Mining service breakers with true rms sensing designed specifically for trailing cable applications

Similar documents
Siemens is proud to offer the mining breaker of choice for the coal industry. Siemens is fully committed to the mining industry, with a complete

Engine Generator Circuit Breakers

The circuit breaker of choice for the mining industry. usa.siemens.com

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Pow-R-Flex low ampere busway

Bolted contact switches. Pringle switches

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

W-VACi MV circuit breakers

Product Line Overview. The Most Logically Designed Contact Assembly

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

PowerPact B. Molded case circuit breakers and switches from A

E-VAC Series Medium Voltage Vacuum Circuit Breaker

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

MP-4000 Motor Protection

Low voltage circuit breakers

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Magnum IEC Low Voltage Air Circuit Breakers

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Horizontal Circuit Switchers

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

VL Circuit Breaker DG 150A frame

Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers

Comprehensive circuit protection for control panel applications

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Type BR thermal magnetic trip curve results

Tmax Molded Case Circuit Breakers

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

3. Coils shall be of molded construction

IN2 Enclosed Switches and Circuit Breakers

Quick selector reference guide. Motor Control Center Aftermarket Buckets

OTEC Transfer switch open transition

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Eaton vacuum interruption (EVI) technology. Proven vacuum interruption technology Environmentally focused circuit protection for global innovation

Horizontal Circuit Switchers

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Powering business worldwide

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Enclosures. See Section Typical Description

University of Houston Master Construction Specifications Insert Project Name

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Moulded case circuit breakers

Experience, innovation and reliability

XIRIA Green, Smart, Compact solution

Medium voltage vacuum circuit breaker. E-VAC series

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Power Break II Switchboard

Professional Engineering Services. Service Focus. PowerChain Management Audit

Consumer Units and the 17th Edition Product Focus. Meet the new regulations How to avoid confusion

Thermal-Magnetic For Mining Applications Class 600

Molded Case Circuit Breakers

UBW Family UL489 Molded Case Circuit Breakers

Transfer switch GTEC open or delayed transition

Reliably Switching Highest Currents up to 2200 A

XT UL short-circuit. current ratings. Technical Data TD E. Contents

Tmax Molded Case Circuit Breakers

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Transfer switch OTEC open or delayed transition

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Installation Instructions for NW, HNW, and NWC Circuit Breakers and N-frame Series C Molded Case Switches

DETAIL SPECIFICATION SHEET

Bussmann series Quik-Spec Power Module Switch elevator disconnect

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

DPX Magnetic only

Solid Dielectric, Single Phase Recloser

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Section 3: Molded Case Circuit Breakers

N-frame Circuit Breaker

F-Series. Circuit Breaker

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

Transcription:

Eaton Mining Service Circuit Breakers E 2 Series 15 2000 Amperes 600 and 1000 Vac Mining service breakers with true rms sensing designed specifically for trailing cable applications

E 2 mining service breakers and plug-in field mountable accessories The tradition continues E 2 mining service breakers With Eaton s mining service circuit breakers, we re continuing a 40-year tradition of being the undisputed leader in electric power distribution to the mining industry. E 2 mining service breakers exemplify Eaton s commitment to the mining industry: to provide the mining service breakers that customers said they need! State-of-the-art E 2 mining service breakers incorporate the rigid specifications and testing procedures developed by a focus group led by engineers from several large coal companies and Eaton design engineers. Additionally, the performance of these breakers was proven and verified during hundreds of hours of field testing in harsh mine environments. Proven performance E 2 mining service breakers are designed for a broad range of mining applications, especially for trailing cable protection per MSHA 30 CFR 75. E 2 mining service breakers are available in seven frames trip units are interchangeable between 600 Vac and 1000 Vac E 2 frames. E 2 breakers also cover all trailing cable sizes with just two frames and three trip units. Electromechanical trip units are also available with a wide range of magnetic pickup settings. Mining service electronic trip units with rms sensing provide the highest accuracy possible E 2 K- through R-Frame breakers provide the mining industry with true rms sensing, made possible by the patented custom ASIC microprocessor in each electronic trip unit. The trip units available in Instantaneous Only and Long/Instantaneous are field interchangeable and provide eight adjustable instantaneous pickup settings. Current sensing circuits provide inverse time delay tripping adjustments for overload conditions, and instantaneous tripping for protection against short-circuit conditions that exceed preset conditions. In open air at 40 C, the breaker will carry continuously a current equal to its maximum ampere rating without exceeding a 50 C rise at the terminals. The instantaneous pickup settings conform to the Code of Federal Regulations 30 75.601-2 for trailing cable applications and cover conductor sizes from #14 to 500 kcmil with three trip units and two frames. Refer to the Trailing Cable Protection Setting chart on page 4. A Long/Instantaneous trip unit will trip the breaker within two hours for an overload of 135 percent and trip in less time for higher overloads. If shortcircuit conditions exceed the pickup settings, the trip unit initiates an instantaneous trip. Long/Instantaneous trip units include instantaneous pickup settings designed to conform to MSHA requirements. Thorough in-plant testing ensures quality, dependability and reliability The E 2 mining breaker, with its undervoltage release, has been tested for 10,000 tripping operations, plus maximum short-circuit and overload tests at 1000 Vac. Additionally, factory tests are conducted on every pole of every breaker to verify the trip unit calibration, continuity and accuracy. Easy and uncomplicated field testing Each E 2 mining breaker with electronic trip unit includes a built-in test port for convenient field testing with the hand-held, 120 Vac test kit. The kit checks the trip unit electrically, and an operator can quickly verify the integrity of the trip unit and check all functions except the CTs. For mechanical testing, the push-to-trip button checks the tripping function and should be used to exercise the operating mechanism during scheduled maintenance. Field replacements All trip units and accessories are field replaceable. See the Mining Breaker Replacement Cross-Reference chart on page 3 for more information. Contact your Eaton distributor or sales engineer for further details. 2 EATON CORPORATION Eaton Mining Service Circuit Breakers

Plug-in field mountable accessories 120 Vac Electrical Reset Undervoltage Release with LED Indicator Helps extend the breaker s mechanical life Shunt Trip Provides remote-controlled tripping Auxiliary Switch Remotely indicates open or closed contacts 120 Vac electric reset undervoltage release (UVR) with LED indicator Monitors a voltage (typically a line voltage) and trips the breaker when the voltage falls to between 70 and 35 percent of the solenoid coil rating. The electric reset will not permit the breaker to be reset without power to the UVR. The LED, when lit, indicates that the UVR is energized. The breaker should not be reset when the LED is not lit. Through visible indication of the UVR status, the operator can know when the breaker can be closed or reset. The electric reset and LED features help extend the breaker s mechanical life. NNote: UVR mechanism accessories are not designed for, and should not be used as, circuit interlocks. Shunt trip Provides remote-controlled tripping and includes an intermittent rated solenoid with a tripping plunger and a cutoff switch mounted on a plug-in module. On AC rated shunt trips required for use with ground fault protection devices, most solenoids are suitable for operation at 55 percent of rated voltage. Auxiliary switch Remotely indicates if the breaker contacts are open or closed. It consists of one or two SPDT switches housed in a plug-in module. Each SPDT switch has one a and one b contact. When breaker contacts are open, the a contact is open and the b contact is closed. Interrupting Capacity Interrupting Capacity (Symmetrical ka) Circuit Breaker Vac (50/60 Hz) Vdc Type 240 480 600 1000Y/577 250 E 2 F 65 25 18 10 E 2 J 65 35 18 10 E 2 K 65 35 25 10 E 2 LME 100 65 35 42 E 2 L 65 35 25 22 E 2 M 65 35 25 22 E 2 N 65 50 25 E 2 R 125 65 50 E 2 FM 25 18 10 10 E 2 JM 35 18 10 10 E 2 KM 35 25 14 10 E 2 LMZ 100 65 35 10 42 E 2 LM 35 25 14 22 E 2 MM 35 25 18 22 E 2 NM 50 25 25 E 2 RM 65 50 25 A Two poles in series. Breakers with electronic trip units are not DC rated. Other accessories A bell alarm that indicates if the breaker tripped, rotary and Flex ShaftE handle mechanism, and electric operator for remote operation are also available. All accessories are provided with standard 18-inch leads. An optional terminal block is available. For more information Contact your Eaton distributor or sales engineer for additional information on mining service circuit breakers. Selection Data: CA01217001E Dimensions: TD01217001E This information can be found on the Eaton Web site at www.eaton.com. For the location of your local Eaton distributor, call toll free 1-800-525-2000. Mining Breaker Replacement Cross-Reference Chart 600 Vac 1000 Vac E 2 Mining Classic Series CT E 2 Mining Classic Series C E 2 F FBM FDBM E 2 FM HFM HFBM FDM HFDM (Mag. Only) E 2 J JDM E 2 JM JDCM E 2 K KAM KDM E 2 KM HKAM KDCM KAMH E 2 L LAM LDM E 2 LM HLAM LDCM LAMH HLCM LCM LCMH E 2 M MAM E 2 MM HMAM MAMH HMCM MCM MCMH E 2 N NBM E 2 NM HNBM NBMH HNCM NCM HNBMH NCMH HLCLM E 2 R E 2 RM A HPMB A E 2 R/E 2 RM is a new frame physically different from the HPBM. See TD01217001E.

Instantaneous Only D C B E F G A H A = 200A E = 800A B = 300A F = 1000A C = 500A G = 1250A D = 600A H = 1500A Long/Instantaneous D C B E F G A H A = 200A E = 800A B = 300A F = 1000A C = 500A G = 1250A D = 600A H = 1500A Time Time A Current A Current H H Trailing Cable Protection Setting per MSHA 30 CFR 75 Conductor Size Maximum Breaker Instantaneous Setting Maximum Ampere 75 C Insulated Conductor E 2 MM Breaker 1000V E 2 Instantaneous Only Mining Breaker 14 50 15 E 2 KM 150A A 12 75 20 E 2 KM 150A B 10 150 30 E 2 KM 150A C 8 200 50 E 2 KM 225A A 6 300 65 E 2 KM 225A B 4 500 85 E 2 KM 225A/E 2 LM 400A C/A 3 600 100 E 2 KM 225A/E 2 LM 400A D/B 2 800 115 E 2 KM 225A/E 2 LM 400A E/C 1 1000 130 E 2 KM 225A/E 2 LM 400A F/D 1/0 1250 150 E 2 KM 225A/E 2 LM 400A G/E 2/0 1500 175 E 2 KM 225A/E 2 LM 400A H/F 3/0 2000 200 E 2 LM 400A G 4/0 2500 230 E 2 LM 400A H 250 2500 255 E 2 LM 400A H 300 2500 285 E 2 LM 400A H 350 2500 310 E 2 LM 400A H 400 2500 335 E 2 LM 400A H 500 2500 380 E 2 LM 400A H Two Types of Electronic Trip Units Instantaneous Only and Long/Instantaneous Trip Setting EATON CORPORATION Eaton Mining Service Circuit Breakers 4

Factory service for molded case circuit breakers The Breaker Service Centers are extensions of our manufacturing plants. They are the only facilities authorized to service Eaton s Cutler-HammerT series and classic WestinghouseT circuit breakers. When and where to use Minor physical damage to a handle, a lug, or the like, which otherwise would be fully functional Circuit breaker that has experienced some normal wear, but is in generally good condition, as an economically driven alternative to new Breaker exchange Eaton offers credit toward the purchase of our new breaker technologies (E² Mining and Series CT Industrial) in exchange for the old breaker Why use Eaton factory service? Reduces overall breaker cost of ownership Greater reliability when compared to unknown third-party refurbishing Circuit breakers are tested to ensure that the manufacturer s specifications are met Simple and convenient solution with quick turnaround on many frame styles One-year manufacturer s warranty Factory trained The Service Center staff is dedicated to providing genuine factory-supported services and solutions to our customers. Factory-trained technicians Modern state-of-the-art cleaning and test equipment Dedicated facility supported by design and manufacturing technology center engineers Capabilities Basic tune-up clean, test, re-certify Basic service replace accessories and attachments, including terminals, trip units, UVRs, shunt trips and auxiliary switches Service plus replace components, including covers, handles and stationary contacts Basic modifications accessory installation for new or existing operational breakers Custom service trip unit upgrades, frame or trip unit replacement ULT modifications to factory-sealed breakers Service Center locations There are two Breaker Service Centers ready to serve you: Skelton, WV Evansville, IN Please call 1-877-BRK-SRVC (factory service for molded case circuit breakers) or contact your local Eaton authorized distributor or sales office for more information. Mine Safety and Health Administration (MSHA) Program information bulletin: P06-02 MSHA recommends repairing circuit breakers to the original manufacturer s specifications using components exactly like those furnished by the manufacturer. Independent repair shops, the original equipment manufacturer (OEM) or an authorized OEM repair shop can repair circuit breakers when replacement components exactly like those furnished by the manufacturer are available. Before modifying any molded case circuit breaker or repairing any circuit breaker with components other than those from the manufacturer, consult the manufacturer to determine if the modification will have any adverse effect on the circuit breaker. Because circuit breaker designs and specifications are proprietary information, independent repair shops may not be able to obtain the required specifications from the manufacturer. If the independent repair shop can not obtain the specifications, the circuit breaker should be modified by the OEM or an authorized OEM repair shop. Mine operators are ultimately responsible for all repairs and modifications made to the circuit breakers whether made by the OEM, an authorized OEM repair shop, independent contractor or by a repair/rebuild shop facility. The mine operator must make sure that all repairs are made in a workmanlike manner and that any modifications will not adversely impact the performance of the circuit breaker. Learn more at http://www.msha.gov 5 EATON CORPORATION Eaton Mining Service Circuit Breakers

Eaton s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton s full-scale engineering services, these products provide customer-driven PowerChain ManagementT solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR01217001E / Z9518 January 2010 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.