Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures

Similar documents
and Refrigeration Institute). CNX Special Purpose Contactors

Orange Express Selection Guide Table of Contents

General + Definite Purpose Contactors

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

Power electronic brakes

Definite Purpose Contactors

Contactors & Starters Index

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

Starters + Enclosed Product

Rotary Cam Switches. Rotary Cam Switches

Series L9 UL-489 Miniature Circuit Breakers

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

E C N A A F -

Motor Controllers + Circuit Breakers

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

AF series contactors (9 2650)

Series L9 UL489 Miniature Circuit Breakers

Type E/F Simplex & Duplex Pump Controllers

Accessories - Field Installable

Intelligent Softstarter Controllers

AF series contactors (9 2650)

6.1. Lighting Contactors. Contents. Application Description. Product Overview. Open Control

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

Technical Information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs

Series CA6 Contactors

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

D I D /240 I. D x /240 I D / x x /24 I. D x /120

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Series CA5 Contactors

TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

NEMA Contactors and Starters

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th

NEMA Contactors & Starters (Freedom)

IEC Utilization Categories (Explanation)

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Technical Information

Selection Guide Motor Control Device Solutions

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

Industrial Control Transformers

OTEC Transfer switch open transition

Industrial Power Resistors Euclid Type SSR 1.3 to 101 Amperes

XT SERIES Jockey Pump Controllers Features

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Rotary Cam Switches. Rotary Cam Switches

General + Definite Purpose Contactors

Baldor Basics: Motors

Industrial Contactors CTX 3 3P 185A - 800A

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family

EPS-ECONOMY PUMP STARTER

Series CA7 Contactors

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Series CA6 Contactors

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Magnetic Motor Controls

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

C E R T I F I C A T E O F C O M P L I A N C E

Variable Frequency AC Motor Drive Units

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

NEMA Contactors and Starters

R-Rated medium voltage fuses for motor circuit protection

CI-TI Contactors and motor starters Types CI 61 - CI 98

4 - Miniature controls

Bussmann series Quik-Spec Coordination Panelboard

Softstarters. Softstarters Power electronic brakes Type PEB

Single Socket and Horizontal Metering

KT4 Manual Motor Starter

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Ideal for use as a manual starter

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

FJ303-3PB6B. 4X Plastic 12. Catalog List Catalog List number price number price

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection...

KT4 Manual Motor Starters

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

Vacuum Contactors and Starters

Motorized Systems for Interior Window Coverings 2014

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

9070T150D1 Industrial Control Transformer, 150VA

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

For many applications

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

US Catalog. Motor protection and control AF Range contactors & overload relays

Motorized Systems for Interior Window Coverings 2005

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Catalog Number Description

Catalog Number Description

2017 CATALOG East Main Street Mesa, AZ

Transcription:

Enclosed ontactors Sprecher + Schuh s popular contactor lines housed in a variety of enclosures Sprecher + Schuh s broad line of E/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. ataloged enclosures include: 2 Type 3R ndustrial usttight Raintight (outdoor) X, orrosion Resistant Non-etallic Even though these are the most popular enclosure types for most industrial applications, we can house any contactor in a custom enclosure of your choice. Quality enclosures ensure the highest confidence Sprecher + Schuh only sources enclosures from name brand manufacturers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e.,, Type 3R, etc., however, we can also source E-type enclosures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer sufficient electrical clearances to satisfy UL. Add a variety of modifications f you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineering department will work with you to customize any of our enclosed products to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need. Precisely match the contactor to the application Unique to E-style contactors is the ability to select the exact device required for a specific application. By identifying the conditions under which the contactor will be used, i.e., resistive loads, reversing, inching and plugging, etc., published life-curve data predicts contact life in millions of operations. This information enables you to select the precise contactor for your application without buying too much or too little. Refer to Section A in this catalog for detailed technical information on all Sprecher + Schuh contactors. Other unique features Virtually all Sprecher+Schuh contactors offer one or more of the latest design techniques and innovations, such as electronically controlled coils, field installable auxiliary contacts or universal accessories across the entire contactor family. Type 3R X 35

- A oil Non-Reversing - Series A, Non-Reversing A7 & A9 - UL/SA - aximum Horsepower 2 [Type 3R ➋] ndustrial usttight Enclosed 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ 25 2 2 5 7.5 1 0 A7-9- -G0 211 A A7-9- -0 309 L 25 3 3 7.5 10 1 0 A7-12- -G0 244 A A7-12- -0 341 L 30 5 5 10 15 1 0 A7-16- -G0 259 A A7-16- -0 356 L 30 5 7.5 15 15 1 0 A7-23- -G0 276 A A7-23- -0 374 L 55 7.5 10 20 25 1 0 A7-30- -G0 324 A A7-30- -0 422 L 60 10 10 25 30 1 0 A7-37- -G0 365 A A7-37- -0 463 L 75 10 15 30 30 1 0 A7-43- -G0 520 A A7-43- -0 552 L 75 15 20 40 40 1 0 A7-55- -G0 540 A A7-55- -0 576 L 90 15 20 40 50 1 0 A7-60- -G0 560 B A7-60- -0 600 90 20 25 50 60 1 0 A7-72- -G0 617 B A7-72- -0 649 100 25 30 60 60 1 0 A7-85- -G0 674 B A7-85- -0 715 120 30 30 75 75 1 0 A7-97- -G0 848 B A7-97- -0 890 O 116 30 40 75 100 1 1 A9-116- -G0 ➍ 1424 E A9-116- -0 ➍ 1592 Q 146 40 50 100 125 1 1 A9-146- -G0 ➍ 1652 E A9-146- -0 ➍ 1847 Q 190 50 60 125 150 1 1 A9-190- -G0 ➍ 1938 E A9-190- -0 ➍ 2386 R 205 60 75 150 200 1 1 A9-205- -G0 ➍ 2601 F A9-205- -0 ➍ 3290 T 265 75 100 200 250 1 1 A9-265- -G0 ➍ 2775 F A9-265- -0 ➍ 3429 T 305 100 125 250 300 1 1 A9-305- -G0 ➍ 3272 H A9-305- -0 ➍ 3740 H 370 125 150 300 350 1 1 A9-370- -G0 ➍ 3763 H A9-370- -0 ➍ 4300 H 400 125 150 350 400 1 1 A9-400-E- -G0 5020 R/F A9-400-E- -0 5428 R/F 460 150 200 400 500 1 1 A9-460-E- -G0 6075 R/F A9-460-E- -0 6568 R/F 480 200 250 500 600 1 1 A9-580-E- -G0 7897 R/F A9-580-E- -0 8538 R/F 750 250 300 600 700 1 1 A9-750-E- -G0 10345 R/F A9-750-E- -0 11185 R/F 860 ~ 400 800 1000 1 1 A9-860-E- -G0 13966 R/F A9-860-E- -0 15099 R/F 1060 ~ 450 900 1150 1 1 A9-1060-E- -G0 15642 R/F A9-1060-E- -0 16911 R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example catalog number A7-23- -0 becomes A7-23- -R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ A9-116 A9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: A9-116- -G0 becomes A9-116-E- -G0. See page 104 for price adder. 36 iscount Schedule B7

- A oil Non-Reversing - Series A, Non-Reversing A7 & A9 - UL/SA - aximum Horsepower ontactor ➋ X orrosion Resistant Enclosed 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ 25 2 2 5 7.5 1 0 A7-9- -W0 446 N A7-9- -0 333- S1 25 3 3 7.5 10 1 0 A7-12- -W0 479 N A7-12- -0 365 S1 30 5 5 10 15 1 0 A7-16- -W0 495 N A7-16- -0 381 S1 30 5 7.5 15 15 1 0 A7-23- -W0 513 N A7-23- -0 398 S1 55 7.5 10 20 25 1 0 A7-30- -W0 560 N A7-30- -0 446 S1 60 10 10 25 30 1 0 A7-37- -W0 600 N A7-37- -0 487 S1 75 10 15 30 30 1 0 A7-43- -W0 617 N A7-43- -0 503 S1 75 15 20 40 40 1 0 A7-55- -W0 653 N A7-55- -0 539 S1 90 15 20 40 50 1 0 A7-60- -W0 754 O A7-60- -0 657 U1 90 20 25 50 60 1 0 A7-72- -W0 811 O A7-72- -0 715 U1 100 25 30 60 60 1 0 A7-85- -W0 869 O A7-85- -0 771 U1 120 30 30 75 75 1 0 A7-97- -W0 985 O A7-97- -0 947 U1 116 30 40 75 100 1 1 A9-116- -W0 ➍ 2011 Q A9-116- -0 ➍ 1810 W2 146 40 50 100 125 1 1 A9-146- -W0 ➍ 2333 Q A9-146- -0 ➍ 2100 W2 190 50 60 125 150 1 1 A9-190- -W0 ➍ 2565 R A9-190- -0 ➍ 3429 X1 205 60 75 150 200 1 1 A9-205- -W0 ➍ 3412 T A9-205- -0 ➍ 4387 X1 265 75 100 200 250 1 1 A9-265- -W0 ➍ 3545 T A9-265- -0 ➍ 4469 X1 305 100 125 250 300 1 1 A9-305- -W0 ➍ 4206 H A9-305- -0 ➍ 5297 Y1 370 125 150 300 350 1 1 A9-370- -W0 ➍ 4837 H A9-370- -0 ➍ 6092 Y1 400 125 150 350 400 1 1 A9-400-E- -W0 5834 R/F A9-400-E- -0 6785 R/F 460 150 200 400 500 1 1 A9-460-E- -W0 7060 R/F A9-460-E- -0 8209 R/F 480 200 250 500 600 1 1 A9-580-E- -W0 9178 R/F A9-580-E- -0 10672 R/F 750 250 300 600 700 1 1 A9-750-E- -W0 12023 R/F A9-750-E- -0 13980 R/F 860 ~ 400 800 1000 1 1 A9-860-E- -W0 16231 R/F A9-860-E- -0 18874 R/F 1060 ~ 450 900 1150 1 1 A9-1060-E- -W0 18178 R/F A9-1060-E- -0 21138 R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ A9-116 A9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: A9-116- -W0 becomes A9-116-E- -W0. See page 104 for price adder. iscount Schedule B7 37

- A oil Reversing - Series AU, Reversing AU7 & AU9 - UL/SA - aximum Horsepower 2 [Type 3R ➋] ndustrial usttight Enclosed 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ 25 2 2 5 7.5 1 1 AU7-9- -G0 562 A AU7-9- -0 619 25 3 3 7.5 10 1 1 AU7-12- -G0 633 A AU7-12- -0 682 30 5 5 10 15 1 1 AU7-16- -G0 674 A AU7-16- -0 722 30 5 7.5 15 15 1 1 AU7-23- -G0 692 A AU7-23- -0 766 55 7.5 10 20 25 1 1 AU7-30- -G0 807 A AU7-30- -0 855 60 10 10 25 30 1 1 AU7-37- -G0 888 A AU7-37- -0 1010 75 10 15 30 30 1 1 AU7-43- -G0 953 B AU7-43- -0 1076 75 15 20 40 40 1 1 AU7-55- -G0 1024 B AU7-55- -0 1147 90 15 20 40 50 1 1 AU7-60- -G0 1271 AU7-60- -0 1296 O 90 20 25 50 60 1 1 AU7-72- -G0 1385 AU7-72- -0 1410 O 100 25 30 60 60 1 1 AU7-85- -G0 1491 AU7-85- -0 1515 O 120 30 30 75 75 1 1 AU7-97- -G0 1723 AU7-97- -0 1748 O 116 30 40 75 100 1 1 AU9-116- -G0 ➎ 2681 E AU9-116- -0 ➎ 2848 Q 146 40 50 100 125 1 1 AU9-146- -G0 ➎ 3110 E AU9-146- -0 ➎ 3304 Q 190 50 60 125 150 1 1 AU9-190- -G0 ➎ 3877 E AU9-190- -0 ➎ 4175 R 205 60 75 150 200 1 1 AU9-205- -G0 ➎ 5362 F AU9-205- -0 ➎ 5850 T 265 75 100 200 250 1 1 AU9-265- -G0 ➎ 5702 F AU9-265- -0 ➎ 6165 T 305 100 125 250 300 1 1 AU9-305- -G0 ➎ 6387 H AU9-305- -0 ➎ 6855 H 370 125 150 300 350 1 1 AU9-370- -G0 ➎ 7345 H AU9-370- -0 ➎ 7883 H 400 125 150 350 400 1 1 AU9-400-E- -G0 10312 R/F AU9-400-E- -0 10719 R/F 460 150 200 400 500 1 1 AU9-460-E- -G0 12478 R/F AU9-460-E- -0 12970 R/F 480 200 250 500 600 1 1 AU9-580-E- -G0 16221 R/F AU9-580-E- -0 16861 R/F 750 250 300 600 700 1 1 AU9-750-E- -G0 21249 R/F AU9-750-E- -0 22087 R/F 860 ~ 400 800 1000 1 1 AU9-860-E- -G0 28687 R/F AU9-860-E- -0 29818 R/F 1060 ~ 450 900 1150 1 1 AU9-1060-E- -G0 32129 R/F AU9-1060-E- -0 33396 R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example catalog number AU7-23- -0 becomes AU7-23- -R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➎ AU9-116 AU9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: AU9-116- -G0 becomes AU9-116-E- -G0. See page 104 for price adder. 38 iscount Schedule B7

- A oil Reversing - Series AU, Reversing AU7 & AU9 - UL/SA - aximum Horsepower ontactor ➋ X orrosion Resistant Enclosed 200V 230V 460V 575V NO N ➌ atalog Number Price ➊ atalog Number Price ➊ 25 2 2 5 7.5 1 1 AU7-9- -W0 668 N AU7-9- -0 652 U1 25 3 3 7.5 10 1 1 AU7-12- -W0 733 N AU7-12- -0 717 U1 30 5 5 10 15 1 1 AU7-16- -W0 774 N AU7-16- -0 757 U1 30 5 7.5 15 15 1 1 AU7-23- -W0 814 N AU7-23- -0 798 U1 55 7.5 10 20 25 1 1 AU7-30- -W0 904 N AU7-30- -0 888 U1 60 10 10 25 30 1 1 AU7-37- -W0 1059 N AU7-37- -0 978 U1 75 10 15 30 30 1 1 AU7-43- -W0 1124 N AU7-43- -0 1043 U1 75 15 20 40 40 1 1 AU7-55- -W0 1196 N AU7-55- -0 1114 U1 90 15 20 40 50 1 1 AU7-60- -W0 1320 O AU7-60- -0 1997 V1 90 20 25 50 60 1 1 AU7-72- -W0 1434 O AU7-72- -0 2119 V1 100 25 30 60 60 1 1 AU7-85- -W0 1540 O AU7-85- -0 2216 V1 120 30 30 75 75 1 1 AU7-97- -W0 1772 O AU7-97- -0 2449 V1 116 30 40 75 100 1 1 AU9-116- -G0 ➍ 3282 Q AU9-116- -0 ➍ 3030 W2 146 40 50 100 125 1 1 AU9-146- -G0 ➍ 3807 Q AU9-146- -0 ➍ 3515 W2 190 50 60 125 150 1 1 AU9-190- -G0 ➍ 4569 R AU9-190- -0 ➍ 5692 X1 205 60 75 150 200 1 1 AU9-205- -G0 ➍ 6490 T AU9-205- -0 ➍ 7348 X1 265 75 100 200 250 1 1 AU9-265- -G0 ➍ 6775 T AU9-265- -0 ➍ 7317 X1 305 100 125 250 300 1 1 AU9-305- -G0 ➍ 7357 H AU9-305- -0 ➍ 8532 Y1 370 125 150 300 350 1 1 AU9-370- -G0 ➍ 8461 H AU9-370- -0 ➍ 9812 Y1 400 125 150 350 400 1 1 AU9-400-E- -G0 11180 R/F AU9-400-E- -0 12063 R/F 460 150 200 400 500 1 1 AU9-460-E- -G0 13528 R/F AU9-460-E- -0 14596 R/F 480 200 250 500 600 1 1 AU9-580-E- -G0 2831 R/F AU9-580-E- -0 18974 R/F 750 250 300 600 700 1 1 AU9-750-E- -G0 3709 R/F AU9-750-E- -0 24856 R/F 860 ~ 400 800 1000 1 1 AU9-860-E- -G0 5007 R/F AU9-860-E- -0 33556 R/F 1060 ~ 450 900 1150 1 1 AU9-1060-E- -G0 5608 R/F AU9-1060-E- -0 37583 R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➍ AU9-116 AU9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: AU9-116- -W0 becomes AU9-116-E- -W0. See page 104 for price adder. iscount Schedule B7 39

- A oil Non-Reversing Single Phase - Series B Single Phase, Non-Reversing B7 - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ B7- B7- B7- B7-25 1/2 1 1/2 1 0 9- -G0 211 A 9- -0 309 L 9- -W0 446 N 9- -0 304 S1 25 1/2 2 1 0 12- -G0 244 A 12- -0 341 L 12- -W0 479 N 12- -0 365 S1 30 1 3 1 0 16- -G0 259 A 16- -0 356 L 16- -W0 495 N 16- -0 381 S1 30 2 3 1 0 23- -G0 276 A 23- -0 374 L 23- -W0 513 N 23- -0 398 S1 55 2 5 1 0 30- -G0 324 A 30- -0 422 L 30- -W0 560 N 30- -0 446 S1 60 3 5 1 0 37- -G0 365 A 37- -0 463 L 37- -W0 600 N 37- -0 487 S1 75 3 7 1/2 1 0 43- -G0 520 A 43- -0 552 L 43- -W0 617 N 43- -0 503 S1 75 5 10 1 0 55- -G0 540 A 55- -0 576 L 55- -W0 653 N 55- -0 539 S1 90 5 10 1 0 60- -G0 560 B 60- -0 600 60- -W0 754 O 60- -0 657 U1 90 5 15 1 0 72- -G0 617 B 72- -0 649 72- -W0 811 O 72- -0 715 U1 100 7 1/2 15 1 0 85- -G0 674 B 85- -0 715 85- -W0 869 O 85- -0 771 U1 Larger sizes. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example catalog number B7-23- -0 becomes B7-23- -R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 40 iscount Schedule B7

- A oil Reversing Single Phase - Series BU Single Phase, Reversing BUR7 (Reconnectable Winding - Three Lead otor) - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUR BUR BUR BUR 25 1/2 1 1/2 1 1 7-9- -G0 562 A 7-9- -0 619 7-9- -W0 668 N 7-9- -0 652 U1 25 1/2 2 1 1 7-12- -G0 635 A 7-12- -0 685 7-12- -W0 733 N 7-12- -0 717 U1 30 1 3 1 1 7-16- -G0 676 A 7-16- -0 725 7-16- -W0 774 N 7-16- -0 757 U1 30 2 3 1 1 7-23- -G0 692 A 7-23- -0 766 7-23- -W0 814 N 7-23- -0 798 U1 55 2 5 1 1 7-30- -G0 807 A 7-30- -0 855 7-30- -W0 904 N 7-30- -0 888 U1 Single Phase, Reversing BUS7 (Series Winding Four Lead Repulsion nduction otor) - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUS BUS BUS BUS 25 1/2 1 1/2 1 1 7-9- -G0 562 A 7-9- -0 619 7-9- -W0 668 N 7-9- -0 652 U1 25 1/2 2 1 1 7-12- -G0 635 A 7-12- -0 685 7-12- -W0 731 N 7-12- -0 717 U1 30 1 3 1 1 7-16- -G0 676 A 7-16- -0 725 7-16- -W0 774 N 7-16- -0 757 U1 30 2 3 1 1 7-23- -G0 692 A 7-23- -0 766 7-23- -W0 814 N 7-23- -0 798 U1 55 2 5 1 1 7-30- -G0 807 A 7-30- -0 855 7-30- -W0 904 N 7-30- -0 888 U1 Single Phase, Reversing BUP7 (Parallel Winding Four Lead apacitor or Split Phase otor) - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUP BUP BUP BUP 25 1/2 1 1/2 1 1 7-9- -G0 562 A 7-9- -0 619 7-9- -W0 668 N 7-9- -0 652 U1 25 1/2 2 1 1 7-12- -G0 635 A 7-12- -0 685 7-12- -W0 731 N 7-12- -0 717 U1 30 1 3 1 1 7-16- -G0 676 A 7-16- -0 725 7-16- -W0 774 N 7-16- -0 757 U1 30 2 3 1 1 7-23- -G0 692 A 7-23- -0 766 7-23- -W0 814 N 7-23- -0 798 U1 55 2 5 1 1 7-30- -G0 807 A 7-30- -0 855 7-30- -W0 904 N 7-30- -0 888 U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number BUx7-23- -0 becomes BUx7-23- -R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On BU reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). iscount Schedule B7 41

NEA - A oil Non-Reversing - Series AN7, Non-Reversing AN7 NEA Size aximum Horsepower 2 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ 00 3 3 7.5 10 1 0 AN7-12- -G0 384 A AN7-12- -0 537 L 0 5 5 10 15 1 0 AN7-16- -G0 409 A AN7-16- -0 561 L 1 10 10 25 30 1 0 AN7-37- -G0 575 A AN7-37- -0 729 L 2 10 15 30 30 1 0 AN7-43- -G0 819 A AN7-43- -0 869 L 3 25 30 60 60 1 0 AN7-85- -G0 1061 B AN7-85- -0 1125 NEA Size aximum Horsepower X orrosion Resistant 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ 00 3 3 7.5 10 1 0 AN7-12- -W0 755 N AN7-12- -0 575 S1 0 5 5 10 15 1 0 AN7-16- -W0 779 N AN7-16- -0 601 S1 1 10 10 25 30 1 0 AN7-37- -W0 946 N AN7-37- -0 767 S1 2 10 15 30 30 1 0 AN7-43- -W0 971 N AN7-43- -0 793 S1 3 25 30 60 60 1 0 AN7-85- -W0 1368 O AN7-85- -0 1214 U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AN7-23- -0 becomes AN7-23- -R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 42 iscount Schedule B8

NEA - A oil Reversing - Series AUN7, Reversing AUN7 NEA Size aximum Horsepower 2 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ 00 3 3 7.5 10 1 1 AUN7-12- -G0 997 A AUN7-12- -0 1074 0 5 5 10 15 1 1 AUN7-16- -G0 1061 A AUN7-16- -0 1138 1 10 10 25 30 1 1 AUN7-37- -G0 1368 A AUN7-37- -0 1591 2 10 15 30 30 1 1 AUN7-43- -G0 1501 B AUN7-43- -0 1694 3 25 30 60 60 1 1 AUN7-85- -G0 2349 AUN7-85- -0 2387 O NEA Size aximum Horsepower X orrosion Resistant 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ 00 3 3 7.5 10 1 1 AUN7-12- -W0 1154 N AUN7-12- -0 1129 U1 0 5 5 10 15 1 1 AUN7-16- -W0 1218 N AUN7-16- -0 1193 U1 1 10 10 25 30 1 1 AUN7-37- -W0 1668 N AUN7-37- -0 1540 U1 2 10 15 30 30 1 1 AUN7-43- -W0 1771 N AUN7-43- -0 1642 U1 3 25 30 60 60 1 1 AUN7-85- -W0 2425 O AUN7-85- -0 3491 V1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page 104 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AUN7-23- -0 becomes AUN7-23- -R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). iscount Schedule B8 43

Enclosed Lighting ontactors - A oil - Series AL / AVL Electrically Held with A oil Ampere Rating ➌ See page A46 Number of Poles Standard ontacts ➎ NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. 2 [Type 3R ➏] ndustrial usttight NO N atalog Number Price ➍ atalog Number Price ➍ 4 0 0 AL7-20-40- -G0 414 A AL7-20-40- -0 561 L 4 0 0 AL7-30-40- -G0 588 A AL7-30-40- -0 735 L 4 0 0 AL7-60-40- -G0 980 B AL7-60-40- -0 1041 echanically Held with A oil ➊ Ampere Rating ➌ Number of Poles Standard ontacts ➎ 2 [Type 3R ➏] ndustrial usttight NO N atalog Number Price ➍ atalog Number Price ➍ 4 0 0 AVL7-20-40- -G0 R/F R/F AVL7-20-40- -0 R/F R/F See page 4 0 0 AVL7-30-40- -G0 R/F R/F AVL7-30-40- -0 R/F R/F A46 4 0 0 AVL7-60-40- -G0 R/F R/F AVL7-60-40- -0 R/F R/F Larger sizes. ontact your Sprecher + Schuh representative. escription The AL7 electrically held contactors and AVL7 mechanical held contactors are cul rated and labeled for tungsten and ballast lighting duty applications at 20, 30, and 60 amperes respectively. Operation of echanically Held ontactor with ON-OFF Pushbutton atalog number AVL7 consists of a AL7 contactor with V7-11 mechanical latch. epressing the ON button energizes the L coil and the contactor closes. The mechanical latch locks the contactor in the closed position. The L coil is then de-energized by the coil, clearing contact UL (Terminals 65-66) to remove voltage. epressing the OFF button energizes the UL coil, and the mechanical latch releases the contactor. The UL coil is immediately de-energized by the coil clearing contact L (Terminals 13-14) to remove voltage. The contactor is now open. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications 44 Refer to page 104 107-111 ➊ The N.O. auxiliary is used to mechanically latch the control circuit and is not for use by customer for other uses. ➌ Engineering practice permits 2.5 x e to be applied to a contactor when 3 poles are connected in parallel for single phase discharge lamp (ballast lighting) applications. Example: A AL7-20-40- Lighting ontactor plus a A7-P-B23 Paralleling Link can be used on a 50A ballast load. Applying parallel conductors to incandescent lamp loads does NOT result in a greater permissible load. Paralleling Links can be found in the Accessories section. ➍ imensional information starts on page 122. ➎ ontactors are equipped with number and type of auxiliaries indicated. See 108 to order additional or different auxiliary contacts. ➏ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example: AL7-20-40- -0 becomes AL7-20-40- -R0. Price remains the same. iscount Schedule B7