MODELS 2 & 4 Top Conduit Linears

Similar documents
MODELS. 2 & 4 Low Profile Linears

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

FOR USE WITH MODEL NUMBERS:

Operating Instructions

SAVE THESE INSTRUCTIONS!!

Operating Instructions

Operation/Installation Instructions

Operating Instructions

Operating Instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SynergEX Panelboards for Hazardous Locations

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION MANUAL

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

LAL SERIES LED LUMINAIRE

INSTALLATION INSTRUCTION MANUAL

Installation Documentation ID-2663

Installation and Maintenance Manual (2014)

LED IMPORTANT SAFETY INSTRUCTIONS

Spun Bay Installation Standard Version (non dimmable), Hook Mount

IMPORTANT SAFEGUARDS

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

GE Lighting. Heavy Industrial High Bay & Low Bay Lighting. (ABR1 - Series) imagination at work

Installation and Operation Instructions 10/04/13

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

LED IMPORTANT SAFETY INSTRUCTIONS

MaxLite StaxMax LED Flood Lights

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Installation Instructions for Appleton Mercmaster LED Luminaire

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Rental Industry Safety Tester Safe Check 5s

MOONRING 1.5 MOONRING 3

SBP2 Pendant Pushbutton Stations Installation Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

ACE Variable Frequency Drive System

L-K INDUSTRIES. Criterion Water Bath

I. Pendant Mount Installation

VSQ SERIES 30 AMP INTERLOCKED SWITCHED RECEPTACLES

MaxLite LED Linear HighBay Fixtures

HBDBM High Bay Series

60 Watt Industrial LED Low Bay Light

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

Lumination TM LED Luminaires LAL Series - Continuous Run Option

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Installation Instruction ALG Series LED Area Light Version: 3.1

IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions Central Battery Units

MaxLite LED UTILITY WRAP FIXTURES

Thermocouple Thermometer Models

IsoLED FLEX I CUSTOMER MANUAL

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

ILED Aquarius Illuminated Windsock. User Manual

SAVE THESE INSTRUCTIONS

When using electrical equipment, basic safety precautions should always be followed including the following:

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

General Installation Instructions LED

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

CT-930 MANUAL HYDRAULIC COMPRESSION TOOL TABLE OF CONTENTS

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

INSTALLATION INSTRUCTIONS

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

LED IMPORTANT SAFETY INSTRUCTIONS

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

INSTALLATION GUIDE AND USER MANUAL

INSTRUCTION SHEET. Installation Instructions for Mercmaster LED Luminaire. Applications. Agency Ratings. Product Safety

Instruction/Installation Manual

LED UFO High Bay with j-box Installation Instruction

Installation manual. For professional use only

M-3025CB-AV Fuel Pump

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

SafeSite LED Based Signaling for Hazardous Locations

Patent Pending. SafeSite LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations

Switching DC Power Supply

Direct Communication Module

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Applications. Illustrated Features

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instruction

VR44-MU-xxx-8yy-xxxxA

Dialight LED Area Light. Technical Specification Sheet - CE

High Bay Luminaire Series

LED Emergency Luminaires

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

DuroSite LED Area Light V AC, 24-48V DC, V AC Battery Backup

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Specification Grade Contemporary Wall Mount/Technical Installation Data

General Installation Instructions LED

INSTALLATION NOTES: nbeckon-26

Transcription:

INSTALLATION AND MAINTENANCE MANUAL SAFESITE AND DUROSITE LED LINEAR FIXTURE Document No: 9100-127-1885-99 Rev E December, 2016 MODELS 2 & 4 Top Conduit Linears These instructions contain important safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect installation, operation or maintenance 1: Introduction This Linear LED light is designed for illumination of industrial locations. It uses the latest in solid state lighting technology for long life, low maintenance, and high efficiency. The unique optical design focuses light downward to where it is needed, giving improved efficiency over a conventional HID luminaire. An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from any nominal 100V-277V, 50/60Hz AC supply without any variation in light output. Note: Save these instructions for future reference.

Non-Hazardous Models (see product label) Models SUITABLE FOR WET LOCATIONS in unclassified locations: Temperature Code: T5 for 2' model, T5 for 4' model Ambient Temperature Range: -40C to +65C Class I Models (see product label) Models SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations: Class I, Division 2, Groups A, B, C, D Ambient Temperature Range: -40C to +65C (T4A) Ambient Temperature Range: -40C to +45C (T5) Class II Models (see product label) SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations: Class I, Division 2, Groups A, B, C and D Class II, Division 1, Groups E, F and G Class II, Division 2, Groups F and G Class III Ambient Temperature Range: -40C to +65C (T4A) Ambient Temperature Range: -40C to +45C (T5) 2: Installation Warnings for all models For supply connections use wire rated for at least 90 º C To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. To avoid electric shock: Be certain electrical power is OFF before and during installation and maintenance. Luminaire must be connected to a wiring system with an equipment-grounding conductor. DO NOT let power cord touch hot surfaces DO NOT mount near gas or electric heaters Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommend by the manufacture may cause an unsafe condition DO NOT use this equipment for other than it s intended use Page 2 of 7

The technical data indicated on the Luminaire are to be observed. Changes to the design and modifications of the Luminaire are not permitted Only genuine Dialight replacement parts are to be used when unforeseen maintenance is required. Consult factory at www.dialight.com or authorized representative as required. Warnings for Class I & II Models To avoid explosion: Make sure the supply voltage is within the luminaries voltage rating. Ensure the marked T Rating is less than the ignition temperature of the Hazardous Atmosphere. Do not operate in ambient temperatures above those indicated on the Luminaire nameplate. Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. WARNING - EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. AVERTISSEMENT - RISQUE D'EXPLOSION - substitution de composants peut nuire à la conformité Classe I, Division 2. To avoid explosion (Continued): EXPLOSION HAZARD- DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DECONNECTER L'EQUIPEMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX Conduit thru Mount (Figure 2) Installation Steps: For maximum long term reliability and light output, the light must be installed in free air. o The Linear fixture design incorporates an over-temperature control circuit that reduces input power should internal temperatures reach a maximum level. In this event, light output may be reduced. The Linear fixture is threaded for 3/4 NPT, at the center and each end of the Power Supply Housing s Junction Box Section, in order to be assembled to conduit. o Remove the 3/4 NPT pipe plugs and attach conduit as shown in figure 2. Use conductive pipe sealant for all fittings and conduit. o If there is moisture present, or chance of it, in the conduit system then necessary precautions should be taken by the installer to prevent the moisture from entering thru the cable or conduit and entering the fixture. Failure to comply with the above could void factory warranties. o Fixture is factory wired with LINE, NEUTRAL and GROUND leads. Remove the Power Supply Junction Box Cover, which has captive screws, to attach incoming power to the white (Neutral) wire, black (Line) and green (Ground) wire leads with wire nuts. Ensure that Page 3 of 7

o Document No: 9100-127-1885-99 Rev E the o-ring is properly seated in the groove; reattach the Cover. Tighten all screws to 15 in/lbs (1.75NewtonM s) Restore power and verify operation. ¾ NPT Plug in center Figure 2. JUNCTION BOX COVER WITH CAPTIVE SCREWS Conduit through mounting Conduit Pendant Mount (Figure 3) Installation Steps: For maximum long term reliability and light output, the light must be installed in free air. o The Linear fixture design incorporates an over-temperature control circuit that reduces input power should internal temperatures reach a maximum level. In this event, light output may be reduced. o The Linear fixture is threaded for 3/4 NPT, at the center of the Power Supply Housing s Junction Box area in order to be assembled to conduit. Each end has a factory installed 3/4 NPT pipe plug installed. o Attach conduit as shown in figure 3. Use conductive pipe sealant for all fittings and conduit. o WARNING :If there is moisture present, or chance of it, in the conduit system then necessary precautions should be taken by the installer to prevent the moisture from entering thru the cable or conduit and entering the fixture. Failure to comply with the above could void factory warranties. o Fixture is factory wired with LINE, NEUTRAL and GROUND leads. Remove the Power Supply Junction Box Cover, which has captive screws, to attach incoming power to the white (Neutral) wire, black (Line) and green (Ground) wire leads with wire nuts. Ensure that the o-ring is properly seated in the groove; reattach the Cover. Tighten all screws to 15 in/lbs (1.75NewtonM s) o Restore power and verify operation. Page 4 of 7

Figure 3. Pendant Mount ¾ NPT Plugs in both ends 3: Maintenance To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance. No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty. 1) We suggest performing visual, mechanical and electrical inspections on a regular basis. We suggest routine checks to be made on a yearly basis. Frequency of use and environment should determine this. It is recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B: Recommended Practice for Electrical Equipment. 2) If the lens (Figure 4 below) requires periodical cleaning to ensure continued photometric performance. Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap and water. 3) Inspect the outside of the Luminaire housing to ensure that they are free of any obstructions or contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed. 4) Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. 5) NOTE: Screws, other than the Junction Box area, are factory torqued and should not be tampered with during installation or maintenance. Page 5 of 7

Polycarbonate Lenses Figure 4. All Models Nominal AC Supply Voltage Specifications 100-277VAC, 50-60Hz Power consumption: 2 version 32W nominal 4 version 64W nominal Input Current: (Nominal).33Amps @100Vac (2 foot).66amps @100Vac (4 foot).12amps @277Vac (2 foot).24amps @277Vac (4 foot) Power factor >0.9 ATHD <20% Dimensions (L x W x H) See Figure 5. Weight 8 lbs [3.62 kg] (2 ) 11 lbs [4.98 kg] (4 ), Class I & II Models (see product label) Operating temperature range -40 F to +149 F [-40 C to +65 C] T4A @ 149 F [65 C] -40 F to +113 F [-40 C to +45 C] T5 @ 113 F [45 C] Intertek Certified to UL-844, 1598, 1598A, 1012 CSA C22.2 No. 137-M1981 CSA C22.2 No. 250 Non-Hazardous Models (see product label) Operating temperature range -40 F to +149 F [-40 C to +65 C] T5 @ 149 F [65 C] Intertek Certified to UL-844 & C22.2 No.137 Page 6 of 7

Figure 5. DIMENSIONS ARE FOR REFERENCE ONLY: Chemical Compatibility Guide Footnote on Chemical Compatibility Guide: The chemical compatibility data referenced in this manual was supplied by the raw material manufacturers and is intended as a general guide. The data represents the basic material properties and does not necessarily represent the performance of the final product due to manufacturing process and design variations for each final product. Chemical compatibility is highly dependent on concentration, temperature, humidity, and other environmental conditions and therefore the customer assumes responsibility for evaluation of gaseous or direct contact chemical compatibility at their site prior to product installation. For general guidelines describing chemical compatibility, visit us at: www.dialight.com/pubs/mdtfchemrflx001.pdf All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof is not guaranteed. In accordance with Dialight Corporation Terms and Conditions of Sale, and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith Page 7 of 7