Product Manual for Deep Cycle Batteries

Similar documents
Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

Proper Torque Values for Connection Hardware. 90 to 100 in-lbs

Chapter 3. Direct Current Power. MElec-Ch3-1

O P E R A T I N G I N S T R U C T I O N S

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

EnergyCell FLA Series. Owner s Manual

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

TROJAN BATTERY USER S GUIDE

MP V 8A Electronic Smart Charger. Instruction and Information Manual

CAUTION ONE MEAN BATTERY

Installation & Maintenance Manual

MAxxIMA SOLAR BATTERY USER MANUAL

OBE, OBEXU, ON BOARD Battery Chargers

Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

IMPORTANT SAFETY INSTRUCTIONS

SP6. Automatic Battery Charger. Model

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Matching Your Load With Your PV System

RAILROAD & DIESEL STARTER

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

OBAE, OBAEXU, ON BOARD Battery Chargers

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

SAVE THESE INSTRUCTIONS

BATTERY USER MANUAL. Recommended charging, equalization and preventive maintenance procedures for Rolls Batteries.

QPET, QPETXU Battery Chargers

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Models: SP3, SPSS3 Automatic Battery Charger

Model: SE-4020-CA Automatic Battery Charger

Basic Battery Safety. Lead Acid Storage Batteries

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

400 Watt Backup Power System Owner s Manual

Instructions for use

Instructions for use Attention

IMPORTANT SAFETY INSTRUCTIONS

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

12 amp RMS Battery Charger

Part Number: DBDC10 / DBDC20 DC to DC Dual Battery Charger Manual

Caution Wear protective glasses and turn your face away when connecting or disconnecting from the battery.

QSSE, QSSEX INDUSTRIAL Battery Chargers

Part Number: DCDC10S / DCDC20S DC to DC Dual Battery Charger Manual

Congratulations. on your purchase from Trojan Battery Company, the manufacturer of the

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP AND TUBULAR-LM FAST CHARGE MOTIVE POWER BATTERIES

Installation and Operating Instructions. Solar System Controller ISC3020

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

IEEE IAS Atlanta Chapter

MODEL 6017 OPERATOR'S MANUAL

FLUSH EYES IMMEDIATELY WITH WATER. GET MEDICAL HELP FAST. SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS.

A battery is like a piggy bank. If you keep taking out and putting nothing back you soon will have nothing.

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

BusPro Series Instruction Manual

Installation and Operating Instructions. Solar System Controller ISC1000

Cruising Charger Series OWNER S MANUAL

How To Set Up SimpliPhi Batteries Using OutBack Chargers

IMPORTANT SAFETY INSTRUCTIONS

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

BS20 BATTERY CHARGER For lead-acid batteries

AUTO CHARGE D PUMP PLUS

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

GASTON GTF range battery manual

HAZE 6/12 Volt. STATIONARY 6/12 Volt BATTERIES. HAZE Battery Co. INSTALLATION and OPERATING INSTRUCTIONS. Supplied Worldwide by :

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

Wide operating temperature range: Our battery will operate from -30C to (-22F) to 60C when it is fully charged.

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

RENEWABLE ENERGY SERIES. Rolls premium deep cycle batteries have been chosen as the best off-grid battery for over 25 years.

Installation and Operating Instructions. Solar System Controller ISC3030

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Intelligent Charging System Series

INTELLIGENT BATTERY CHARGER/MAINTAINER

A2P Single Phase Automatic Industrial Battery Charger

Owner s Manual. Contents GP-PWM-10-SQ

RAILROAD & DIESEL STARTER BATTERY USER MANUAL

10 AMP ON BOARD BATTERY CHARGER

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

WARNINGS, CAUTIONS AND NOTES

VRLA Batteries. Battery Installation And Start up Guide

20A Solar Charge Controller

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

User s Manual. Automatic Switch-Mode Battery Charger

Congratulations. on your purchase from Trojan Battery Company, the manufacturer of the

A48 / A48B (base plate) BATTERY CHARGER

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Transcription:

Surrette Battery Company Ltd. Product Manual for Deep Cycle Batteries Bookmark not defined. QS CODE PI 001 Revision No. 0.1 Date Issued 19-Sep-00 Supersedes NONE Number of Pages Error!

P.O. BOX 2020, SPRINGHILL, N.S., CANADA (902) 597 3767, FAX (902) 597 8447, www.surrette.com Product Manual INTRODUCTION This instruction manual will provide you with the information to safely own, operate and maintain your deep cycle batteries or cells. Receiving Your Product Before signing for the shipment, inspect it for damage and make a note of it on the shipping documents. If damage is found after delivery please contact the freight company, your dealer and Surrette Battery. Freight companies, in general, will not admit liability unless damage is documented at receiving. OPERATION Safety: A product MSDS is available upon request and safety tips are summarized as follows: NEVER short-circuit a battery. NEVER add seawater to a battery. NEVER smoke around a battery bank. ALWAYS wear safety glasses and gloves when working around a battery bank. Protective clothing such as an apron and steel toes is suggested and may be required during installation or when handling acid. ALWAYS provide adequate ventilation especially during equalization. ALWAYS remember you are working around electricity and a battery bank has the potential to deliver a severe shock. Product Do s and Don ts Do properly follow the instructions given in this manual. Do contact your dealer or Surrette Battery Company Ltd. if problems or questions arise. Do isolate starting batteries from the main battery bank. Don t add acid to batteries once they have been cycled. Don t allow the batteries to exceed 125ºF (52ºC). Don t charge batteries of different types (size) together. Page 1 of 4

Service Instructions: This section describes preventive maintenance and recommended charging procedures to maximize battery life. The leading cause of premature battery failure is improper charging and poor battery maintenance. Equalization is very important and must be preformed correctly but only as required. Preventive Maintenance When a battery is first received the cell acid levels should be checked and the battery should be put on charge. After removing from charge the specific gravity readings of each cell should be recorded and kept for the life of the battery. Preventive maintenance involves, at a minimum, checking the cell electrolyte level for correct acid volume once a month and equalizing once every six months. The cells should be watered back to the original acid level which is ¼ - ½ below the bottom of the vent well (tube inside the battery cell with slots on each side). Distilled water is highly recommended. Water containing high minerals or iron will dramatically reduce the battery life. A recommended preventive maintenance program can be summarized as follows: 1. Water each cell to original level as required 2. Equalize as required or once every six months 3. Record the specific gravity readings of each cell every three months. Occasionally cleaning the battery terminals and case / cover is a good practice and recommended. A weak solution of household baking soda and water can be used to neutralize any spilled acid (100 g per liter or 4 Oz per pint). Make sure the vent caps are securely tightened and NO soda solution gets into the battery cells. Good record keeping is stressed as review of these records can help to determine the health of the battery and can prove invaluable if system problems develop. State of Charge and Charging The truest measure of a battery s state of charge is the SPECIFIC GRAVITY of the battery acid. The following shows the approximate state of charge at various specific gravities at 77ºF / 25ºC. Page 2 of 4

% Charged Specific Gravity % Charged Specific Gravity 100% 1.255 1.275 25% 1.165 1.155 75% 1.215 1.235 0% 1.130-1.110 50% 1.200 1.180 We strongly recommend a three step charging procedure. Recommended voltage settings are as follows: (Volts per cell) 12V 24V 48V Equalization 2.58-2.67(max) 15.5-16.0 31.0-32.0 61.9-64.1 Absorption / Bulk 2.37-2.45 (max) 14.2-14.7 28.4-29.4 56.9-58.8 Float 2.20-2.23 (max) 13.2-13.4 26.4-26.8 52.8-53.5 To calculate the correct settings for another battery bank voltage divide the total nominal voltage by two and use this number as a multiplier. For example a 18V system, 18/ 2 = 9, equalization preferred = 9 x 2.58 = 23.2 V CAUTION: The ideal float voltage is the lowest voltage setting that will maintain the battery at full charge. The higher the voltage the more water the cell will consume. The minimum equalization voltage is highly recommended unless it is suspected a sulphation problem exists. Equalization Equalization is required to mix the battery acid and bring every battery plate to an equal charge. Equalization should only be performed when required or once every six months. Equalization is required when the cell specific gravities vary from highest to lowest by +/- 0.015 (1.245 1.260 at full charge). The exact particulars (such as charging time and currents) are dependent on the charging system. However, the point is to bring the batteries up to the equalization voltage and continue charging for 1-2 hours at a low current, without excessive heat. The final or finishing charging current should be 3-7% (we recommend 5%) of the 20 hr capacity in amps. If battery temperature exceeds 125ºF the battery should be taken off of charge and allowed to cool before equalization is continued. When two consistent specific gravity readings are taken a half hour apart the battery is equalized. It is recommended to water the battery cells before or half way through the equalization. This is to assure the water is completely mixed into the electrolyte. Caution: If you have HYDROCAPS remove during equalization. Page 3 of 4

BATTERY STORAGE Before storing battery(s) for an extended period of time the batteries should be watered and equalized. If not, the battery(s) will sulfate and could freeze. Disconnect the bank leads. Store battery in a cold and dry area in order to lower the amount of selfdischarge. You would expect a Surrette (Rolls) Battery to lose about 3-7% of its capacity per month. The maximum storage length is 6 months if the bulk of the storage was at cold temperatures (32ºF or 0ºC). If the battery(s) are stored in warmer climates fully charging the bank is recommended every three months. It is NOT recommend leaving the batteries on a float or trickle charge when stored unless power is required for critical components such as a sump or bilge pump. If this is the case they are really NOT stored but, in fact, on float service. WARRANTY For full details please see the official warranty policy which can be summarized as follows: 500 / 5000 series batteries: 3 years free replacement and prorated to 120 months. 500 / 5000 series cells: 3 years free replacement and prorated to 60 months. 400 / 4000 series batteries: 2 years free replacement and prorated to 84 months. Warranty covers manufacturing defects and does not include problems and failures arising from poor maintenance and improper charging techniques. The warranty does not cover cracked or broken battery cases. PRODUCT RECYCLE All lead acid batteries are fully recyclable. Please contact your local waste management center or depot for further details. TECHNICAL ASSISTANCE You should always contact your local dealer first, but remember we are always here to help. Please call 1-800-681-9914 or e-mail us at sales@surrette.com if further assistance is required. Please note we actively keep a customer comment log and any concerns or suggestions to help us better serve our customers are always welcomed and encouraged. Page 4 of 4