4) 8 Recommended Mating Parts (Delphi Packard MetriPack p/n: Body 06586; Seal 0589. Consult Delphi for Contacts) 9 860 Packard Mate Kit 9 94 Packard Cord Set Long (4 AWG PVC Cable White, Black, Red ) 9 95 Packard Cord Set 6 Long (4 AWG PVC Cable White, Black, Red ) 9 049 Packard Mate - Flying Leads Conductor PVC 8 AWG 9 96 Packard Mate - 8 Flying Leads Conductor PVC 8 AWG 9 09 Packard Mate - 4 Flying Leads Conductor PVC 8 AWG 9 For Use on Elect. Code # H-5
How to Order Use the bold characters from the chart below to construct a product code 00 B 00PG 0 B R 00 Series 00 / 00 - Pressure Transducer Combination Pressure and Temperature 0 / 0 - Temp. Output Range -40 C to 5 C 0 / 0 - Temp. Output Range 0 C to 00 C 0 / 0 - Temp. Output Range 0 C to 80 C Output B - 4-0 ma C - -6 V H - -5 V N - 0.5-4.5 V R - 0-5 V S - 0-0 V T - 0.5-4.5 V Ratiometric Pressure Range psi 050PG - 0-50 psig 5 0CPG - 0-,000 psig 0KPS = 0-0,000 psis 05PG - 0-5 psig 5CPG - 0-,500 psig 5KPS - 0-5,000 psis 00PG - 0-00 psig 0CPS - 0-,000 psis 0KPS - 0-0,000 psis 50PG - 0-50 psig 5CPS - 0-,500 psis 5KPS - 0-5,000 psis 00PG - 0-00 psig 0CPS - 0-,000 psis 00PG - 0-00 psig 5CPS - 0-,500 psis 500PG - 0-500 psig 40CPS - 0-4,000 psis 600PG - 0-600 psig 50PG - 0-50 psig 50CPS - 0-5,000 psis 60CPS - 0-6,000 psis 5CPS - 0-,500 psis Pressure Range - bar 0004G - 0-4 barg 5 060S - 0-60 bars 000S -,000 bars 0005G - 0-5 barg 050S - 0-50 bars 600S -,600 bars 000G - 0-0 barg 0400S - 0-400 bars 006G - 0-6 barg 0600S - 0-600 bars 005G - 0-5 barg 0040G - 0-40 barg 0060G - 0-60 barg 000G - 0-00 barg tes:. Temperature outputs are for voltage output pressure sensors only (applies to codes -C, -H, -N, and -T only) and limited to connections that have 4 pins (Electrical codes -B, -E, -, and -8). Accuracy is.5% of temperature span. Requires additional ma of power.. Ranges 5,000 psi (,000 bar) and above available with -T pressure port only.. For use with pull-up or pull-down resistors, contact factory. 4. Pressure ports OE and G are NOT available with the Restrictor option. 5. 0-50 PSI (4 bar) NOT available with 4-0 ma or 0-0 Vdc outputs. -Day Delivery on Most Transducers Cable Length 00 - meter 00 - meters 00 - meters 004-4 meters 005-5 meters Optional Restrictor (00 only) R - Restrictor O - Restrictor Electrical ion B - Industrial DIN (mating connector not supplied) E - M x P (4-Pin) F - Cable version - -/ NPT Male Conduit 8 - Deutsch DT04-4P 9 - Packard MetriPack Pressure Port 4 08 - /8- NPT External 0 - /4-8 NPT External 04 - /6-0 External (SAE #4, J54) J - /6-0 External (SAE #4, J96-) 0E - /4-8 NPT Internal 0K - M4 x.5 Straight G - Schrader SAE #4, /6 Internal P - SAE 6 (9/6-8 UNF A) 4C - /4-8 NPTF External (Dryseal) 4D - /8- NPTF External (Dryseal) 4N - SAE /8-4 UNF External European Threads 0 - G/4 External 05 - G/4 External Soft Seal OL - M x.5 (<,000 bar, 5,000 psi) T - M x.5 (6g) (,000 bar, 5,000 psi) H-6