Alarge portion of kitchen ventilation planning is dedicated to

Similar documents
Optimizing System Performance

Spring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report

Gaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Gaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report

Part 1 of this series discussed optimizing outdoor

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Commercial Kitchen Ventilation Exhaust Hoods

Model ND-2 Specification

Filter Hood Model CA-S

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

KVI Kitchen Canopy With Capture Air

KWF Water Wash Canopy with Supply Air

Design Standard - Fume Hoods & Fume Hood Exhausts

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

EFFECTS OF LOCAL AND GENERAL EXHAUST VENTILATION ON CONTROL OF CONTAMINANTS

KVL-P with Plate Shelf

Kitchen Ventilation Systems. Exhaust Hoods & Grease Extraction Fire Suppression Systems Accessories

Particle size and distribution of oil mist from cooking equipments in electrical commercial kitchens

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

2.6. Air Flow Control Valve Type PRD

Halton - Advanced Air Purification, Now with ELF Extended Life Filters!

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

Commissioning chilled water TES systems

Lab Safety & Energy Optimization. Introduction & Agenda

DIAGNOSTIC TESTING USING ASHRAE 110. Gerhard Knutson, Ph.D., CIH Knutson Ventilation, Inc

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

ExtractAire. Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC)

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

SILENCER SELECTION INSTRUCTIONS

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

Requires Ductwork and Blower

INDOOR ENVIRONMENTAL SOLUTIONS

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

Green Star - Office Interiors v1.1 Inn-3 Environmental Design Initiatives

Experimental Investigation of Hot Surface Ignition of Hydrocarbon-Air Mixtures

Installation, Operation and Maintenance Manual

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

PEIRCE SMITH CONVERTER HOOD IMPROVEMENTS AT BHP COPPER

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

ALD3 Diaphragm Valve Technical Report

Element D Services Heating, Ventilating, and Air Conditioning

Photographer: BRUCE T. MARTIN, LFD Laminar Flow Diffuser

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

LFBC - LATERAL FLOW BIO CONTAINMENT FOR HPAPI PROCESSING FLOW SCIENCES, INC.

ACTIVENT System. Specifications. Product code example ACTA

Proposed Addendum ag to Standard , Ventilation for Acceptable Indoor Air Quality

SILENCER SELECTION INSTRUCTIONS

TABLE OF CONTENTS STANDARDS FOR THE DESIGN, CONSTRUCTION, MAINTENANCE AND USE OF LABORATORY FUME HOODS. Effective August 2010

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

ABSTRACT INTRODUCTION

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Element D Services Heating, Ventilating, and Air Conditioning

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

Sound Application Guide: Description and Ratings

KEES, INC. BALANCING MANUAL

Element D Services Heating Ventilating and Air Conditioning ODG010107

The influence of fuel injection pump malfunctions of a marine 4-stroke Diesel engine on composition of exhaust gases

FXV/CXV & FXV3/CXV3 Layout Guidelines

Thermal Management: Key-Off & Soak

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

General. Technical Bulletin: ACCESSORY INFORMATION

Zoneflow Engineering Installation and Maintenance Manual

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

CONTROLS UPGRADE CASE STUDY FOR A COAL-FIRED BOILER

Viking Installation Guide

FAN POWERED TERMINAL UNITS

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Fabric Pulse Jet Collector Early Designs (Circa 1963)

Laboratory Exhaust Systems

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Development of the Micro Combustor

ASTM D4169 Truck Profile Update Rationale Revision Date: September 22, 2016

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

VAV TERMINAL UNITS. VVD VAV Diffusers

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Commercial Food Service Equipment Specifications for California Investor-Owned Utility-Based Incentives 2015

IMPROVED HIGH PERFORMANCE TRAYS

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

Chapter 4 ANALYTICAL WORK: COMBUSTION MODELING

January, 2014 Page 1 of 6

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

Catalog Swirl diffuser DAL 358

Air Handling Unit Fan Selection Guide

Module 3: Influence of Engine Design and Operating Parameters on Emissions Lecture 14:Effect of SI Engine Design and Operating Variables on Emissions

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Transcription:

By Richard T. Swierczyna, Associate Member ASHRAE, & Paul A. Sobiski, Associate Member ASHRAE Alarge portion of kitchen ventilation planning is dedicated to properly exhausting cooking effluent. Appliance layout and energy input are evaluated, hoods are located and specified, ductwork size and routing are determined, and exhaust fans are specified to remove the proper volume of air. Unfortunately, much less time is usually dedicated to planning how the exhausted volume of air will be replaced, although an air balance schedule is commonly used to indicate the source of the makeup air (MUA). Overlooking MUA delivery system details can have a negative impact on the performance of an otherwise well-designed kitchen. Cross drafts and high air velocities due to improper introduction of MUA can result in failure of the hood to capture and contain effluent from the appliances. This effluent spillage may include convective heat, products of combustion (carbon dioxide, water and potentially carbon monoxide), and products from the cooking process, such as grease vapor and particles, odors, water vapor, and various hydrocarbon gases. Overall commercial kitchen ventilation issues include indoor air quality, fire prevention, safety, employee comfort and equipment first costs, energy operating costs and maintenance costs. This article presents strategies that can minimize the impact that makeup air introduction has on hood performance. To address these MUA issues, a twoyear research project was sponsored by a state government energy agency 1 and large utility. Subsequent testing for several manufacturers augmented this public research initiative. This research project focused on how the introduction of makeup air affects the capture and containment (C&C) performance of commercial food service ventilation equipment. The investigation included combinations of hoods, appliances, cooking conditions, MUA strategies and other factors. Three hood types were tested: wallmounted canopy, island-mounted canopy, and proximity (backshelf). Charbroilers and griddles, representing heavy-duty and medium-duty appliances respectively, were tested during idle and representative cooking conditions. The six MUA strategies included: displacement ventilation (base case), ceiling diffuser, front face diffuser, air curtain diffuser, backwall supply, and short-circuit supply (Figure 1). Certain features of the hoods and local makeup air devices were modified to represent designs and configurations found in commercial kitchen installations, but not necessarily the best or worst designs or configurations. K18 June 2003 Kitchen Ventilation A Supplement to ASHRAE Journal

To determine which MUA strategy offered the most effective operation while providing full capture and containment (C&C), the research team tested the following hypothesis: If the MUA strategy were to have no effect on exhaust hood performance (i.e., equivalent to the displacement ventilation base-case condition), then it would be possible to replace 100% of the air exhausted through the makeup air configuration being investigated, while maintaining C&C. It was conclusively demonstrated that each of the MUA strategies and specific configurations tested compromised the exhaust hood s ability to completely capture and contain the thermal plume and/or effluents at higher makeup airflow rates). Temperature of the locally supplied makeup air also was shown to effect hood performance as air density impacts the dynamics of air movement around the hood. Generally, hotter MUA temperatures (e.g., greater than 90 F [32 C]) will affect hood performance more adversely than cooler air (e.g., less than 75 F [24 C]). Overlooking MUA delivery system details can have a negative impact on the performance of an otherwise well-designed kitchen. C KV System Performance Testing The phrase hood capture and containment is defined in ASTM F1704-99 Standard Test Method for the Performance of Commercial Kitchen Ventilation Systems 2 as the ability of the hood to capture and contain grease-laden cooking vapors, convective heat and other products of cooking processes. Capture and containment performance testing incorporated focusing schlieren and shadowgraph visualization systems to verify capture and containment in accordance with ASTM F1704-99. These technologies are a major breakthrough for visualizing thermal and effluent plumes from cooking processes. A schlieren system presents a high-contrast image of turbulent patterns due to the different air densities within the thermal plume, similar to the effect we see over hot pavement. With appliances at idle (ready-to-cook) condition, C&C evaluation is a relatively simple and repetitive task. A realistic surrogate was needed to produce consistent effluent during cooking C&C evaluations. Since cooking hamburgers provide peak effluent production for approximately 10 seconds during a sixminute cooking session, cooking with hamburgers was used as a baseline condition for cooking plume simulation. For charbroilers, the natural gas flow was increased to match the previously established cooking plume. The cooking plume simulator for the gas griddle was based on spraying water onto the hot cooking surface, using a pressure regulator and timed relay valve for control, and needle valves for fine-tuning. During baseline displacement ventilation C&C tests, the exhaust flow rate was reduced until spillage of the thermal plume was observed. The exhaust flow rate was then increased in fine increments until full C&C was achieved over the test condition. The airflow rate at this condition is referred to as the threshold exhaust airflow rate for complete C&C. These values provided a baseline case to judge the various MUA strategies. Evaluating the performance degradation due to cross drafts required a repeatable and practical disturbance. For this task, a pedestal-mounted fan was located diagonally from the front corner of the hood. For most of the local MUA configurations investigated, the exhaust airflow rate was set initially to the C&C rate determined in the baseline displacement MUA test. The local MUA was then increased (in a balanced room condition) until the threshold of capture and containment was exceeded (i.e., spillage observed). This MUA rate was the airflow rate reported relative to the displacement exhaust C&C rate as the maximum percentage of MUA that could be supplied without impacting hood performance. An exception to the general procedure for local MUA C&C testing was the ceiling four-way diffuser. Testing was performed with constant 1,000 cfm (472 L/s) airflow and modulating the exhaust system to the threshold C&C condition. In addition to the described protocols, MUA rates were incrementally increased to determine the marginal increase in exhaust airflow rate. This procedure led to an exhaust-to-mua ratio determination and index of MUA effect. The following discussion presents research results from the viewpoint of optimizing system performance. Displacement Diffusers Displacement ventilation was the baseline for the study because it provided a uniform, nearly laminar bulk airflow. This low-velocity bulk airflow has proven optimal for attaining C&C Kitchen Ventilation A Supplement to ASHRAE Journal June 2003 K19

Figure 1: Types of MUA supply integrated with the hood. with the lowest exhaust rate. Therefore, supplying makeup air through displacement diffusers as illustrated at right is an effective strategy for introducing replacement air. Unfortunately, displacement diffusers require floor or wall space that is usually at a premium in the commercial kitchen. A possible solution may be remote displacement diffusers (built into a corner) to help distribute the introduction of makeup air into the kitchen when transfer air is not viable. Displacement diffusers Impact of air curtain Air Curtain Supply Most hood manufacturers recommend limiting the percentage of MUA supplied through an air curtain to less than 20% of the hood s exhaust flow. At such low air velocities, an air curtain may enhance C&C depending on design details. However, in the cases tested, the air curtain was the worst performing strategy at higher airflows. The negative impact of an air curtain is clearly illustrated above by the schlieren flow visualization recorded during a test of a wall-mounted canopy hood operating over two underfired broilers. Introducing MUA through an air curtain is a risky option. An air curtain (by itself or in combination with another pathway) is not recommended, unless velocities are kept to a minimum and the designer has access to performance data on the specified air curtain configuration. Typical air curtains are easily adjusted, which could cause cooking effluent to spill into the kitchen by inadvertently creating higher than specified discharge velocities. Short-Circuit Supply (Internal MUA) Internal MUA hoods were developed as a strategy to reduce the amount of conditioned air required by an exhaust system to meet code requirements. This is accomplished by introducing a portion of the untempered makeup air directly into the exhaust hood reservoir. In cold climates, condensation and cooking surface cooling become undesirable side effects. The laboratory testing demonstrated that when short circuit hoods are operated with excessive internal MUA, they fail to capture and contain the cooking effluent, often spilling at the back of the hood (although front spillage is observed in the figure at right). If, however, the specified exhaust rate is higher than the threshold for C&C in an exhaust-only configuration, the short-circuit airflow rate can be increased accordingly, creating a condition of apparent benefit on a percentage basis. For the short circuit configuration tested, the average MUA rate that could be introduced without causing spillage was 15% of the threshold C&C exhaust rate. Front Face Supply Supplying air through the front face of the hood is a configuration recommended by many hood manufacturers. In theory, air exits the front face unit horizontally into the kitchen space. However, a front face discharge with Excessive internal MUA Poorly designed perforated front face supply louvers or perforated face can perform poorly, if its design does not consider discharge air velocity and direction. The figure above represents a poorly designed perforated face supply, which negatively affected this hood s capture performance in the same fashion as an air curtain or four-way diffuser. To improve front face performance, internal baffling and/or a double layer of perforated plates may be used to improve the uniformity of airflow. In addition, greater distance between the lower capture edge of the hood and the bottom of the face discharge area may decrease the tendency of the MUA supply to interfere with hood capture and containment. In general, face discharge velocities should not exceed 150 fpm (0.75 m/s) and should exit the front face in a horizontal direction. Perforated Perimeter Supply Perforated perimeter supply is similar to a front face supply, but the air is directed down- K20 June 2003 Kitchen Ventilation A Supplement to ASHRAE Journal

ward (see figure at right) toward the hood capture area. This may be advantageous under some conditions, since the air is directed downward into the hood capture zone. For proper hood performance, discharge velocities should not exceed 150 fpm (0.75 m/s) from any section of the diffuser and the distance to lower edge of the hood should be no less than 18 in. (0.5 m). If the Perforated perimeter supply air is not introduced in this manner, the system begins to act like an air curtain. An increase in the plenum discharge area lowers the velocity for a given flow of MUA and reduces the chance of it affecting C&C. If the perforated perimeter supply is extended along the sides of the hood as well as the front, the increased area will permit proportionally more MUA to be supplied. Four-Way Ceiling Diffusers Four-way diffusers located close to kitchen exhaust hoods (see figure at right) can have a detrimental effect on hood performance, particularly when the flow through the diffuser approaches its design limit. Four-way diffusers Perforated plate ceiling diffusers can be used in the vicinity of the hood, and a greater number of ceiling diffusers reduce air velocities for a given supply rate. To help ensure proper hood performance, air from a diffuser within the vicinity of the hood should not be directed toward the hood. If ceiling supplied air must be directed toward a hood, the air discharge velocity at the diffuser face should be set at a design value such that the terminal velocity does not exceed 50 fpm (0.25 m/s) at the edge of the hood capture area. Backwall Supply The lab testing demonstrated that the backwall supply can be an effective strategy for introducing MUA (see figure at right). For the backwall supply tested with a canopy hood, the average MUA rate that could be Backwall supply introduced without causing spillage was 46% of the threshold C&C exhaust rate. To help ensure proper performance, the discharge of the backwall supply should be at least 12 in. (0.3 m) below the cooking surfaces of the appliances to prevent the relatively high velocity introduction of MUA from interfering with gas burners and pilot lights. Backwall plenums with larger discharge areas may provide increased airflow rates as long as discharge velocities remain below maximum thresholds. Ideally, the quantity of air introduced through the backwall supply should be no more than 60% of the hood s exhaust flow. Other Factors that Influence Hood Performance Hood Style. Wall-mounted canopy hoods function effectively with a lower exhaust flow rate than single-island hoods. Island canopy hoods are more sensitive to MUA supply and cross drafts than wall-mounted canopy hoods. Proximity hoods exhibit lower C&C exhaust rates, and in some cases, perform the same job at one-third of the exhaust rate required by a wall-mounted hood. Cross Drafts. Cross drafts have a detrimental effect on all hood/appliance combinations, and adversely affect island canopy hoods more than wall-mounted canopy hoods. A fan in a kitchen, especially pointing at the cooking area, severely degrades hood performance and may make capture impossible. Cross drafts required at least a 37% increase in exhaust flow rate and in some cases C&C could not be achieved with a 235% increase in exhaust rate. Cross drafts can result from portable fans, movement in the kitchen, or an unbalanced HVAC system. Side Panels and Overhang. Side (or end) panels permit a reduced exhaust rate in most cases, as they direct the replacement airflow to the front of the hood. The installation of side panels improved C&C performance for static conditions an average of 10% to 15% and up to 35% for dynamic (cross-draft) conditions. They are a relatively inexpensive way to achieve C&C performance and reduce the total exhaust rate. Partial side panels are able to provide virtually the same benefit as full panels. One of the greatest benefits of side panels is to mitigate the negative effect of cross drafts. An increase in overhang may increase the ability to contain large volume surges from cooking processes that use convection and combination ovens, steamers and pressure fryers, although for unlisted hoods this may mean an increase in the code-required exhaust rate. MUA Strategy and C&C Exhaust Rate What was not anticipated during the design of the study was how sensitive the C&C threshold would be to the local introduction of MUA. Spill conditions often were observed when as little as 10% of the exhaust rate was supplied by a given MUA strategy. Figure 2 shows a generic trend for changes in exhaust airflow rate as MUA flow rate increases for a given hood/mua system. In this generic graph, the C&C exhaust flow rate is 3,000 cfm (1400 L/s) with no locally supplied MUA. For local MUA up to 500 cfm (236 L/s), the system did not require an increase in the exhaust rate, as represented by the horizontal part of the curve. When the MUA was increased beyond the 500 cfm (236 L/s), the exhaust rate had to increase to maintain C&C. For this particular hood/mua system, every 1 cfm (0.47 L/s) increase in MUA required a 0.75 cfm (0.35 L/s) increase in exhaust rate. In the better performing MUA strategies, more local MUA can be introduced without increasing the exhaust rate to maintain C&C. Conclusions The primary recommendation to reduce the impact that locally supplied MUA may have on hood performance is to mini- Kitchen Ventilation A Supplement to ASHRAE Journal June 2003 K21

Advertisement in the print edition formerly in this space. mize the velocity (fpm) of the makeup air as it is introduced near the hood. This can be accomplished by minimizing the volume (cfm) of makeup air through any single distribution system, by maximizing the area of the diffusers through which the MUA is supplied, or by distributing through multiple pathways. Makeup air that is supplied through displacement ventilation diffusers, perforated diffusers located in the ceiling as far as possible from the hood, or as transfer air from the dining room generally works well if air velocities approaching the hood are less than 75 fpm (0.25 m/s). However, makeup air introduced close to an exhaust hood has the potential to interfere with the hood s ability to capture and contain. The chances of makeup air affecting hood performance increases as the percentage of the locally supplied MUA (relative to the total exhaust) is increased. In fact, the 80% rule-of-thumb for sizing airflow through an MUA system may be a recipe for trouble. The first step to reducing the MUA requirement is to lower the design exhaust rate. This can be accomplished by prudent selection and application of UL-listed hoods. 3 The use of side and/or back panels on canopy hoods to increase effectiveness, mitigate cross drafts and reduce heat gain is highly recommended. The next step in reducing MUA flow is to take credit for outside air that must be supplied by the HVAC system to meet code requirements for ventilating the dining room. Depending on the architectural layout, it may be practical to transfer most of this air to the kitchen. Although this may contradict past practice, the hood performance will be superior and the kitchen environment will benefit from the contribution of the conditioned dining room air. References 1. Brohard, G., et al. 2003. Makeup Air Effects on Kitchen Exhaust Hood Performance. California Energy Commission, Sacramento, Calif. 2. ASTM. 1999. Test Method for Performance of Commercial Kitchen Ventilation Systems. Standard F 1704-99. American Society for Testing and Materials, West Conshohocken, Pa. 3. 1999 ASHRAE Handbook HVAC Applications. Chapter 30, Kitchen Ventilation. Richard T. Swierczyna is the lab operations manager and Paul A. Sobiski is a research engineer at Architectural Energy in Wood Dale, Ill. K22 June 2003 Kitchen Ventilation A Supplement to ASHRAE Journal Exhaust Airflow Rate (cfm) 6,500 5,500 4,500 3,500 2,500 1,500 MUA Has More of an Effect on Hood Performance MUA Introduction with No Effect on C&C C&C for Exhaust Only Condition MUA Has Less of an Effect on Hood Performance 500 0 0 1,000 2,000 3,000 4,000 5,000 Makeup Airflow Rate (cfm) Figure 2: Potential impact of MUA on exhaust flow rates.