Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

Similar documents
OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Operators Manual DL3100. Dualine Automatic Spray Systems Installation, Operation, Parts List. DL3100 r#3

Medium and high pressure pumps

Purging Air From Divider Block Lubrication Systems

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

Suggested Installation & Operating Instructions for Sidewinder Pumps

Trouble Shooting Guide EWA, 3-phase (D2422)

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

Suggested Installation & Operating Instructions for Sidewinder Pumps

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

Operators Manual SL3100. Singline Automatic Spray Systems Installation, Operation, Parts List

Troubleshooting the Transmission Hydraulic System

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Operating Instructions & Parts Manual

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

VS403 INSTRUCTIONS FOR: VACUUM AND PRESSURE TEST / BRAKE BLEEDING UNIT MODEL: SAFETY INSTRUCTIONS INTRODUCTION & CONTENTS. fig.1

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

TYPE E Main Valve Sizes 3 /8 through 12

Standard Power Units Start-Up and Maintenance

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Operating Instructions & Parts Manual

farval DUaLINE SYSTEMS Ideally suited for heavy industry Continuous duty operation Over 80 years of excellence

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

SERVICING INSTRUCTIONS

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

EQUALIZER International Limited 10T(I) Integral Hydraulic Spreading Wedge Repair Instruction Manual

Portable Oil Free Silent Series Compressor Operating Instructions

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

INSTALLATION AND OPERATING MANUAL

INSTRUCTIONS FOR: VACUUM TESTER AND BRAKE BLEEDING KIT

Air-Assist Service Jack Max. Capacity: 10 Tons

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

INSTRUCTION MANUAL. Portable Greasing System S1180, REV C GS

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

Owner s Manual. LTS Hide-A-Way Truck Side Gate

FARVAL DUALINE SYSTEMS. + Ideally suited for heavy industry + Continuous duty operation + More than half a century of excellence

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

Vickers. Service Data. Vane Pumps. Quiet Intra-Vane Single Pumps. 25V(T)-35V(T)-45V(T) Series 20 Design 282/283 Series

TABLE OF CONTENTS. Tow Behind Bulk Bin Brake Release Procedure... H-3. General Hydraulic Repair Procedure... H-4

END SUCTION CENTRIFUGAL PUMPS

13. FUEL SYSTEM/CARBURETOR/

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200}

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

SERVICE MANUAL / PARTS LIST

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

FARVAL DUALINE SYSTEMS + + Ideally suited for heavy industry + + Continuous duty operation + + Over 80 years of excellence

Maintenance of Pleasureboat Diesel Engine GM Series

Low Profile J Series Power Unit with Vane Pump

DP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09

Original Language Version VS4021 Issue: 1-08/06/12

Under Axle Jack Max. Capacity: 25 Tons

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

SAFETY AND OPERATING MANUAL

t EVAPORATOR PRESSURE REGULATING VALVES

OPERATION AND PARTS MANUAL

Parts List. Item # Part # # Reqd. Description

Air / Hydraulic Under Axle Jack

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

WORKSHOP MANUAL. 63,4 cm³ chainsaws

KJ4000LW Operating Instructions & Parts Manual NSN

Routine Compressor Maintenance

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Table of Contents. AMO series quantitative pressured centralized lubricating system 1. Illustration of AMO motor driven lubricating system 1

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

SERVICE MANUAL / PARTS LIST

MP18 Stacking Valve System Technical Information Manual

LAWN SPRINKLER, IRRIGATION PUMP

Instruction Manual. Maximum Operating Pressure 510 bar

FUEL SYSTEM/CARBURETOR/FUEL PUMP

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

Starting up hydraulic systems

HE Stewart Vacuum Gasoline System employs a small tank, installed under the hood. This tank is connected by brass tubing to the intake manifold, also

M-3025CB-AV Fuel Pump

FABER BURNER ROUTINE MAINTENANCE

980 B Wheel Loader S/n 89P1 & Up Volume 1 of 2

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL

CONTENTS. EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5

INSTALLATION AND OPERATING MANUAL

Pump Operating and Maintenance Manual - Models

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

The Cyclone Maintenance Manual

Air / Hydraulic Pump

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Transcription:

Farval Dualine Installation System Start-Up Bulletin DL300 BIJUR DELIMON INTERNATIONAL 2685 Airport Road Kinston, NC 28504 Tel. 800-227-1063 Fax: 252-527-9232 website: www.bijurdelimon.com

DC1-1 SECTION DC SYSTEM INSTALLATION AND START UP (For Dualine Automatic Electric Powered and Air Powered Systems) First study the schematic layout, the bearing list, and the applicable Farval publications describing dualine systems. Together they completely describe the system and its component assemblies. They also explain how the system and its component assemblies operate and how the various sub-assemblies-the pump, the reservoir, valve manifolds, and controls should be combined. In addition to becoming well acquainted with the lubricating system, it is often helpful to sketch the location of all manifolds and lube lines on the machine with chalk or crayon. INSTALLATION Pump Reservoir Assembly-Locate where it is protected from dirt and where it can be easily maintained and filled with lubricant. Bolt to a solid foundation (except air powered barrel pumps). Measuring Valves-Mount on a flat surface close to the bearings (within 10 feet) and close to the machine for protection but where accessible for adjusting and servicing. Valves may be mounted in any position but indicator stems should be visible and should face the same direction for easier checking. Mount with indicator stems down if excessive dirt and scale are present or order U-1732 indicator covers. Adjacent valve blocks may be piped together before mounting, using one union in each pipe connection between valves. Any welding of valve support brackets to the machine should be done before mounting valves. Supply Lines-Clean inside of all pipe, not meeting Bulletin 1800 pipe specifications, as follows: (a) if unpickled black pipe- shot or sandblasting, solvents, or a tube descaler (b) if galvanized pipe-drifting or sandblasting. Remove scale and spatter from pipe welds by thoroughly pounding, tapping, and blowing out with air. Remove chips produced by threading pipe before connections are made. Prefill measuring valve to bearing discharge lines of grease systems with clean grease. It saves startup time and prevents overfilling of short discharge lines while waiting for long discharge lines to fill. Use hand pump, grease gun, or power pump. Fill entire coil of copper tubing with grease before cutting and installing. Keep lines short. Place close to machine for protection and cover with a protective shield in hazardous locations. Clamp rigidly. Connect each supply line to the same port on each measuring valve (see Figs. 1 and 2) so that indicator stems will move in the same direction, making erratic performance more obvious. Do not connect discharge lines to bearings until later (see page DC1-3 under Bearings ). Bleeder Valves-Install at high points to purge system of air. Line Strainers and Line Checks-Install as shown in Fig. 1.

SYSTEM INSTALLATION AND START UP DC1-2 INSTALLATION INSERT PLUGS AFTER SYSTEM HAS BEEN FILLED WITH LUBRICANT, PURGED OF AIR AND READY FOR OPERATION-SEE FILLING SYSTEM WITH LUBRICANT. RESERVOIR ADD LINE STRAINERS TO RETURN LINES OF SYSTEMS WITH COMPLETE LOOPS AND TO DISCHARGE LINES OF END-OF-LINE SYSTEMS THEY REMOVE FOREIGN MATTER WHICH MAY BE ADDED DURING INSTALLATION. REVERSING VALVE OF SOME CS2000 & DC42 STATIONS NEED EXTRA PIPE PLUG. SEE REVERSING VALVE BULLETINS DL-1200 ADD 2-WAY LINE CHECKS U-1929B TO DISCHARGE LINE OF ALL OIL SYSTEMS. THEY PREVENT LINE DRAINAGE WHILE SYSTEM IS NOT OPERATING. DO NOT INSTALL ONE-WAY CHECKS. THEY BLOCK RELIEF TO RESERVOIR IN IDLE SUPPLY LINE. Fig. l-a typical automatic loop system. Pressure Control Switches (End-of-Line Systems with FR Reversing Valves)-Can locate anywhere in the line. If there is more than one set of main supply lines, install switches in the set with greatest pressure drop (usually the longest) and in others with pressure drops of similar magnitude. See Fig. 2. PRESSURE SWITCHES U-620Dl OR U-663-6 OPERATE SOLENOID RE- VERSING VALVE & STOP PUMP WHEN MAX. SYSTEM PRESSURE IS REACHED. PRESSURE GAUGES U-902F HELP SET MAXIMUM SYSTEM PRESSURE Fig. 2-DC41 System showing use of pressure switches. Pressure Gauges (End-of-Line Systems with DR Reversing Valves)-Add pressure gauge U-902F (0-5000 psi) where distribution line ends at last measuring valve to help adjust system pressure during start up period. Electric Wiring-Connect motor so that pump rotates as shown in the detail section. If there is more than one set of main supply lines with pressure control switches, wire. the corresponding switches in each main line in series so that full line pressure develops throughout system before pump stops. See appropriate controller bulletin for wiring diagram.

DC1-3 SYSTEM INSTALLATION AND START UP FILLING SYSTEM WITH LUBRICANT The procedure described below assures removal of air from all parts of the system. Air, trapped in the pump throat, can prevent priming on the first stroke and result in damaging the pump cylinder and piston. Air, trapped in the supply lines, will prevent the pump from developing system shut down pressure without long operating periods and subsequent time-out of the fault signal timer. Pump Gear Housing (CS1000, CS2000, DC41 and DC42 only): Before starting pump, fill gear housing to level shown in the applicable drawing in the pump section with a compounded steam cylinder oil containing 5 to 10% acidless tallow with a viscosity of 150 SSU at 210 F. Change two weeks after the initial fill and yearly thereafter. Reservoir:* Fill with clean lubricant. A. CS1000 & CS2000 Grease Reservoirs: Fill until grease exhausts thru relief hole on top. B. DC41, and DC42 Grease Reservoirs when Completely Empty: To eliminate air, add several quarts of heavy cylinder oil before filling balance with grease. Also, open air bleeder valve U - 127B (it is located near top of the follower indicator rod) to permit excape of air below follower plate. Air Control Panel. Set controls on air control panel to meet requirements of the air barrel pump. Supply Lines (air barrel pumps only): Fill the pump to reversing valve lube supply hose by disconnecting it at the point where it attaches to the reversing valve inlet port and operating the pump until lubricant appears at the end of the hose. The pump may be started and stopped by manually tripping the reset lever on the timer, or operating the manual override button on top of the air pump s solenoid valve. Re-connect the hose. Supply Lines: Fill With clean lubricant by operating system pump or, preferably by using a high volume high pressure barrel pump. During this period, disconnect both main lines at their terminating point. This is at the reversing valve if lines form a complete loop or at the last measuring valve if lines end there. Open air bleeder valves located at high points in the pipe lines and then close them in sequence starting with the pump and working outward as lubricant, free of air and foreign matter, emerges. When lubricant flows from the end of one line free of air and foreign matter, reconnect that line, and run pump until reversing valve operates Allow pressure to dissipate in that line then fill, purge, and reconnect the other line in the same manner. NOTE: Disconnecting of supply lines helps operator identify lines of systems with DR4 type reversing valves (CS2000 and DC42). Supply line #1 must connect to return line #1 and supply line #2 to return line #2. Fill and purge branch lines leading off main supply lines as described above. Branch lines must be unplugged at their ends until a solid flow of clean, air-free lubricant appears. See Fig. 1. Bearings: Fill with lubricant. To assure removal of all air, use a hand gun or oil can. Connect discharge lines to the bearings. Fig. Fig. 3- CS2000 Station w/(dr-4) Reversing Valve Valve *These stations can handle most NLGI#1 grease and, under certain conditions, NLGI #2 CAUTION: Pump drive shaft must rotate In direction recommended In applicable pump section or as shown by arrow on pump housing. Incorrect direct on of rotalion will damage CS1000, CS2000, DC41 or DC42 pumps

SYSTEM INSTALLATION AND START UP DC1-4 SYSTEM START UP System Pressure-Adjust to between 300 and 700 psig at the end of the most remote branch of the main supply lines (600 psig is usually satisfactory) by turning the pressure adjusting screw.- This pressure is indicated by gauges at the adjustment point (for example the B gauges in Figs. 4 and 5). Note: Pressure drop thru the systems shown below equals the difference between the A and B gauges. It results from pressure losses in the supply lines, in the measuring valves, and in injecting lubricant into the bearing. With pressure set at 600 psig on the B gauge, pressure at the A gauge might be as high as 1200 psig but varies somewhat with the temperature (it tends to rise with falling temperatures) even though return line pressure gauge readings remain constant. If the system has been shut down for a number of hours, pumping time for the first two or three cycles may be 10 to 15% longer than for subsequent cycles. Timer---Set the station timer. Fig. 4-DC41 End-of-line system with solenoid reverser. Fig. 5-DC42 Loop system with hydraulic reverser. *Make pressure adjustments at pressure control switches U-620Dl or U-663-6 on systems with FR valves. at the DR type reversing valve on CS1000. CS2000, DC36, or DC42 systems.

DD1-1 SECTION DD SERVICE INSTRUCTIONS MAINTENANCE INTRODUCTION This section covers service and trouble shooting instructions for complete automatic systems. Additional instructions for various system components may be found in other publications covering specific systems. PREVENTIVE MAINTENANCE 1. Keep reservoir filled. A pump operating with an empty reservoir will force air into the system causing difficulty in building pressure, preventing pump from priming, or even damaging the pump pistons. 2. Use clean lubricant-foreign matter may clog pump or reservoir filler screen. Keep the line strainers clean. They are usually installed in the lines near the reversing valve. Reservoirs should be filled by a portable grease pak or drum transfer pump. CS1000 and SC2000-clean filler screen and filler connection assembly regularly and pressure relief valve as needed. See applicable pump section. DC41 and DC42-Strainer-pressure relief valve assembly (shown in Fig. 4 Page DC1-4): Clean strainer-screen at regular intervals and pressure relief valve as needed. 3. Inspect entire system regularly including tubing and hose (replace if damaged), connections (they should be tight), all bearings (a small amount of lubricant should show at the edge of each one), and measuring valve stems (they operate during each lube cycle.) WARNING: All CS1000 and CS2000 grease reservoirs are equipped with springs which produce a force of 200 pounds when reservoir is filled. Empty reservoir before removing its top end cap. HOW TO LOCATE AND CORRECT TROUBLE 1. To locate trouble, replace distribution lines at the reversing valve as follows: On loop systems, form two pieces of copper tubing into loops. Connect each loop between a discharge port of the reversing valve and its corresponding return port. Flatten the loops sufficiently at the center to build resistance. Start pump with timer. If pump builds pressure and the reversing valve operates at normal system pressure the trouble is in the lines. On systems with no return, install a pipe plug in each discharge port of the reversing valve. Start pump with timer. If it can build pressure to the relief valve setting (normally it is factory set at: 2400-2500 psi on DC41 & DC42; 1400-1500 psi on CS1000 & CS2000), the trouble is in the lines. Note: Solenoid reversing valves can be checked hydraulically by operating them manually. Remove the plastic plugs at each end and push the piston back and forth. 2. Air in system shows up when the pump fails to build pressure, to prime properly, or when grease level indicator stem rises faster than it should after the system is operated. Correct by cleaning out reservoir and then filling and purging the entire system as described under Start Up Procedure.

SYSTEM INSTRUCTIONS MAINTENANCE DC1-2 TROUBLESHOOTING* CONDITION CAUSE A. System will not 1. Broken Main Line or loose fitting. build pressure. 2. Air in system. 3. Pump losing prime. 4. Pressure relief valve not working properly. (All except air operated barrel pump units which have no relief valve). REMEDY 1. Find break and replace line. 2. Bleed air (Page DC1-3). Check lube level in reservoir. 3. Check lube viscosity. Check for air in reservoir. 4. lncrease pressure setting, tighten retainer screws, or clean as needed. 5. Motor drive shaft direction of rotation reversed. One way clutch coupling is free wheeling. (CS1000, CS2000 and DC36 do not have free wheeling clutches). 5. Repair. Check wiring and change rotation. See pump section for correct pump drive shaft rotation. 6. Suction strainer screen dirty. (DC36 only). 7. Pump shaft seal worn (DC36 only). 8. Pump cylinder not shimmed correctly. (All except DC36 & air operated barrel pumps). 6. Clean or replace. 7. Squirt oil on pump shaft next to shaft seal. If pump then primes, seal is worn and pump or seal should be changed. 8. Re-shim per applicable pump section. 9. Pump worn. (All except air operated barrel pumps). 10. Pump-motor coupling loose. 11. Pilot piston missing in one of the measuring valves (possibly omitted during cleaning). 9. Check pump output--page DD1-1. If it cannot build pressure, replace piston and cylinder per applicable pump section. If a DC36, replace entire pump. 10. Check and tighten. 11. Pressure one supply line to see if all flow comes back thru 2nd line in relief. If so, isolate valves one at a time starting at pump and working outward until valve without piston is found. Also check items A4 and A6 above. B. System will not 1. Excessive leakage at fittings. reverse. 2. Air in system. 3. Crossed lines (for loop systems only). 4. Reversing valve damaged. 5. Pilot piston missing. 1. Tighten. 2. Bleed air (Page DC1-3). Check lube level in reservoir. 3. Supply line #1 must connect to return line #1 and supply line #2 to return line #2. 4. Disassemble and inspect. 5. See paragraph A11 above. Troubleshooting continued on back page.

DC1-3 SYSTEM INSTRUCTIONS MAINTENANCE TROUBLESHOOTING (continued) CONDITION CAUSE C. System will not 1. Wiring not correct. start. 2. Micro switch on reversing valve broken. 3. Timer damaged. 4. Motor starter overload tripped. D. One-way coup- 1. Broken aspring in U-9792CCW clutch ling slipping. coupling. (DC41 & DC42 only). 2. Motor running in wrong direction. (CS1000, CS2000, DC41, and DC42 only). E. System builds 1. Lube viscosity too high. too much pressure. 2. Main line pipe too small. 3. DR4 type hydraulic reversing valve pressure is set too high 4. DR2 type hydraulic reversing valve gear sector teeth broken or pilot piston scored and binding. 5. Pressure control switch U620-D1 or U663-6 is erratic in operation. (DC41 only) F. Measuring valves 1. Valves dirty. will not operate. 2. Bent indicator stem. 3. Packing too tight. 4. Mounting screws too tight. 5. High resistance in bearing. REMEDY 1. Check see wiring diagram inside timer. 2. Replace. 3. Check per timer section. 4. Reset. 1. Replace 2. Change wiring to motor pump must turn clockwise from drive end. 1. Change to lighter lube. 2. Replace with larger pipe. 3. Reset reversing valve pressure. 4. Turn adjusting screw until it falls inside valve. Then remover cover. If sector arm will not move in either direction by hand,the sector teeth are probably broken or the piston is scored and binding. Return to factory for repair. 5. Clean 1. Clean. 2. Replace 3. Ream packing with drill same size as indicator stem. 4. Back off. 5. Apply hand gun to bearing inlet to see if bearing is drilled or reamed properly. BIJUR DELIMON INTERNATIONAL 2685 Airport Road Kinston, NC 28504 Tel. 800-227-1063 Fax: 252-527-9232 website: www.bijurdelimon.com DL-300 BULLETIN 03/2011