Section. IEC Contactors Selection Guide...D-3. Non-Reversing Contactors YS1N AC Controlled...D-5 YS3N DC Controlled...

Similar documents
YS Series Contactors YS1N- F11 ****

IEC Contactors. IEC Contactors. YS Series. YS Series Contactors YS1N- F11 ****

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF40... AF96 3-pole contactors Technical data

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Short form catalogue. Motor protection & control

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Star Series Motor protection & control

AF series contactors (9 2650)

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

CI-TI Contactors and motor starters Types CI 61 - CI 98

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

AF series contactors (9 2650)

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Ktec Contactors and thermal overloads

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Essential equipment for all your requirements

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

ASL09..S 3-pole Contactors - Spring Terminals

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Industrial Contactors CTX 3 3P 185A - 800A

Manual Motor Starters. Meta-MEC

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Oiltight Switches & Pilot Devices

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Technical Information

22AF 40AF AF 150AF 225AF 400AF 800AF

Description. Positive safety relays

Micro Contactor MA Series

AE 9... AE 40 Contactors NE... Contactor Relays

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

3 - Protection components Motor circuit-breakers

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

4 - Miniature controls

Contactor Types CI 61-98

Softstarter Intelligent Controllers

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

RU Series Universal Relays

Meta Solution. Contactors and Overload relays

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Application Description

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Switches Unlimited Phone: * Fax:

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

ABB s new control and protection devices

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

CI-TI Contactors and Motor Starters Type CI 6-50

TAE pole Contactors

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

HEAVY DUTY POWER RELAYS FEATURES

Technical Information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

NEMA Contactors & Starters (Freedom)

Mini Contactors CI 4-

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

MAGNETIC CONTACTOR & MOTOR STARTER

FUJI Magnetic Contactors and Motor Starters

LR9 F OVERLOAD RELAYS

MAGNETIC CONTACTOR & MOTOR STARTER

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Relays. Industrial Automation Catalog Section - U906. Selection Guides. Solid State Relays RSS Series

Series CA5 Contactors

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

JOSLYN CLARK VACUUM CONTACTOR FEATURES

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Controls. CONTACTORS CWB Line (up to 40A)

General + Definite Purpose Contactors

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

About us. Switchgear Factory, Mumbai

Quick selection table

Motor Starting Solutions Open Type Version, in Kit Form

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

Modular contactors and relays

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Page 2-4 Page 2-8. Page Page 2-13

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Application Mini Contactors for Motors and Resistive Loads

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Meta Solution. Contactors and Overload relays

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

3. Coils shall be of molded construction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Selection Guide Motor Control Device Solutions

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Transcription:

Section Selection Guide...-3 Non-Reversing Contactors YS1N AC Controlled...........-5 YS3N C Controlled...........-6 Reversing Contactors YS1R AC Controlled...........-7 YS3R C Controlled...........-8 Thermal Overload Relay YS1T-RHA...................-9 Starters...-11 Accessories...-1 Specifications Contactors and Starters........-16 Overload Relays..............-4 Accessories..................-8 imensions...-35 Mounting iagrams...-43 Wiring iagrams...-47 Application Tables...-51 for more information on this product family visit www.idec.com/contactor Additional Web Resources New and updated product information ownloadable software demos & upgrades Part configuration tool & cross reference Online stock check & ordering IEC field sales & distributor search Online literature request ownloadable manuals & CA drawings Manufacturer s suggested retail price list Product training schedule & locations Advertising & trade show schedules Press releases & FAQs www.idec.com/contactor

Selection Guide IEC YS Series Contactors / Starters YS Series: Superior performance and low maintenance Key features include: Simple, compact, rugged electromechanical devices Meets IEC, UL, c-ul and other international standards All Contactors, Thermal Overload Relays, and Auxiliary Contact Blocks bear the CE mark 35mm or 75mm IN Rail or direct panel mounting Bifurcated double bridge auxiliary contacts, the moving contact bridge has an H form; suitable for interface with electronic circuit Advanced design and materials, special silver-alloy long life contacts Cadmium-free contacts for environmental safety Bimetallic thermal overload relays Easy operation and maintenance; irect and simple motor control ual frequency 50/60 Hz coils IEC YS Series Contactors are used in switching motor loads. Like all IEC products, each model is engineered for long life, minimum maintenance, dependable operation, and superior performance. Snap on accessories are available for the IEC YS series, giving each model the flexibility to meet any application requirement. 1. Auxiliary contact blocks Top mounting type ( or 4 poles type) Side mounting type ( poles type). Adjustable thermal overloads 3. Surge suppressor modules 4. Mechanical interlock blocks 5. PLC interface modules - www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Selection Guide Selection Guide RELAY INTERFACE MOULE SURGE SUPPRESSOR MOULES YS9Z-TU5 for YS1N-9F to -5F YS9Z-TU65 for YS1N-3F to -65F YS9Z-TU15 for YS1N-80F to -15F YS9Z-TU180 for YS1N-150F to -180F YS9Z-TU300 for YS1N-0F to -300F CONTACTORS Non-reversing YS1N, AC Controlled YS3N, C Controlled (With Surge Suppressor Module) YS9Z-TCU500UH The interface module incorporates contacts which are actuated upon energization of the module from low power 4VC sources such as outputs from sensors and programmable controllers. SECON CONTACTOR For reversing applications YS1R, AC Controlled YS3R, C Controlled (reversing type) MECHANICAL INTERLOCK BLOCKS Used for reversing contactors YS9Z-TMI65 for YS1N-9F through 65F YS9Z-TMI15 for YS1N-80F through 300F AUX. CONTACT BLOCK (P, side mounting type) YS1A-TAS11F for YS1N-9F to -65F AUX. CONTACT BLOCKS (4P, top mounting type) YS1A-TAH440F (4) YS1A-TAH431F (3-1) YS1A-TAH4F (-) YS1A-TAH413F (1-3) YS1A-TAH404F (4) for YS1N-9F to -65F AUX. CONTACT BLOCKS (P, top mounting type) YS1A-TAH0F () YS1A-TAH11F (1-1) YS1A-TAH0F () for YS1N-9F to -65F www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -3

YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable auxiliary contacts use bifurcated double bridge contact form irect panel mount with screws or 35mm IN rail (9F to 65F) Conforms to IEC standards: EN60947-1, EN60947-4-1, EN-60947-5-1 Approval standards: UL508 (UL File No. E67770, E184169) CE Certified Ordering Information IEC CONTACTORS Specify the maximum AC3 current code for the contactor in place of. Specify the coil voltage code for the contactor in place of ****. This part number is not indicated on the label of the contactor. YS1N- F11 **** Completed Part Number of Contactors 1 Product Series YS1N: Non- reversing contactor, AC controlled YS1R: Reversing contactor, AC controlled YS3N: Non-reversing contactor, C controlled YS3R: Reversing contactor, C controlled a) Approximate Maximum AC3 Current AC or C Controlled Contactors 9:9A, 1:1A, 0:0A, 5:5A, 3:3A, 38:38A, 40:40A, 50:50A, 65:65A, 80:80A, 100:100A, 15:15A AC Contactors Only 150:150A, 180:180A, 0:0A, 300:300A b) Type of Contactor 4 Coil Voltage (Rated Voltage and Frequency) A04 : AC4V 50/60Hz A048 : AC48V 50/60Hz A110 : AC110V 50/60Hz A10 : AC10V 50/60Hz A30 : AC30V 50/60Hz A40 : AC40V 50/60Hz A380 : AC380V 50/60Hz A415 : AC415V 50/60Hz A480 : AC480V 50/60Hz A600 : AC600V 50/60Hz 04 : C 4V 048 : C 48V 110 : C 110V 0 : C 0V M100 : C 110V M00 : C 0V (Other Voltages Available, Contact IEC) AC Contactors (all sizes) C Contactors (sizes 9-65) C Contactors (sizes 80-15) F: AC controlled all sizes FG: C Controlled, sizes 9-65 FG: C Controlled, sizes 80-15 3 Auxiliary Contact Configuration (Built onto conctactor) 01: with 1, only for contactors sizes 9F-1F 10: with 1, only for contactors sizes 9F-1F 11: with 1-1, only for contactors sizes 0F-65F : with -, only for contactors sizes 80F-300F Notes: 1. Use the above ordering information only when interpreting part numbers. o not use for developing part numbers.. Please see tables on following pages for proper selection. 3. For specifications please see page -16 through page -34. -4 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

YS Series YS1N Non-Reversing AC Contactors, AC Controlled AC1 I e (Amps) AC3 kw AC3 Rating EN 60974-4-1 HP Rating per UL508 Auxiliary 3 Phase 1 Phase 3 Phase Contacts 0-30V 380-400V 500V 660-690V 10V 30V 00-08V 0-40V 440-480V 0 8.5. 4 5.5 5.5 1/3 1 5 5 550-600V N.O. N.C. Part Number 0 1 YS1N-9F01**** 1 0 YS1N-9F10**** 0 11.5 3 5.5 7.5 7.5 3/4 3 3 7.5 5 0 1 YS1N-1F01**** 1 0 YS1N-1F10**** 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 1 1 YS1N-0F11**** 30 5.5 11 15 15 3 7.5 7.5 15 15 1 1 YS1N-5F11**** 50 30 7.5 15 18.5 18.5 5 7.5 10 0 0 1 1 YS1N-3F11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS1N-38F11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS1N-40F11**** 80 44 15 30 33 3 7.5 10 15 40 40 1 1 YS1N-50F11**** 80 60 18.5 30 37 37 5 10 0 0 50 40 1 1 YS1N-65F11**** 135 85 45 55 45 7.5 15 5 5 60 60 YS1N-80F**** 150 105 30 55 65 65 - - 30 35 60 75 YS1N-100F**** 150 114 37 60 75 75 - - 40 50 100 100 YS1N-15F**** 00 138 45 75 90 100 - - 40 50 100 15 YS1N-150F**** 40 179 55 95 110 110 - - 50 60 15 15 YS1N-180F**** 60 05 65 110 13 13 - - 60 75 150 150 YS1N-0F**** 350 300 90 160 160 00 - - 75 100 00 00 YS1N-300F**** Codes for Control Circuit AC Voltages 50/60 Hz Volts AC 50/60 Hz 4 48 10 0 40 380 415 480 Code to replace **** A04 A048 A10 A0 A40 A380 A415 A480 Consult an IEC representative for other coil voltages. For accessories, see page -1. For specifications, see page -16 through -34. For dimensions, see pages -35. For other application tables, see page -51. www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -5

YS Series YS3N Non-Reversing C Contactors, C Controlled AC1 I e (Amps) AC3 KW AC3 Rating EN 60974-4-1 HP Rating per UL508 Auxiliary 3 Phase 1 Phase 3 Phase Contacts 0-30V 380-400V 500V 660-690V 10V 30V 00-08V 0-40V 440-480V 0 8.5. 4 5.5 5.5 1/3 1 5 5 550-600V N.O. N.C. Part Number 0 1 YS3N-9FG01**** 1 0 YS3N-9FG10**** 0 11.5 3 5.5 7.5 7.5 3/4 3 3 7.5 5 0 1 YS3N-1FG01**** 1 0 YS3N-1FG10**** 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 1 1 YS3N-0FG11**** 30 5.5 11 15 15 3 7.5 7.5 15 15 1 1 YS3N-5FG11**** 50 30 7.5 15 18.5 18.5 5 7.5 10 0 0 1 1 YS3N-3FG11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS3N-38FG11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS3N-40FG11**** 80 44 15 30 33 3 7.5 10 15 40 40 1 1 YS3N-50FG11**** 80 60 18.5 30 37 37 5 10 0 0 50 40 1 1 YS3N-65FG11**** 135 85 45 55 45 7.5 15 5 5 60 60 YS3N-80FG**** 150 105 30 55 65 65 - - 30 35 60 75 YS3N-100FG**** 150 114 37 60 75 75 - - 40 50 100 100 YS3N-15FG**** Codes for Control Circuit C Voltages, 9F through 65F Codes for 80F/100F/15F Volts C 4 48 110 0 110 0 Code to replace **** 04 048 110 0 M100 M00 Consult an IEC representative for other coil voltages. For accessories, see page -1. For specifications, see pages -16 through -34. For dimensions, see page -35. For other application tables, see page -51. -6 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

YS Series YS1R Reversing AC Contactors, AC Controlled AC1 I e (Amps) AC3 kw AC3 Rating EN 60974-4-1 HP Rating per UL508 Auxiliary 3 Phase 1 Phase 3 Phase Contacts 0-30V 380-400V 500V 660-690V 10V 30V 00-08V 0-40V 440-480V 0 8.5. 4 5.5 5.5 1/3 1 5 5 550-600V N.O. N.C. Part Number 0 1 YS1R-9F01**** 1 0 YS1R-9F10**** 0 11.5 3 5.5 7.5 7.5 3/4 3 3 7.5 5 0 1 YS1R-1F01**** 1 0 YS1R-1F10**** 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 1 1 YS1R-0F11**** 30 5.5 11 15 15 3 7.5 7.5 15 15 1 1 YS1R-5F11**** 50 30 7.5 15 18.5 18.5 5 7.5 10 0 0 1 1 YS1R-3F11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS1R-38F11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS1R-40F11**** 80 44 15 30 33 3 7.5 10 15 40 40 1 1 YS1R-50F11**** 80 60 18.5 30 37 37 5 10 0 0 50 40 1 1 YS1R-65F11**** 135 85 45 55 45 7.5 15 5 5 60 60 YS1R-80F**** 150 105 30 55 65 65 - - 30 35 60 75 YS1R-100F**** 150 114 37 60 75 75 - - 40 50 100 100 YS1R-15F**** 00 138 45 75 90 100 - - 40 50 100 15 YS1R-150F**** 40 179 55 95 110 110 - - 50 60 15 15 YS1R-180F**** 60 05 65 110 13 13 - - 60 75 150 150 YS1R-0F**** 350 300 90 160 160 00 - - 75 100 00 00 YS1R-300F**** Codes for Control Circuit AC Voltages 50/60 Hz Volts AC 50/60 Hz 4 48 10 0 40 380 415 480 Code to replace **** A04 A048 A10 A0 A40 A380 A415 A480 Consult an IEC representative for other coil voltages. For accessories, see page -1. For specifications, see page -16 through -34. For dimensions, see pages -35. For other application tables, see page -51 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -7

YS Series YS3R Reversing C Contactors, C Controlled AC1 I e (Amps) AC3 kw AC3 Rating EN 60974-4-1 HP Rating per UL508 Auxiliary 3 Phase 1 Phase 3 Phase Contacts 0-30V 380-400V 500V 660-690V 10V 30V 00-08V 0-40V 440-480V 0 8.5. 4 5.5 5.5 1/3 1 5 5 550-600V N.O. N.C. Part Number 0 1 YS3R-9FG01**** 1 0 YS3R-9FG10**** 0 11.5 3 5.5 7.5 7.5 3/4 3 3 7.5 5 0 1 YS3R-1FG01**** 1 0 YS3R-1FG10**** 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 1 1 YS3R-0FG11**** 30 5.5 11 15 15 3 7.5 7.5 15 15 1 1 YS3R-5FG11**** 50 30 7.5 15 18.5 18.5 5 7.5 10 0 0 1 1 YS3R-3FG11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS3R-38FG11**** 60 37 11 18.5 30 3 7.5 10 15 30 30 1 1 YS3R-40FG11**** 80 44 15 30 33 3 7.5 10 15 40 40 1 1 YS3R-50FG11**** 80 60 18.5 30 37 37 5 10 0 0 50 40 1 1 YS3R-65FG11**** 135 85 45 55 45 7.5 15 5 5 60 60 YS3R-80FG**** 150 105 30 55 65 65 - - 30 35 60 75 YS3R-100FG**** 150 114 37 60 75 75 - - 40 50 100 100 YS3R-15FG**** Codes for Control Circuit C Voltages, 9F through 65F Codes for 80F/100F/15F Volts C 4 48 110 0 110 0 Code to replace **** 04 048 110 0 M100 M00 Consult an IEC representative for other coil voltages. For accessories, see page -1. For specifications, see page -16 through -34. For dimensions, see pages -35. For other application tables, see page -51-8 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

YS Series Thermal Overload Relays YS1T-RHA thermal overload relays are designed to meet the heating characteristics of induction motors with insulation class type E. Various functions can be selected by using the reset button and adjustment button on top of the thermal overload relay. Key features of the YS1T Series include: Single-phase protection Bi-metallic Compact and sturdy Ambient temperature compensation mechanism Manual/automatic reset operation 3 element type with phase failure protection Conforms to IEC Standards EN60947-1, EN60947-4-1, EN60947-5-1 Approval standards UL508, UL File No. E158813 Ordering Information THERMAL OVERLOA RELAYS Part number is indicated on the label of the thermal overload relay. YS1T-RHA Completed Part Number of Thermal Overload Relay 1 Product Series Applicable Maximum Motor Current 5F: 5A, contactor sizes 9F,1F, 0F, 5F 38F: 40A, contactor sizes 3F, 38F 65F: 65A, contactor sizes 40F, 50F, 65F 15F: 15A, contactor sizes 80F, 100F, 15F 150F: 150A, contactor sizes 150F or 180F 180F: 180A, contactor sizes 150F or 180F *300F: 300A, contactor size 0F or 300F *400F: 400A, contactor size 0F or 300F Note: *With Current Transformer (CT) 4 Function : 3-element Type with Phase Failure Protection 3 Current setting range code P13 : P0 : P30 : P50 : P80 : 1P3 : 1P5 : P0 : 3P0 : 5P0 : 7P0 : 8P5 : 11P : 15P : 1P : 7P : 3P : 35P : Adjustable current range 0.1-0.16 0.16-0.5 0.5-0.4 0.4-0.63 0.63-1 1-1.6 1.5-1.6 -.5.5-4 4-6 5.5-8 7-10 9-13 1-18 17-5 3-3 8-36 30-40 Current setting range code 43P : 56P : 68P : 80P : 105 : 10* : 135 : 155 : 160* : 180* : 40* : Note :*With CT Adjustable current range 37-50 48-65 55-80 65-95 85-15 96-155 110-160 15-185 18-00 150-40 19-300 Verify appropriate current setting range code with the correct size overload using the complete part list on the following page. Notes: 1. Use the above ordering information only when interpreting part numbers. o not use for developing part numbers.. For applicable combinations of contactors and thermal overload relays, please consult following page. 3. For specifications and settings please see pages -16 through -34. www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -9

YS Series Thermal Overload Relays Product Series Current Range Range Code Part Number for Overload Applicable Contactor Size YS1T-RHA5F YS1T-RHA38F YS1T-RHA65F YS1T-RHA15F YS1T-RHA150F YS1T-RHA180F *YS1T-RHA300F *YS1T-RHA400F *with current transformer 0.1-0.16A P13 YS1T-RHA5FP13 0.16-0.5A P0 YS1T-RHA5FP0 0.5-0.4A P30 YS1T-RHA5FP30 0.40-0.63A P50 YS1T-RHA5FP50 0.63-1.0A P80 YS1T-RHA5FP80 1.0-1.6A 1P3 YS1T-RHA5F1P3 1.5-.0A 1P5 YS1T-RHA5F1P5 1.6-.5A P0 YS1T-RHA5FP0.5-4.0A 3P0 YS1T-RHA5F3P0 4.0-6.0A 5P0 YS1T-RHA5F5P0 5.5-8.0A 7P0 YS1T-RHA5F7P0 7.0-10.0A 8P5 YS1T-RHA5F8P5 9.0-13.0A 11P YS1T-RHA5F11P 1.0-18.0A 15P YS1T-RHA5F15P 17.0-5.0 1P YS1T-RHA5F1P 9-13A 11P YS1T-RHA38F11P 1-18A 15P YS1T-RHA38F15P 17-5A 1P YS1T-RHA38F1P 3-3A 7P YS1T-RHA38F7P 8-36A 3P YS1T-RHA38F3P 30-40A 35P YS1T-RHA38F35P 1-18A 15P YS1T-RHA65F15P 17-5A 1P YS1T-RHA65F1P 3-3A 7P YS1T-RHA65F7P 8-36A 3P YS1T-RHA65F3P 30-40A 35P YS1T-RHA65F35P 37-50A 43P YS1T-RHA65F43P 48-65A 56P YS1T-RHA65F56P 37-50A 43P YS1T-RHA15F43P 48-65A 56P YS1T-RHA15F56P 55-80A 68P YS1T-RHA15F68P 65-95A 80P YS1T-RHA15F80P 85-15A 105 YS1T-RHA15F105 65-95A 80P YS1T-RHA150F80P 85-15A 105 YS1T-RHA150F105 105-160A 135 YS1T-RHA150F135 85-15A 105 YS1T-RHA180F105 105-160A 135 YS1T-RHA180F135 15-185A 155 YS1T-RHA180F155 96-150A 10 YS1T-RHA300F10 150-40A 180 YS1T-RHA300F180 18-00A 160 YS1T-RHA400F160 00-300A 40 YS1T-RHA400F40 YS-9F YS-1F YS-0F YS-5F YS-3F YS-38F YS-40F YS-50F YS-65F YS-80F YS-100F YS-15F YS-150F YS-180F YS-150F YS-180F YS-0F YS-300F -10 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

YS Series YS Series Starters Ordering Instructions for an Assembled Starter STARTERS (Contactors with Thermal Overload Relay) Select the appropriate contactor (AC or C, reversing or non-reversing) from pages -5 through -8. Select the correct size overload from page -9 throught -10. The complete assembled part number is the same as the contactor with the following changes: (See examples below) Completed Part Number of Reversing Starter YSR - F 11 **** T### 1 Product Series YS1N contactor ----> YSN AC non-reversing Starter YS1R contactor ----> YSR AC reversing Starter YS3N contactor ----> YS4N C non-reversing Starter YS3R contactor ----> YS4R C reversing Starter Maximum AC3 Current (replaced exactly from contactor P/N) F: is replaced by size, 9-300 for AC controlled FG: is replaced by size, 9-65 for C controlled FG: is replaced by size, 80-15 for C controlled 3 Thermal Overload Relay : 3-element Type with Phase Failure Protection 4 Auxiliary Contact Configuration (Replaced exactly from contactor P/N) 01: with 1, for contactor sizes 9F-1F 10: with 1, for contactor sizes 9F-1F 11: with 1-1, for contactor sizes 0F-65F : with -, for contactor sizes 80F-300F 5 Coil Voltage (Replaced exactly from contactor P/N) 6 Thermal Overload Relay, Type YS1T-RHA T: Thermal Overload Relay + ###: Three character code designating of Current Setting Range Code (See page -10.) EXAMPLE #1 : Contactor : YS1R-9F10A10 + Overload: YS1T-RHA5F5P0 1 4 5 6 STARTER: YSR-9F10A10T5P0 1 3 4 5 6 EXAMPLE # : Contactor : YS3N-65FG1104 + Overload: YS1T-RHA65F43P 1 4 5 6 STARTER: YS4N-65FG1104T43P 1 3 4 5 6 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -11

Accessories Accessories Accessory escription Part Number Notes Auxiliary Contact Blocks Number of Poles Poles 4 Poles Mounting Style Contact Configuration Side 1 1 YS1A-TAS11F Top 0 YS1A-TAH0F 1 1 YS1A-TAH11F 0 YS1A-TAH0F 0 4 YS1A-TAH404F 1 3 YS1A-TAH413F YS1A-TAH4F 3 1 YS1A-TAH431F Auxiliary contacts only available for contactors from 9F through 65F. Replacement Auxiliary Contact Block Power Wire Kits 4 0 YS1A-TAH440F Poles Side 1 1 YS1A-TAS11FL For use with YS-9F through YS-1F YS9Z-KIF411344-A For use with YS-0F through YS-5F YS9Z-KIF411345-A For use with YS-3F through YS-38F YS9Z-KIF411346-A For use with YS-40F through YS-65F YS9Z-KIF411347-A For use with YS-80F through YS-15F YS9Z-KIF411348-A Replacements for attached auxiliary contact blocks on contactors 80F through 300F For use with YS-150F YS9Z-KIF411588-A For use with YS-180F YS9Z-KIF411588-B For use with YS-0F through YS-300F YS9Z-KIF411590-A Mechanical Interlock For use with YS-9F through YS-65F YS9Z-TMI65 For use with YS-80F through YS-300F YS9Z-TMI15 Marking Tags For use with YS-9F through YS-65F YS9Z-TIP66 Overload IN Rail Bracket For use with YS1T-RHA65F overload YS9Z-TIB65F Assembled Pushbutton for Overload Reset w/ Extension Rod Blank Cap / No engraving Cap engraved with R Cap engraved with RESET Sub Assembled Operator Blank Cap / No engraving HW1B-M1RS-*T HW1B-M1RS-*T-ENG-R HW1B-M1RS-*T-ENG-RESET HW1B-M0 HW1A-B1-* * Choose cap color B= Black Y= Yellow N= Gray G= Green S= Blue R= Red W=White Rod (10 inch length; adjustable) HW9Z-RS-TK141-1 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Accessories Accessories, continued Accessory escription Part Number * Applicable Size Codes Surge Suppressor Type Rated Voltage Relay Interface Module RC Circuit Varistor 50-17V AC YS9Z-TU*C10 110-40V AC YS9Z-TU*C40 50-17V AC YS9Z-TU*V10 110-40V AC YS9Z-TU*V40 380-440V AC YS9Z-TU*V440 Isolates the coil of contactor from PLC output by providing an easy to mount module that takes 4V C input and switches up to 380V AC for contactor coils. External source required for contactor coil. Star (Wye) elta Timer Input Voltage Contact Style Replacement Coils 100V AC to 40V AC 50/60 Hz AC Coils for AC Contactors Star: elayed SPST- elta: elayed SPST- Star: elayed SPST- elta: elayed SPST- Instantaneous SPST- For use with YS-9F through YS-1F For use with YS-0F through YS-5F For use with YS-3F to YS-38F For use with YS-40F to YS-65F For use with YS-80F to YS-15F For use with YS-150F to YS-180F For use with YS-0F to YS-300F C Coils for C Contactors 9F through 65F For use with YS-9F through YS-5F For use with YS-3F through YS-38F For use with YS-40F through YS-65F C Coils for C Contactors 80F through 15F For use with YS-80F through YS-15F # 8-pin 11-pin 8-pin 11-pin AC/C Module for 80F through 15F C coils only 100V AC/C Module for YS-80F through YS-15F 00V AC/C Module for YS-80F through YS-15F YS9Z-TCU500UH* GT3S-1AF0 GT3S-1EAF0 GT3S-AF0 GT3S-EAF0 YS9Z-KIL70461-* YS9Z-KIL7046-* YS9Z-KIL70463-* YS9Z-KIL70464-* YS9Z-KIL70518-* YS9Z-KIL70466-* YS9Z-KIL70467-* YS9Z-KIL7056-* YS9Z-KIL70564-* YS9Z-KI411880-* YS9Z-KIL70519-* YS9Z-KIFCA840546A YS9Z-KIFCA840546B 5 = YS-9F to YS-5F 65 = YS-3F to YS-65F 15 = YS-80F to YS-15F 180 = YS-150F to YS-180F 300 = YS-0F to YS-300F 1 = YS-9F to YS-1F 5 = YS-0F- to YS-5F 38 = YS-3F to YS-38F 65 = YS-40F to YS-65F 15 = YS-80F to YS-15F 180 = YS-150F to YS-180F 300 = YS-0F to YS-300F See Section G for further information A04 = 4V AC 50/60 Hz A048 = 48V AC 50/60 Hz A10 = 10V AC 50/60 Hz A40 = 40V AC 50/60 Hz A380 = 380V AC 50/60 Hz A480 = 480V AC 50/60 Hz A600 = 600V AC 50/60 Hz 04 = 4V C 048 = 48V C 110 = 110V C 0 = 0V C 110 = 110V C 0 = 0V C Used in conjunction with YS9Z-KIL-70519-* for C coils 80F through 15F only. # YS9Z-KIL70519* is available ONLY in 110V (110) or 0V (0) models. www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -13

Accessories Accessories, continued Accessory escription Part Number 6 pieces required per contactor 3 pieces required per contactor Stationary Main Contacts For use with YS-0F For use with YS-5F For use with YS-3F For use with YS-38F For use with YS-40F For use with YS-50F For use with YS-65F For use with YS-80F For use with YS-100F For use with YS-15F For use with YS-150F For use with YS-180F For use with YS-0F For use with YS-300F Moving Main Contacts For use with YS-0F For use with YS-5F For use with YS-3F For use with YS-38F For use with YS-40F For use with YS-50F For use with YS-65F For use with YS-80F For use with YS-100F For use with YS-15F For use with YS-150F For use with YS-180F For use with YS-0F For use with YS-300F each part number is for ONE (1) main contact YS9Z-KIF409056-A YS9Z-KIF409057-A YS9Z-KIF410179-A YS9Z-KIF410180-A YS9Z-KIF409083-A YS9Z-KIF409083-B YS9Z-KIF409083-C YS9Z-KIF410697-A YS9Z-KIF410697-B YS9Z-KIF410697-C YS9Z-KIF410853-A YS9Z-KIF410854-A YS9Z-KIF411841-A YS9Z-KIF41184-A YS9Z-KIF409059-A YS9Z-KIF409060-A YS9Z-KIF410167-A YS9Z-KIF410168-A YS9Z-KIF409155-A YS9Z-KIF409155-B YS9Z-KIF409155-C YS9Z-KIF410698-A YS9Z-KIF410698-B YS9Z-KIF410698-C YS9Z-KIF410856-A YS9Z-KIF410857-A YS9Z-KIF411843-A YS9Z-KIF411844-A All part numbers refer to one piece quantity (not sets). -14 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Accessories Accessories, continued Part Number escription For Use With BAA1000 35mm Aluminum IN Rail 7.5 mm deep 1 meter long YS1N-9F through YS1N-38F Contactors BNN1000 35mm Aluminum IN Rail 10.5 mm deep. 1 meter long YS1N-9F through YS1N-38F Contactors YS9Z-TIP66 Markers BNL8 Plastic replacement markers sold in 100 piece packs IN Rail End Stop used to prevent contactors from sliding on IN rails YS-9F through YS-65F series contactors, overloads relays and top mount auxiliary contact blocks. YS1N-3F/YS1N-38F & YS1R reversing contactors BNL5 IN Rail End Stop used to prevent contactors from sliding on IN rails YS1N-9F YS1N-1F YS1N-0F YS1N-5F Contactors SRP-05C 8-pin IN mount Finger-safe (IP0) screw terminal socket GT3S-1AF0 timer (8 pin) GT3S-AF0 timer (8 pin) SRP-06 8-pin IN mount screw terminal socket open terminal construction GT3S-1AF0 timer (8 pin) GT3S-AF0 timer (8 pin) SR3P-05C 11-pin IN mount finger-safe (IP0) screw terminal socket GT3S-1EAF0 timer (11pin) GT3S-EAF0 timer (11pin) SR3P-06 11-pin IN mount screw terminal socket open terminal construction GT3S-1EAF0 (11 pin) GT3S-EAF0 (11 pin) www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -15

Specifications Specifications Contactor Circuit Supply: AC Characteristics Part Number YS1N 9F 1F 0F 5F 3F 38F 40F 50F 65F 80F 100F 15F 150F 180F 0F 300F Rated Insulation Voltage V 690 690 690 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Conformity to Standards Approvals NFC 63-110; VE 0660; BS 544; JEM 1038; EN60947-1, 60947-4-1; UL508 UL, c-ul egree of Protection Finger-safe (according to VE 0106) ry Ambient Air Temp. for Storage 1/4C -40 to +80 ry Ambient Air Temp. for Operation 1/4C -10 to +55 (0.85 to 1.1 Un) Operating Altitude m 000 Operating Position (without derating Main Power Pole Utilization Characteristics: ±301/4 compared with the normal vertical mounting plane (see table on -) Number of Poles: 3 Part No. 9F 1F 0F 5F 3F 38F 40F 50F 65F 80F 100F 15F 150F 180F 0F 300F Rated Operational Current in AC3 A 9 1 18 5 30 40 40 50 65 80 105 15 150 180 0 300 in AC1 A 0 0 30 30 50 60 60 80 80 135 150 150 00 40 60 350 Rated Operational Voltage V 660 660 690 690 690 690 690 690 690 690 690 690 690 690 690 690 Maximum Thermal Current Ith ( 55 C) A 0 0 35 35 50 60 60 80 80 135 150 150 00 40 60 350 Making Capacity I rms A 150 150 80 300 480 480 800 800 800 1500 1500 1500 1800 100 500 3500 Breaking Capacity 0-380- 415-440V A 10 150 50 300 380 480 500 600 700 800 1100 1300 1500 1800 100 3000 I rms 500V A 100 10 00 50 300 400 400 500 550 800 1000 1100 100 1600 1900 00 According to EN 60158-1 660-690V A 90 100 10 180 50 350 350 400 430 500 750 80 1100 100 1400 1800 Wiring, minimum-maximum wire size: Stranded Wire (without ferrule) 1 Conductor Conductors mm 1-4 1-4 1.5-10 1.5-10 4-16 4-16 5-5 5-5 5-5 8-60 8-60 8-60 8-100 8-100 14-150 14-150 AWG 18-10 18-10 16-8 16-8 1-6 1-6 10-3 10-3 10-3 8-0 8-0 8-0 8-4/0 8-4/0 4-300mcm 4-300mcm mm 1-4 1-4 1.5-6 1.5-6 4-8 4-8 5-16 5-16 5-16 8-35 8-35 8-35 8-50 8-50 14-80 14-80 AWG 18-10 18-10 16-10 16-10 1-8 1-8 10-5 10-5 10-5 8-8- 8-8-1 8-1 4-3/0 4-3/0 Solid Wire (without ferrule) 1 Conductor Conductors mm 1-4 1-4 1.5-6 1.5-6 4-10 4-10 5-5 5-5 5-5 AWG 18-10 18-10 16-10 16-10 1-8 1-8 10-3 10-3 10-3 mm 1-4 1-4 1.5-6 1.5-6 4-10 4-10 5-16 5-16 5-16 AWG 18-10 18-10 16-10 16-10 1-8 1-8 10-5 10-5 10-5 -16 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Specifications Control Circuit Characteristics: Part Number YS1N- 9F 1F 0F 5F 3F 38F 40F 50F 65F 80F 100F 15F 150F 180F 0F 300F Rated AC Control Voltage (50 or 60 Hz) : Un V Un: 4 to 600 Coil Limits ( 55 C) Operating Limits Un 85% to 110% Un rop-out Voltage Un 30% to 70% Un Coil Power Consumption (0 C) in Un Inrush VA 55 55 85 85 150 150 170 170 170 76 76 76 819 819 805 805 AC 50 Hz Cos Ø (power factor) 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0. 0. Sealed VA 8 8 8 8 15 15 16 16 16 40 40 40 53 53 100 100 AC 60 Hz Coil Power Consumption Cos Ø (power factor) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.37 0.37 Inrush VA 50 50 80 80 130 130 150 150 150 31 31 31 714 714 700 700 Cos Ø (power factor) 0.7 0.7 0.7 0.7 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.1 0.1 Sealed VA 6 6 6 6 1 1 13 13 13 9 9 9 38 38 88 88 Cos Ø (power factor) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.37 0.37 50 Hz W 1.5 to.5 1.5 to.5 1.5 to.5 1.5 to.5 3.5 to 5.0 3.5 to 5.0 3.7 to 5. 3.7 to 5. 3.7 to 5. 7.5 to 11 7.5 to 11 7.5 to 11 1 to 16 1 to 16 19 to 7 19 to 7 60 Hz W 1.0 to.0 1.0 to.0 1.0 to.0 1.0 to.0 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 6.0 to 8.5 6.0 to 8.5 6.0 to 8.5 9.0 to 13 9.0 to 13 16 to 3 16 to 3 Mechanical Life at Rated Control Voltage (Un) ( 10 6 operating cycles) 10 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 Switching Frequency Minimum-Maximum Wire Size Mechanical 9000 9000 9000 9000 9000 9000 9000 9000 9000 700 700 700 700 700 5000 5000 ops/h Electrical AC3 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Stranded Wire (without ferrule) Solid Wire (without ferrule) 1 Conductor Conductors 1 Conductor Conductors mm 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 mm 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 mm 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 mm 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -17

Specifications Coil Resistance: Coil Voltage Resistance (Ω) YS1N-9F/1F YS1N-0F/5F YS1N-3F/38F YS1N-40F/50F/65F YS1N-80F/100F/15F YS1N-150F/180F YS1N-0F/300F 4V 50/60Hz 7.90 4.8 1.68 1.7 0.39 0.98 0.107 48V 50/60Hz 33.9 19.1 7.1 6.3 1.85 1.18 0.378 110V 50/60Hz 174.4 101 36.6 39.1 8.67 6.46.630 10V 50/60Hz 196.3 1 44. 45. 11.6 7.1 3.186 08V 50/60Hz 619.5 385 134 137.4 33.3 3. 8.310 0V 50/60Hz 748.0 397 153 139.0 35.6 4.8 8.840 30V 50/60Hz 776.0 486 153 16.0 37. 30 9.340 40V 50/60Hz 841.8 513 164 177.8 45.6 31.4 9.810 380V 50/60Hz 577.0 1310 458 46.0 11 8.38 415V 50/60Hz 81.1 1480 501 56.5 133 96.6 8.70 480V 50/60Hz 3166.4 050 675 757.1 18 19. 6.71 500V 50/60Hz 37.7 170 790 794.0 191 135. 66.5 600V 50/60Hz 5136.3 3100 116 1046.7 75 06 100.3 Operating Time: Frame Size Contactor 50Hz 60Hz Basic Part Number Main Closing (msec) Opening (msec) Closing (msec) Opening (msec) Aux. () Aux. () Main Aux. () Aux. () Main Aux. () Aux. () Main Aux. () Aux. () 1 5 38 65 15 180 300 YS1N-9F YS1N-1F YS1N-0F YS1N-5F YS1N-3F YS1N-38F YS1N-40F YS1N-50F YS1N-65F YS1N-80F YS1N-100F YS1N-15F YS1N-150F YS1N-180F YS1N-0F YS1N-300F 11 to 17 11 to 17 8 to 1 5 to 13 5 to 13 7 to 14 10 to 15 10 to 15 7 to 1 5 to 13 6 to 14 7 to 15 14 to 15 to 9 to 16 3 to 13 6 to 13 9 to 17 13 to 0 13 to 0 9 to 13 to 1 7 to 13 9 to 17 15 to 3 15 to 3 8 to 16 6 to 15 7 to 15 1 to 3 16 to 4 16 to 4 9 to 16 5 to 14 7 to 15 11 to 1 14 to 16 to 4 10 to 16 6 to 17 5 to 17 11 to 3 15 to 15 to 9 to 16 7 to 16 7 to 16 11 to 0 10 to 7 10 to 6 6 to 19 6 to 0 6 to 0 10 to 6 13 to 31 1 to 30 8 to 6 to 18 6 to 18 10 to 4 17 to 34 16 to 31 13 to 31 8 to 5 8 to 8 1 to 9 1 to 39 0 to 36 13 to 9 5 to 7 to 11 to 9 17 to 36 16 to 36 13 to 33 8 to 7 8 to 30 1 to 31 to 41 1 to 38 13 to 31 5 to 4 7 to 4 11 to 31 Notes: 1. The operating time depends on the type of contactor electromagnet and its control mode.. The closing time is measured from the time the coil power supply is switched on to the time the main contacts first make contact. 3. The opening time is measured from the time the coil power supply is switched off to the time the main contacts separate. 4. The duration of the arcing time depends on the type of circuit switched by the poles. 5. For normal three-phase applications the duration of the arcing time is normally less than 10 ms. 6. The load is isolated from the coil power supply after a time equal to: the sum of the opening time and the arcing time. -18 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Specifications Contactor Circuit Supply: C Operating Coil Characteristics Part Number YS3N-9FG YS3N-1FG YS3N-0FG YS3N-5FG YS3N-3FG YS3N-38FG YS3N-40FG YS3N-50FG YS3N-65FG YS3N-80FG YS3N-100FG YS3N-15FG Coil Voltage (V) Exciting Current (ma) Pick-Up Voltage (V) rop-out Voltage (V) Coil Resistance ( 1 / ) Power Consumption (W) 4V C 14 to 6 10 to 15 5 to 10 10 5.1 to 6.4 48V C 108 to 13 1 to 30 10 to 0 404 5.1 to 6.4 100V C 51 to 64 45 to 63 1 to 40 1750 5.0 to 6.5 00V C 6 to 33 90 to 15 43 to 80 6870 5.1 to 6.8 4V C 14 to 6 10 to 15 5 to 10 10 5.1 to 6.4 48V C 108 to 13 1 to 30 10 to 0 404 5.1 to 6.4 100V C 51 to 64 45 to 63 1 to 40 1750 5.0 to 6.5 00V C 6 to 33 90 to 15 43 to 80 6870 5.1 to 6.8 4V C 335 to 410 11 to 16 4 to 8 65.1 8.0 to 9.9 48V C 165 to 0 3 to 3 8 to 16 64 7.8 to 9.8 100V C 76 to 94 48 to 66 18 to 3 1190 7.5 to 9.5 00V C 36 to 45 96 to 13 36 to 64 4970 7.0 to 9.1 4V C 516 to 630 13 to 17 4 to 7 4.3 1.3 to 15. 48V C 15 to 63 7 to 33 8 to 13 03 10.3 to 1.7 100V C 103 to 17 58 to 69 17 to 7 880 10. to 1.8 00V C 53 to 66 116 to 137 35 to 53 3390 10.4 to 13.3 100V C 19 to 4 76 to 84 43 to 54 00V C 11 to 15 133 to 144 86 to 98 Standard Operating Time Coil Applied Voltage 100%Uc Part Number Closing Time (ms) Opening Time (ms) Main Aux. () Aux. () Main Aux. () Aux. () YS3N-9F 1 38 to 45 38 to 45 5 to 10 5 to 10 YS3N-1F 1 38 to 45 38 to 45 6 to 1 8 to 13 YS3N-0FG, -5FG 45 to 53 45 to 53 36 to 46 6 to 1 6 to 1 10 to 16 YS3N-3FG, -38FG 59 to 68 57 to 66 46 to 56 7 to 19 7 to 19 14 to 3 YS3N-40FG, -50FG, -65FG 46 to 56 46 to 56 34 to 47 3 to 3 3 to 3 7 to 36 YS3N-80FG, -100FG, -15FG 3 to 4 3 to 4 4 to 36 36 to 56 36 to 56 4 to 6 Operating Limited istances Rated Operational Voltage 100VC Rated Operational Voltage 00VC Part Number Coil Applied Voltage 100VC Coil Applied Voltage 00VC Wire Sectional Area Wire Sectional Area 1.5mm mm 3.5mm 1.5mm mm 3.5mm YS3N-9FG, -1FG 3. km 5.0 km 9. km 1.6 km 19.7 km 36.4 km YS3N-0FG, -5FG 3. km 5.0 km 9. km 1.6 km 19.7 km 36.4 km YS3N-3FG, -38FG.1 km 3.4 km 6.3 km 9.1 km 14.3 km 6.3 km YS3N-40FG, -50FG, -65FG 1.6 km.5 km 4.6 km 6. km 9.7 km 18.0 km YS3N-80FG, -100FG, -15FG 0.136 km 0.13 km 0.39 km 0.507 km 0.794 km 1.46 km www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -19

Specifications Electrical Life Curves Electrical Life Curves Fig.1 Utilization Category AC3 Millions of Operating Cycles 10 YS1N-9F YS1N-1F YS1N-0F YS1N-38F,-40F YS1N-50F YS1N-65F YS1N-80F YS1N-100F YS1N-15F YS1N-150F YS1N-180F YS1N-0F YS1N-300F AC3 Ue < 440V 5 4 3 1 0.5 0.4 0.3 YS1N-5F 0. 1 3 4 5 10 0 30 40 50 100 150 00 300 400 500 1000 9 1 18 5 65 105 15 180 09 Breaking current Ic (A) 50 0.55 0.75 1.5. 4 5.5 7.5 11 15 18.5 30 37 45 55 65 90 140 0 80 0V 0.55 0.75 1.5. 4 5.5 7.5 11 15 18.5 30 37 55 75 110 160 00 50 450 380V 0.55 0.75 1.5. 4 5.5 7.5 11 15 18.5 30 37 55 75 90 13 00 80 45 440V Power rating in kw - 50 Hz category AC3 YS1N-3F Control of three-phase squirrel cage motors switching off during running The breaking current in AC3, Ic, is equal to Ie. (le= rated operational current of the motor) Fig. Utilization Category AC4 Millions of Operating Cycles 1 YS1N-9F YS1N-1F YS1N-0F YS1N-38F,-40F YS1N-50F YS1N-65F YS1N-80F YS1N-100F YS1N-15F YS1N-150F YS1N-180F YS1N-0F YS1N-300F AC4 380V < Ue 440V 0.5 0.4 0.3 0. 0.1 0.05 0.04 0.03 0.0 0.01 Breaking current Ic (A) 10 0 30 40 YS1N-5F YS1N-3F 50 100 00 300 400 500 1000 000 3000 4000 5000 51 69 10 13 180 34 360 510 70 88 1454 850 111 7 588 100 1998 Control of three-phase squirrel cage motors switching off with locked rotor The breaking current in AC4, Ic, is equal to 6 x Ie. (Ie = rated operational current of the motor) -0 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Specifications Fig. 3 Utilization Category AC1 Millions of Operating Cycles 10 YS1N-9F YS1N-1F YS1N-0F YS1N-38F,-40F YS1N-50F YS1N-65F YS1N-80F YS1N-100F YS1N-15F YS1N-150F YS1N-180F YS1N-0F YS1N-300F AC1 Ue < 440V 5 4 3 YS1N-5F 1 0.5 0.4 0.3 0. 0.1 1 3 4 5 10 0 30 40 50 100 150 00 40 300 400 500 60 350 Breaking current Ic (A) Switching a resistive circuit (cos ø 0.95) The breaking current in AC1, Ic, is equal to Ie. (le = rated operational current of the load) YS1N-3F Electrical Life in Mixed AC3/AC4 uty Applications By calculation: In a mixed AC3/AC4 application, electrical life can be calculated using the following formula: L = A3 1+ P ( A3-1 ) 100 A4 L: Electrical life in mixed AC3/AC4 application A3: Electrical life for breaking current equal to the rated current of the motor. (AC3 from Fig. 1) A4: Electrical life for a breaking current during starting or plug braking equal to Ic = Kle, where: K 6 Ie = rated motor current (AC4 from fig. ) P/100: ratio of switching off during starting or plug braking www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -1

Specifications 1. Operating Specifications Operating and Mounting Specifications for Contactors and Starters Ambient Temperature Temperature inside the control panel Relative humidity. Mounting -5 to +40 C -5 to +55 C 45% to 85% RH Altitude No more than,000m Vibration resistance Shock resistance Storage temperature 10 to 50Hz 19.6m/s (G) 49.0m/s (5G) -40 C to +70 C irect Mounting 1. Install the product in a dry area with minimal dust and vibration.. Standard mounting is done on a vertical surface in the directions shown in Figure 1. However, a mounting angle up to 30 degrees is allowed in each direction as shown in Figure. Operational characteristics of the product, when mounted with these angles are listed on the next page. 30 30 30 30 Figure 1 Figure IN Rail Mounting YS Series electromagnetic contactors/starters YS1N/YSN-9F through -38F models can be mounted on 35mm wide IN rail, and YS1N/ YSN -40F through -65F models can be mounted on 75 mm wide IN rails, as specified in the table below. When mounting the product on IN rails, keep in mind the following points: 1. Spacing between the products: contributes to a temperature rise and affects the product life. Maintain the minimum spacing as specified in the table below. IN rail mounting holes: To ensure sufficient mechanical strength, the mounting holes should be placed no further apart than those specified in the table below. Product Category IN rail width (mm) Minimum spacing between contactors (mm) istance between mounting screws (mm) Contactor Starter (G) (L) YS1N-9F YSN-9F 35 5 300 YS1N-1F YSN-1F 35 5 300 YS1N-0F YSN-0F 35 5 300 YS1N-5F YSN-5F 35 5 300 YS1N-3F YSN-3F 35 5 300 YS1N-38F YSN-38F 35 5 300 YS1N-40F YSN-40F 75 5 300 YS1N-50F YSN-50F 75 5 300 YS1N-65F YSN-65F 75 5 300 Minimum Space Between Contactors (mm) G istance Between Mounting Screws L L L Mounting Screw - www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Specifications Mounting Angle and Operational Characteristics of the YS1N, YSN, YS1R, YSR Contactor /Starter Nonreversing Reversing Maximum turn-on voltage (V) Minimum turn-off voltage (V) Coil Frequency (Hz) YS1N/ YSN YS1R/ YSR -9F -9F -1F -1F -0F -0F -5F -5F -3F -3F -38F -38F 50 60 50 60 50 60 50 60 50 60 50 60 Standard/ normal mounting 114 16 114 16 1 138 1 138 114 13 114 13 30 left 30 right 30 tilted forward 111 13 111 13 10 136 10 136 114 133 114 133 110 11 110 11 11 138 11 138 11 130 11 130 118 19 118 19 14 140 14 140 14 145 14 145 30 tilted backwards 104 10 104 10 115 13 115 13 99 114 99 114 Standard/ normal mounting 84 10 84 10 105 119 105 119 78 95 78 95 30 left 30 right 30 tilted forward 8 98 8 98 10 111 10 111 77 93 77 93 80 95 80 95 99 11 99 11 83 96 83 96 8 96 8 96 103 118 103 118 81 96 81 96 30 tilted backwards 78 90 78 90 101 117 101 117 78 91 78 91-40F -40F 50 60 114 13 114 133 11 130 14 145 99 114 78 95 77 93 83 96 81 96 78 91-50F -50F 50 60 116 138 117 135 116 137 131 149 107 18 91 110 88 108 87 106 86 106 84 105-65F -65F 50 60 116 138 117 135 116 137 131 149 107 18 91 110 88 108 87 106 86 106 84 105-80F -80F 50 60 13 134 13 134 13 134 137 137 13 134 83 8 83 8 83 8 83 8 83 8-100F -100F 50 60 13 134 13 134 13 134 137 137 13 134 83 8 83 8 83 8 83 8 83 8-15F -15F 50 60 13 134 13 134 13 134 137 137 13 134 83 8 83 8 83 8 83 8 83 8 Coils with the following rated voltage were used to obtain the above values: YS1N-9F to-65f: 00V 50Hz, 00-00V 60Hz YS1N-80F to-15f: 00-0V 50Hz, 00-0V 60Hz www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -3

Specifications Operating and Mounting Specifications for Thermal Overload Relays Ratings and Characteristics: Part Number:YS1T-RHA 5F- 38F- 65F- 15F- 150F- 180F- 300F- 400F- Contact Configuration 1+1 Number of Elements 3 Trip Free Reset Operation Convertible from manual to automatic Ambient Temperature Compensation -5 to +55 C ial esignation Rated current Setting Scale Indication Ampere (A) Main Circuit Operation Position ± 30 with respect to the normal position (See chart on page 65) Tripping Class Conforming to UL 508, EN 60947-4 10 Rated Insulation Voltage (V) 750 Range of Setting Current (A) 0.1-5 7-40 9-65 37-15 65-160 85-185 96-40 18-30 Stranded Wire without Ferrule Solid Wire without Ferrule 1 Conductor mm 0.1-5 5-5 5-5 8-60 8-100 8-100 14-150 14-150 Conductors mm 1.5-10 5-16 5-16 8-8-50 8-50 14-80 14-80 1 Conductor mm 1.5-6 5-5 5-5 - - - - - Conductors mm 1.5-6 5-16 5-16 - - - - - Characteristics of Auxiliary Contacts: Rated Thermal Current Rated Operational Current per EN 60947-5-1 AC (AC-15) C (C-13) 4 A Rated Voltage 4V AC 48V AC 110V AC 0V AC 380V AC 600V AC Rated Current 4A 4A 3A A 1.5A 0.3A Rated Voltage 4V C 48V C 110V C 0V C Rated Current 1A 0.5A 0.5A 0.1A Maximum Cross Section Minimum Cross Section Stranded Wire without Ferrule Solid Wire without Ferrule Stranded Wire without Ferrule Solid Wire without Ferrule 4mm (10AWG) 4mm (10AWG) 1mm (18AWG) 1mm (18AWG) UL / c-ul Ratings of Auxiliary Contacts: Rated Thermal Current 4A Rated Operational Current per UL 508 AC (C600) C (R300) Rated Voltage 10V AC 40V AC 480V AC 600V AC Rated Current 1.5A 0.75A 0.4A 0.3A Rated Voltage 15V C 50V C Rated Current 0.A 0.1A -4 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Specifications Fig. 4 Tripping Curves Average operating times, depending on the multiples of the current Tripping Time (sec.) 10000 5000 000 1000 500 00 100 50 0 10 5 1 0.5 1 1 5 10 0 Multiple of Current Setting 3 1 Balanced operation, 3-phase, from cold state. Balanced operation, -phase, from cold state. 3 Balanced operation, 3-phase, after a long period of set current flow (hot state). Reset Mode Selection and Setting H HAN AUTO A Function Position H R HAN AUTO A R Tripping Check YES YES Reset Hand-Reset Hand-Reset Auto-Reset Auto-Reset Contact Condition 97 98 95 96 97 98 95 96 otted line indicates the condition when the reset button is depressed. 97 98 95 96 Insert screwdriver into the select button, turn it clockwise to the "H" position. The select button is set in "HAN" position, when shipped from factory. epress the reset button to below 1, insert screwdriver into the select button, turn counter-clockwise to the "AUTO" position Insert screwdriver into the select button, turn counter-clockwise to the "A" position. Setting Method Select Button (Red) Reset Button (Gray) 1 Remarks Can't check manual trip when in Hand-reset condition Normal position for Hand-reset Normal position for Auto-reset Can't check manual trip when in Auto-reset condition www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -5

Specifications Operating Time Characteristics of Thermal Overload Relays YS1T-RHA38F, YS1T-RHA65F YS1T-RHA5F 1000 1000 500 500 Operating Time (In Seconds) YS1T-RHA15F 100 50 10 5 1 0.5 0.1 100 00 300 400 500 600 700 800 Current (% of Steady State) 1000 Starting Characteristic Load Characteristics Operating Time (In Seconds) YS1T-RHA150F 100 50 10 5 1 0.5 0.1 100 00 300 400 500 600 700 800 Current (% of Steady State) 1000 Starting Characteristic Load Characteristics 500 500 Operating Time (In Seconds) 100 50 10 5 1 0.5 Starting Characteristic Load Characteristics Operating Time (In Seconds) 100 50 10 5 1 0.5 Load Characteristics Starting Characteristic 0.1 100 00 300 400 500 600 700 800 Current (% of Steady State) 0.1 100 00 300 400 500 600 700 800 Current (% of Steady State) -6 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Specifications Operating Time Characteristics of Thermal Overload Relays, continued YS1T-RHA180F 1000 500 YS1T-RHA300F, YS1T-RHA400F 1000 500 Operating Time (In Seconds) 100 50 10 5 1 0.5 0.1 100 00 300 400 500 600 700 800 Current (% of Steady State) Starting Characteristics Load Characteristics Operating Time (In Seconds) 100 50 10 5 1 0.5 0.1 100 00 300 400 500 600 700 800 Current (% of Steady State) Load Characteristics Starting Characteristics www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -7

Specifications Specifications for Accessories AC Ratings of Auxiliary Contacts AC Ratings per EN AC Ratings (EN-60947-5-1) UL / c-ul AC Ratings (UL 508) Wire Sizes for Auxiliary Contacts YS1N-9F to -300F Rated Insulation Voltage (V) 660 Rated Thermal Current (A) 10 Rated Operational Current AC-15 (A) AC 00-40V 3 AC 380-480V 1.5 AC 500-600V 1. Rated Insulation Voltage (V) 600 Rated Thermal Current (A) 10 Rated Operational Current (NEMA A600) AC 10V 6 AC 40V 3 AC 480V 1.5 AC 600V 1. Minimum-Maximum Wire Size YS1N-9F to -300F Stranded Wire (without ferrule) Solid Wire (ferrule) 1 Conductor Conductors 1 Conductor Conductors mm (AWG) mm (AWG) mm (AWG) mm (AWG) 1-4 (18-10) 1-4 (18-10) 1-4 (18-10) 1-4 (18-10) Instructions for Assembling Auxiliary Contact Blocks: For each magnetic contactor/starter, up to four contacts of the auxiliary contact blocks can be mounted. Two contacts of the top-mount style and two contacts of the side mount style can be combined. YS1A-TAH YS1A-TAH4 YS1A-TAH YS1A-TAS YS1A-TAS YS1A-TAS YS1A-TAH YS1A-TAS YS1A-TAS YS1A-TAH4 YS1A-TAS YS1A-TAS Terminal Numbers and Mounting Examples of Auxiliary Contact Blocks, Side-Mount Style YS1N-9F to -65F YS1R-9F to -65F B @ A C R S T F E G U V W B @ A C R S T U V W R S F F B @ E E A G G C T U V W Note: If you would like to mount two side-mount auxiliary contact blocks (TAS style) to a YS1N non-reversing contactor, mount YS1A-TAS11F. -8 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Mounting and Removing Auxiliary Contact Block on the Contactor Specifications Top Mount Style 1. Position the contactor and the auxiliary contact block in the same direction.. Insert the auxiliary contact block into the area of the top of the contactor. Slide the auxiliary contact until it bottoms (o not force.) Make sure that the locking hook is locked into position as shown Removal Procedure While lightly lifting the locking hook with your finger, slide the auxiliary contact unit out. Side-Mount Style 1. Contactor plunger. Inside this area, there are locking hooks (upper and lower areas) IN rail Mounting 1. Make sure that the auxiliary contact block (right or left side) and the terminal numbers on the contactor are in the same direction.. Push the plunger of the contactor downwards approximately mm. While holding the plunger in this manner, insert the white protruding portion of the auxiliary contact block into the square groove of the side of the contactor. Make sure that the locking hook is locked into position. Removal Procedure Hold the auxiliary contact block and pull it off. www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -9

Specifications Surge Suppressor Module Connection Terminal (M3,5) 6. 4.7 Internal Circuit Operational Indicator (LE) 34 RC Type Varistor Type 6 Contactor Size Figure Number Operational Indicator (LE) Surge Suppressor Module Connection Terminal (M3,5) 6. 44 47 3 37 1 3 imensions A B C E RC Type Varistor Type Internal Circuit B YS1N-9F 1 YS9Z-TU5 78.5 100 1 76 64 C A E YS1N-1F 1 YS9Z-TU5 78.5 100 1 76 64 YS1N-0F YS9Z-TU5 85 103 1 91 75 YS1N-3F YS9Z-TU65 9 18 1 111 75 Figure 1 YS1N-38F YS9Z-TU65 9 18 1 111 88 B YS1N-50F YS9Z-TU65 114 16 1 11 88 C A YS1N-65F YS9Z-TU65 114 16 1 11 106 E YS1N-80F YS9Z-TU65 191 40 1.4 143.5 106 Figure Mounting Procedure 1. Line up the surge suppressor module and the contactor as shown in the figure on the right. (Make sure the orientation of the surge suppressor module is such that the LE is visible.). Insert the U-shaped indentations of the surge suppressor module into the connection flange of the contactor as shown in the figure on the right. 3. Loosen the contactor screws, insert the fork lugs of the surge suppressor module, and re-tighten the screw terminals. Removal Procedure 1. Loosen coil screw terminals and remove the fork lugs of the surge suppressor module.. Insert a screwdriver between the U-shaped indentation of the surge suppressor module and the connection flange of the contactor, and pry the module off the contactor. Connection indentation, U-shaped(on both sides of the surge suppressor module) Connection flange -30 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC

Specifications of Relay Interface Module Specifications YS9Z-TCU500UH Rated Voltage 4V C Maximum Allowable Voltage 130% of rated voltage Input (coil) Power Consumption 0.W Pick-up Voltage (at 0 C) 70% of rated voltage rop-out Voltage (at 0 C) 10% of rated voltage Maximum Operational Voltage 380V AC Rated Operational Current (at 50V AC) A (cosø=0.4) Output (contact) Thermal Current 5A Temperature Range Closing elay Opening elay 3 ms 1 ms -0 to +55 C Surge Suppressor evice Relay Interface Completed Part Numbers Product Series Maximum Operational Voltage Function Applicable Control Coil Voltage Range Applicable Contactor Completed Part Number imensions W H 50V AC Resistor capacitor circuit (RC) Up to 40V AC (50/60 Hz) YS1N-9F YS1N-1F YS9Z-TCU500UH1 49 15 76 YS1N-0F YS1N-5F YS9Z-TCU500UH5 49 135 91 YS1N-3F YS1N-38F YS9Z-TCU500UH38 58 140 111 Relay Interface Module YS9Z-TCU YS1N-40F YS1N-50F YS1N-65F YS1N-80F YS1N-100F YS1N-15F YS9Z-TCU500UH65 75 160 11 YS9Z-TCU500UH15 100 187 133 H YS1N-150F YS1N-180F YS9Z-TCU500UH180 130 5 158 YS1N-0F YS1N-300F YS9Z-TCU500UH300 146 60 184 W TES: Each model is identical in electrical characteristics, mounting plate sizes representing the only difference. CONNECTION IAGRAM AN INTERNAL CIRCUIT OF THE RELAY INTERFACE MOULE b A (+) e c E RY d a MC ( ) f R C A1 PLC (RELAY INTERFACE MOULE) CONTACTOR www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC -31

Specifications Mechanical Interlock Blocks Reversing Contactors Contactor Size Mechanical Interlock Block imensions A B C YS1R-9F YS9Z-TMI65 78.5 100 1 76 YS1R-1F YS9Z-TMI65 78.5 100 1 76 YS1R-0F YS9Z-TMI65 85 103 1 91 YS1R-5F YS9Z-TMI65 85 103 1 91 YS1R-3F YS9Z-TMI65 9 18 1 111 YS1R-38F YS9Z-TMI65 9 18 1 111 YS1R-40F YS9Z-TMI65 9 18 1 111 YS1R-50F YS9Z-TMI65 114 16 1 11 YS1R-65F YS9Z-TMI65 114 16 1 11 YS1R-80F YS9Z-TMI15 191 40 1.4 143.5 YS1R-100F YS9Z-TMI15 191 40 1.4 143.5 YS1R-15F YS9Z-TMI15 191 40 1.4 143.5 YS1R-150F YS9Z-TMI15 39 300 1.4 169.5 YS1R-180F YS9Z-TMI15 39 300 1.4 169.5 YS1R-0F YS9Z-TMI15 69 305 1.4 195 YS1R-300F YS9Z-TMI15 69 305 1.4 195 Note: 1. The mounting holes are the same as theys1 Series.. The above figures are not drawn to scale. Refer to the chart for actual dimensions. 3. YS1N-80F~-300F size contactors require an additional mounting base. Refer to the YS1R-80F through -300F in the dimension chart. B C A Reversing Starters Contactor Size Mechanical Interlock Block imensions A B C YSR-9F YS9Z-TMI65 78.5 100 1 76 YSR-1F YS9Z-TMI65 78.5 100 1 76 YSR-0F YS9Z-TMI65 85 103 1 91 YSR-5F YS9Z-TMI65 85 103 1 91 YSR-3F YS9Z-TMI65 9 18 1 111 YSR-38F YS9Z-TMI65 9 18 1 111 YSR-40F YS9Z-TMI65 9 18 1 111 YSR-50F YS9Z-TMI65 114 16 1 11 YSR-65F YS9Z-TMI65 114 16 1 11 YSR-80F YS9Z-TMI15 191 40 1.4 143.5 YSR-100F YS9Z-TMI15 191 40 1.4 143.5 YSR-15F YS9Z-TMI15 191 40 1.4 143.5 YSR-150F YS9Z-TMI15 39 300 1.4 169.5 YSR-180F YS9Z-TMI15 39 300 1.4 169.5 YSR-0F YS9Z-TMI15 69 305 1.4 195 YSR-300F YS9Z-TMI15 69 305 1.4 195 Note: 1. The mounting holes are the same as the YS1 Series.. The above figures are not drawn to scale. Refer to the chart for actual dimensions. 3. YS1N-80F through 300F contactors require an additional mounting base. Refer to the YSR-80F~-300F in the dimension chart. B C A -3 www.idec.com USA: (800) 6-IEC or (408) 747-0550, Canada: (888) 317-IEC