HANDLING MECHANICAL INSTALLATION

Similar documents
INSTALLATION DESCRIPTION

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

DynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

INSTALLATION 8310/8320

Pre-Installation Instructions

M670/M680BD MAGNALOCK SERIES Installation Instructions

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Package Contents. Mounting Hardware

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

Pre-Installation Instructions

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

TS93 EMF T/PT/TDE. Surface applied door closer

Legacy Installation Manual

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

2965 Magnetic Shear Lock Installation Instructions

MODEL 1200S MAGNETIC LOCK

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

MODEL 1200S MAGNETIC LOCK

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

C15C C15C. Page 1 of 20

Motorized Electric Latch Retraction

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.

Electrical Options Booklet. Table of Contents

Security Door Controls

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

I-BFV.KIT Butterfly Valve Gear Operator Replacement

APOLLO Gate Operators, Inc.

M400 Series Double Locks. Features

BX88175 Installation Instructions ToadStop II Vacuum Brake System

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

TRAC-Station BT Installation Instructions

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

2904 Power Supply Installation Instructions I-EA00041

Wolverine Turn Signal / Horn Kit 2102

LLP-UL-M-KIT Series Motorized Electric Latch Retraction

Installation Manual. Model T675A Engine Brakes. For Mack 6 Cylinder, 2 valve Head ENDT-673, 675, 676 & E6 Series Engines.

2015 Mustang Lightbar (All Models) CDC#

PD15-UL-M KIT INSTRUCTIONS

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

Installation Instructions

Chrysler 727, 904, 518 Floor Mount Automatic Transmission Shifter Installation Instructions

Assembly Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

FULL HEIGHT ALUMINUM TURNSTILE DOUBLE UNIT AT-FAL SERIES I N STALLATION AND O P E RATING I N STRUCTIONS

Inteli-Lift GEN II DUMBWAITER

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

General Applicability: KIA Sorento. Issues Current Kit does not allow for CAN DATA remote access

INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Installation and Service Manual

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Alliance Towel Dispensing System. Operation Manual

Power Supplies DORMA PS

Validator and Control Board Update Instructions for BC1

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

AL625 & AL625HD INSTALLATION & OWNER S MANUAL

Ford C4 and C6 Floor Mount Automatic Transmission Shifter Installation Instructions

DOOR SAFETY KIT INSTALLATION MANUAL

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Installation Manual. Model T680A/B Engine Brakes. For Mack 6 Cylinder, 4 Valve Head E6 and E7 Series Engines. Engine Brakes

INSTALLATION GUIDE Table of Contents

EMLock 1500 Series. MEA Listed

SHEAR ALIGNING MAGNALOCK MODEL SAM2-24 INSTALLATION AND OPERATING INSTRUCTIONS

Powerglide Automatic Floor Mount Shifter Installation Instructions

Installation & Programming Manual. Quick Reference

APOLLO Gate Operators, Inc.

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

Electro-Mechanical Swing Operator. Table of Contents

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

GATES-ELECTRIC AND MECHANICAL SELF CLOSING 2000 SERIES

E-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet

VLP-UL-KIT INSTALLATION INSTRUCTIONS. The VLP-UL-KIT for 36 or 48 is a field installable solenoid latch pullback for the Von Duprin 33/35 &

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

Legacy Installation Manual

Return to Instruction Sheet index. Installation Instructions For C-4 70 and Later, Except 70 Falcon

INSTALLATION INSTRUCTIONS MODEL 1550K-VD ELR FIELD INSTALLABLE KIT

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

ONE TOUCH CONTROL BOX

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

* * APPLICABLE MODELS: 2014 > Mazda 3

KAWNEER 1686 CONCEALED EXIT DEVICE

Transcription:

2 INSTALLATION DESCRIPTION The and 2 Delay Egress Systems are 1500 pound holding force (holding force not evaluated by UL) per leaf electromagnetic locks, electronically controlled to provide a 15 or 30 second delay in unlocking. The is one piece, for use on openings without a center mullion. The 2 is two pieces, with a ribbon cable connecting the two, for use on openings with a center mullion. All models have a master/slave configuration, meaning both leafs lock, unlock, and alarm in tandem. Both models require mechanical and electrical installation procedures as described herein. When completed, a simple adjustment procedure to set door movement will finalize the installation. 2 HANDLING The electromagnetic lock and armatures are ruggedly constructed and designed to provide years of trouble-free service. Care must be taken during installation and use, so that the lock faces and armature faces are kept free of dirt, rust, paint, or any other obstruction which may interfere with the lock and armatures making good contact. MECHANICAL INSTALLATION Familiarize yourself with the door and frame conditions. Both models must mount rigidly to the underside of the door frame header. The should be centered on the frame. For the 2, both locks should mount against the center mullion. The door mounted armatures are supplied with hardware that allows them to pivot slightly and pull away from the door as part of the delayed egress function. NOTES: This lock does not change hands to match the hand of the door. Do not remove the coil assembly from the lock housing. For locks ordered with the DSM2 option, please verify that two magnets are installed inside each of the armature housings. ELECTRICAL INSTALLATION After mechanical installation is complete, the lock needs to be wired and adjusted. A continuous power source, 12 or 24 VDC or VAC is required. Once low voltage power is supplied the unit is fully operational. Delay egress systems also normally require fire panel tie-in. All other wiring is for selected options. NOTE: Please see Egress Sensor Adjustment (page 8) before applying power. /C2 MANUAL Page 1

2 TABLE OF CONTENTS General Information... 1 Bill Of Materials... 2 Using The Template... 3 Mounting The Armature Assembly... 4 Mounting The Lock... 5 Basic Set-Up... 6 Basic Wiring... 7 Egress Sensor Adjustment... 8 Indicator Descriptions... 9 Optional Set-Up... 10 Option Wiring... 11-12 Factory Wiring... 13-14 Exploded Parts View... 15 Exploded Parts Legend / Support... 16 BILL OF MATERIALS 2 REQUIRED TOOLS (1) Electric Drill (1) #2 Phillips Screwdriver (1) Soft Faced Mallet (1) Hammer (1) Center Punch (1) Pencil & Tape Drill Bits: 1/8, 5/16, 3/8, 9/16 (1) LOCK ASSEMBLY (2) ARMATURE (2) ARMATURE HOUSING (2) ARMATURE MOUNTING PLATE ASSEMBLY (2) HARDWARE KIT (2) DOOR SIGN - 15 SECONDS * (1) TEMPLATE (1) INSTALLATION MANUAL * 30 SECONDS SIGNS AVAILABLE HARDWARE KIT CONTENTS - (2) Part #301325 QTY. ITEM DESCRIPTION (5) Fas-Trak Mounting Screws #10 x 1 phillips pan head tek screw (5) Fas-Trak Mounting Screws 10-24 x 1/2 phillips pan head machine screw (1) Armature Mounting Screw 5/16-18 x 1 hex flat head machine screw, turned (1) Armature Spacer 3/8 D x 0.360 L (1) Armature Spring Compression spring (4) Armature Mounting Plate Screws #10 x 1 phillips flat head sheet metal screw (4) Armature Housing Mounting Screws 8-32 x 3/8 phillips machine screw (1) Anti-Tamper Cover Screwdriver #6 spanner key (1) Fas-Trak Set Screw Wrench 1/8 ball head hex wrench (1) Armature Bolt Wrench 3/16 hex wrench (1) Thread Locking Compound Liquid (2) Bypass/Reset Key (1) Mini Screwdriver NOTE: For further parts clarification refer to the Exploded Parts View on page 15 or consult factory. /C2 MANUAL Page 2

2 MOUNTING CONSIDERATIONS Inspect the door frame and determine if an angle bracket, spacer or filler plate will be required for installation. The lock will require a 2-9/16 wide header stop for a suitable mounting surface. 2-9/16 2-9/16 NORMAL MOUNTING *FILLER PLATE REQUIRED *SPACER PLATE REQUIRED *ANGLE BRACKET REQUIRED *These items are available from DynaLock. USING THE TEMPLATE 1. Fold the template(s) on the dotted line to form a 90 degree angle. Scoring the template(s) with a straight edge and a screwdriver will make it fold easier. 2. : With the doors in the closed and latched positions, place the template against the header and doors, centered on the frame. Tape in place. 2: With the doors in the closed and latched positions, place the templates against the header and doors, with the edges against the center mullion. Be sure to use the correctly handed template for each door. Tape in place. CARDBOARD TEMPLATE 3. Transfer all hole locations to both the doors and header with a center punch, then remove the template(s) from the doors. 2 4. 5. Referring to the template(s), drill four 1/8 dia. lock mounting holes and one or two 9/16 dia. wiring hole(s) in the top of the frame, at the transferred locations. Drill the remaining transferred holes in the face of each door to accept the Armature Mounting Plate Assemblies: a. Four 1/8 dia. mounting screw holes, 1 deep. b. One 3/8 dia. armature screw clearance hole, 3/8 deep. c. One 5/16 dia. adjustment wheel screw clearance hole, 1/4 deep. CARDBOARD TEMPLATES HINGE SIDE OF DOOR /C2 MANUAL Page 3

2 MOUNTING THE ARMATURE ASSEMBLIES Using the four #10 x 1 flat head sheet metal screws attach the armature mounting plate to the door. Firmly tighten the screws with a #2 phillips screw driver. (1) 3/8 DIA. ARMATURE SCREW CLEARANCE HOLE, 3/8 DEEP (4) 1/8 DIA. MOUNTING SCREW HOLE - 1 DEEP (4) #10 X 1 MOUNTING SCREW (1) 5/16 DIA. ADJUSTMENT WHEEL SCREW CLEARANCE HOLE - 1/4 DEEP Attach the Armature to the Mounting Plate Assembly using the hardware supplied. Apply the supplied thread locking compound to the threads of the Armature Mounting Screw and firmly tighten with a 3/16 hex wrench. The head of the armature mounting screw must not project beyond the face of the armature. Failure to properly secure the Armature to the door could result in serious injury or possible security breach. Check the installation by pushing in on a corner of the Armature - it should move. Although the mounting screw is tight the Armature should have approximately 1/4 of free play, under slight spring tension. ARMATURE MOUNTING PLATE ASSEMBLY ARMATURE HOUSING 8-32x3/8 ARMATURE HOUSING SCREW ARMATURE SPRING 0.360 L ARMATURE SPACER 5/16-18x1 TURNED ARMATURE MOUNTING SCREW REPEAT FOR OTHER DOOR /C2 MANUAL Page 4

2 1. 2. MOUNTING THE LOCK Before installation begins remove the rear Electronics Covers, End Covers and Sensor Cover Assemblies (see page 13-15 for parts locations). Carefully unplug the sensor harnesses from the circuit board connectors and detach the Sensor Cover Assemblies from the lock. For 2, carefully remove the ribbon cable. In the upper inside corners of the lock housing(s) are located #1/4-28 set screws. Using the 1/8 ball head hex wrench loosen (do not remove) the set screws until the Fas-Trak Baseplate(s) is free (Fig. C ). Remove the Fas-Trak(s). Place the Fas-Trak(s) against the header with the slot counter bores visible and the tabs facing the doors (Fig. A ). Attach the Fas-Trak(s) to the header at the slotted hole locations, with #10 x 1 tek screws or 10-24x1/2 machine screws. Tighten the screws just snug enough to allow for final adjustment. VISIBLE SLOT COUNTER BORES FIG. A TABS FACING DOOR 3121B 3121B2 3. Temporarily mount the lock(s) to the Fas-Trak(s) by offsetting the lock(s) 1-1/8 from the jamb (Fig. C ) and tipping the front of the lock(s) down engaging the rear flange of the Fas-Trak(s) (Fig. B ). Rotate the lock(s) up allowing two tabs (one for 2) to pass through the corresponding notch in the top of the lock housing. Slide the lock(s) into position. Close and latch the doors. Check that the armature and lock faces make full contact. If any adjustment is required gently tap the housing(s) with a soft mallet until full contact is achieved. Open the doors, remove the lock(s) from the Fas-Trak(s) and tighten the slot screws. Drive additional screws into the header using the Fas-Trak(s) as a physical template. Screw heads must not project above the Fas-Trak(s). FIG. B FAS-TRAK ENGAGE REAR FLANGE LOCK 4. Any roughed-in wiring may be brought in at this time through the slotted wiring hole(s) (for 3121B2 include ribbon cable). Re-install the lock on the Fas-Trak(s). Firmly tighten the housing set screws with the 1/8 ball head hex wrench. Re-install the End Covers and Sensor Cover Assemblies. Carefully plug the Sensor harnesses back into the connectors on the circuit boards (see page 13&14). If the lock wiring and set-up are not being done at this time, replace the Electronics Covers and see that these instructions (and ribbon cable for 2) are left for the electrical installer. 1-1/8 OFFSET FAS-TRAK TABS FIG. C SET SCREWS 1-1/8 OFFSET FAS-TRAK TABS 2 MASTER LOCK SET SCREWS CENTER MULLION SLAVE LOCK /C2 MANUAL Page 5

2 BASIC SET-UP 1. Remove the Electronics Cover from the Master Lock (right side) to expose the master circuit board assembly. 2. L - Cover LED Bi-color LED, mounted to circuit board housing cover. Displays Red or Green, depending on lock mode (see page 9 for indicator modes). LED is tethered to the J9 circuit board connector, via a 30-wire harness. Should harness become unplugged, observe wire color polarity when reconnecting (see page 13 for further info). 3. C - System Selector Switches The selector switches (S3) which control major system functions are factory set to the OFF position for basic lock operation. Switch 1 will be used during sensor adjustment (page 8). Switches 2 through 7 are only used for options described on page 10. (Factory Setting) /C2 MANUAL Page 6

2 BASIC WIRING Basic hook-up is shown below. For other system features hook-up see Option Wiring (page 11). POWER FAC 1 2 3 4 Terminals 1& 2 - Auto-Sensing Power Input. May be 12 or 24 Volts, AC or DC, uninterrupted. Maximum current draw, by voltage, is as follows: 12V DC: 839mA 12V AC: 1.79A 24V DC: 470mA 24V AC: 1.27A CONTINUOUS POWER INPUT 12/24 VAC/VDC FIRE PANEL INPUT N.O. OR N.C. CONTACTS DO NOT INTERRUPT INPUT POWER (TERMINALS 1 & 2) FOR AUTHORIZED ACCESS/EGRESS. EXTERNAL ACCESS/EGRESS CONTROLS (EX. KEYPAD, CARD READER, ETC.) SHOULD USE DEDICATED BYPASS TERMINALS 7 & 8 or 9 & 10 (SEE PAGE 11). Terminals 3 & 4 - Fire Panel Input. May be normally-open (N.O.) or normally-closed (N.C.) dry contacts from fire panel (check fire alarm control jumper FA - page 6). DO NOT APPLY POWER TO TERMINALS 3 & 4 OR CIRCUIT BOARD DAMAGE WILL OCCUR. When the fire panel trips, the 3101B will release, the audible will sound a constant tone and the bi-color LED (LED1) will change to green. When the fire panel is reset, the 3101B will reset and lock. NOTES: 1. A power limited, UL Listed power supply for security applications is required for UL294 installations. 2. 3. When the /2 is used with a fire alarm control panel, wiring must be done for fail-safe operation. Suitability of all wiring leads is to be determined based on enduser product requirements. PROPER OPERATION OF THE /C2 REQUIRES ADJUSTMENT OF THE EGRESS SENSORS PROCEED TO EGRESS SENSOR ADJUSTMENT /C2 MANUAL Page 7

2 EGRESS SENSOR ADJUSTMENT The sensor and armature assemblies are designed for use on doors with existing mechanical latching hardware. If used on doors without latches, false alarms are possible. In these cases, we suggest using external triggers such as our 6451 Exit Sensor Bars - connect using terminals 11&12 and disable the internal sensors (see pages 10&11). SEE PAGE 10 FOR LOCATION OF ELECTRONIC PARTS MENTIONED IN THIS SECTION 1. With both doors closed and latched apply input power to terminals 1 & 2 on Master Lock. Slide selector switch (DS1) #1 to the ON position to activate the Set-Up mode. Rotate the on-board keyswitch counter-clockwise. The lock should now be unlocked (LED1-OFF). EGRESS SENSOR ADJUSTMENT WHEEL 2. Open both doors. Temporarily remove the Adjustment Wheel Stops from the Armature Mounting Plates and close the doors. Set aside for re-installation later. 3. With the doors closed observe the bi-color LED (LED1) on the circuit board. It should be lit red. If it is not lit, rotate the adjustment wheels counter-clockwise as necessary to ensure that they will contact and fully depress the ball plungers on the lock. Rattle the doors to ensure the LED remains lit. 4. With the doors closed and LED1 lit red, unlatch and slowly open either door. The LED will shut off as soon as the door opens far enough for the ball plunger to fully project. Check that the other door operates in the same manner. NOTE: LEDs operate in tandem - both LEDs will go out when either door is opened. ARMATURE MOUNTING PLATE WHEEL STOP WHEEL STOP MOUNTING SCREW DOOR CLOSED AND LATCHED DOOR UNLATCHED & MOVED 5. With adjustment completed, re-install the adjustment wheel stops to lock-in the adjustments. Close the doors, slide selector switch (DS1) #1 back to the OFF position and return the on-board keyswitch to the center position to relock the 3121B/B2. WHEEL STOP INSTALLED (LOCKS ADJUSTMENT) 6. Unlatch and push on either door until delay egress triggers (1-3 seconds). The audible will sound and LED1 will flash red. After 15 seconds, both sides of the lock will release. Turn the on-board keyswitch clockwise to reset the lock. If delayed egress triggers too soon, or fails to trigger, re-adjust the sensor adjustment wheel(s) for desired sensitivity. Check that the other door operates in the same manner. /C2 MANUAL Page 8

2 BUILT-IN KEYSWITCH OPERATION POSITION CENTER CLOCKWISE (SPRING LOADED) COUNTER-CLOCKWISE DESCRIPTION NORMAL / LOCKED RESET AFTER DELAY EGRESS ALARM BYPASS / UNLOCKED WITHOUT ALARM INDICATOR & AUDIBLE DESCRIPTIONS CONDITION AUDIBLE SIGNAL LOCK COVER LEDS DELAY EGRESS ALARM One second pulse rate during delay cycle. ON BLINK RED DELAY EGRESS ALARM Steady tone after delay until reset. OFF GREEN FIRE ALARM RELEASE Steady tone until fire alarm contacts are reset. OFF GREEN OPTIONAL REMOTE AUTHORIZED BYPASS (TERMINALS 7&8 / 9&10) None, unless bypass audible is enabled (dip switch 2). If door is held open past relock time, goes into delay egress alarm & requires reset. OFF BLINK GREEN POOR MAGNETIC BOND Rapid pulse rate until problem is corrected (only functional with Dynastat Force Sensor option). N/A FAST BLINK RED /C2 MANUAL Page 9

2 OPTIONAL SET-UP C 1. C- System Selector Switches Set the System Selector Switches (S3) to address your specific system requirements. The normal factory setting is all switches off. SWITCH FUNCTION OFF MODE SETTINGS ON 1 SYSTEM SET-UP NORMAL SET-UP MODE 2 BYPASS AUDIBLE * DISABLED ENABLED 3 NUISANCE DELAY 1 SEC. 3 SEC. 4 EGRESS DELAY 15 SEC. 30 SEC. 5 MASTER AUDIBLE ENABLED DISABLED 6 FIRE ALARM INPUT SETTING 7 EGRESS SENSOR ENABLED DISABLED 8 UNUSED SPARE NORMALLY OPEN NORMALLY CLOSED *Only applies to terminals 9&10 (see next page) /C2 MANUAL Page 10

2 OPTION WIRING /2 3121B/B2 MASTER MOTHERBOARD CIRCUIT BOARD S2 STANDARD INPUT/OUTPUT TERMINALS (TYPICAL - ALL MODELS) OPTIONAL OUTPUT TERMINALS (AS ORDERED) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 SEE PAGE 7 FOR WIRING INFORMATION REMOTE RESET INPUT A REMOTE BYPASS INPUT B REMOTE BYPASS INPUT TIME DELAY C REMOTE TRIP INPUT D NC C NO DELAY EGRESS OUTPUT E NC C NO NC C NO NC C NO DYN2 OPTION OUTPUT DSM2 OPTION OUTPUT ATS2 OPTION OUTPUT F G H A! WARNING: Do not apply power to inputs marked! or damage will occur. Per UL294 installlations, all wiring must interconnect to equipment in the same room. REMOTE RESET INPUT Momentarily closing a normally-open dry contact across terminals 5 & 6 will reset and re-lock the /C2 following delayed egress and re-closure of door. INPUT DESCRIPTIONS C REMOTE BYPASS INPUT TIME DELAY Momentarily closing a normally-open dry contact across terminals 9 & 10 will immediately release the lock without alarm. The door will remain unlocked for a period of time controlled by on-board adjustable timer S2. To increase the delay rotate timer S2 clockwise. Range is 1 to 75 seconds (~5 sec. per click). For NFPA101 applications, the remote bypass device time delay must be set for 0 seconds. B REMOTE BYPASS INPUT Momentarily closing a normally-open dry contact across terminals 7 & 8 will immediately release the lock without alarm. The door will remain unlocked until the contact is opened. Connect authorized access/egress control(s) here (typical). D REMOTE TRIP INPUT Momentarily closing a normally-open dry contact across terminals 11 & 12 will initiate delayed egress. This input may be used as a redundant or substitute means of triggering delayed egress if built-in sensor initiation is not desired (see page 10, note 3). /C2 MANUAL Page 11

2 OPTION WIRING E MONITORING OUTPUT DESCRIPTIONS DELAY EGRESS OUTPUT Delay egress alarm monitoring. NC C NO 13 14 15 TYPICAL WIRING SPDT dry relay contacts rated 1A @ 24VDC/24VAC ALARM TO INDICATOR POWER SUPPLY Contacts change state upon initiation of delayed egress, after the nuisance delay has elapsed. They remain in that state until both doors are closed and reset. SECURE NOTE: INDICATORS ARE NOT INCLUDED F DYN2 OPTION OUTPUT Dynastat bond sensor monitoring. NC C NO 16 17 18 SPDT dry relay contacts rated 1A @ 24VDC/24VAC Contacts change state to signal lock status as either both secure or either door unsecure. Armature misalignment can also create an unsecure condition. UNSECURE SECURE TO INDICATOR POWER SUPPLY NOTE: INDICATORS ARE NOT INCLUDED G DSM2 OPTION OUTPUT Door position sensor monitoring. SLAVE DSM NC C NO MASTER NC C NO 19 20 21 TO INDICATOR POWER SUPPLY (2) SPDT dry relay contacts rated 0.5A @ 24VDC Contacts change state to signal physical door position as either closed or open. Slave side has its own connection. Both are independent circuits that do not require lock power to operate. OPEN CLOSED NOTE: INDICATORS ARE NOT INCLUDED H ATS2 OPTION OUTPUT Anti-Tamper Switch monitoring. SLAVE ATS NC C NO MASTER NC C NO 22 23 24 TO INDICATOR POWER SUPPLY (2) SPDT dry relay contacts rated 0.25A @ 24VDC Contacts change state to signal removal of lock module s electronics cover. Slave side has its own connection. Both are independent circuits that do not require lock power to operate. TAMPER NORMAL NOTE: INDICATORS ARE NOT INCLUDED /C2 MANUAL Page 12

2 COIL HARNESS (4 COND.) FACTORY WIRING - MASTER LOCK MODULE 3101C SENSOR COVER ASSEMBLY DYNASTAT HARNESS LOCK COIL ASSEMBLY 3121A SERIES LEGACY SENSOR DSM OPTION SENSOR (OPTIONAL) (2 COND.) DSM OPTION HARNESS (3 COND.) RIBBON CABLE TO SLAVE LOCK MODULE SENSOR HARNESS (4 COND.) BPM BYPASS MONITOR OPTION (2 YELLOW COND.) MAINTAINED - N.O., 4A@125V ON-BOARD KEYSWITCH KEYSWITCH HARNESS (3 COND.) COVER LED LED HARNESS (3 COND.) /C2 MOTHERBOARD NOTES: 1. 2. 3. 2 Ribbon Cable must be routed through header jamb. Harnesses J6 and J8 are only present if the lock is equipped with the DYN2 - Dynastat Force Sensor and/or DSM2 - Door Status Switch Options. Observe polarity when re-connecting the J5, J7, J8 and J9 harness connectors. Orient these connectors with respect to harness wire colors as follows: J5 WHT GRN RED BLK **J10 WHT BLK BLU J7 WHT BLK BLU J8 GRN WHT RED J9 GRN BLK RED J2 ORIENT CABLE WITH RED STRIPE TO LEFT AS SHOWN ABOVE 4. Harness connectors J3 and J6 are not polarity sensitive. **Note: J10 is normally not-used. It is specifically intended to allow interfacing the /C2 Circuit Board to a 3121A Series legacy sensor cover assembly, when necessary. /C2 MANUAL Page 13

2 DSM DOOR STATUS SWITCH OPTION HARNESS (3 COND.) FACTORY WIRING - SLAVE LOCK MODULE SLAVE ATS OPTION SENSOR ATS ANTI-TAMPER SWITCH OPTION HARNESS (3 COND.) SLAVE DSM OPTION SENSOR COIL HARNESS (4 COND.) LOCK COIL ASSEMBLY DYNASTAT FORCE SENSOR OPTION HARNESS (2 COND.) SENSOR HARNESS (4 COND.) SENSOR COVER ASSEMBLY 3121A SERIES LEGACY SENSOR (OPTIONAL) LEGACY SENSOR HARNESS RIBBON CABLE TO MASTER LOCK MODULE NOTE: ATS & DSM options are not interconnected with the master lock module. Field connections must be made on both the motherboard and the daughter board. LED NOTES: 1. 2. 3. 4. 2 Ribbon Cable must be routed through header jamb. Harnesses J2, J3 and J4 are only present if the /C2 is equipped with the DYN2 - Dynastat Force Sensor, DSM2 - Door Status Switch, and/or ATS2 - Anti-Tamper Switch Options. Observe polarity when re-connecting the J1, J2, J3, J5 and J7 harness connectors. Orient these connectors with respect to harness wire colors as follows (J1 - ORIENT CABLE WITH RED STRIPE TO LEFT AS SHOWN ABOVE): J2 J3 J5 J7 **J12 RED RED GRN WHT BLU WHT WHT BLK GRN BLK GRN GRN RED RED WHT BLK Harness connectors J4 and J6 are not polarity sensitive. 3121 DAUGHTER BOARD **Note: J12 is normally not-used. It is specifically intended to allow interfacing the /C2 Daughter Board to a 3121A Series legacy sensor cover assembly, when necessary. /C2 MANUAL Page 14

2 EXPLODED PARTS VIEW 1 2 2 8 7 5 3 9 10 4 6 15 12 16 11 LEGEND ON NEXT PAGE 13 14 18 17 19 20 21 22 /C2 MANUAL Page 15

EXPLODED PARTS VIEW LEGEND ITEM DESCRIPTION PART # 1 Fas-Trak Baseplate 300011 2 #10x1 Self-Tapping Screw * 2 10-24x1/2 Machine Screw * 3 Lock Housing 4 Access Cover & Sensor Assembly 301037 5 8-32x3/8 Machine Screw 300608 6 1/4-28x1/4 Set Screw 300604 7 Electronics Cover 300353 8 6-32x1/2 Spanner Security Screw 700058 9 End Cover 300010 10 Double Fas-Trak Baseplate 300015 ITEM DESCRIPTION PART # 11 Armature Mounting Plate Assy. 301038 12 Sensor Adjustment Wheel & Stud 301383 13 Wheel Stop 301003 14 8-32x1/2 Wheel Stop Screw 301005 15 #10x1 FHS Mtg. Plate Screw * 16 Armature Housing w/ pads 301334 17 8-32x3/8 Armature Mtg. Screw * 18 Disc Magnet (DSM only) 301289 19 Armature 300373 20 Compression Spring * 21 0.360 L Armature Spacer * 22 5/16-18x1 Armature Bolt (turned) * * Part of Hardware Kit 301325 (the lock comes with two hardware kits) Refer to Page 15 for parts locations. PLEASE DELIVER THIS MANUAL AND THE KEYS TO THE END USER UPON COMPLETION OF THE INSTALLATION AUXILIARY LOCK CATEGORY GWXT SPECIAL LOCKING ARRANGEMENTS CATEGORY FWAX FOR PRODUCT SUPPORT AND PARTS ORDERING INFORMATION CONTACT: DynaLock Corp. 705 Emmett Street Bristol, CT 06010 Bus: (877) 396-2562 Toll-Free USA (860) 582-4761 Fax: (860) 585-0338 DYNALOCK ON THE INTERNET: E-mail: info@dynalock.com Website: www.dynalock.com /C2 MANUAL Page 16