Standby Amper VOLTAGE

Similar documents
Standby Amper VOLTAGE

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Standby Amper VOLTAGE

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

MITSUBISHI STAMFORD P CM control system. This generator set is manufactured in facilities certified to ISO 9001.

16 KW / 20 KVA POWERED by

640 KW / 800 KVA POWERED by

APD-ULJ250. Standby Power

1000 KW / 1250 KVA POWERED by

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

80 KW / 100 KVA POWERED by

1800 KW / 2250 KVA POWERED by

700 KVA / 550 KW POWERED by

55 KW / 70 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

28 KW / 28 KVA POWERED by

2000 KW / 2500 KVA POWERED by

APD-NG400. NG Standby Power

30 KW / 40 KVA POWERED by

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

45 KW / 55 KVA POWERED by

130 KW / 165 KVA POWERED by

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

18 KW / 18 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

600 KW / 750 KVA POWERED by

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

Rental Power 4BTAA3.3 series engine

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

Diesel Generator Set S3.8 Series Engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

Rental Power Kubota V2403 series engine

204 KW / 254 KVA POWERED by

64 KW / 80 KVA POWERED by

500 KW / 625 KVA POWERED by

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

130 KW / 165 KVA POWERED by

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Rental Power QSB7 series engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Rental Power QSL9 series engine

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

Technical specification

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set QSX15 series engine

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

300 KW / 375 KVA POWERED by

Model NA 2 L

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Rating Definitions and Conditions

Model MP150 W W

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

GP-C30-D6. CUMMINS 4B3.9G2 Diesel Engine STAMFORD CUMMINS PI144F Alternator DEEPSEA DSE7320 Controller

57 KW / 71 KVA POWERED by

70 KW / 90 KVA POWERED by

GP-J200-60T4F. JOHN DEERE 6068HFG Engine US EPA Tier 4 FINAL LEROY SOMER TAL-046-C Alternator DEEPSEA DSE7320 Controller

Rating Definitions and Conditions

Rating Definitions and Conditions

Rating Definitions and Conditions

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

Transcription:

INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested. Power (kva) 3 Phase,50 Hz, PF 0.8 STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper VOLTAGE 400/231 kw kva kw kva 400,00 500,00 364,00 455,00 721,71 STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed. PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046. General Characteristics Model Name AC 500 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS QSX15-G6 Alternator Made and Model ECO 40-3S/4 B Control Panel Model 7320 Canopy MS 80 ENGINE SPECIFICATIONS Engine CUMMINS Engine Model QSX15-G6 Number of Cylinder (L) 6 cylinders - in line Bore (mm.) 137 Stroke (mm.) 169 Displacement (lt.) 15 Aspiration Turbo Charged and After Cooled Compression Ratio 17.0:1 RPM (d/dk) 1500

Oil Capacity (Total With Filter) (lt) 91 STANDBY POWER 459/615 Prime Power 414/555 Block Heater QTY 1 Block Heater Power (Watt) 3000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Cummins HPI-TP Governor System ECM Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2x120 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 637 Coolant Capacity (engine only / with radiator) (lt) 24/66 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 95.9 Fuel Cons. Prime With %75 Load (lt/hr) 74.3 Fuel Cons. Prime With %50 Load (lt/hr) 51.3 ALTERNATOR CHARACTERISTICS Manufacturer Mecc Alte Alternator Made and Model ECO 40-3S/4 B Frequency (Hz) 50 Power (kva) 500 VOLTAGE (V) 400 Phase 3 A.V.R. DER1 Voltage Regulation (+/-)1% Insulation System H Protection IP23 Rated Power Factor 0.8 WEIGHT WOUND ROTOR (Kg) 274.6 COOLING AIR (m³/min) 54 Open Gen.Set Dimensions (mm) LENGHT 3380 WIDTH 1550 HEIGHT 2100 DRY WEIGHT (kg.) 3815 TANK CAPACITY (lt.) 850 Gen.Set Canopy Dimensions (mm)

LENGHT 4810 WIDTH 1610 HEIGHT 2620 DRY WEIGHT (kg.) 4815 TANK CAPACITY (lt.) 850 1. Steel structures. 2. Emergency stop push button. 3. Control panel is mounted on the baseframe. Located at the right side of the generator set. 4. Corrosion-resistant locks and hinges. 5. Oil could be drained via valve and a hose 6. Exhaust system in the canopy. 7. Special large access doors for easy maintanance 8. In front and back side special large access doors for easy maintanance 9. Base frame -fuel tank. 10. Lifting points similar to ISO container, located on each top corner of the canopy. 11. The cap on the canopy provides easy accsess to radiator cap. 12. Sound proofing materials 13. Plastic air intake pockets. INTRODUCTION Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability. Control Panel Control Module DSE Control Module Model 7320 Communication Ports MODBUS 1. Menu navigation buttons 2. Close mains button 3. Main Status and instrumentation display 4. Alarm LED's 5. Close generator button 6. Status LED's 7. Operation selecting buttons Devices DSE, model 7320 Auto Mains Failure control module Static battery charger Emergency stop push button and fuses for control circuits CONSTRUCTION and FINISH Comonents installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface Polyester composite powder topcoat forms high gloss and extremely durable finish Lockable hinged panel door provides for easy component access

INSTALLATION Control panel is mounted generating set baseframe on robust steel stand or power module. Located at side of generating set with properly panel visibility. GENERATING SET CONTROL UNIT The DSE 7320 conrol module is a standard addition to our generator sets from 220 kva upwards and it has been designed to start and stop diesel andgas generating sets that include electronic and non electronic engines. The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable for controlling a standby generating set in conjunction with an automatic transfer switch. The DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and indicating faults by means of its LCD display on the front panel. STANDARD SPECIFICATIONS Microprocessor controlled - 132 x 64 pixel LCD display makes information easy to read - Front panel programming and also via PC software - Soft touch membrane keypad and five key menu navigation - Remote communications via RS232, RS485 and ethernet and SMS messaging - Event logging (50) showing date and time - Multiple date and time engine exercise mode and maintenance scheduler - Engine block heater control. - Controls; stop, manuel, auto, test, start, mute lamb test/transfer to generator, transfer to mains, menu navigation. Instruments ENGINE Engine speed Oil pressure Coolant temperature Run time Battery volts Engine maintenance due GENERATOR Voltage (L-L, L-N) Current (L1-L2-L3) Frequency Earth current kw Pf kvar kwh, kvah, kvarh Phase sequence MAINS Voltage (L-L, L-N) Frequency

WARNING Charge failure Battery under voltage Fail to stop Low fuel level (opt.) kw over load Negative phase sequence Loss of speed signal PRE-ALARMS Low oil pressure High engine temperature Low engine temperature Over /Under speed Under/over generator frequency Under/over generator voltage ECU warning SHUT DOWNS Fail to start Emergency stop Low oil pressure High engine temperature Low coolant level Over /Under speed Under/over generator frequency Under/over generator voltage Oil pressure sensor open Phase rotation ELECTRICAL TRIP Earth fault kw over load Generator over current Negative phase sequence Options High oil temperature shut down Low fuel level shut down Low fuel level alarm High fuel level alarm EXPANSION MODULES

Editional LED module (2548) Expension relay module (2157) Expansion input module (2130) Standards Elecrical Safety / EMC compatibility BS EN 60950 Electrical business equipment BS EN 61000-6-2 EMC immunity standard BS EN 61000-6-4 EMC emission standard STATIC BATTERY CHARGER Battery charger is manufactured with switching-mode and SMD technology and it has high efficincy. Battery charger models' output V-I characteristic is very close to square 2405 has fully output shot circuit protection and ıt can be used as a current source. 2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives. The charger is fitted with a protection diode across the output. Charge fail output is available. Connect charge fail relay coil between positive output and CF output. Input: 196-264V. Output: 27,6V 5A or 13,8V 5A. STANDARD SPECIFICATIONS - Water cooled, Diesel engine - Radiator with mechanical fan - Protective grille for rotating and hot parts - Electric starter and charge alternator - Starting battery (with lead acid) including rack and cables - Engine coolant heater - Base frame design incorporates an integral fuel tank and anti-vibration isolators - Flexible fuel connection hoses - Single bearing, class H alternator - Industrial exhaust silencer and steel bellows supplied separately(for open sets) - Static battery charger - Manual for application and installation - Generators Sets voltage and frequency regulation comply with ISO 8528-5 - Generators Sets can take 100% load at one step according to NFPA110 OPTIONAL EQUIPMENTS ENGINE Fuel-Water Seperator Filter Oil heater ALTERNATOR

Anti-Condensation Heater Over sized alternator Main line circuit breaker CONTROL SYSTEM Automatic synchronising and power control system ( multi gen-set Parallel ) Remote annunciator panel Alarm output relays Remote communication with modem Earth fault, single set Charge Ammeter TRANSFER SWITCH Three or four pole contactor Three or four pole motor operated circuit breaker OTHER ACCESSORIES Main Fuel Tank Automatic or manual fuel filling system Electrical oil drain pump Low and high fuel level alarm Residential silencer Enclosure: weater protective or sound attenuated Duct adapter ( on radiator) Inlet and outlet motorised louvers Inlet and outlet acoustic baffles Trailer Tool kit for maintenance 1500/3000 hours maintenance kit Double wall chassis Supplied with oil and coolant - 30 C Battery isolating switch AKSA CERTIFICATES - TS ISO 8528 - CE - SZUTEST - 2000/14/EC