VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Similar documents
VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

MODEL 422 Submersible Pump Controller

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2



R & D SPECIALTIES ROTROL I USER'S MANUAL

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

DEEP SEA ELECTRONICS PLC

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

System Programming Instructions

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

Installation and Operating Instructions. Solar System Controller ISC3030

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

DEEP SEA ELECTRONICS PLC

Temperature Controllers

OPTI-Solar SC MPPT Series

SBC / 2140 / Stage Battery Charger User Manual

LS0512 Solar Charge Controller

User Manual 1KVA-5KVA INVERTER / CHARGER

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

LS0512R Solar Light Controller

HPP1 MK5 Owner s Manual

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Step 1: Parts List and Bike Preparation

Phoenix Inverter

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DKG-114 MANUAL AND REMOTE START UNIT

Timer Relays - Fixed & Adjustable

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Flight Systems. Replacement for KASSEC DESCRIPTION

User Manual Solar Charge Controller 3KW

Model 1900, 1901, 1902 Switching DC Power Supply

Solar Hybrid Inverter SP Brilliant Series

User s Manual. Automatic Switch-Mode Battery Charger

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

Installation Instructions

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

J1 Plug Pin Identification

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Low Frequency Inverter. User Manual

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

The Traveler Series: Wanderer

HPP1 MK5 Owner s Manual

Model 1900, 1901, 1902 Switching DC Power Supply

PowerOhm Installation Manual for BM R Series Braking Modules

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

PV Charge Controller SBC-7108 / 7112 / 7120

Temperature Controllers

Solar Hybrid Inverter SP Brilliant Grid Series

CX-SERIES ADVANCED BATTERY CHARGER

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

Model H30 Operation Manual

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

Documentation. RM-BV4 Micro DP. Filter control

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

Step 1: Parts List and Bike Preparation

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

User Manual 1.5KVA-3KVA INVERTER / CHARGER

INSTALLATION GUIDE. FCC ID NOTICE

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

Pure sine wave charger inverter Product Manual

The Traveler Series: Wanderer

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

DEEP SEA ELECTRONICS PLC

HX6038 HX

Section 3 Technical Information

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

An ISO 9001:2008 Registered Company

Transcription:

1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This unit can also be set up and used as a Two Stage Battery Charger. Output voltage and current are displayed in turn or selectively by the LED display. 8 fault codes can be displayed for different fault diagnosis by the LED display. Intended Applications * Ideal for voltage sensitive loads, devices and equipment that are distant from the DC source. * Remote Automatic or Manual On/ Off Control of the output makes it ideal for various DC power and DC management applications. * Suitable for on-board charging of stand-alone 12V Battery Bank or a Battery with load. 2. FEATURES 1. Digitally adjustable output voltage in 0.2 V increments (12V-15V DC) makes this unit ideal to operate voltage sensitive devices. 2. 2 stage Battery Charger mode with 14.3V Bulk and 13.6V Float charge. 3. 3 digit LED display for displaying Voltage, Current, Operation Mode and Protection/ Fault Diagnosis. 4. Remote Control Terminal for Manual or Automatic On/Off control of the output power. 5. Remote Voltage Sensing for optimal and accurate powering of distant load or charging of a battery. 6. Remote alarm terminal (12V, 0.25A) for powering external warning device when input is under 42V. 7. A separate always-on auxiliary output (12V, 0.5A) to power critical electronic devices such as security device or remote On/Off manual switch. 8. Fail-save protection, with 7 self-recoverable and all with fault code on LED display. 9. Thermostatic control cooling fan. 3. CAUTION 1. When an inductive load such as motor or a solenoid is used, a diode (400V, 3Amp) must be installed across the load as shown in (Connection Diagram 1). This will protect the converter from the high voltage spike generated by the load when the supplied current is being switched OFF. 2. When the fuse is blown, repair the problem and then replace the fuse with the same type and rating. 3. Avoid touching the heat sink during operation as it may burn you.

4. PANEL VIEW 1. 3 digit LED. Displays voltage, current, operation and fault code. 2. LED indicates Voltage (V) and Current (A). 3. Battery Icon is on when converter is set at the charger mode. 4. SET button. 5. INPUT, OUTPUT, CONTROL & AUXILARY TERMINALS VIEW Remote Remote Terminal for Automatic / Manual control of Output On-Off 12V 0.5A Always On Auxiliary Output GND Ground terminal NC No connection, a dummy terminal Alarm Alarm for low input voltage by DC +12V and 0.25A to power warning device (LED) S+ S- Voltage Remote Sensing positive and negative terminals,

6. Wiring Diagram 6.1 Connection Diagram 1 Example 1 Example 2 Example 3

6.2 Connection Diagram 2 7. INITIAL SET UP AND CONNECTION 1. Leave the output terminals disconnected. 2. Connect a 48V battery to the input terminals. DOUBLE CHECK FOR CORRECT POLARITY BEFORE CONNECTION. 3. Programming Procedure using the SET button. 4. Press and hold the SET button until shows up and display flashes. 5. Flashing digits indicate unit is in programmable mode. Otherwise repeat step 4 to get to programmable mode again. 6. Each short press will increase the output voltage setting by 0.2V steps-> 15.0V -> CHA (Charger Mode). And then back to 12.0V as shown in the following cycle chart. 6. Stop at the desired Output Voltage or at the if you select to set to battery charger mode. 7. After few seconds, the display will stop flashing to confirm the selected setting. The unit will then operate in new set voltage output or as a battery charger. 8. Now you can connect the output terminals to a 12V device or to a 12V battery. Always double check for correct polarity.

8. REMOTE TERMINAL FOR AUTOMATIC / MANUAL OUTPUT ON-OFF CONTROL 1. The DC-DC Converter can be set to control the output Manually or Automatically. 2. Application of the Remote Control Terminal: A. The converter can be set to manual control of the output via external switch B. The remote On/Off function can be controlled via many types of On/Off switches and with various DC sources between 8V-32V. 3. Once the Remote Terminal has been connected to a positive 8-32V, the converter will be modified to Remote Control Mode and will remain in this mode until it is disabled either by reset, or to factory preset. See section 11 and 12 for more detail information.

9. GENERAL OPERATION LED Display During operation, the LED display will display sequentially Voltage and Amps. A quick press of the SET button will either hold the display (at desired V, A) or return to the default scrolling mode. The display will switch off after 5 minutes to conserve the energy. Display can be restarted by a quick press of the SET button. When the output current is less than 1 Amp or output is open circuited the LED display will show indicating Low Output Amp. This applies to both converter and charger mode. Battery is fully charged when the output float voltage is 13.6V and the current to the battery is less than 1Amp. Remote Voltage Sensing Voltage converter can be finely tuned to supply your device with the required voltage even when your device is at a distance. You can use the remote voltage sensing terminals (S-, S+) to ensure accurate voltage is supplied to the load. Alarm Terminal The Alarm terminal is for input low voltage alert (F05). It provides 12V, 0.25A to power remote LED to give out alarm before the converter falls into low voltage protection mode and shuts down. The alarm signal will turn On when the input is below 42V and will turn Off when the input rises back above 50V.

10. BATTERY CHARGER MODE - TWO STAGE CHARGER When the unit is set in Charger Mode, LED Displays and the charger icon will be lit up to confirm the Charger is in operation. Bulk Charge is set at constant current of 20A and voltage at 14.3V. Float Charge voltage is set at 13.6V. The Charger Icon flashes in Bulk Charge and becomes constant in Float Charge. Quick press the SET button to display charging Voltage and Current. Please note that when the battery is full and the float charge current is less than 1A, the current display shows 11. DISPLAY INDICATION Low Current Display when the output current is less than 1 Amp CHARGER Mode SELECTION (programmable) Mode. Ready for programming of output voltage & charger mode REMOTE CONTROL DISABLED, there is always output when input is powered up FACTORY DEFAULT SETTINGS ENABLED (see section 12 for default settings) Flashing = Bulk Charge, Solid = Float Charge

12. TO ACTIVATE AND DEACTIVATE REMOTE CONTROL MODE The Remote control terminal is disabled by default at the factory and the output is always on. To enable the Remote Control Mode, apply a positive 8 to 32VDC to Remote terminal. After Remote Control Mode has been enabled it will stay enabled until it is disabled or reset to factory default setting in 12. To disable remote control mode - Press and hold SET button until is shown. - Release button then wait for few seconds. The remote control will be disabled and the output will stay always ON. 13. FACTORY DEFAULT SETTINGS 1. Unit is in DC-DC Converter Mode with Output Voltage set at 13.8V 2. Remote Control is disabled and the Output is always ON. You can reset DC-DC Converter to factory default setting by following steps: - Press and hold SET button until is shown. - Release button then wait for few seconds. The converter is reset back to factory default setting. 14. DISPLAY ON/OFF The display will be switched off automatically after 5 minutes. Press the Set Button to restart the display for another 5 minutes. 15. ALWAYS ON AUXILIARY OUTPUT The DC-DC Converter will provide constant 12V, 0.5A to power critical devices such as security or alarm and will supply a positive voltage source for manual remote On/Off control of the output. Upon connection of the input to the 48V battery supply, the 12V terminal will be powered. 16. REMOTE VOLTAGE SENSING PORTS The remote voltage sensing operates for both Converter mode and Charger mode. It compensates for voltage drop at a distant load or auxiliary battery. It further enhances the stability of the output voltage to the distant connected load or battery. Connect the cable from the Positive S+ to Positive of load / battery and Negative S- to Negative of load/ battery. 17. ALARM -- The low input voltage pre-warning The alarm signal port provides 12V 0.25A for external LED or other alarm device to give pre-warning signal when input voltage drops below 42V before further dropping to 38V at which the output shuts down. 18. LOW CURRENT DISPLAY The display will show when the output current is less than 1Amp. The converter can be in converter or charger mode or when the output is open circuit. When in Battery Charger mode, it will mean that the battery is charged.

19. Troubleshooting If no display comes up after connection to the input, check for correct input polarity. Disconnect all cables to the unit and check the input fuse. The LED will display an error code when the converter is in any protection mode. The following table denotes the 8 Error Codes. Error Code F01 F02 Description Over Temperature Protection (Self-restart) When unit s internal temperature becomes higher than the threshold value, unit shuts down the output. Unit will resume normal operation automatically once the temperature becomes normal. Output Over Voltage Protection (Self-restart) In DC-DC Converter Mode, output shuts down when the output voltage is 15% higher than the preset voltage level. Unit will self-restart when the output voltage falls 1V below the preset level. F03 F04 F05 F06 F07 F08 In the Bulk Charge Stage of Charger Mode, the unit shuts down >16V and restarts when the voltage <15.5V. In Float Charge Stage it shuts down when voltage >15.1V and restarts at < 14.6V. Over Load Protection (Self-restart) When the Output current is 2 Amp higher than 20A, the unit will shut down the output. The unit will self-restart once the output current falls back to unit s rated value. Fan Fault (Self-restart) When the fan does not operate normally, the unit will shut down the output. Unit will resume normal operation once the fan fault condition has been removed. Input Low Voltage Protection (Self-restart) Input V < 42V Input V > 50V 35V < Input V < 38V for 3 min. Alarm signal On Alarm signal Off Output shuts down; self-restart > 50V Input V < 35V Output instant shut down; self-restart >50V Output Short Circuit Protection (Self-restart) Unit shuts down output when the output is short circuited. It will self-restart when the fault condition is removed. Output battery terminal reverse polarity protection Fuse will be blown when the output is reverse polarity connected to the battery. Replace the fuse with correct type and rating. Input over voltage protection (Self-restart) Output shuts down when the input voltage is higher than 64V. It will self-restart when the input drops below 61V.

20. SPECIFICATIONS Models Input Voltage Range Output Voltage Range Continuous Output Current No load current VC-4820 38-60VDC 12 15VDC (0.2V increments) 20A < 60mA Efficiency 90% Protections Aux. Output (Always On) 12V / 0.5A Over Voltage, Overload, Input Reverse Polarity, Over Temperature, Output Reverse Polarity, Output Short Circuit, Input Under Voltage Two Stage Battery Charger Bulk Charge 14.3V Max. Constant Current 20A, Float Charge 13.6V Remote Control of Output ON/OFF Yes Automatic or Manual Control Remote Voltage Sense External Alarm Output 13.5V, 0.25A Indicators Cooling System Operating Temperature Approvals Accessory Dimensions (W x H x D) Yes To power warning device when the input is under voltage before the shutdown. 3 digits LED display for V, A & Error code and Battery Charger Indicator Thermostatic Control Fan -10 C to +50 C EN 55014, EN60335.2.29 Supplied four cable lug connectors and one 400V 3A diode 130x55x190 mm Weight Recommended Battery Capacity Range 1.4kg 66AH to 200AH REV.1 2016/10/19 7673-5420-3520