MANUAL INSTALLATION. Modular Floor Diffusers. MFD Series. v102 Issue Date: 03/23/ Price Industries Limited. All rights reserved.

Similar documents
MANUAL INSTALLATION. Linear Plenum Terminal. LPT Series. v001 Issue Date: 06/06/ Price Industries Limited. All rights reserved.

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

WATER COOLED AIR CONDITIONING UNITS MODEL CVWSEK-060 WATER SIDE ECONOMIZER FOR CSV060B VERTICAL R-410A STYLE B R-410A

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

Ceiling swirl diffusers

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

E3-22. FDD Round Diffuser, Displacement Air Pattern. Introduction: FDD UNDERFLOOR PRODUCTS F D D

UNDERFLOOR PRODUCTS E3

RPD ROUND PLAQUE DIFFUSER

Installation, Operation & Maintenance

Ceiling swirl diffusers

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Ceiling swirl diffusers

INSTALLATION AND OPERATING INSTRUCTIONS

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

Price O.R. Systems AIR CURTAIN SYSTEM

Installation Instructions

Installation Instructions

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

MODELS SSS 7L-B, 14L-B, 26L-B, 33L-B AND MODELS SSS 7LK-B, 14LK-B, 26LK-B, 33LK-B

CEILING SPEAKER SYSTEM

RSD Series Radial Slot Diffuser

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

SECTION AIR TERMINAL UNITS

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

VAV TERMINAL UNITS. VVD VAV Diffusers

Installing the Switch Chassis

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

Installing the ONS M6 Shelf

series Linear grilles

MODULAR CORE CEILING DIFFUSERS

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

Slot diffusers, Round duct diffusers. IMP Klima

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Installation Instructions

University of Delaware

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

SolarSheat Wall Installation Manual

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Installation Instructions

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

ACCUSTATION SUBMITTAL MATERIALS

makes sure products are delivered Products are offered in steel,

Installation Instructions

ATP-2040 Electric Damper Actuator/Transmitter

SolarSheat Wall Installation Manual

HIGH FLOW COLD AIR INTAKE SYSTEM INSTALLATION INSTRUCTIONS D , D A

Installation Instructions

Variable Air Volume (VAV) Pressure Independent Control

GDD - Supply Grille. Halton GDD. Supply Grille

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

INSTALLATION INSTRUCTIONS FOR COZY CAB A-1 AIR CONDITIONING KIT

Ventiduct nozzle ducts

Invensys Energy Solutions 1354 Clifford Avenue (Zip 61111) P.O. Box 2940 Loves Park, IL United States of America

READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

Installation Instructions

FIELD CONNECTIONS MODEL YK CHILLERS (STYLE F AND G) WITH VARIABLE SPEED DRIVE

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Installation Instructions for Chevrolet C5 Corvette Lingenfelter High Flow Fuel Pump Module

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

SPD SQUARE PLAQUE DIFFUSER

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

ACTIVE CHILLED BEAM 6 1/4" HEATING 9 1/2" DISCHARGE DIRECTION. 1 7/8" u 1/4" NOZZLE SIZE:

WIRING DIAGRAMS MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH SSS, LV VSD W/ MODBUS, & MV VSD

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

Ventilation grilles for installation into walls, sills or rectangular

TBS100FC CASE SEALER DESCRIPTION AND SET UP PROCEDURES

FOR OT/HT MODEL CHILLERS STYLE B AND C CONTROL CENTERS , AND

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

Instant Chat off the main page of Or simply call our tech team at

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

PRODUCT BROCHURE. Adjustable Helical Swirl Diffuser HSC-AD HSC-AD : smartemp.com

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

The H-MAC Heavy Metal Articulating Chassis Construction Guide

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

WATER-COOLED SELF-CONTAINED UNITS MODEL CVWSEK-060BK/DP WATERSIDE ECONOMIZER FOR CSV060B LEFT-HAND VERTICAL R-410A STYLE B

Installation Instructions

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Trackstar Motorized Folding Shade Installation Instructions

Renogy MTS-TM100. Flat Roof Tilt Mount E Philadelphia St, Ontario, CA Version: 1.1

Model 858-RH. Operating and Assembly Manual. Palmor Products Inc Serum Plant Road Thorntown, IN 46071

Transcription:

MANUAL INSTALLATION Modular Floor Diffusers MFD Series v102 Issue Date: 03/23/18 2018 Price Industries Limited. All rights reserved.

TABLE OF CONTENTS General Overview Introduction...1 General Safety Guidelines...1 Safety Symbols...1 System Overview Interior Zones...2 Product Overview Modular Floor Diffusers...3 Diffuser Face Options...4 Mounting Ring Options...4 Basket/Damper Options...5 Installation & Mounting Instructions Installation Instructions...6 Modular Floor Boot Installation...12 Cleaning Instructions...13

GENERAL OVERVIEW Introduction In this manual, you will find technical descriptions and diagrams of underfloor system components along with their installation instructions. Practical guidelines and recommendations are also provided. If more information is required about this equipment, please contact an Price sales representative. General Safety Guidelines This document is intended for use by owner-authorized operating/service personnel who are expected to possess the required training to enable them to perform their tasks properly and safely. This individual must have read and understood this document and any referenced materials prior to performing any task on this equipment. Also, it is essential that this individual be familiar with and comply with all applicable governmental standards and regulations pertaining to the task in question. This individual must also verify that installation and connections comply with local building codes. It is the obligation and responsibility of the operating/ service personnel to identify and recognize these inherent hazards, protect themselves, and proceed safely in completing their tasks. Failure to comply with any of these requirements could result in severe personal injury or death to themselves and people at the site, as well as serious damage to the equipment and the property in which it is situated. The equipment discussed in this manual is relatively complicated apparatus and must be handled with the necessary precautions. Individuals may be exposed to certain components or conditions such as refrigerants, oils, materials under pressure, rotating components, and both high and low voltage during installation, operation, maintenance or service of this equipment. If misued or mishandled, each item has the potential to cause bodily injury or death. Safety Symbols The following symbols are used in this document to alert the reader to areas of potential hazard: WARNING Failure to observe may result in personal injury, death or equipment damage. CAUTION Failure to observe may result in equipment damage. NOTE: Used to highlight additional information helpful to the reader. priceindustries.com Modular Floor Diffusers - Manual 1

SYSTEM OVERVIEW Interior Zones CONSTANT AIR VOLUME - COOLING ONLY CONSTANT AIR VOLUME - COOLING ONLY Typically, interior zones have relatively stable loads hence constant volume supply is often employed. A typical interior zone consists of contant volume or constant pressure turbulent floor twist outlets installed in a large, common plenum space. In this method the entire plenum space is treated as one zone and, under fluctuating loads, the amount of air delivered to the space is regulated by the relative pressure in this plenum, modulated by a single point of control. Manual face-adjustable diffusers provide occupant control of airflow volume. VARIABLE AIR VOLUME - COOLING ONLY In the case an open plenum is desired to be divided into several zones, variable air volume control is possible with the use of devices installed under the diffuser or with the use of a variable volume basket. The variable volume baskets are controlled by the UMC3. The UMC3 would open and close the diffusers releasing air from the pressurized plenum. The variable volume (VAV) diffusers require a 24 VAC signal which is provided by the UMC3 to modulate the actuators. Meanwhile, the UMC3 accepts a 0 to 10 VDC cooling signal either from a manual control signal or from a thermostat. The UMC3 modulates the airflow from 0% to 100%. VARIABLE AIR VOLUME - COOLING ONLY 2 Modular Floor Diffusers - Manual priceindustries.com

PRODUCT OVERVIEW Modular Floor Diffusers The Modular Floor Diffuser Twist Pattern (MFD-TP) is designed with a twist effect using radial slots in combination with an inclined discharge. This generates a vertical supply with very high induction due to the turbulent flow. This symmetrical discharge is ideal for mixing within the occupied zone. The Modular Floor Diffuser Displacement Pattern (MFD-DP) is used where low, floor level flow is required. The diffuser slots discharge the air horizontally across the floor where it can absorb the heat load and rise to the return grilles in the ceiling. Polymer 8 in. diffusers are available in black and dusty grey finishes. Aluminum diffusers are available in 8 and 10 in. Network File Location: T:\Underfloor\ROUNDFLOOR\ER160283 - ROUNDFLOOR PRODUCT LINE CHANGES\OPERATION AND MAINTENANCE MANUAL\MODELS TO RENDER\Update for Manual\Page 5 of 16 Replacement drawings.dft Issued date MOUNTING RING MFD-TP MOUNTING RING Blank qty MFD-DP Part qty Factory order no ALUMINUM DESIGN ALUMINUM DESIGN ALUMINUM DESIGN ALUMINUM DESIGN Print Date: 10/28/2016 - Page 5 of 16 Replacement drawings.dft Completion date DIFFUSER DIFFUSER Sch date AIRFLOW POSITION INDICATOR ON FACE AIRFLOW POSITION INDICATOR ON FACE MOUNTING RING MOUNTING RING AIRFLOW POSITION INDICATOR ON FACE AIRFLOW POSITION INDICATOR ON FACE Comment/Tag POLYMER DESIGN POLYMER DESIGN POLYMER DESIGN POLYMER DESIGN DIFFUSER DIFFUSER priceindustries.com Modular Floor Diffusers - Manual 3

PRODUCT OVERVIEW Diffuser Face Options A. Plastic diffusers and can be mounted in either RPF or ZC configurations. B. Aluminum diffusers and can be mounted in either RPF or ZC configurations. ZC available with ZC adapter. Mounting Ring Options A. Ring Press Fit (RPF) mounting ring uses a soft rubberized seal to hold the mounting ring in the bore. RPF comes standard with all modular floor mounting rings. B. Zip Clip (ZC) mounting ring uses the RPF seal to center the ring in the bore and three (3) clips which ratchet in place to secure the mounting ring to the floor. If the floor tile has a contoured bottom, care must be taken to ensure all three zip clips can tighten against the tile. C. Stepped Bore does not require a mounting ring; the floor is cut to size to fit only the diffuser face. MODULAR FLOOR DIFFUSERS TWIST PATTERN MOUNTING RING POLYMER ALUMINUM ADAPTERS DISPLACEMENT PATTERN ALUMINUM STEPPED BORE ZIP CLIP 4 Modular Floor Diffusers - Manual priceindustries.com

PRODUCT OVERVIEW Basket/Damper Options BASKETS/DAMPERS AVAILABLE IN 8 IN. AND 10 IN. SIZES BASKETS/DAMPERS AVAILABLE IN 8 IN. SIZE B PLASTIC 5 IN. BASKET WITH NO DAMPER. DB PLASTIC 5 IN. BASKET WITH DAMPER. BS PLASTIC 2 IN. BASKET WITH NO DAMPER. MDBA METAL 5 IN. BASKET WITH FACE ADJUSTABLE DAMPER. DBA PLASTIC 5 IN. BASKET WITH FACE ADJUSTABLE DAMPER. DBV PLASTIC 6.5 IN. BASKET WITH VARIABLE VOLUME DAMPER CONTROLLED WITH PRICE PCM (UMC3 OR UMCB). DBS PLASTIC 2 IN. BASKET WITH DAMPER. MDB METAL 5 IN. BASKET WITH DAMPER. DBAS PLASTIC 2 IN. BASKET WITH FACE ADJUSTABLE DAMPER. MB METAL 5 IN. BASKET WITH NO DAMPER. RBC BASKET WITH COLLAR FOR DUCT CONNECTION. BOP BLANK OFF PLATE RPN RELATIVE PRESSURE NODE (AVAILABLE WITH PCU) priceindustries.com Modular Floor Diffusers - Manual 5

INSTALLATION & MOUNTING INSTRUCTIONS Installation Instructions The components for the modular floor diffuser assembly are shipped assembled. The following is a recommended installation guide. STEP 1: Cut the hole in the floor/tile according to the following table: FIGURE 1: RPF RINGS Hole Sizes Size MFD Ring Press Fit / Zip Clip 8 in. 8.50 ± 0.040 (216 ± 1) 10 in.* 10.50 ± 0.040 (267 ± 1) *10 in. available in aluminum only STEP 2: Secure the mounting ring into the floor cutout: A. RPF rings do not require additional hardware; the rubberized seal prevents the unit from accidentally being dislodged during normal foot traffic as shown in Figure 1. Do not use glue! B. Zip Clip mounting uses three (3) clips that lock the ring in place. The clips can be inserted onto the legs of the mounting ring from the roomside opening and locked into place, as shown in Figure 2. NOTE: For aluminum mounting rings the zip clip adapter must first be snapped into place before placing the zip clips, as shown in Figure 3. FIGURE 2: ZIP CLIP MOUNTING Floor Tile Zip Clip FIGURE 3: ZIP CLIP ADAPTER FOR ALUMINUM MOUNTING RINGS PHILLIPS HEAD 6 Modular Floor Diffusers - Manual priceindustries.com

INSTALLATION & MOUNTING INSTRUCTIONS If using a DBV basket skip step 3 and go straight to step 4, otherwise proceed to step 3 below. STEP 3: The basket and damper assembly can now be placed into the mounting ring: A. The basket should be aligned such that the tabs on the basket flange aligns with the notch in the mounting ring. The tabs are 171 and should only be installed in one orientation, refer to Figure 4. B. The damper must be installed such that the thinner web portion on the damper legs aligns with the raised tab on the basket, refer to Figure 5. C. Using the minimum airflow knob, rotate until the indicator points to the desired min airflow as shown in Figure 6. Press down on the damper to ensure it does not slip above the min airflow knobs. D. For DBA installation, the damper can be placed into basket and rotated until it drops into place, in the correct orientation, refer to Figure 6 and Figure 7. NOTE: The airflow arrow will point to the open - closed text or the curved triangular air flow bar on the mounting rings. FIGURE 4: BASKET TAB ALIGNMENT FIGURE 5: DAMPER LEG ALIGNMENT FIGURE 6: MINIMUM AIRFLOW KNOB FIGURE 7: DBA BASKET priceindustries.com Modular Floor Diffusers - Manual 7

INSTALLATION & MOUNTING INSTRUCTIONS STEP 3 CONTINUED: E. RPN and RBC are installed into the mounting ring, following the same procedure as other baskets. Two protrusions prevent the diffuser from rotating. Figure 8 shows the RBC. F. 1/4 in. pressure hose is connected to the top or bottom fitting on RPN to measure the pressurized underfloor plenum or occupied zone, respectively. Figure 9 shows the the Blank Off Plate and Figure 10 shows the installed RPN. FIGURE 8: RBC FIGURE 9: BLANK OFF PLATE FIGURE 10: RPN 8 Modular Floor Diffusers - Manual priceindustries.com

SERVICE & INSTALLATION MANUAL Modular Floor Diffusers INSTALLATION & MOUNTING INSTRUCTIONS STEP 4: Variable Volume Diffuser Basket (DBV) Installation The Variable Volume Diffuser Basket (DBV) is designed to allow even distribution of supply air through the modular floor diffuser core while integrating into a VAV cooling system. It utilizes a 24 VAC floating point actuator to modulate a gasketed control damper based on a signal from the building control system or from the Price PCM - Power and Control Module. The actuator modulates the damper to throttle the supply air from the pressurized underfloor plenum to the occupied zone. The motorized damper provides control of cooling flows from maximum to near shut-off. The DBVs can be daisy chained from one unit to another using the provided plenum rated cable with plug-in modular connectors. INSTALLATION INSTRUCTIONS 1. Locate the mounting ring in the hole in the floor tile. 2. Connect the control wire to the DBV through the floor, Figure 11. 3. Insert the DBV, ensuring that the tabs on the DBV align with the holes in the mounting ring, Figure 12. Variable Volume Diffuser Basket (DBV) Prod The Variable Volume Diffuser Basket (DBV) is designed to allow even distribution of supply air through the round floor diffuser core while integrating into a VAV cooling system. It utilizes a 24 VAC floating point actuator to modulate a gasketed control damper based on a signal from the building control system or from the Price UMC Underfloor Modulating Controller. The actuator modulates the damper to throttle the supply air from the pressurized underfloor plenum to the occupied zone. The motorized damper provides control of cooling flows from maximum to near shut-off. The DBVs can be daisy chained from one unit to another using the provided plenum rated cable with plug-in modular connectors. Supply and install Price DBV, black Distributor Basket with integral VAV Damper. The DBV shall be supplied with a floating point actuator furnished with two modular jacks (RJ12) for system connections and one 25 foot plenum rated modular plug-in control cable. The electric actuator shall be 24 VAC bidirectional, directly coupled to the damper screw. The damper shall move from a full open position to a fully closed position in 90 seconds. The actuator must be capable of operating in the stalled position without overheating or mechanical damage. Peripheral gasket shall be provided on the control damper and shall allow zero leakage at 0.05 wc when fully closed. DBV Variable Volume Diffuser Basket (DBV) - Insta FIGURE 11: CONNECT CONTROL WIRE TO DBV Steps 1 and 2 DBV with the hol 1. Locate the 2. Connect the 3. Insert the D 4. Place diffus FIGURE 12: INSERT DBV Steps 1 and 2 www.price-hvac.com priceindustries.com Modular Floor Diffusers - Manual 9

INSTALLATION & MOUNTING INSTRUCTIONS STEP 5: The diffuser face can now be installed into the mounting ring: A. If the assembly is not face adjustable (DB, DBS, MDB), then the face can be dropped in place and the unit is complete, refer to Figures 13A and 13B. B. If the assembly is face adjustable, the tabs on the damper must align and lock into the bottom of the diffuser face, Figure 14A and Figure 14B. The arrow on the diffuser face should also point in-between the open and close labels on the mounting ring as shown in Figures 13A and 13B. FIGURE 13A: ALUMINUM DIFFUSER FACE INSTALLATION TOP VIEW FIGURE 13B: POLYMER DIFFUSER FACE INSTALLATION TOP VIEW FIGURE 14A: ALUMINUM DIFFUSER FACE INSTALLATION BOTTOM VIEW FIGURE 14B: POLYMER DIFFUSER FACE INSTALLATION BOTTOM VIEW 10 Modular Floor Diffusers - Manual priceindustries.com

INSTALLATION & MOUNTING INSTRUCTIONS STEP 6: Final Inspection: The diffuser should sit flush in the mounting ring and if face adjustable, should allow rotation of the damper quite easily between open and close positions. When a downward force is applied to the face, the diffuser locks in place. This is to reduce the chance of inadvertent rotation when walking across the diffuser. Therefore, excessive downward force on the face will prevent rotation of the diffuser. DIFFUSER FLUSH WITH MOUNTING RING priceindustries.com Modular Floor Diffusers - Manual 11

INSTALLATION & MOUNTING INSTRUCTIONS Modular Floor Boot Installation The Price modular floor boots are specially designed for mounting on the bottom of a floor tile under a modular floor diffuser. A top plate with a discharge hole outlet ensures proper sealing to the diffuser even when structural depressions exist on the bottom surface of the floor tiles. The MFB-F enables a ducted connection to a fan powered terminal unit. It is designed to control the supply of conditioned air to a space which has a variable occupancy schedule. The MFB-HC is used in conjunction with heat/cool applications. The MFB-HC comes with two (2) inlets, one (1) for connecting to a fan powered terminal unit and the second to admit supply air from the pressurized plenum. The MFB-HC comes complete with a 24 VAC floating point actuator on the inlet open to the plenum to cycle a gasketed control damper through a 90 range of movement. The controller modulates based on a call for cooling either directly from the building control system, from the Price PCM (UMC3 or UMCB). A 25 foot plenum rated control cable is provided with each unit for connecting to a controller or daisy chaining to multiple boots. Supply air is either provided through an open connection to the pressurized plenum or via a ducted fan powered terminal unit. BOOT SIZE SIDE LENGTH (A) PLENUM BOOT SIZE TILE CENTER (D) SIDE LENGTH (E) SIDE LENGTH (F) 8B 10.00 (254) 6.50 (165) 8.7 (221) 8.0 (203) 10B 12.00 (305) 7.50 (191) 4.5 (116) 3.8 (97) INSTALLATION INSTRUCTIONS 1. Cut hole in tile (hole must be located as marked on submittal and installation page). 2. Fasten the flange on the floor tile by screwing through the outer hole labeled 2. The gasket will cover the holes. Ensure that self-drilling screws are used. 3. Place MFB over flange in with small holes aligned, the large holes provide clearance for the fastener used in Step 2. 4. Fasten MFB to mounting flange and floor tile by screwing through holes labeled 4. NOTE: Adjust set screw and damper to minimum airflow for balancing. MFB INSTALLATION D F D 4 2 E 2 Gasket Strip 4 Floor Panel Mounting Flange MFB Type PLENUM INLET (VC, HC) & FAN INLET (F, FC) NOM. DUCT SIZE FAN INLET (B) PLENUM INLET ('C) 6 (152) 5.88 (149) 8 (203) 7.88 (200) 4 MFB-F FOR MFB-F: 1.00 (25) 9.50 (241) 9.50 (241) B FAN AIRFLOW A A A 1.00 (25) FOR MFB-HC: 1.00 (25) 9.50 (241) FAN AIRFLOW PLENUM AIRFLOW 9.50 (241) C B HEAT COOL A A A 7.00 (178) 12 Modular Floor Diffusers - Manual priceindustries.com

INSTALLATION & MOUNTING INSTRUCTIONS Cleaning Instructions The face can be cleaned from liquids or food by wiping the face with a moist rag. For more stubborn stains use disinfectant wipes. The diffuser basket should be periodically cleaned by removing the diffuser face from the ring and vacuuming any particles that have accumulated in the catch basket. The diffuser face can be removed by inserting the diffuser face removal tool, into the notches carved out along the diffuser face. Once the tool is inserted simply bend back the clip holding the diffuser face in place and pull out the diffuser. DIFFUSER FACE CLEANING INSERT DIFFUSER FACE REMOVER TOOL DIFFUSER FACE REMOVER TOOL Name Description Mounting Options Basket Options Standard Finish MFD-TP - Polymer MFD-DP - Polymer Twist diffuser High induction mixing Polymer construction 8 in. only Displacment diffuser Non-mixing low throw Polymer construction 8 in. only Standard with Ring Press Fit (RPF) Zip-Clip No Fastening 8 in. or 10 in.: B, DB, DBA, DBV, 8 in. only: BS, DBS, DBAS, MB, MDB, MDBA Black Dusty Grey (DG) Black Dusty Grey (DG) MFD-TP - Aluminum Twist diffuser High induction mixing Aluminum construction 8 in. or 10 in. Fine Aluminum Finish MFD-DP - Aluminum Displacement diffuser Non-mixing low throw Aluminum construction 8 in. or 10 in. Fine Aluminum Finish priceindustries.com Modular Floor Diffusers - Manual 13

This document contains the most current product information as of this printing. For the most up-to-date product information, please go to priceindustries.com 2018 Price Industries Limited. All rights reserved.