V2000Kx KV type TRV Body

Similar documents
V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE

Valencia Radiator Valve Range

4-way Distribution Valve

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet

High capacity valve body, type RA-G

Mikrotherm F. Manual Radiator Valves With presetting

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

V5049A FLANGED LINEAR VALVE PN25/40

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

RTL. Floor Heating Controller Return temperature limiter with and without presetting

Regutec F. Return Lockshield Radiator lockshield

High Capacity Valve Body, Type RA-G

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Automatic balancing valves ASV-PV DN (3rd gen.)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN40 TO DN50)

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

V5822A/5823A,C/V5832A/V5833A,C

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Technical information Thermostatic radiator valves

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

V5832A/5833A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

2-Port and 3-Port Zone Valves PN 16

Valve bodies type RA-N with integrated presetting

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

Floor heating manifold with automatic flow control

V5822A / 5823A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS GENERAL

Fan-coil valves Series

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

2-Port and 3-Port Zone Valves PN 16

3-Port Seat Valves with Male Thread, PN 16

3-Port Seat Valves with Male Thread, PN 16

Flow-compensated temperature controller AVTQ DN 15

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Two-port seat valves with male thread, PN16

Series V47 Temperature Actuated Modulating Valves

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Thermostatic radiator valves with presetting

CV-SFS4-PN16 SERIES SLIENT CHECK VALVE, GLOBE TYPE FEATURES SPECIFICATIONS PRODUCT IDENTIFICATION SYSTEM PRODUCT DATA

2-port and 3-port terminal unit valves PN16

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

3-port seat valves, external thread, PN16

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Flow controller (PN 25) AVQ - return and flow mounting

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

SOLUTIONS GUIDE. For total efficiency

Flow controller (PN 25) AVQ - return and flow mounting

Ascotherm eco KRP91 Natural convection

Self-operated Temperature Regulators Temperature Regulator Type 1u

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

Globe valves Shut-off check valve 200 AE/BE PN DN Globe valves Lift check valve 240 MT PN DN 10-50

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Manual Presetting Valves LENO MSV-B

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

THERMOSTATIC CONTROL HEADS:

Leakage rate. Valve body. U.S. Registered Trademark EN0B-0308GE51 R1002 Copyright 2002 Honeywell Inc. All rights reserved

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

ML6420A/ML6425A,B. Electric Linear Valve Actuators

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

Pressure relief controller AVA (PN 25)

ACVATIX MiniCombiValves (MCV)

Typetested versions With Type 3213 Globe Valve, unbalanced. With Type 3214 Globe Valve, balanced

M4410C/L SMALL LINEAR THERMOELECTRIC ACTUATORS

Your Personal Catalog Temperature Controllers All our know-how - is now yours

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

2018 High Performance Check Valves for liquid and gaseous media

BUTTERFLY VALVE - N1234 SERIES Pneumatic actuator - Actreg

Modulating control valve PN16 with magnetic actuator

three-way mixing valve

Modulating control valve PN16 with magnetic actuator

MT4-024/MT4-230 MT8-024/MT8-230

950x. Description. Part List

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

STRÖMAX-MFS Circuit Control Valve with Measuring Valves Inclined Model

Transcription:

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA Angle to DIN Straight to DIN 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply or return of radiators or heat exchangers. Together with a radiator thermostat, for example the Thera-4, they control the room temperature by regulating the flow of hot water into the radiator or heat exchanger. The temperature of different rooms is controlled individually and energy is saved. TRV bodies of this type have quiet operation and are fitted to the supply of radiators on two-pipe systems with low, medium or high flow rates. The valve insert can be replaced while the system is running and without draining using the service tool (see Accessories ). TRV bodies of this type are suitable for Honeywell radiator thermostats with M30 x 1.5 connection Certain Honeywell MT4 actuators Honeywell Hometronic HR80 and Roomtronic HR40 actuators Angle to NF Straight to NF AT-Concept AT-Concept valves share the same valve housing design. The valve insert can be replaced by any other AT-Concept valve insert, i.e. BB, KV, UBG, SL, VS, FS, FV and SC. Horizontal angle Corner angle Straight with swanneck Features With valve disc specially designed for three different k v flow rates For heating systems with low, medium or high flow rates Quiet operation DIN type bodies with dimensions according to EN215, Appendix A, Series D NF type bodies with dimensions according to EN215, Appendix A, Series F AT-Concept valve housing and insert Valve insert can be replaced while system is operating and without draining the system Valve opening spring is not in the water Standard M30 x 1.5 thermostat connection Supplied with red, blue or green protection cap, imprinted for clear identification Honeywell Subject to change EN0H-2102GE25 R1111

V2000KX - KV TYPE TRV BODY Design The thermostatic radiator valve body consists of: Valve housing PN10, DN10, 15 or 20 with internal thread connection to DIN2999 (ISO7) for threaded, copper or precision steel pipe on inlet 1 (compression ring fittings see Accessories ) external thread connection with union-nut and radiator tailpiece on outlet 1 (Eurocone for DN15) angle to DIN and straight to DIN bodies with dimensions according to EN215, Appendix A, Series D angle to NF and straight to NF bodies with dimensions according to EN215, Appendix A, Series F Valve insert with KV type cartridge Protection cap Union-nut and radiator tailpiece Materials Angle/straight to DIN: valve housing made of nickel-plated red bronze Corner angle, horizontal angle and swanneck tailpiece: valve housing made of nickel-plated hot-forged brass Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle Protection cap made of red, blue or green plastic Union-nut and tailpiece made of brass, union-nut nickelplated, tailpiece optionally nickel-plated Please Note: To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035 Additives have to be suitable for EPDM sealings System has to be flushed thoroughly before initial operation with all valves fully open Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell Please contact us if you should have any special requirements or needs Specifications Medium Heating water, water quality to VDI2035 Operating temperature max. 130 C (266 F) Operating pressure PN10 Differential pressure max. 1 bar (14.5 psi) max. 0.2 bar (2.9 psi) recommended for quiet operation k vs(cv)-values 0.14 (0.16) with valve disc 3 (K3) 0.36 (0.42) with valve disc 4 (K4) 0.80 (0.84) with valve disc 5 (K5) Nominal flow K3 30 kg/h K4 76 kg/h K5 190 kg/h Thermostat connection M30 x1.5 Closing dimension 11.5 mm Stroke 2.5 mm Identification Red (K3), blue (K4) or green (K5) protection cap, 3, 4 or 5 embossed on top of cap 3, 4 or 5 imprinted 3x on top of valve insert Function Thermostatic radiator valves enable individual control of room temperature and thus save energy. The TRV body is controlled by the radiator thermostat. Air from the room passing over the sensor of the radiator thermostat causes the sensor to expand when the temperature rises. The sensor acts onto the valve spindle and this causes the TRV body to close. When the temperature falls the sensor contracts and the spring-loaded valve spindle is opened. The TRV opens in proportion to the temperature of the sensor. Only the amount of water required to maintain the room temperature set on the radiator thermostat can flow into the radiator. Honeywell Subject to change 2 EN0H-2102GE25 R1111

Installation Examples Fig. 1. Angle Fig. 2. Straight Fig. 3. Horizontal angle Fig. 4. Corner angle Fig. 5. Straight with swanneck Dimensions and Ordering Information Fig. 6. Angle Fig. 7. Straight 52 h h G l l L H L Fig. 8. Horizontal angle Fig. 9. Corner angle Fig. 10. Straight with swanneck Honeywell Subject to change 3 EN0H-2102GE25 R1111

Body type DN EN215 certified For the supply Angle to EN215 (D) (Fig. 6) Straight to EN215 (D) (Fig. 7) Angle to EN215 (F) (Fig. 6) Straight to EN215 (F) (Fig. 7) Horizontal angle (Fig. 8) Corner angle, radiator connection left (Fig. 9) Corner angle, radiator connection right (Fig. 9) Swanneck (Fig. 10) For the supply or return Angle with external threads (Fig. 6) Straight with external threads (Fig. 8) Corner angle with external threads, radiator connection left (Fig. 9) Corner angle with external threads, radiator connection right (Fig. 9) Table 1. Dimensions and OS-Nos (OS=Ordering System) kvs(cvs)- value Pipe connection l L h H h2 OS-No. K3 10 0,140 (0,164) Rp 3 /8" 26 52 22 20 V2000EK310 K4 0,360 (0,421) V2000EK410 K5 0,800 (0,936) V2000EK510 K3 15 0,140 (0,164) Rp 1 /2" 29 58 26 20 V2000EK315 K4 0,360 (0,421) V2000EK415 K5 0,800 (0,936) V2000EK515 K5 20 0,800 (0,936) Rp 3 /4" 34 66 29 19 V2000EK520 K3 10 0,140 (0,164) Rp 3 /8" 59 85 25 V2000DK310 K4 0,360 (0,421) V2000DK410 K5 0,800 (0,936) V2000DK510 K3 15 0,140 (0,164) Rp 1 /2" 66 95 25 V2000DK315 K4 0,360 (0,421) V2000DK415 K5 0,800 (0,936) V2000DK515 K5 20 0,800 (0,936) Rp 3 /4" 74 106 25 V2000DK520 K4 10 0,360 (0,421) Rp 3 /8" 24 49 20 21 V2020EK410 K5 0,800 (0,936) V2020EK515 K5 0,800 (0,936) V2020DK515 K4 10 0,360 (0,421) Rp 3 /8" 24 50 22 33 V2000AK410 K5 0,800 (0,936) V2000AK510 K4 15 0,360 (0,421) Rp 1 /2" 26 24 26 35 V2000AK415 K5 0,800 (0,936) V2000AK515 K4 10 0,360 (0,421) Rp 3 /8" 24 53 26 22 26.5 V2000LK410 K4 15 0,360 (0,421) Rp 1 /2" 24 53 26 26 30.5 V2000LK415 K4 10 0,360 (0,421) Rp 3 /8" 24 53 26 22 26.5 V2000RK410 K4 15 0,360 (0,421) Rp 1 /2" 24 53 26 26 30.5 V2000RK415 K4 15 0,360 (0,421) Rp 1 /2" 66 108 25 V2000BK415 K5 0,800 (0,936) V2000BK515 K5 15 0,800 (0,936) G 3 /4" A 29 26 20 V2060EK515 K5 15 0,800 (0,936) G 3 /4" A 66 25 V2060DK515 K5 15 0,800 (0,936) G 3 /4" A 24 26 26 30,5 V2060LK515 K5 15 0,800 (0,936) G 3 /4" A 24 26 26 30,5 V2060RK515 NOTE: All dimensions in mm unless stated otherwise. EN0H-2102GE25 R1111 4 Honeywell Subject to change

Accessories Pipe Connections Compression fitting for copper and soft steel pipe Consisting of compression nut and compression ring; for ports with internal thread, 1 pc per pack Valve Size Pipe diameter 3/8" (DN10) 10 mm VA620A1010 3/8" (DN10) 12 mm VA620A1012 " (DN15) 10 mm VA620A1510 " (DN15) 12 mm VA620A1512 " (DN15) 14 mm VA620A1514 " (DN15) 15 mm VA620A1515 " (DN15) 16 mm VA620A1516 3/4" (DN20) 18 mm VA620A2018 3/4" (DN20) 22 mm VA620A2022 NOTE: Support inserts have to be used for copper or soft steel pipe with 1.0 mm wall thickness Compression fitting for copper and soft steel pipe Consisting of compression nut, compression ring and support insert; for ports with internal thread; 2 pcs per pack Valve Size Pipe diameter 3/8" (DN10) 12 mm VA621A1012 " (DN15) 12 mm VA621A1512 " (DN15) 14 mm VA621A1514 " (DN15) 15 mm VA621A1515 " (DN15) 16 mm VA621A1516 " (DN15) 18 mm VA621A1518 3/4" (DN20) 18 mm VA621A2018 NOTE: Support inserts have to be used for copper or soft steel pipe with 1.0 mm wall thickness Compression fitting for multiskin pipe Consisting of compression nut, ring and support insert; for ports with internal thread ; 2 pcs per pack Valve Size Pipe diameter " (DN15) 14 mm VA622B1514 " (DN15) 16 mm VA622B1516 Extended radiator tailpiece, nickel-plated, to be shortened as required 3/8" x 70 mm (for DN10) VA5204B010 thread approx. 50 mm " x 76 mm (for DN15) VA5204B015 thread approx. 65 mm 3/4" x 70 mm (for DN20) VA5204B020 thread approx. 60 mm Valve Accessories Manual handwheel cap Pre-settable, with integrated locking device VA2200D001 Pressure cap for shutting off valves on radiator outlet for valves DN10 (3/8") VA2202A010 for valves DN15 (") VA2202A015 for valves DN20 (3/4") VA2202A020 Sealing ring for pressure cap for valves DN10 (3/8") for valves DN15 (") for valves DN20 (3/4") Service tool to replace valve insert for all sizes Replacement valve insert KV3 type KV4 type KV5 type VA5090A010 VA5090A015 VA5090A020 VA8200A001 VS1200K301 VS1200K401 VS1200K501 Reduction piece 1" pipe > " valve VA6290A260 1 1/4" pipe > " valve VA6290A280 1" pipe > 3/4" valve VA6290A285 1 1/4" pipe > 3/4" valve VA6290A305 Honeywell Subject to change 5 EN0H-2102GE25 R1111

Flow Diagram P-Band 1K 2K 3K k v(cv)-value - valve disc K3 0.047 (0.055) 0.095 (0.111) 0.140 (0.164) kv(cv)-value - valve disc K4 0.120 (0.140) 0.240 (0.281) 0.360 (0.421) kv(cv)-value - valve disc K5 0.300 (0.351) 0.600 (0.702) 0.800 (0.936) NOTE: kv (cv)= 0.7 (0.82) for corner angle versions Design Example Given: Required: Solution: Result: Flow rate 150 kg/h Pressure loss ( p) with a P-band of 2K The required pressure loss for the K5 valve disc is found at the intersection of the flow line with the line for the chosen valve performance P=2K p = 62 mbar = 6 200 Pa Environmental and Combustion Controls Honeywell GmbH Hardhofweg 74821 Mosbach, Germany Phone: +49 (6261) 810 Fax: +49 (6261) 81393 www.honeywell.com EN0H-2102GE25 R1111 November 2011 2011 Honeywell International Inc. Subject to change without notice Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce 16, 1180 Rolle, Switzerland or its Authorized Representative.