GENERAC GUARDIAN SERIES STANDBY GENERATORS

Similar documents
GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Siemens Liquid Cooled Standby Generators

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Siemens Liquid Cooled Standby Generators

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector Series

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector QS Series

GENERAC GUARDIAN SERIES STANDBY GENERATORS

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

GENERAC GUARDIAN SERIES STANDBY GENERATORS

1P 120/240V, 3600 RPM,

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. INCLUDES: True Power Electrical Technology

22 / 27 / 32 / 38 / 48 kw

17 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. Standby Power Rating Model (Steel - Gray) - 16 kw 60Hz

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

Protector Series ISO FEATURES. Diesel Generator Set INCLUDES:

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

8/10/14kW. 8/10/14kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES INCLUDES:

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

STANDBY GENERATORS 17 kw AIR-COOLED GENERATOR SETS

17/20kW. 17/20kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Protector Series ISO FEATURES. Diesel Generator Set. Protector Series INCLUDES:

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

STANDBY GENERATOR 20 kw AIR-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model (Steel - Dark Gray) - 20 kw 60 Hz - US

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Optimus Residential Standby Generators

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

16/20/22 kw CENTURION SERIES

Spark-ignited generator set

9/11 kw. 9/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

8/11/13kW. 8/11/13kW. CENTURION SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

8/11/14kW. 8/11/14kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

20 KW / 25 KVA LIQUID COOLED POWERED by

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Spark-ignited generator set

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

Diesel generator set QSX15 series engine

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

48kW ¹ STANDBY GENERATOR

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

Diesel generator set QSX15 series engine

16/20/22 kw. 16/20/22 kw GUARDIAN SERIES FEATURES. Residential Standby Generators Air-Cooled Gas Engine. Standby Power Rating INCLUDES: 1 of 6

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

Diesel generator set 6BT5.9 series engine

Quiet Connect TM Series - RS13A, RS17A, RS20A, & RS20AC

Diesel generator set QSK23 series engine

35kW ¹ STANDBY GENERATOR

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

Diesel generator set QSB7 series engine

8/11 kw. 8/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

Transcription:

GENERAC GUARDIAN SERIES STANDBY GENERATORS kw INCLUDES: Generac Naturally Aspirated Gaseous Fueled 1.6L Engine Liquid-Cooled Engine Generator Sets Standby Power Rating Model (Bisque) - kw 60Hz Two Line LCD Tri-lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System Smart Battery Charger UV/Ozone Resistant Hoses ±1% Voltage Regulation Natural Gas or LP Operation 2 Year Limited Warranty UL 2200 Listed Meets EPA Emission Regulations CA/MA emissions Compliant FEATURES INNOVATIVE DESIGN & PROTO TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN. But it doesn t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. TEST CRITERIA: PROTO TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. An unequalled ±1% voltage regulation. SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.

Application & Engineering Data GENERATOR SPECIFICATIONS ROTOR INSULATION STATOR INSULATION Synchronous Class F Class F TELEPHONE INTERFERENCE FACTOR (TIF) <50 ALTERNATOR OUTPUT LEADS 3 PHASE BEARINGS COUPLING LOAD CAPACITY (STANDBY RATING) EXCITATION SYSTEM VOLTAGE REGULATION SENSING 4 wire Sealed Ball Flexible Disc kw Direct Electronic Single Phase REGULATION ± 1% GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 C above a 40 C ambient Insulation is Class F rated at 130 C rise All models are fully prototyped tested ENCLOSURE FEATURES Galvanized steel weather protective enclosure Enclosed critical grade muffler Small, compact, attractive SAE Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. Sound attenuated enclosure ensures quiet operation. ENGINE SPECIFICATIONS MAKE Generac MODEL In line CYLINDERS 4 DISPLACEMENT 1.6 Liter BORE 3.15 STROKE 3.13 COMPRESSION RATIO 9.75:1 INTAKE AIR SYSTEM Naturally Aspirated VALVE SEATS Replaceable LIFTER Hydraulic GOVERNOR SPECIFICATIONS Electronic FREQUENCY REGULATION Isochronous STEADY STATE REGULATION ± 0.% ENGINE LUBRICATION SYSTEM OIL PUMP Gear OIL FILTER Full flow spin-on cartridge CRANKCASE CAPACITY 4 Quarts ENGINE COOLING SYSTEM Closed WATER PUMP Belt driven FAN SPEED 50 FAN DIAMETER 15 inches FAN MODE Pusher FUEL SYSTEM FUEL Natural gas, propane vapor CARBURETOR Down Draft SECONDARY FUEL REGULATOR FUEL SHUT OFF SOLENOID OPERATING FUEL PRESSURE 5-14 H 2 O ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR STATIC BATTERY CHARGER RECOMMENDED BATTERY SYSTEM VOLTAGE 12V 30 Amp 2 Amp Group 26, 5CCA 12 Volts Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271).

Generac Guardian Series Standby Generator - kw OPERATING DATA KW RATING (LP/NG) / ENGINE SIZE 1.6 Liter 4 cyl. inline GENERATOR OUTPUT VOLTAGE/KW - 60Hz KW AMP CB Size 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 0.8 pf 120/240V, 3-phase, 0.8 pf 104 87 75 1 100 90 ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle % of rated load 50% of rated load 75% of rated load 100% of rated load* Natural Gas (ft 3 /hr.) 60 120 220 310 390 Propane (gal/hr.) cu ft/hr 0.7 24 1.3 48 2.4 87 3.4 123 4.3 155 For Btu content, multiply ft 3 /hr x 20 (LP) or ft 3 /hr x 1000 (NG) ENGINE COOLING Air flow (inlet air including alternator and combustion air) System coolant capacity Heat rejection to coolant Max. operating air temp. on radiator Max. ambient temperature COMBUSTION AIR REQUIREMENTS ft 3 /min. US gal. BTU/hr. C ( F) C ( F) 1,528 2.0 110,000 60 (150) 50 (140) Flow at rated power 60 Hz cfm 90 SOUND EMISSIONS IN DBA Exercising at 7 meters Normal operation at 7 meters EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp. at muffler outlet F ENGINE PARAMETERS 62 74 249 1015 Rated synchronous RPM 60 Hz 3600 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration Altitude Deration 3% for every 10 C above - C 1.65% for every 10 F above - F 1% for every 100 m above - m 3% for every 1000 ft. above - ft. 77 183 600 * Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. kw rating is based on LPG Fuel and may derate with natural gas.

INTERCONNECTIONS NEXUS CONTROL FEATURES 2-Line Plain Text LCD Display Simple user interface for ease of operation Mode Switch Automatic Start on Utility failure. 7 day exerciser -Auto -Off Stops unit. Power is removed. Control and charger still operate. -Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds Engine Start Sequence Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration) Engine Warm-up 5 seconds Engine Cool-Down 1 minute Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped. Smart Battery Charger Automatic Voltage Regulation with Over and Under Voltage Protection Automatic Low Oil Pressure Shutdown Overspeed Shutdown, 72Hz High Temperature Shutdown Overcrank Protection Safety Fused Failure to Transfer Protection Low Battery Protection 50 Event Run Log Future Set Capable Exerciser Incorrect Wiring Protection Internal Fault Protection Common External Fault Capability Governor Failure Protection *Single and three phase connections may vary, refer to the owner s manual for specific connection information.

INSTALLATION LAYOUT

AVAILABLE ACCESSORIES Model # Product Description 5819 26R Wet Cell Battery 5629 Cold Weather Kit 5615 Extreme Cold Weather Kit Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product. If the temperature regularly falls below 32 F, install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. Recommended where the temperature regularly falls below 32 F for extended periods of time. For liquid cooled units only. 5651 Base Plug Kit Add base plugs to the base of the generator to keep out debris. 5703 Paint Kit Bisque Kit 5655 Scheduled Maintenance Kit The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform a complete maintenance on Generac liquidcooled generators. 5928 Nexus Wireless Remote Completely wireless and battery powered, Generac's Nexus wireless remote monitor provides you with instant status information without ever leaving the house. 5951 5937 Advanced Nexus Wireless Remote DLM Load Control Module (50 Amps) Remotely control generator functions with the advanced model's LCD display. In addition to remote testing of the generator, set the excercise cycle and maintenance interval reminders DLM Modules are used in conjunction with the Nexus Smart Switch to increase its load management capabilities. It gives the Nexus Smart Switch additional load management flexibility not found in any other transfer switch. Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2011 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0187670SBY-D / Printed in U.S.A. 07/08/11