Powerstocc Excellent. Short Manual. PS DC Storage.

Similar documents
Short Manual. PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management

Short Manual. PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management

Short Manual. PIKO Inverter

Data sheet PIKO 12-20

Pre-announcement. Transformerless Solar Inverters

SolarMax P series The power package for residential solar plants

Data sheet PIKO 36 EPC EPC

Data sheet. PIKO MP plus

Data sheet. PLENTICORE plus. plus

Data sheet PIKO IQ

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

SolarMax MT series The all-rounder for trade and industry

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

SolarMax MT series. The power pack for maximum yields.

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Technical specifications

Catch Eco Range : Technical Specification Sheet

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

FRONIUS ENERGY PACKAGE

Sunny Tripower CORE1.

500 / 630 / 720 / 760 / 800 / 850 / 900

/ Optimised energy management. / Dynamic Peak Manager. / Smart Grid Ready 12.0 A / 12.0 A 18.0 A / 18.0 A

Certificate of Conformity self-generation unit

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Technical specifications

Sunny Tripower. Can do everything that we can

Get ready for rising energy challenges. This is where xstorage Home can help

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

SIZING OF SOLAR GENERATOR

PowerRouter Solar Battery Self-use

Power conversion systems for energy storage. Engineering that stores

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

Operating manual UPS - System

Technical Documentation

ABB central inverters PVS to 1000 kw

THREE-PHASE STORAGE SOLUTION EFFICIENT MODULAR REVOLUTIONARY

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

PV inverter SUNNY MINI CENTRAL 7000HV

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

photovoltaikforum.com

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Residential Energy Storage System SH 5K

Smart connections. Certificates. PIKO-Inverter

Residential Energy Storage System SH5K PV ESS

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

CONERGY CIS 1200 Manufactured By Bosch

Catalogue 2013 SOLPLUS Inverters and Accessories

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

Wind Power Inverter WINDY BOY 5000A/6000A

Oil-free piston compressors KK and piston vacuum pumps KV

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

PV inverter SUNNY BOY 2100TL

APS-PV-Series 1000 V DC

Price list - Inverter

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

SAJ Solar Inverter. Sununo Plus 1K/1.5K BENEFITS. Smart and Easy to Use. Flexible and Efficient. Safe and Reliable. Convenient Installation

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

+86(571) (571) (V4)

Tillers Motor hoes (combustion engine powered)

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

TANZANIA BUREAU OF STANDARDS

ABB central inverters PVS to 1000 kw

SUNNY BACKUP System. Solar Power Even in the Event of Grid Failure

Certificate of Conformity self-generation unit

Green Inverter from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

SolarMax MT A series A reliable solution for commercial PV applications

AXIAL FANS Axis / Tubo OPERATION MANUAL

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

i-energy i-micro inverter GT260

STRING INVERTERS IN ROOFTOP SOLAR. Anish Wastrad Fronius India Pvt Ltd.

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

PV Inverter SUNNY BOY 3300/3800

String Inverter (SUN KTL-A)

40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerValue 11/31 T kva

PowerScale TECHNICAL SPECIFICATIONS

Operating instructions

Wind Power Inverter WINDY BOY 3600TL / 5000TL

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

Transcription:

Powerstocc Excellent PS DC Storage Short Manual www.centrosolar.com

EU Declaration of conformity The company CENTROSOLAR AG Stresemannstr. 163, D-22769 Hamburg Tel. +49 (0)40 391065-0 hereby declares that the inverter Powerstocc DC Storage to which this declara tion refers, conforms to the following guidelines and standards. European Standards including relevant amendments EN 61000-3-2:2006 / A1:2009 / A2:2009 (Harmonic currents) EN 61000-3-3:2008 (Flicker) EN 61000-6-2:2005 / AC:2005 (Interference resistance for industrial environments) EN 61000-6-3:2007 / A1:2011 (Interference emission for domestic environments) EN 62109-1: 2010 (safety of power converters Part 1) EN 62109-2: 2011 (safety of power converters Part 2) Directive 2004/108/EC Electromagnetic compatibility Directive 2006/95/EC Electrical Apparatus Low Voltage Directive Application of the CE marking in accordance with Appendix III, Section B:2013 CENTROSOLAR AG 2013-07-01 Dr. Johannes Kneip (Member of the Management Board) Dipl.-Ing. Mirko Held (Head of Product Management) This declaration applies to all identical copies of this product. This declaration loses its validity if the device is modified or incorrectly connected. This declaration certifies compliance with the mentioned regulations but does not ensure the properties. The safety instructions in the product documentation provided must be observed! 2 3

Proper use The Powerstocc DC Storage converts DC current into AC current. The current can be used for the following: nn for consumption nn to store the current in the battery of the system (BS DC Storage 11.6 Pb) nn for feeds into the public mains grid The unit may only be used in grid-connected photovoltaic systems within the permissible power range and under the permissible environmental conditions. The device is not intended for mobile use. Inappropriate use can be hazardous and lead to injury or even death of the user or third parties. Material damage to the device and other equipment can also occur. The inverter may therefore only be used for its intended purpose. The Powerstocc DC Storage is equipped with an energy management system. This system controls based on technical and economic aspects of the use of electricity generated. Exclusion of liability Any use that differs from or goes beyond the stated intended purpose is considered inappropriate. The manufacturer accepts no liability for any damage resulting from this. Modifications to the inverter are prohibited. The inverter may only be used if safe to operate and in technically perfect condition. Any instance of misuse will cause the termination of the warranty, guarantee and general liability of the manufacturer. Only a qualified electrician may open the device. The inverter must be installed by an electrician who is responsible for observing the applicable norms and regulations. Work that could affect the electrical power system of the respective utility company at the site of the solar energy feed-in may only be carried out by qualified electricians expressly authorised (licensed) by the utility company. This includes changes to the factory preset parameters. The installer must always observe the regulations of the utility company. The utility company s specifications must always be observed when setting the parameters. 4 5

Type plate Scope of delivery 1 2 3 8 10 11 13 14 15 16 18 21 CENTROSOLAR AG Stresemannstr. 163 22769 Hamburg Customer Support: +49 (0)831 / 540 214 66 XXXXXXXXXXXXX Art.-Nr.: XXXXXXXX DCinput: UMPP = XXX...XXX V, UMAX = XXX V, IMAX = XXX A ACoutput: XXXXXXXXXX, XXXXX VA (cosφ =1,adj.) max. XX.XA (XX:YYY YW (cosφ =1)) IP 55, -20 C...60 C, OVC DC:II / AC:III DIN V VDE V 0126-1-1:2006-02 VDE-AR-N 4105: 2011-08 NNNNNNNN Ser.-Nr.: XXXXXABCXXXXX HW: YYXXXX Par/PIB: XX.XX FW: XX.XX UI: XX.XX Serviceupdate: XXXXXXXX XXXXXABCXXXXX 4 5 6 7 9 12 17 19 20 1 Name and address of manufacturer 2 Device type 3 Item number 4 MPP control range 5 Maximum input voltage DC 6 Maximum DC input current 7 Number of feed-in phases / Output voltage (nominal) 8 Maximum AC power 9 Maximum output current AC 10 Deviating output with country setting 11 Protection type and ambient temperature range 12 Over voltage category 13 Requirements conforming to those of the built-in grid monitoring 14 Internal Item number 15 Serial number 16 Version of hardware 17 Version of parameter set 18 Version of firmware 19 Version of user interface 20 Date of the last update 21 Removable guarantee label 4x L1 L2 L3 N PE 1x User Manual Safety Notes 6 7

Selecting the installation side NOTE Observe the following instructions, or else warranty claims will be restricted. Protect from rain and water. Select stable installation location. No plasterboard or wooden walls. Protect from direct sunlight. Prevent access by children. Select non-flammable installation location. 200 100 Required cooling space is 200 mm vertical and 100 mm horizontal. Maintain safe distance from flammable materials or areas at risk of explosion. NH3 Protect from dust, contamination and ammonia. 90 Select vertical installation location. Ensure easy access and visible display. C/ F % Ambient temperature must be between -20 C and +60 C. Air humidity must be between 0 % and 95 % (non-condensing). Ensure that people are not disturbed by operating noise. 8 9

To lift the inverter Installation Cooling space 1. 100 45 200 Mounting spaces Lift here! max.10 20 45 100 Lift here! 74 2. 200 3. 10 Powerstocc DC Storage 11

Connecting AC and DC side LebensGEFAHR durch Stromschlag! Опасност за живота поради токов удар. Wechselrichter spannungsfrei schalten. Изключвайте инвертора от напрежението. Risk of death due to electrical shock! Livsfara på grund av elektrisk stöt! De-energise the inverter. Koppla växelriktaren spänningsfri. Danger de mort par électrocution! Zagrożenie życia przez porażenie prądem! Mettre l onduleur hors tension. Odłączyć falownik od zasilania. Peligro de muerte debido a electrocución! Elektrilöögi oht! Desconectar el inversor de la tensión. Lahutage vaheldi vooluvõrgust. Perigo de morte devido a choque elétrico! Pavojus gyvybei dėl elektros srovės smūgio! Desligar a tensão de corrente do inversor. Inverteriui nutraukite įtampos tiekimą. Pericolo di morte per scossa elettrica! Elektriskās strāvas trieciena briesmas! Eliminare la tensione dall inverter. Atslēgt invertoru no strāvas. Livsfare pga. elektrisk stød! Opasnost po život od strujnog udara! Vekselstrømsomformeren skal kobles fra spændingen. Isključiti izmjenjivač. Levensgevaar door elektrische schok! Opasnost po život zbog strujnog udara! Schakel de omvormer spanningsvrij. Isključiti izmjenjivač. Ohrožení života elektrickým proudem! Opasnost po život uslijed strujnog udara! Odpojte střídač od napětí. Izmjenjivač isključite sa naponskog napajanja. Pericol de electrocutare! Opasnost po život usled strujnog udara! Scoateţi ondulorul de sub tensiune. Izmenjivač isključite sa naponskog napajanja. Smrtna nevarnost zaradi električnega udara! Razsmernik odklopite iz električne napetosti. De-energising inverter: Nebezpečenstvo ohrozenia života zásahom 1. OFF ON 2. 3. 4. 5. elektrického prúdu! 5 min Menič prepnite do beznapäťovej prevádzky. OFF Elektrik çarpması nedeniyle hayati tehlike! İnvertörü gerilimsiz hale getirin. Switch off DC side Switch off Safeguard Disconnect Wait 5 minutes Κίνδυνος θανάτου από ηλεκτροπληξία! 1. At Inverter - AC side DC side Αποσυνδέστε τον αντιστροφέα από το ρεύμα. 2. At Batterysystem - S0/AL-out 12 (when connected) - Battery (when connected) 13

Connecting AC and DC side Country-specific installation L1 L2 L3 N PE Connecting AC side Connecting main cable with sealing cap - 1 2 - + + 3 Nm 14 Connecting DC side Second ground connection 15

Option: Connecting DC1 & DC2 in parallel Data transfer Communicationboard II DC1 DC2 DSL or LAN Note When using the parallel connection this feature must be activated under the menue Settings >> Hardware settings >> String 16 connection >> Parallel connection. 17

Analogue modem GSM modem 1. 3. KomBoard2 2. 1. 2. Note 18 Before installing a modem, read the user manual. 19

Commissioning the inverter Selecting the country of use 1. 5 Nm Select Country setting Austria Enter OFF 2. ON 3. ON Note Country setting DE may only be used with inverters installed in PV plants connected to the grid before 31.12.2011. (No displacement 20 factor cosφ preset.) 21

Selecting the country of use Menu overview, DC and AC Country setting 1. Select country DC menu Settings menu AC menu 2. H Enter Battery menu Own consumption menu Austria DC menu DC input 1 (U,I,P) DC input 2 (U,I,P) AC menu Country setting Do you really want to apply this country? No Yes 3. Select YES 4. H Enter Phase 1 (U,I,P) Phase 2 (U,I,P) Phase 3 (U,I,P) Total yield Yield (MWh) Operation time (h) Grid parameters Limitation on (%) Grid frequency (Hz) cos φ Daily yield (diagram) Monthly yield (diagram) Annual yield (diagram) 22 Total yield (diagram) 23

Settings menu Basic settings Language Select language Inverter name Date / time Entering the name Set date / Set time of day Hardware settings String connection Paralell connection Battery settings Battery charge time Start time / End time Communication Network settings 1 Auto IP Network settings 2 IP address / Subnet mask Router settings External router / Router IP RS485 settings Bus termination / Bus bias voltage / RS485 address Portal configuration Portal code / Data export Event messages Immediately mailing On / Off Device information SW/HW version FW / HW / UI / PAR Serial number Serial number Country setting Country setting Certificate Certificate / Certificate index Function test Service menu Fan test Service code Factory settings 24 25

Menu Battery Menu Consumption Battery status 1 Charging status (%) Voltage (V) Charging (A) (Charge/Discharge) Daily own consumption Own consumption (Wh) Own consumptions rate (%) Autonomy degree (%) Battery status 2 Temperature (C ) Charge cycles Total own consumption Own consumption (Wh) Own consumptions rate (%) Autonomy degree (%) Current build. consump Battery (W) Solar generator (W) Grid (W) Phase-sel. Consumption Phase 1 (W) Phase 2 (W) Phase 3 (W) 26 27

Technical data Powerstocc DC Storage Unit Powerstocc DC Storage Unit Input side (DC) Output side (AC) Inverter type Powerstocc DC Storage Max. PV power kwp 11 Recommended PV power kwp 4-11 MPP range with rated DC power V 440-850 Max. input voltage (U dcmax ) V 950 Min. input voltage (U dcmin ) V 180 Rated input current A 11,5 Max. input current (I dcmax ) A 12 Max. input current with parallel connection A 24 Number of DC inputs 2 Number of independent MPP trackers 2 Battery input side (DC) Max. battery input voltage V 314 Min. battery input voltage V 211 Rated voltage battery input V 228 Max. charge current A 12 Max. discharge current A 12 Rated output, cos j = 1 (P ac,r ) kw 10 Max. output apparent power, cos φ, adj kva 10 Rated output current A 14,5 Max. output current (I acmax ) A 14,5 short circuit current (Peak) A 20 Number of feed-in phases 3 Grid connection 3/N/PE, AC, 400 V Rated frequency (f r ) Hz 50 Ext. current sensor (MBS ASRD 14) Rated current primary A 50 Precision method 1 Dimensions (H x W x D) mm 90 x 105 x 54 Max. cable diameter mm 13,5 Mounting on top hat rail to DIN EN 60715 H Efficiencies Max. efficiency % 96,5 Max. European efficiency rate % 95,3 28 29

Powerstocc DC Storage Unit Powerstocc DC Storage Unit System data System data Topology: without galvanic separation - transformerless H Internal protection according to IEC 60529 IP 55 Protection class according to IEC 62103 I Overvoltage category according to IEC 60664-1 Input side (PV-generator) II Overvoltage category according to IEC 60664-1 Output side (grid connection) III Degree of contamination 3 Enviromental category (outdoor installation) Enviromental category (interior installation) UV-resistance Minimum cable cross-section of AC-connect-inline mm² 2,5 Minimum cable cross-section of DC-connect-inline mm² 4 Min. fusing on output side H H H B20, C20 Tightening torque of PE connection, outer Nm 3 Tightening torque of lid screws Nm 5 Operation protection RCCM Typ B 30mA Electronic disconnection device integrated H Height mm 450 Width mm 520 Depth mm 230 Weight kg 33 Max. air throughput m³/h 188 Max. noise emission dba 46 Ambient temperature C -20 60 Max. installation altitude m above sea level 2000 Relative humidity (non-condensing) % 0 95 Connection technology at input side MC 4 H Connection technology at output side spring-loaded terminal strip H Various Warranty Years 5 Warranty extension optional Years 10 / 20 30 31

Service Hotline Sunshine is our business. Germany +49 761 47 74 42 22 and other countries 1 Centrosolar AG is one of the leading providers of solar technology in France Germany. The Hamburg-based company distributes photovoltaic +33 1 6138 4117 modules Belgium, Made Luxembourg in Germany, which are produced in the company s own production Sonnenstromfabrik in Wismar with the highest quality Greece standards The company s product range includes crystalline +30 2310 477 555 high-performance modules, complete systems, modules for Italy +39 011 97 82 420 building integration, inverters and stand alone systems. Centrosolar is Spain a wholly owned subsidiary of the Munich-based Centrosolar +34 961 824 927 Group Portugal AG, 2 an international company with over 1,000 employees and annual sales of EUR 300 million (2011). 07/2013 edition, subject to technical changes and printing errors. 1 Language: German, English 2 Language: Spanish, English Centrosolar AG State-of-the-art inverters for every situation www.centrosolar.com