INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Similar documents
INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

ISLAND RANGE HOOD SPECIFICATIONS

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

UNDER CABINET RANGE HOOD SPECIFICATIONS

Viking Installation Guide

Viking Installation Guide

INSTALLATION INSTRUCTIONS

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

NUTONE RANGE HOOD NTM SERIES

Pro Island Ventilation Hoods

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

! FOR DOMESTIC COOKING ONLY!

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Installation Instructions

Type of Motor & Blower

Hood. warning. warning. caution

Designer Wall Range Hood Installation. Installation Tutorial Video

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

WhispAire Range Hood Quiet Hood

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation Instructions

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Installation. Professional Indoor & Outdoor Hoods

FADE Series Wall Axial Fans

Self-Cleaning Range Hoods

Viking Installation Guide

www. TheRangeHoodStore.com

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

Viking Installation Guide

HP190SL Series Slimline Radon Fans

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

All (-4) Models 390CFM Code Compliant

! FOR DOMESTIC COOKING ONLY!!

ceiling & inline/cabinet ventilators

WhispAire Range Hood Quiet Hood

CEILING & INLINE/CABINET VENTILATORS

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

KEES, INC. BALANCING MANUAL

VENT FLASHINGS GALVANIZED STEEL

Multi-Port Centrifugal Fans for Round Duct

Filtered Kitchen Supply Packaged Ventilator

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

Viking Installation Guide

Model ND-2 Specification

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

Ceiling and Inline Fans

Safety & Installation Instructions

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

IMPORTANT SAFETY INSTRUCTIONS

VENTING & COMBUSTION AIR GUIDE

MODERN-AIRE. For the professional or the everyday gourmet, Modern-Aire Ventilating. Range Hoods

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

ISLAND INSTALLATION WALL INSTALLATION

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

SQUARE INLINE CENTRIFUGAL FANS

SD-1250 and SD-1600 Series Smoke Dampers

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Transcription:

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally during installation. B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. C. Ducted fans must always be vented to the outdoors. D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to a maximum of 15 per 100 square feet of occupiable space, unless a back drafting test is performed or make-up air is provided. Consult a local HVAC engineer for make-up air evaluation. Page 1 US

Ducting Do s and Don ts General Requirements Observe local codes regarding special duct requirements and placement of duct against combustibles. Using Vent-A-Hood transitions (back page) will ensure proper efficiency. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Where possible, seal joints with duct tape. The hood must be ducted to the outdoors without restrictions. Blower Requirements The island dual blower unit (T200) requires round duct or equivalent (50 square inches), and the island cluster blower unit (T400) requires round duct or equivalent (113 square inches). Blower Combined Duct Dize Sq. Inch Area Vent-A-Hood Transition Island Dual (T200) 8" round or equivalent 50 sq. in. VP565 (Included) Island Cluster (T400) 12" round or equivalent 113 sq. in. VP564 (Included) Ducting Requirements NEVER reduce the duct size. Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Termination Requirements Airflow must not be restricted at the end of the duct run. A wall louver or roof jack is required for each duct run. Every wall louver or roof jack must include a gravity damper to prevent back drafts. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. YES Smooth Duct Smooth Gradual Turn NO Flexible Duct Sharp Angled Turns Page 2

Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) When installing an island range hood, it is recommended that the bottom edge of the hood be located no more than 30 above the cooking surface for optimum performance. Shown with duct cover installed (sold separately). 3) Load-bearing framework in the ceiling is necessary for the installation of an island hood. Additional framework construction may be required. Do not attach an island hood to a structure that cannot support twice the weight of the hood. If applicable, remove the duct cover from its packaging and remove the hood-mounting screws from the base of the duct cover. Install the duct cover to the load-bearing framework in the ceiling using appropriate hardware through the four inside corner mounting flanges on the top of the duct cover. 1 ½ 5 1 Dia. 1 ½ Island Duct Cover Mounting Holes (Top View) 4) Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the transition plus 1. This will allow the transition to engage 1 inside of the duct. Consult the connection diagrams (on next page) for further details on exhaust outlet placement. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is listed on the back page of this instruction sheet. Transition heights are as follows: Island Dual Blower (T200): Island Cluster Blower (T400): round duct connects to 9 tall VP565 transition (included). round duct connects to 11 1/4 tall VP564 transition (included). 5) Prepare a protective surface on the floor or countertop for the hood. Remove the hood from its packaging and place it upside-down on the protective surface for access to the inside of the hood. Page 3

Installation Details Continued 6) Remove the shipping tape that is securing the E-Z Clean shields inside the hood. Remove the E-Z Clean shields by lightly pulling each toward the end of the hood. Gently close the back draft dampers from the top side of the hood. To remove the blower housings, unsnap the suitcase latches (one on each side of the housing). The housings should be pulled forward and gently tipped to clear the blower wheels and then out of the hood. Connection Diagram (3-4 Widths) Of Hood 8" Round 8" Round Of Hood Vent Holes Electrical 7 ¾" 5" x 16" Exhaust Opening 8" Transition Opening 9" 18" 550 T200 Dual Blower (Top View) 5" VP565 Standard Transition (Included) 16" Transition Installed (Side View) of Hood Connection Diagram (4-6 Widths) Blower Outlets Electrical (2) 12" Transition Opening 2 ¼ Above Top of Hood 7 ¾ Vent Holes of Hood 12" Round 12" Round 11 ¼" 2 ¼ 1 8" Round 8" Round 8" Round 1100 T400 Dual Blowers (Top View) VP564 Standard Transition (Included) Transition Installed (Side View) Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. 7) Remove the blower deck assembly by removing the 12 screws around the blower mounting plate. Unplug the electrical connector(s) and set the blower assembly aside, taking care not to damage the blower wheels. 8) Install an appropriate 1/2 UL listed electrical wire clamp through the electrical strap(s) on top of the hood deck. Install electrical wiring from the service panel to the hood location for each blower assembly. Consult the connection diagrams (above) for further details on electrical placement. Support the hood beneath the location where it will hang and feed the electrical wire(s) into the wire clamp(s). Tighten the wire clamp(s). Page 4

Model Volts Amps Hz RPM Installation Details Continued SP@0.0" Equivalent SP@0.1" SP@0.2" SP@0.3" Minimum Round Duct Size T200 Island Dual 115 4.0 60 1550 550 900 507 471 431 8" (50 in. 2 ) 6.0 T400 Island Cluster 115 7.5 60 1550 1100 1800 998 855 774 12" (13 in. 2 ) 6.4 Because the Magic Lung blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute () requirements and can deliver equivalent much more efficiently than other filtration systems. When comparing the Magic Lung with other blower units made by other manufacturers, use the Equivalent. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. 9) Raise the hood to its final position and attach it to the load-bearing framework in the ceiling using appropriate hardware or to the duct cover using the screws previously removed in Step 3. 10) From inside the hood, using UL listed wire nuts, attach the neutral wire(s) to the white lead(s), the hot wire(s) to the black lead(s), and the ground wire(s) to the green lead(s). Sones # Warning: Do not operate hood without proper ground connection. 11) Attach the transition to the blower deck assembly and seal with duct tape. The transition must fit inside the exhaust collar on the blower deck assembly. Reconnect the electrical connector(s). For assemblies with two connectors, connect the right harness to the front connector and the left harness to the back connector. While taking care to properly align the duct connection between the transition and the duct in the ceiling, reinstall the blower deck assembly into the hood using the 12 screws previously removed in Step 7. 12) Replace the blower housings and the blower shields. Make sure that the dampers open and close smoothly. 13) Refer to Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions to ensure they are operating properly. Page 5

VENTING WALL LOUVER WALL LOUVER WALL LOUVER ACCESSORIES RECTANGULAR WALL LOUVER 8 5 Back View 1 ½ Flange Back View 1 ½ Flange 13 13 Back View 1 ½ Flange 8 ½ 1 ½ FLANGE 2 FLANGE VP526 VP527 VP528 Round Round Round (MAXIMUM 4/12 PITCH) VP554 Round (MAXIMUM 4/12 PITCH) VP555 Round (MINIMUM 4/12 PITCH) VP538 VP560 x 8 ½ x (MINIMUM 4/12 PITCH) 6 ½ 22 ½ 6 ½ 22 ½ 20 ¾ 20 ¾ VP539 Round VP540 Round VP541 Round ADJUSTABLE ELBOW VP513-8 ½ VP514-9 9 1 VP515-10 5 VP552 VP553 Round Round BACK/SIDE VENT ELBOW 8 ½ VP539-HP Round VP540-HP Round VP541-HP Round x BACK VENT ELBOW 14 4 ¼ VP552-HP VP553-HP x TO TRANSITION Round Round 7 ½ VP513 Round VP514 Round VP515 Round MULTI-BLOWER TRANSITION Round 1 VP561 to x 8 ½ M1200 STANDARD TRANSITION VP559 x STANDARD ISLAND TRANSITION VP521 x to CLUSTER BLOWER TRANSITION VP562-17 ½ VP563-16 ½ 9 9 11 ¼ VP562-2 VP563-30 ½ VP562 VP563 & to & to 21 VP566 21 x to 1 5 VP565 5 x 1 to 18 ½ VP564 & to OFFSET L & R TRANSITION FOR ISLAND BLOWERS SIDE VENT TRANSITION L & R FOR ISLAND BLOWERS 19 OFFSET KIT - ROUND OFFSET KIT - RECTANGULAR VP542 VP543 5 1 Top Left Top Right VP544 VP545 1 5 Left Side Right Side VP529 1 Rnd to Rnd 1 VP550 Rnd to x Y TRANSITION ROUND DUCT PIPE RECTANGULAR DUCT PIPE RECTANGULAR DUCT PIPE 1 3 30 1 24 8 ½ VP517 VP518 VP551 & to & to & to VP500 VP501 VP502 Round Round Round VP504 VP505 VP506 x x x 1 VP507 x 8 ½ Page 6