Installation Instructions. devireg 330

Similar documents
MAKING MODERN LIVING POSSIBLE INT. Danfoss Link HR Hidden Relay. Installation Manual. Danfoss Heating

Installation Guide. DEVIreg 527. Electronic Time Regulator.

The advantages of the pipe tracing systems are: Sensor. Insulation Heating cable Aluminium tape. Fig. 1 Fig. 2

Instruction Manual MINI IRRIGATION CONTROLLER.

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Introduction. Series A99 Temperature Sensors. Features and Benefits

Series A99 Temperature Sensors. Features and Benefits. The A99 temperature sensor line includes various models, such as:

Digital Room Thermostats with Touch Screen LCD

The original heating cable just got better

HERZ Electronic room thermostat analog and digital

M Technical Specification No. for the supply of Battery Charger. Israel Railways Ltd. Rolling Stock Division

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

FREQUENCY INVERTER INSTALLATION & USER GUIDE

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

Owners Manual: - Pumps

Wilo-Control SC-Fire Jockey

IRRIGATION CONTROLLER

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Defender 3000 Series Base Instruction Manual

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

230VAC Power Inverter 400W Owner s Manual

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

TITLE: SPECIFICATION FOR BENCH VICE & BENCH GRINDER TABLE OF CONTENTS. 0.1 Circulation List. 0.2 Amendment Record

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

G72x Series Direct Spark Ignition Controls

Duplex Booster System Instruction Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Installation Manual WAV Version WAV HBX Control Systems Inc. Page 1

Instrucciones de instalación y funcionamiento Installation and operating instructions

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

AKM 345 Gen2. Instruction Manual. Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35. Document ID: IST EN

DC Master 24/ A

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

Power Inverter 400 MW Owner s Manual

Ex m Solenoid Operator Type 0519

AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS

ELEKTROMATEN ST Sliding-door-drive

SSA955. Synco living Radiator Control Actuator

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Usage Instructions of Solar Control for 3Way-Ball Valve

Tina 4A Connection block

Contents. Mounting instructions. 3 Hangers placement...4 Mains connection instructions..5 Safety zones.. 6 Maintenance...7 Warranty card.

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Installation Instructions

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

REVISED ATM72 Auto Transfer Module

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

Installation Instructions

Read and understand this manual for safely usage.

ZB0050 / ZB0051 ZB0070 / ZB0071

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Installation & Operation Manual Chef Base

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

TPAK Series COOLANT PUMP

SDM72 Start on Demand Modules

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Rental Power QSB7 series engine

CX-SERIES ADVANCED BATTERY CHARGER

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

#14. Evaluation of Regulation 1071/2009 and 1072/ General survey COMPLETE 1 / 6. PAGE 1: Background

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

Smile 11 RA/-B Smile 12 RF/-G Reset button

KEWTECH. KT56 digital multi function tester. Instruction manual

DeltaSol AX * *

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

DIGITAL TEMPERATURE CONTROL

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

Operating Instructions

CONTROL AND PROTECTION PANEL FOR TRACTOR-PUMP CTR-087/0N THE TRACTOR/PUMP IS STOPPED WHEN THERE ARE ANOMALIES (VIA ELECTROMAGNET) CONCERNING:

Traffic Logix SafePace 400 Radar Sign. Installation Manual

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Installation Instructions

Video & Power Over Coax Kit

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Emotron DCM Control Unit

Analytical Diaphragm Pump Series MP MP06, MP12

RVD110 RVD G2381en. Installation. Commissioning

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

Operating Instructions Electronic transformers for lowvoltage halogen lamps

Tank Monitor. Instruction manual DTM01. Tank Monitor

Recommendations Multipin connector Wired mode (permanent and pulse signal) Positioning mode

AXIAL FANS Axis / Tubo OPERATION MANUAL

Installation Manual LIGHTWAY PV MODULES. Revision Date March 30, 2013 /Applicable for IEC certified products

MAGNETIC EFFECT OF ELECTRIC CURRENT

Transcription:

GB-DAS Installation Instructions devireg 330 1

Application: devireg 330 for control of room temperature, refrigerating systems, floor temperature, frost protection, snow melting, industrial purposes and roof gutter installations. Installation: devireg 330 is an electronic thermostat which can lower the temperature at night, and is designed for attachment in control cabinets with an overall height of minimum 52 mm, as well as for external DIN rail attachment. 1. The installation must be permanent. devireg 330 must be placed after an external switch. 2. The temperature is lowered by 5ºC when clamps 3 and 6 are short-circuited by means of an external switch (see circuit diagram). 3. The thermostat must be attached to a vibration-free surface. 4. A room sensing unit is to be placed on an inner wall, about 1.5 m above the floor, and not in the immediate vicinity of radiators, doors or windows, thus the sensor is not exposed to draught or direct sunlight. 5. The connection between thermostat and sensor is to be made with 1.5 mm² installation cable. The cable connection can be up to 50 m without affecting the accuracy of the thermostat. The cable must not, however, be placed parallel to high-voltage cables as this can induce undesirable signals. 6. If the sensor is to be cast in or will be exposed to pressure, the sensor should be placed in an installation pipe. 7. Large contactors or other objects producing strong electromagnetic fields must not be placed in the immediate vicinity of the electronic part. 8. Wire connection according to circuit diagram. 2

52 mm 36 mm 45 mm 61 mm 86 mm Fig. 1 3

Cooling: 16 N 0-3600 W L Heating: 0-3600 W 4

Control of functioning: Trouble-shooting If heat is not turned on by activating the thermostat, check the RCD and fuses before contacting an authorized electrician. Trouble-shooting chart: Reserved for the electrician! Control of functioning: Control mains voltage on clamps 3 and 4. Tighten up load clamps 1 and 4. Measure the resistance in the heating cable and calculate the output: P = U 2 = 52900 W (at 230 V~ R R From the calculated output the heating cable type can be termined by looking it up in your Devi catalogue. If the sensor wire clamps 7 and 8 are removed, the red indicator lamp should light up and the thermostat should switch on. If not the thermostat is defect. Measuring of sensor with ohmmeter should give a stable resistance compared to the ambient temperature - see technical data chart. If the sensor access - clamps 7 and 8 - is short-circuited, the green indicator lamp should light up and the thermostat should be switched off. If not, the thermostat is defect. 5

Temperature range: Voltage: Technical data -10 C +10 C +5 C +45 C +15 C +30 C +30 C +90 C +60 C +160 C 180-250 V ~ 50/60 Hz Inductive load Resistive load Cos φ = 0.3 max. 4 A 16A / 3600W Hysteresis: -10 C +10 C +5 C +45 C +15 C +30 C +30 C +90 C +60 C +160 C ±0.2 C ±0.2 C ±0.2 C ±0.4 C ±0.75 C Night set back: 5 C Operating temperature: -10 C +50 C IP Class IP 20 Sensing unit: -10 C - +10 C +5 C - +45 C +15 C - +30 C +30 C - +90 C +60 C - +160 C NTC 15 kohm / 25 C NTC 15 kohm / 25 C NTC 15 kohm / 25 C NTC 100 kohm / 25 C NTC 16.7 kohm / 100 C LED Indicator: No light Red Green The system is off. Heat is on but the preset temperature is not reached yet. The preset temperature is reached and heat is off. 6

The Devi Warranty: You have purchased a deviheat system, which we are certain will increase your home comfort and economy. deviheat provides complete heating solutions with deviflex heating cables or devimat heating mats, devireg thermostats and devifast fitting bands. If, however, contrary to all expectations, a problem should occur with your heating system, we at Devi, with manufacturing units in Denmark, are, as European Union suppliers, subject to general product liability rules, as stated in Directive 85/374/ CEE, and all relevant national laws which implies that: Devi provides a warranty for deviflex heating cables and devimat heating mats for a 10 year period and all other Devi products for a 2 year period against defects in material and production. The guarantee is granted on the conditions that the WAR- RANTY CERTIFICATE on the overleaf is filled out properly in accordance to instructions and that the defect is inspected by, or presented to, Devi or authorised Devi distributor. Please note, that the wording of the WARRANTY CER- TIFICATE must be provided in english or local language with the ISO code for your country in the upper left corner of the front page of the installation instruction in order to release the warranty. The obligation of Devi will be to repair or supply a new unit, free of charge to the customer, whitout secondary charges linked to repairing the unit. In case of defective devireg thermostats, Devi reserves the right to repair the unit free of charge and without unreasonable delay to the customer. The Devi warranty only covers connections made by authorised electricians and installations performed in accordance with the installation instruction, and does not cover faults caused by incorrect designs supplied by others, misuse, damage caused by others, or incorrect installation or any subsequent damage, that may occur. If Devi is required to inspect or repair any defects caused by any of the above, then all work will be fully chargeable. The Devi warranty is void, if payment of the equipment is in default. At all times, we at Devi will respond honestly, efficiently and promtly to all queries and resonable requests from our customers. The above mentioned warranty concerns product liability whereas matters in relation to legislation on sale of goods shall be referred to national law. 7

Warranty Certificate The Devi Warranty is granted to: Name: Address: Postal code: Phone: Please Observe! In order to obtain the Devi Warranty, the following must be carefully filled in. See other conditions on the overleaf. Electrical Installation by: Installation date: Type of thermostat: Production code: Suppliers Stamp: DEVI A/S DK 7100 Vejle Tlf. +45 76 42 47 00 Fax +45 76 42 47 03 VICKG102 11/2009 Art.no. 08095476-01 8