IEC Separable Connectors 17.5 kv/24 kv, 630A

Similar documents
IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

INSTALLATION PRODUCTION TESTS

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

15 kv Class Fused Loadbreak Elbow Connector with Interchangeable Fuse Capability

600 A 35 kv class BT-TAP deadbreak connector

600 A 25 kv class BT-TAP deadbreak connector

600 A 15 kv class T-OP II deadbreak connector

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

600 A 35 kv class separable splices

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

600 A 35 kv class deadbreak accessories, tools, and replacement parts

GROUP C. Apparatus Bushing.

600 A 15 and 25 kv class deadbreak accessories, tools, and replacement parts

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

Loadbreak Apparatus Connectors

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

25 kv class fused loadbreak elbow connector

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

25 kv Apparatus Bushings

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Product Description: Objective and Certification: Test Samples and Test Cable:

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK


Eaton s Cooper Power Systems

Molded Current-Limiting Fuse

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

High Voltage Joints and Terminations up to 72,5 kv 145 kv

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Medium Voltage. Joints & Terminations

15 kv and 25 kv Thru-Bushings

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

600 A 15 kv class Cleer loadbreak connector system

600 A 28 kv class Cleer loadbreak connector system

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

High Voltage Accessories up to 72.5 kv

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Branch Splice QS-2001B

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

AIR CORE REACTORS. Phoenix Electric Corporation

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

600 A 15 and 25 kv class Cleer grounding elbow

GROUP D. Switch & Protective device.

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Completing the picture

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Kuhlman Electric Corporation Volt Instrument Transformers

Separable Connectors and Kits

High Voltage Copper, Smooth Aluminum Shield/Sheath

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Portable High-Voltage Cable Couplers 415, 515

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

a Nexans company Catalogue 2009

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

a Nexans company Catalogue 2008

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

a Nexans company Catalogue 2011

High-voltage primary bushings installation instructions

a Nexans company Catalogue 2015

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

Kuhlman Electric Corporation Volt Instrument Transformers

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

Extensible Unit - VCE2a

CERTIFIED TEST REPORT. Cooper Power Systems. 25 kv Class 200 Amp 15.2/26.3 kv SEPARABLE CONNECTOR SYSTEM

Nexans Network Solutions Div. Euromold

Transcription:

IEC Separable Connectors 17.5 kv/24 kv, 630A Front T-Body / Coupling (Rear) T-Body Connector Application The Chardon T-Body connectors are used to terminate polymeric cable to dead front apparatus such as transformers, switchgear, and other equipment. They can be used at 17.5 kv and 24 kv. They can be used for indoor or outdoor applications, and can be used for all polymeric cable types (XLPE, EPR, etc.) with copper or aluminum conductors. Key Features Provides a fully shielded and submersible connection when mated with the proper bushing or plug. Type C 630A Interface. Mounting can be vertical, horizontal, or any angle in between. No minimum phase clearance requirements. 100% electrical tested at factory. Product Ratings Maximum Voltage Class (U ): AC 5 Minute Withstand: Minimum Corona Voltage Level: BIL and Full Wave Crest (Impulse): Thermal Short Circuit (Conductor, 2 sec.) Dynamic Short Circuit (Conductor, 10 sec.) Continuous Current Overload Current (8 hours maximum) Production Tests Tests conducted in accordance with IEC 60502-4 Minimum Corona Voltage Level 20 kv<3pc AC 5 Minute Withstand 54 kv m 24 kv 54 kv 20 kv < 3 pc 125 kv 23kA/2s 82 ka/10ms 630A 900A Tests conducted in accordance with Chardon manufacturing process requirements: Physical Inspection Periodic Dissection Periodic X-Ray analysis 24FDT630-36RDT630-061318-REV05

Detailed composition of the Chardon 17.5 kv/24 kv Front T-Body Connector www.chardongroup.com STUD Stainless steel studs RUBBER END CAP Molded EPDM conducting rubber end cap protects and grounds the insulating plug test point. INSULATING PLUG Molded epoxy insulating plug provides excellent electrical,thermal and mechanical reliability. CONDUCTING INSERT conducting insert provides corona-free electrostatic shielding of the compression connector. DRAIN WIRE TAB Drain wire table provide a convenient point to connect drain wire to ensure grounding of the connector shield. INSULATION LAYER High quality peroxide cured EPDM insulation is mixed and formulated in-house for complete control of rubber characteristics. CONDUCTING SHIELD conducting shield provides ground shield continuity COMPRESSION CONNECTOR/ SHEAR BOLT CONNECTOR Compression connector / shear bolt connector made of aluminum, copper, or bimetal(aluminum/copper). CABLE ADAPTER Molded cable adapter, sized to fit the cable insulation, provides stress relief for the terminated cable.

Detailed composition of the Chardon 17.5 kv/24 kv, Coupling (Rear) T-Body Connector www.chardongroup.com STUD Stainless steel studs RUBBER END CAP Molded EPDM conducting rubber end cap protects and grounds the insulating plug test point. INSULATING PLUG Molded epoxy insulating plug provides excellent electrical,thermal and mechanical reliability. CONTACT ROD Copper made contact rod provides a consistent current transfer path. CONDUCTING INSERT conducting insert provides corona-free electrostatic shielding of the compression connector. INSULATION LAYER High quality peroxide cured EPDM insulation is mixed and formulated in-house for complete control of rubber characteristics. CONDUCTING SHIELD conducting shield provides ground shield continuity DRAIN WIRE TAB Drain wire table provide a convenient point to connect drain wire to ensure grounding of the connector shield. COMPRESSION CONNECTOR/ SHEAR BOLT CONNECTOR Compression connector / shear bolt connector made of aluminum, copper, or bimetal(aluminum/copper). CABLE ADAPTER Molded cable adapter, sized to fit the cable insulation, provides stress relief for the terminated cable.

ORDERING INFORMATION 24 - STEP 1 STEP 1 STEP 2 STEP 3 Selection of Front / Rear T-body STEP 2 630 - Front T-Body Coupling (Rear) T-body Selection of Cable Insulation Dimension STEP 4 Code STEP 4 Selection of Compression Connector Material Note: When ordering a shear bolt connector in a kit, use the chart below and add code in the end of the part number, for example, SBC-B-25-50/1. Conductor Code for Shear Bolt Connector STEP 3 Selection of Conductor Size Conductor Code 25 35 50 70 95 120 150 185 240 300 Conductor Size (mm²) 25 35 50 70 95 120 150 185 240 300 CATALOG NO. SBC-B-25-50/1 SBC-B-70-95/1 SBC-B-70-120/2 SBC-B-150-240/2 ORDERING EXAMPLE: Conductor Range(mm2). 25-50 70-95 70-120 150-240 For a CHARDON 24kV Front T-body with cable insulation outer dimension of 26.4mm and a conductor size of 185mm² with copper compression connector, the part number would be as fallows: 24-FDT630C185C If a shear bolt connector is selected in this kit, the part number would be as follows: 24-FDT630CSBC-B-25-50/1

Chardon Taiwan Corporation No. 37 Min-Chie Road Tung Lo Industrial Park Miao Li, Taiwan 366 Phone: 886-3-798-4385 Fax: 886-3-798-4770