Atlas Copco Generators QAS kva 50 Hz dual frequency. For your peace of mind

Similar documents
Atlas Copco Generators

WITHSTANDING THE ELEMENTS

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

People. Passion. Performance. 60Hz Diesel Generators for Construction Applications

LWALR LIQUID COOLED LONG RUNNING GENSETS

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

THE POWER OF CONNECTIVITY QAS generators

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Atlas Copco Portable Air compressors

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Standby Amper VOLTAGE

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SET MTU 4R0113 DS80

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

60 KW / 75 KVA POWERED by

DIESEL GENERATOR SET DG00660D5

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMR - 67P 67P 09/05/2016 GMR - 067P

Standby Amper VOLTAGE

19 KW / 24 KVA POWERED by

Standby Amper VOLTAGE

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand

P V 50HZ #CONN #DPP

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

DIESEL GENERATOR SET MTU 12V1600 DS660

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GE.PK.022/020.SS+0_all

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

POWER WITHOUT COMPROMISE

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

DIESEL GENERATOR SET MTU 10V1600 DS500

GE.VO.360/325.SS+0_all

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Model MP150 W W

Model NA 2 L

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

CGT Stamford UCI 274 E1

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

130 KW / 165 KVA POWERED by

Atlas Copco Portable Air compressors

Rating Definitions and Conditions

P6000s 230V 50Hz #CONN #DPP

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

Technical Data V DIESEL TCM500 (Open) LSA47.2M7 Optioanl: Stamford HCI544D. TCM500C (Silent) Tide TPA354S2. Alternator: Leroy-somer

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

HILIGHT RANGE. Your site. Your light.

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Rating Definitions and Conditions

Rating Definitions and Conditions

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

500 KW / 625 KVA POWERED by

55 KW / 69 KVA POWERED by

57 KW / 71 KVA POWERED by

16 KW / 20 KVA POWERED by

Transcription:

Atlas Copco Generators QAS 14-300 14-300 kva 50 Hz dual frequency For your peace of mind

QAS generators: 1 Supersilenced canopy QAS generators are whisper quiet. The foam lined canopy is exceptionally effective at reducing noise to a level that fully complies with the latest European regulations (OND 2000/14 EC). QAS generators are suitable for use at night in noise sensitive locations, and can be used in all residential areas. 2 Sturdy and weatherproof The generator canopy is extremely robust. As it is directly mounted on a skid base a QAS generator can be sited on any firm and flat surface and needs no special foundations. All major components have flexible mountings to keep transmitted vibration to the absolute minimum. QAS generators are designed to withstand rough on-site handling and are suitable for use in demanding environments. The canopy is zincor treated, with a powder coat paint finish for durability and excellent resistance to corrosion. Atlas Copco equipment looks good for longer, to help retain high residual values. 15 13 14 12 Dependable diesel power QAS generators can be specified with VOLVO, YANMAR or PERKINS diesel engines. These proven power units offer excellent operating economy, exemplary starting and continuous reliable operation, even under the severest conditions. For trouble free operation, all power units are fitted with a high capacity fuel filter/water separator. This protects the fuel injection system from solid and liquid impurities. A two-stage air filter, with inner safety cartridge filter, protects the engine from dust and solid particles, regardless of the operating environment. Reputable alternator MECC-ALTE synchronous brushless type alternators are fitted. These offer minimal wear and can be specified to deliver outputs ranging from 13 to 300 kva. The alternators offer a choice of voltages and can easily cope with different motor starting methods. They respond quickly to any sudden load change and will supply stable and sufficient power at all times. MECC-ALTE alternators are specially manufactured for Atlas Copco using new impregnation technology. They offer maximum reliability and meet stringent quality requirements. They comply with all relevant European standards. Continuous value Optimum operating cost across the lifecycle of the product. Continuous operation The fuel tank capacity is designed to enable the generator to operate for full shifts at maximum load. The engine oil can be removed via an integral drain pump. This is standard on QAS150-300 models.

the obvious choice 4 5 3 6 7 Handling made easy QAS generators are well balanced so the units can be safely lifted by crane. Two forklift slots are incorporated in the base frame. These can be accessed from either side of the generator. 8 Supervision at a glance 10 9 All key operating functions can be supervised without opening the canopy. The comprehensive instrument panel is covered by a tough transparent cover that provides protection from humidity and the environment. 11 If the generator is automatically shut down in an emergency, the cause is clearly indicated on the panel. Designed for safety Engine oil and coolant can easily be drained through a wide aperture in the base frame. The unit is fitted with a 3-pole + N circuit breaker and an earth leakage relay. An automatic main circuit breaker offers protection against overload and short circuits. The design of the quick fix electrical connections eliminates the risk of accidental contact with the terminals. The emergency stop button is recessed to prevent damage, but can be quickly accessed without opening the main unit door. Sockets, door handles and the fuel filler are recessed to avoid damage and injuries to third parties. Handles and filler can be locked to prevent unauthorised access or operation. Easy maintenance Wide opening doors offer excellent accessibility to all components. The fuel, oil and air filters are all within easy reach. Attention was paid to extended service intervals.

Principal data Performance data (1) Type QAS 14 QAS 18 QAS 28 QAS 38 Rated speed r/min 1500 1500 1500 1500 Rated Power Factor ( lagging) 0.80 0.80 0.80 0.80 Rated continuous apparent power kva 13 17 25 35 Rated standby power kva 14 19 28 38 Rated voltage, line-to-line V 400 400 400 400 Rated current A 19 24 36 49 Maximum sound power level (LWA) complying with 2000/14/EC OND db(a) 90 91 95 95 Max. sound pressure at 7m and 75% load db(a) 62.6 63.3 66.5 65.8 Fuel autonomy at full load h 26.5 21.5 19 13.5 Capacity of fuel tank l 85 85 100 100 Fuel consumption 100% load l/h 3.2 3.9 5.2 7.5 75% load l/h 2.5 3.1 4.1 5.8 50% load l/h 2.0 2.3 3.0 4.2 Design data ALTERNATOR Insulation - stator class H H H H - rotor class H H H H Number of phases 3 3 3 3 Number of leads 12 12 12 12 ENGINE Make YANMAR YANMAR YANMAR YANMAR Model 3TNE88-ACG 4TNE88-ACG 4TNE94-ACG 4TNE98-ACG Rated net output kw 12.8 16.4 26.1 32.9 Coolant liquid liquid liquid liquid Number of cylinders 3 4 4 4 Bore mm 88 88 94 98 Stroke mm 96 96 100 110 Swept volume l 1.642 2.189 2.776 3.319 Unit (2) Dimensions : Length mm 1860 1860 2080 2080 Width mm 811 811 951 951 Height mm 957 957 1157 1157 Weight (dry) kg 656 714 826 901 Weight (ready-to-operate) kg 735 793 942 1017

QAS 48 QAS 78 QAS 108 QAS 138 QAS 150 QAS 200 QAS 250 QAS 300 1500 1500 1500 1500 1500 1500 1500 1500 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 45 69 100 125 150 200 250 300 50 76 110 138 165 220 275 330 400 400 400 400 400 400 400 400 65 100 145 180 216 289 360 433 95 95 95 98 98 98 98 98 68.1 66 67.6 70.2 70.3 69.6 70.1 71 16 11 13.5 11 16 13 11 9 175 175 310 310 530 530 530 530 10.9 16.0 23.3 28.3 33.6 40.6 51.4 61.7 8.3 12.3 17.6 21.6 25.0 31.4 38.6 45.2 6.2 8.8 12.6 14.5 17.8 22.2 27.1 31.3 H H H H H H H H H H H H H H H H 3 3 3 3 3 3 3 3 12 12 12 12 12 12 12 12 PERKINS PERKINS PERKINS PERKINS VOLVO VOLVO VOLVO VOLVO 1004-G 1004-TG 1006-TG2 1006-TAG TAD72OGE TWD74OGE TAD74OGE TAD1032GE 42 65 91.5 110 132 181 220 266 liquid liquid liquid liquid liquid liquid liquid liquid 4 4 6 6 6 6 6 6 100 100 100 100 108 107 107 120 127 127 127 127 130 135 135 140 3.990 3.990 5.990 5.990 7.150 7.280 7.280 9.600 2562 2562 3112 3112 3471 3471 3955 3955 1031 1031 1131 1131 1431 1431 1431 1431 1307 1307 1507 1507 2128 2128 2128 2128 1395 1485 1986 2096 3005 3296 3443 3851 1562 1662 2266 2424 3383 3740 3860 4240 1) Reference condition For engine performance to ISO 3046/1-1995 Air inlet temperature from -18 C to 40 C Max. altitude above sea level: 1000 m Fuel specific weight: 0.84 Rating definitions All units are designed to supply continuous electrical power at full and variable load without limitation to the annual number of hours of operation and with a 10% overload capacity during one hour per 12 hours. 2) Configuration D to ISO 8528-1: 1993 with baseframe, integrally mounted control gear, switchgear and auxiliaries, in enclosure.

Optional equipment Options Electronic speed governor 50 OR 60 Hz Electronic speed governor 50 AND 60 Hz Multi-voltage with selector switch Low voltage Earth leakage relay (EDF) Remote start Automatic start (AMF) Over/under voltage relay (O.U.R.) Battery charger Coolant heater Changeover contactor 60 A Changeover contactor 110 A Changeover contactor 200 A Changeover contactor 325 A Changeover contactor 400 A Changeover contactor 500 A Insulation monitoring relay (IT) Spillage free External fuel tank connection Atlas Copco towing eye DIN towing eye Ball coupling NATO towing eye Parallelling kit Lighting tower Customized colour QAS14 QAS14S* QAS18 QAS18S* QAS28 QAS28S* = standard = available = not available * With sockets Single axle portable generator Paralleling kits allow parallel operation of two or more QAS150-300 generators. Twin axle portable generator

QAS38 QAS38S* QAS48 QAS48S* QAS78 QAS78S* QAS108 QAS108S* QAS138 QAS138S* QAS150 QAS200 QAS250 QAS300 External fuel tank connection Atlas Copco allows you to work 24 hours a day with a QAS 14 on trailer equipped with a lighting mast. Its 9 kw lighting power turns night into day for non-stop activity on construction sites, at road works, nocturnal sport events or leisure festivals. Automatic start module Changeover contactors