product manual H-4156M CBR-Specific Load Frame

Similar documents
product manual H-3620, H-3624, H-3625 Flow Table with Mold

product manual H-1240 & H F Electric Penetrometer with Digital Automatic Timer

product manual H-2966B H-2966B Production, Cylinder End Grinder

product manual H-3860D H-3860D_man_0816 Los Angeles Abrasion Machine

Model ESMH MOTORIZED FORCE MEASUREMENT TEST STAND. User s Guide

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

MTS Criterion Series 40 Specifications - Comparative

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Operating Instructions

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

CAUTION. Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.

HLS Watt Halogen Illuminator Service Manual

WARNINGS, CAUTIONS AND NOTES


ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

Air Curtain Motor/ Blower Assembly

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Installation and Operations Manual

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

DURHAM GEO SLOPE INDICATOR

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

P/N Wheeler. user manual

AUTO CHARGE D PUMP PLUS

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

Refinery Supply Company, Inc.

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216

Effective June 1, 2013 This guide supersedes all previous versions

MANLEY LABORATORIES, INC. MANLEY REFERENCE JUNIOR DAC OWNER'S MANUAL 20 BIT DIGITAL TO ANALOG CONVERTER

Users Manual. Phase Rotation Indicator

Introduction. Installing the TC 2. Unpacking the TC 2

Measurements are expressed in millimeters.

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

OPERATOR'S MANUAL Model CHL91302 Battery Charger for use with LITHIUM EARTHWISE Lithium-ion Battery Pack

Model 616 Rotating Disk Electrode Instruction Manual

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Go Power! Manual. GP-Smart Charger

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Motion Sensing Coach Light

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

OWNER S MANUAL MODEL: PT 450 / PT 450M WELDING POSITIONER

OPERATOR S MANUAL Please read all the information in this booklet before using the unit.

FD Conveyor for FD 260 Tabber

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

Force Test Stands Series ES MODELS ESM & ES30. User s Guide

IONIZATION SOLUTIONS

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Twin-Column Motorized Tension, Compression & Cycle Tester (M5KNE & M10KNE) User s Manual

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Switching DC Power Supply

PARTS LIST FOR LN-25 LN-25

Cruising Charger Series OWNER S MANUAL

INSTRUCTION MANUAL CAUTION

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

OPERATION MANUAL. Model TWP-2. Toll free customer support:

A48 / A48B (base plate) BATTERY CHARGER

ULTRAWARMER HOLDING STATION INSTALLATION & OPERATIONS MANUAL

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

TCS 1200 Portable Temperature Calibrator

LESTRONIC II BATTERY CHARGER MODEL 19740

Model LA 4400 Time Delay OFF Controller

ADI-125/750 ADI-125/1500 ADI-125/2500

BATTERY SAVER LOW RIPPLE HO

12 amp RMS Battery Charger

Integrated Heating System

2 PORT MOTORISED VALVE (28 mm)

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Model LA 4300 Time Delay OFF Controller

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

INSTRUCTION MANUAL FOR PC63 CAGE

GENERAL PURPOSE MIXERS

Boston Gear Ratiotrol

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Battery Charger JCB-FCH20LI2

INSTALLATION INSTRUCTIONS

# Traction Control Window Switch

Concrete ASTM COMPRESSION TESTER ACCESSORIES

Battery Charger JCB- SCH20LI.2

WF-5110R True Sine Wave Inverter

TCI Ford C-6 TransBrake Valve Body Shift Pattern: Park, Reverse, Neutral, First, Second, Third

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Model LA 4100 Time Delay OFF Controller

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

1 AMP CURRENT SOURCE

WS-Series. Operating Instructions. Pulse DC End Area Coils. Drilco Style WS-Series Coils 1. E s t a b l i s h e d WS-14 WS-12 WS-10 WS-8

Environmental Series Air Curtains

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

DP140e. Installation & Operations Manual

1 CMP throttle stud, two 3/8" nuts, a 3/8" bolt and corrector plate) CMP R4 Universal Cable 1

Owner s Manual and Warranty Information

Model 1693, 1694 Switching DC Power Supply

Transcription:

09.08 product manual H-4156M CBR-Specific Load Frame

this is a blank page corrector

Introduction Product Description H-4156M The Humboldt H-4156M CBR-Specific Load Frame Set has been designed to provide labs with a single-speed load frame specifically designed to do California Bearing Ratio (CBR) testing. The machine has a one-speed motor with a reversing switch that produces a uniform vertical movement of.05" (1.27mm) per minute, ASTM D1883, AASHTO T193. The maximum piston travel is 3 1/2" (88mm). The H-4156M is sold as a CBR-specific set and includes: (1) H-4156M CBR-Specific Load Frame (115 VAC 60 Hz, 1 phase) (1) H-4454.100 Load Ring, 10,000lbf (50kN) (1) H-4158.1 Dial Indicator, 1.000" x.001" (1) H-4178 Penetration Piston with Stud (1) H-4178BR Dial Indicator Bracket Product Description H-4156M.4F The Humboldt H-4156M.4F CBR-Specific Load Frame Set has been designed for use in 220 50/60Hz applications and those who need to test CBR to the BS 1377: Part 4 Standard of.04" (1.00mm) per minute. When operated at 60Hz, the H-4156M.4F complies with the ASTM D1883 Standard; and, when operated at 50Hz it complies with the BS 1377: Part 4 Standard. The H-4156M.4F also includes the following items: (1) H-4156M CBR-Specific Load Frame (220 50/60Hz, 1 phase) (1) H-4454.100 Load Ring, 10,000lbf (50kN) (1) H-4158.1 Dial Indicator, 1.000" x.001" (1) H-4178 Penetration Piston with Stud (1) H-4178BR Dial Indicator Bracket Physical Specifications: Shipping weight: 185 lbs. (78.9 kg) Overall height: 39" Base dimension: 16" x 18" x 10"

General Information Inspection Your CBR equipment was thoroughly inspected before it was shipped and should be ready to operate as soon as you have completed the set-up procedure. Notify Humboldt Mfg. Co. or your local agent and file a claim with any carriers involved if you find any damage to the machine. Unpack all of the equipment carefully to prevent loss of small items or manuals. Physical Specification Shipping weight: 185 lbs. (78.9 kg) Overall height: 39" Base dimension: 16" x 18" x 10" Power Supply 110 VAC 60 Hz 1 phase (H-4156M), 375 watts 220 VAC 50/60 Hz 1 phase (H-4156M.4F), 375 watts Check to make sure your machine has the correct voltage for your local supply. Power Cord The H-4156M machine is fitted with a molded vinyl-grounding plug, while the H-4156M.4F is supplied without a plug allowing you to fit it with the correct plug for your application. The cord is made of three conductors: (American color-coding) Green Ground (Earth) White Cold (Neutral) Black Hot (Live) (International color coding) Green/Yellow Ground (Earth) Blue Cold (Neutral) Brown Hot (Live) Fuses The CBR Test Machine uses a slow-blow fuse that is fitted into the left side of the machine. The replacement part number is H-1339.13. Initial Installation Remove the packing list and verify that all parts have been received. Normally you will receive one crate comprised of compression frame and a calibrated load ring (H-4454.100) 10,000lbf capacity, and accessories for CBR penetration. Set the machine base up at the place it is to be used in the laboratory and then check that it is level by placing a spirit level on the platen. If it is not level, adjust the feet of the machine.

Operation Control Panel The control panel is situated on the front left hand side of the machine base. Preset Speed: H-4156M: H-4156M.4F (60Hz): H-4156M.4F (50Hz):.05 in/min. (1.27mm/min.).05 in/min. (1.27mm/min.).04 in/min. (1.00mm/min.) Direction of Travel It is necessary to ensure that the direction of the platen (up or down) has been correctly selected. The platen travel direction switch has three positions: up, off, down. Before changing travel direction, you must first switch to the off position and pause for a second before changing travel direction. Maximum Travel Limits The maximum up travel limit occurs when the loading screw extends beyond the reach of the drive gear and remains there it is not indicated by a light. The down travel limit is indicated on the control panel with a red indicating light. The machine will stop operation in that direction when this light is illuminated. The maximum travel of the platen is 3.50" (88mm). IMPORTANT You must use the toggle switch to stop test. The machine does not stop automatically when the stability load is reached. Load Ring When a load ring is used it can be attached directly to the cross-beam using the 3/4-16 x 3 long bolt. Maximum Load The Marshall Compression and Testing Machine is rated at 10,000lbf (or 50kN). Penetration Measurement Can be measured with the H-4178 Penetration Piston and Stud and the H-4158.1 Dial Indicator, which is mounted to the penetration piston by H-4178BR Dial Indicator Bracket. These items are included with your H-4156M CBR-Specific Load Frame.

Load Ring Calibration Your H-4454.100 was calibrated before leaving the factory. Periodically you should have it re-calibrated. Humboldt provides calibration services for these load rings, please contact us at: 1.800.544.7220, 1.708.456.6300, 1.708.456.0137 fax or hmc@humboldtmfg.com. Maintenance The machine and transducers should be kept clean and the machine should not be over lubricated. Light oiling with synthetic instrument oil at most is required on exposed spindles and threads.

WFO4 3/4" flat washer SHH04 3/4-16 x 3 1/2" Hex Head Bolt H-1339.6 Nut H-4454.100 Load Ring H-4178BR Dial Indicator Bracket H-4178 Penetration Piston and Stud H-4158.1 Dial Indicator 1.000" x.001" H-1339.14 Threaded Rod H-1339.18 Platen H-1339.17 Bellows H-1339.4 Leveling Foot

Warranty Humboldt Mfg. Co. warrants its products to be free from defects in material or workmanship. The exclusive remedy for this warranty is Humboldt Mfg. Co., factory replacement of any part or parts of such product, for the warranty of this product please refer to Humboldt Mfg. Co. catalog on Terms and Conditions of Sale. The purchaser is responsible for the transportation charges. Humboldt Mfg. Co. shall not be responsible under this warranty if the goods have been improperly maintained, installed, operated or the goods have been altered or modified so as to adversely affect the operation, use performance or durability or so as to change their intended use. The Humboldt Mfg. Co. liability under the warranty contained in this clause is limited to the repair or replacement of defective goods and making good, defective workmanship. Humboldt Mfg. Co. 3801 North 25th Avenue Schiller Park, Illinois 60176 U.S.A. U.S.A. Toll Free: 1.800.544.7220 Voice: 1.708.456.6300 Fax: 1.708.456.0137 Email: hmc@humboldtmfg.com Testing Equipment for Construction Materials HUMBOLDT www.humboldtmfg.com