Laboratory Room Controller

Similar documents
BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Laboratory Exhaust Air Terminal

APOGEE Laboratory Room Controller Owner s Manual Rev. 2, 6/00

Laboratory Room Single Duct Supply Air Terminal

Laboratory Exhaust Air Terminal

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Powers TM Controls SW 141 Differential Static Airflow Switches

Acid Resistant AVC6000

TEC Controller Constant Volume - Electronic Output. Owner's Manual Building Technologies

LCM-OAVS Room Pressurization with Slowacting Damper Actuation (One Exhaust, One Supply) and Hot Water Reheat Owner s Manual

LCM-OAVS Room Pressurization Controller with Fast-acting Damper Actuation (One Exhaust, One Supply) and Hot Water Reheat Owner s Manual

Powers TM Controls EA 338 Electronic Actuator

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

Operations Manual OM

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

BACnet PTEC Controller VAV Chilled Beam with Demand Control Ventilation (CO2) and Floating or Analog Output Owner s Manual

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

BACnet Fume Hood Controller Vertical Sash with Damper or Venturi Air Valve and 2-Position Constant Volume with Damper.

Dual Duct Variable Air Volume Terminal (Model TDS)

LCM-OAVS Room Pressurization with Slowacting Venturi Air Valves (One Exhaust, One Supply) and Hot Water Reheat Owner s Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Laboratory Solutions. pricecriticalcontrols.com

Powers TM Controls RL 243 SW Switching Relay

Laboratory Room Single Duct Supply Air Terminal

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Description. functions including single duct pressure dependent or pressure independent systems.

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

VE VVG Series Electronic Two-way Valves Normally Closed

Air Flow Measurement Technologies

SLIM LINE FUME HOOD MONITOR

STR Circular VAV Terminal Units

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

BACnet PTEC Controller Dual Duct Two Air Velocity Sensors. Owner's Manual Building Technologies

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

Operations Manual OM BACnet VAV Actuator. Group: Applied Air Systems Part Number: OM 1063 Date: February 2015

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: University of Houston Project Name

Healthcare Solutions Room Pressure Monitors and Controls

HVAC Products. Introducing the SED2 Variable Frequency Drives

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Low Pressure Sensor. Overview. Specifications. Installation and Operation

SAX Electronic Valve Actuator

Differential pressure switch for monitoring air pressure in HVAC systems.

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

Precision-I Laboratory System Universal Digital Monitor

EZvav Digital Controls

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Acid Resistant AVT6000

Air Quality Solutions

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

SAV Electronic Valve Actuator

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators


YCCS Zone/Bypass Damper Assembly

7 Services Control and monitoring

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

ACCESSORIES & OPTIONS FOR VENTURI AND VENTURI FX VALVES

Metasys Zoning Package

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

YCCS Zone/Bypass Damper Assembly

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

COMPLETE and FULLY INTEGRATED AIR PRESSURE CONTROL & MONITORING SYSTEMS

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

OE326-23I-OR VAV/Zone Controller

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

Powers Controls TT 184 Temperature Transmitters

Venturi Valve. 2 For more information visit v100. Actuator. Potentiometer. Lever Arm. Airflow Area AIRFLOW.

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Model Q45H/ Residual Chlorine Monitor...

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Metasys Zoning Package Installation

Fume Hood Controller Application 2941 and 2942: Vertical Sash Configuration with Damper or Venturi Air Valve. Start-up Procedures

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

LOW PRESSURE CELERIS CONTROLLERS

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

1291BL Series Technical Specification Single Axis Position and Rate Table System

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

CCS Zone/Bypass Damper Assembly

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Powers Controls No. 6 Pneumatic Damper Actuator

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

FEATURES AND BENEFITS

Variable Air Volume (VAV) Pressure Independent Control

RDG160TU Commercial Thermostat

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

CH5000 Heat Recovery Ventilator

PIM Pressure Independence Module

Transcription:

Technical Specification Sheet Rev. 5, April, 2001 Laboratory Room Controller Description The APOGEE Automation System Laboratory Room Controller (LRC) provides Direct Control (DDC) for laboratory space pressurization and temperature control. The controller maintains the user defined differential airflow between the room air supply and Fume Hood Controller exhaust and general exhaust terminals by measuring the airflow and controlling the damper position of the supply and general exhaust terminals. Temperature control is provided by measuring the room temperature and controlling the position of the reheat valve and adjusting the airflow. Figure 1. Laboratory Room Controller - Pneumatic Actuation. The LRC operates as an independent, stand-alone DDC controller and can be connected on the Floor Level Network (FLN) with the APOGEE Automation System. This extends the benefits of DDC to all of the building s HVAC equipment. This approach to lab room control includes the following features. Features Figure 2. Laboratory Room Controller Electronic Actuation. Closed loop PID control of HVAC systems to maintain tighter air volume and temperature control Control sequences for both single duct and dual duct supply system applications Supports the use of wall switch input to change from occupied to unoccupied mode for increased energy savings Optional room pressurization alarm output to notify laboratory occupants, Reports airflow directly in actual cfm (lps) On-line, convenient HVAC diagnostics through communication with a Portable Operator s Terminal at the room sensor or any field panel Document No. 149-318P25 Page 1 of 5

Set points and control parameters easily assigned and changed using the Portable Operator s Terminal Electrically Erasable Programmable Read Only Memory (EEPROM) used for storing set points and control parameters no battery backup or reentry of data required Quick return from power failure without operator intervention Maintains room pressurization during transient conditions, i.e., rapid hood sash movement Two controller options, both use the same air flow measurement technology while offering options for control of end devices Pneumatic Output for control of pneumatic valve and damper actuators Electronic Output for control of 0-10V hot water valves and the Laboratory Electronic Damper Actuators Laboratory Room Controller Pneumatic Actuation The Laboratory Room Controller-Pneumatic Actuation consists of the Laboratory Control Module, two lab pneumatic transducers for pressure control, one AO-P Transducer for temperature control, two auto-zero modules for airflow measurement accuracy and an enclosure. All assemblies are pre-mounted and preterminated (electric and pneumatic connections) within the enclosure at the factory. External connections for the pneumatic damper actuators and flow sensors are located on the side of the enclosure. The LRC can be factory mounted to the Laboratory Room Supply Terminal or field mounted within the lab room. The control algorithm is pre-programmed and controllers are ready to operate after selecting the application and assigning the controller s address using the. If desired, the operator may use the to adjust the air velocity set points in flow, differential flow, room temperature set point and other set points. Laboratory Controller Module- Pneumatic The Laboratory Controller Module includes a microprocessor-based assembly with on-board differential pressure transducers for airflow measurement. Wiring termination for input and output points, FLN communications, and power are provided via removable terminal block connections. The room temperature sensor is connected to an on board RJ-11 jack. The controller connects to the following external devices: Fume Hood Controller Fume Hood Flow Module Pneumatic Damper Actuators Pneumatic Hot Water Valve Room Temperature Sensor Portable Operators Terminal APOGEE Automation System Input Devices (e.g., wall switches) Output Devices (e.g., alarm horn) Laboratory Room Air Terminals boxes Controller Specifications Power Requirements Operating Range Power Consumption: Inputs Room Temperature Supply Airflow Exhaust or 2 nd supply airflow Fume Hood Exhaust Flow Occupied Switch 1 DI Alarm Switch 1 DI Note: All Input (DI) points are dry contact. Outputs Auto-zero Pressure Alarm Room Occupied Status General Exhaust Airflow Control Spare 19 to 28 VAC 50 or 60 Hz 12 VA (Nominal) to 24 VA (Peak) @ 24 VAC (plus loads) 1 temperature sensor 1 (0 10) Vdc flow signal 2 DOs to pneumatic 2 DOs to pneumatic Note: All Output (DO) points are 24 VAC optically isolated solid state switches @ 0.5A. Temperature Control Enclosure 1 pneumatic output 13.5 W x 14.5 L x 4 D (320 mm x 340 mm x 102 mm) Approx. 10 lbs (4 kg) Page 2 of 5

Control Performance Controlled Temperature Flow Control Speed of Response Environmental Conditions Storage Temperature Operating Temperature Humidity Range Agency Listings FCC UL Communications Remote Local ±1.0 F (0.6 C) Accuracy, Heating or Cooling 1.5 sec. -40 F to 167 F (-40 C to 75 C) 32 F to 104 F (0 C to 40 C) 10 to 95% (non-condensing) Class B, subpart J 916 PA ZX 864-UDTZ FLN Trunk Figure 4. AO-P Transducer. AO-P Transducer The AO-P Transducer (Figure 4) contains the devices that provide the signal conversion from electronic to pneumatic. One transducer is used within the LRC to interface to a pneumatic valve actuator for room temperature control. Specifications Maximum Input Pressure Air Consumption Power Consumption Figure 3. Laboratory Pneumatic Output Module. 30 psi 8 SCIM (ml/sec) 1.0 VA @ 24 VAC max 7-1/4"W x 4-1/4"H x 3-1/16"D (184 mm x 108 mm x 78 mm) 0.5 lb. (0.2 kg) Laboratory Room Controller Electronic Actuation Laboratory Pneumatic Output Module The Laboratory Pneumatic Output Module (Figure 3) contains the transducers that provide the signal conversion from electronic to pneumatic. Two modules are used within the Laboratory Room Controller to interface to pneumatic dampers for room airflow control. The Laboratory Room Controller-Electronic Actuation consists of the Laboratory Control Module, two autozero modules for airflow measurement accuracy and an enclosure. All assemblies are pre-mounted and preterminated within the enclosure at the factory. External connections for flow sensors are located on the side of the enclosure. The LRC can be factory mounted to the Laboratory Room Supply Terminal or field mounted within the lab room. Specifications Maximum Input Pressure Air Consumption Power Consumption 30 psi 38 SCIM (ml/sec) 5 VA @ 24 VAC max. 2-1/2"W x 4-1/2"H x 1-1/4"D (64 mm x 114 mm x 32 mm) 0.5 lb. (0.2 kg) The control algorithm is pre-programmed and controllers are ready to operate after selecting the application and assigning the controller s address using the. If desired, the operator may use the to adjust the air velocity set points in CFM, differential flow, room temperature set point and other set points. Page 3 of 5

Laboratory Controller Module- Electronic The Laboratory Controller Module includes a microprocessor-based assembly with on-board differential pressure transducers for airflow measurement. Wiring termination for input and output points, FLN communications, and power are provided via removable terminal block connections. The room temperature sensor is connected to an on board RJ-11 jack. The controller connects to the following external devices: Fume Hood Controller Fume Hood Flow Module Lab Electronic Damper Actuator Assemblies Electronic Hot Water Valve Room Temperature Sensor Portable Operators Terminal APOGEE Automation System Input Devices (e.g., wall switches) Output Devices (e.g., alarm horn) Laboratory Room Air Terminals boxes Controller Specifications Power Requirements Operating Range Power Consumption: Inputs Room Temperature Supply Airflow Exhaust or 2 nd supply Airflow Fume Hood Exhaust Flow Occupied Switch Alarm Switch 19 to 28 VAC 50 or 60 Hz 3.9 VA (Nominal) to 5.3 VA (Peak) @ 24 VAC (plus loads) 1 temperature sensor 1 (0-10) Vdc flow signal 1 DI 1 DI Outputs Auto-zero Pressure Alarm Room Occupied Status General Exhaust or 2 nd Spare 1 floating 2 DOs 1 floating 2 DOs Note: All Output (DO) points are 24 VAC optically isolated solid state switch @ 0.5A. Temperature Control Enclosure Control Performance Controlled Temperature Flow Control Speed of Response Environmental Conditions Storage Temperature Operating Temperature Humidity Range Agency Listings FCC UL Communications Remote Local 0-10V 13.5"W x 14.5"L x 4"D (320 mm x 340 mm x 102 mm) Approx. 10 lbs (4 kg) ±1.0 F (0.6 C) Accuracy, Heating or Cooling 1.5 sec. -40 F to 167 F (-40 C to 75 C) 32 F to 104 F (0 C to 40 C) 10 to 95% (non-condensing) Class B, subpart J 916 PA ZX 864-UDTZ FLN Trunk Laboratory Room Controller Flow Measurement Laboratory Room Controller airflow measurement consists of the controller module A/D conversion circuitry, on-board differential pressure transducers (2) and auto-zero modules (2). Air velocity sensors (within the air terminal) send the velocity signal to the LRC differential pressure transmitter. Auto-zero modules are connected to the air velocity pressure transducer's inlet ports to enable automatic periodic re-calibration. This re-calibration ensures accurate, drift-free and stable airflow measurement. Automatic re-calibration of the differential pressure transducers occurs upon system power-up and when airflows are stable. Page 4 of 5

Air Flow Measurement Specifications Ordering Information Range 0 to 2.0" wc Accuracy @ low flow (0.008" wc to 0.01" wc) ±3.5% Accuracy @ high flow (0.01" wc to 2.0" wc) ±2.0% Maximum distance of the LRC from the air 50ft (12.2m) velocity sensor Lab Room Controller Communication Up to 32 LRCs or other Terminal Equipment Controllers can be connected to each of a field panel s 3 FLN trunks for a total of 96 per field panel. Communication with the LRC can be initiated from any APOGEE Automation System field panel on the system network. The APOGEE Automation System network does not require additional hardware to connect Terminal Equipment Controllers. When Terminal Equipment Controllers are wired to a field panel, features such as energy management programs, alarm reporting, centralized control, modification of the system database, system-wide troubleshooting and the global commanding of devices are available to them. The computer serving as the Portable Operator s Terminal can communicate with LRCs or any field panel. The terminal connects to the controller via a plug-in jack on either the controller, the room temperature sensor associated with the LRC, or a field panel. The terminal can be used to remotely adjust air volume settings or temperature set points, to troubleshoot, and to start up the system. When connected to the RS-232 port of a field panel, the terminal provides system-wide communication. The terminal uses full English language for all functions, eliminating the need to remember coded commands. Description Laboratory Room Controller- Pneumatic Actuation Laboratory Room Controller- Electronic Actuation Part Number 546-00360 546-00362 Fume Hood Flow Module 546-00351 Single Duct Supply Terminal Dual Duct Supply Terminal Exhaust Terminal Air Flow Measurement Station LGSn.n LGDn.n LGEn.n LGFn.n #3 Pneumatic Actuator 546-00020 Laboratory Electronic Damper Actuator Assembly (floating control) 546-00439 FHET Spec Sheet 149-278P25 VAV FHC Spec Sheet 149-245P25 Laboratory Room Single Duct Supply Air Terminal Spec Sheet Laboratory Room General Exhaust Air Terminal Spec Sheet Laboratory Room Dual Duct Supply Air Terminal Spec Sheet Laboratory Room Air Flow Measurement Station Spec Sheet Fume Hood Flow Module Spec Sheet 149-319P25 149-320P25 149-338P25 149-317P25 149-339P25 Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. APOGEE is a trademark of 2001 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 Printed in the U.S.A. (origin) Page 5 of 5