Series TFXL ULTRASONIC CLAMP-ON FLOW METER DIMENSIONAL SPECIFICATIONS PRODUCT INSTALLATION

Similar documents
HTTF Transit Time Ultrasonic Flow Meter

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

UTM10 Series Ultrasonic Transit-time Flowmeters

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

Model DFX Doppler ultrasonic flow meter

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

MODEL TFXL ULTRASONIC FLOW METER. Installation and Operating Instructions

TRANSIT TIME FLOW METERS

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow Model 2200 Installation and Operation Guide B

Time Delta S Fixed Transit-Time Flow Meter System

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

Transmitting Transducer. Gas/Air Velocity Range:

Spiraflo Steam flowmeters

Product Data Sheet. Positive Displacement Flow Meter B1750 DESCRIPTION

Your Global Source for Today s Most Popular Solenoid Valves

Inline Ultrasonic Flowmeter

Product Data Sheet. Coriolis Flow Meter RCT1000 DESCRIPTION APPLICATIONS MAINTENANCE OPERATION FLUID DIAGNOSTICS ADVANTAGES

Hydro-Flow Model 3100

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Principle of Operation

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

TURBINE FLOW METER SELECTION GUIDE

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

Hydro-Flow Model 2300 Installation and Operation Guide B

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Product Data Sheet. Turbine Flow Meter. B16D Series FloClean Sanitary DESCRIPTION INSTALLATION REPAIR KITS

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Bourdon Tube Type Differential Pressure Gauge & Switches Model 109

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

EM... The Quiet Alternative

Product Data Sheet. Flow Monitor. B2800 Series DESCRIPTION OPERATION FEATURES

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Range of Ultrasonic Flowmeters.

Flow Measurement SITRANS F US Clamp-on

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

NC State University Design and Construction Guidelines Division 23 Energy Management

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

PRESSURE INDEPENDENT CONTROL VALVE

Model 1100 Turbine Flow Meter

SV321 & SV Way Normally Closed and Normally Open Pilot Operated Solenoid Valves

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Mid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

G2 Industrial Grade Meters

DW PADDLE-BELLOWS FLOWMETER & SWITCH

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

F-2600 SERIES INLINE VORTEX FLOW METER

DW PADDLE-BELLOWS FLOWMETER & SWITCH

imag 4700 SERIES FLANGED MAGMETER

ROTORK FAIRCHILD MODEL T7500 LOW PRESSURE TRANSDUCER Installation, Operation and Maintenance Instructions

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

accqpulse Velocity Profiler Sensor Installation Guide

Vantage 6000 Portable Ultrasonic Flow Meter

Compact / Lightweight 2 Port Solenoid Valve

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

TM 301 TM 308 In-Line Torque Transducers

Ultra Mag SUBMITTAL PACKAGE

Series DFXD. Doppler Ultrasonic Flow Meter. Operations & Maintenance Manual REV 8/08

QUANTUM. Quantum Low Power Control Monitor LOW POWER CONTROL MONITOR. " Design Features

F-2500 SERIES VORTEX METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

SIGNET Vortex Flow Sensors ENGLISH

F-2700 SERIES INSERTION VORTEX FLOW METER

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

F-1500 SERIES INSERTION TURBINE FLOW METER

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

Paddle-wheel flow controller for On/Off control

Signet 7000/7001 Vortex Flow Sensors * *

DW PADDLE-BELLOWS FLOWMETER & SWITCH

SOLENOID VALVES direct operated core disc 1/4

Electronic Temperature Control & Bulb Well Assembly (AC)

ATT Series Adjustable PIC Valves 2 Way 1/2-1-1/2 ATT - AutoTouch Terminal

M3500 Industrial Pressure Transmitter

INLINE fitting with paddle-wheel for flow measurement

Portable Ultrasonic Flow Measuring System prosonic flow 92

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

MODEL 1100 TURBINE FLOW METER

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

RUN ACCUM. TOTAL STOP BAT LOW HIGH

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

! WARNING. Series LPC-2000 General Purpose Liquid Level Controls. Installation & Maintenance Instructions MM-106 (B)

SIGNET 7002 Vortex Flow Sensor ENGLISH

Propeller Meters. Flow measurement solutions for water and wastewater

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

EASZ-10P Operating Instructions

Transcription:

Series PROUT INSTLLTION Series IMENSIONL SPEIFITIONS MEHNIL IMENSIONS: INHES (MM) Installation onsiderations 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight pipe diameters upstream and 5 pipe diameters downstream with no flow disturbances. 2. pply couplant grease to the two surfaces of the transducers that contact the pipe. 3. Mount the flow meter or remote transducers onto the pipe and secure. On horizontal pipe, transducer mounting location should be approximately -degrees on the side of the pipe. On vertical pipes with upward flow, radial orientation does not matter. 4. onnect and apply power. 5. onnect the 4-20m, frequency or both outputs to the monitoring system. coustic ouplant pplication Size Material Measuring Range ULTRSONI LMP-ON METER.875 (22.2) I onduit hole Integral Mount 3/4" Flow Meter Mounting Orientation 2.57 (65.3) The Series ultrasonic flow meter clamps onto the outside of a pipe and does not contact the internal liquid. This advanced product provides instantaneous rate and accumulated flows along with 4-20m and pulse outputs. Inherent advantages over competitive technologies include ease of installation, immunity to suspended solids and gas pockets, and a large, bi-directional measuring range. In addition, the non-contact design eliminates any fluid compatibility issues. The is housed in an enclosure suitable for outdoor mounting and is available with or without a local display. ompact integral mount systems can accommodate pipes 2 inches [50 mm] and smaller. For additional flexibility, remote mount systems are available for pipe sizes 1/2 inch [12 mm] and higher. software utility is available for customer configuration and in-field calibration. 1" 10 1-1/4" U-olt onnections (NSI & opper 2 inch Models) 11" Series 5 1- Remote Mount - Small 2" Vertical Mount 5 Flow Meter Transducer can be Mounted in any Orientation * Varies due to U-bolt configuration Remote System 7.01 (178) 10 Remote Mount - Large 2.95 (74.9).21 (5.3) I 2 Mounting holes 3.00 (76.2) MIN learance FETURES TTS U-olt onnections (NSI & opper 2 inch Models) 2.75 (69.8) Remote Large Transducer Mounting Orientation TTS TTN.875 (22.2) I 2 onduit holes I V I S I O N O F R I N E F E E R T E I N. 8635 Washington ve. Tel: 262.639.6770 Fax: 262.639.2267 www.dynasonics.com Head-on View of FORM 03/05 7.9375" UltraLink software utility allows configuration, calibration and troubleshooting of the meter. Non-invasive system allows solids to pass through the pipe with no effect on meter. Y-strainers or filtering devices are not needed. Series is a bi-directional flow measurement system. Multiple totalizers simultaneously operate to measure forward total, reverse total and net total. Greater accuracy can be attained in applications with high levels of entrained gases. The Series will automatically correct displayed flow rates and electronic outputs. esigned to replace mechanical flow meters in applications where liquid conditions tend to damage or impede mechanical flow meter operation. No maintenance is required. irect interface is provided to data collection systems via 4-20m output and either TTL - pulse or simulated turbine meter outputs that are proportional to fluid flow rate. Series provides easy and low cost installation by clamping on the outside of existing piping systems. Series can be used on applications such as well water and other liquids with moderate amounts of suspended solids or aeration. Racine, WI 53406-3738 US 800.535.3569 North merica 800.732.8354 North merica I V I S I O N O F R I N E F E E R T E I N.

OPERTING PRINIPLE Transit time flow meters utilize two transducers which function as both ultrasonic transmitters and receivers. The flow meters operate by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers. The burst is first transmitted in the direction of fluid flow and then against fluid flow. Since sound energy in a moving liquid is carried faster when it travels in the direction of fluid flow (downstream) than it does when it travels against fluid flow (upstream), a differential in the times of flight will occur. The sound s time of flight is accurately measured in both directions and the difference in time of flight calculated. The liquid velocity (V) inside the pipe can be related to the difference in time of flight (dt) through the following equation: V = K**dt, where K is a constant and is the distance between the transducers. PRT NUMER ONSTRUTION Series Reflect-Mode onfiguration Transit Time - to 2" [12mm to 50mm] isplay Options 1) No display-s enclosure 2) Rate & Totalizer display- S enclosure 3) No display -polycarbonate enclosure 4) Rate & Totalizer displaypolycarbonate enclosure 1 N N Output 1) 4-20 m and Pulse onnector Options N) 1 /2 inch onduit Hole ) Water-tight able lamp ) ircular MIL-style onnector ) 1 /2 inch Flexible onduit onnector Size ) 1 /2 inch NSI ) 3 /4 inch NSI ) 1 inch NSI ) 1 1 /4 inch NSI E) 1 1 /2 inch NSI F) 2 inch NSI G) 1 /2 inch opper H) 3 /4 inch opper I ) 1 inch opper J ) 1 1 /4 inch opper K ) 1 1 /2 inch opper L ) 2 inch opper M ) 1 /2 inch Tubing N ) 3 /4 inch Tubing P ) 1 inch Tubing Q ) 1 1 /4 inch Tubing R ) 1 1 /2 inch Tubing S ) 2 inch Tubing Remote System - and higher [12mm and higher] ( system consists of one part number and a choice of one large or small pipe transducer part number.) System Size X) Large Y) Small 1- Select Options from Table above N N Large Transducer -2" and higher [50mm and higher] T T N Type N) Standard (PV, Ultem ) able Length onduit Type N) None are RG59 able ) Flexible armored onduit Length 000) 0 feet (0 m) ccessories Part Number P able w/ultralink software 010-0204-001 90-240 V Power Supply 005-2502-005 Location N) Ordinary rea F ) Intrinsically Safe (TTN only) Nominal Size ) 1 /2 inch F ) 3 /4 inch G ) 1 inch H ) 1 1 /4 inch J ) 1 1 /2 inch L ) 2 inch Type P ) NSI ) opper T ) Tubing Small Transducer- to 2" [12mm to 50mm] T T S able Length onduit Type N) None are RG59 able ) Flexible armored onduit Length 000) 0 feet (0 m) Ultem is a registered trademark of General Electric ompany.

SPEIFITION Series ESRIPTION SPEIFITION Liquid Types Power Requirements 11-30 V @ 0.25 Velocity Inputs/Outputs isplay Units mbient Temperature Liquid Temperature Enclosure Transducer Type Sizes Materials ccuracy Response Time Protection pprovals UltraLink Utility Most clean liquids or liquids containing moderate amounts of suspended solids or aeration. 0.1 to 40 FPS [0.03 to 12.4 MPS] 4-20m Output (standard output) Resolution Power Insertion loss Loop impedance Isolation 12-bit for all outputs Source 5V maximum 900 Ohms maximum Turbine Frequency Output/TTL -Pulse Output Switch selectable Type mplitude Frequency range an share ground common with power supply isolated from piping system Non-ground referenced / Ground referenced square wave 100mVpp minimum / 5V 0-1,000Hz uty cycle 50% ±10% Type 2 line x 8 character L; Top row: 0.7 [18mm] tall, 7-segment; ottom row: 0.35 [9mm] tall, 14-segment Rate 8 maximum rate digits, lead zero blanking Total 8 maximum totalizer digits, exponential multipliers from 1 to +6 Engineering Units: Feet, gallons, ft 3, million-gal, barrels (liquor & oil), acre-feet, lbs, meters, m 3, liters, million-liters, kg Rate Units: sec, min, hr, day General Purpose: 0 to +185 F [-20 to +85 ]; Hazardous Locations: 0 to +105 F [-20 to +40 ] 0 to +185 F [-20 to +85 ] NEM 3 [Type 3] S or polycarbonate, PV, Ultem, brass or SS hardware, 3W x 6L x 2.5H inches [75W x 150L x 63L mm], pipe mount lamp-on, uses time of flight ultrasonic and higher arbon steel, stainless steel, copper, and plastic ±1% of reading at rates above 1 FPS [0.3 MPS]; ±0.01 FPS [.003 MPS] of reading at rates lower than 1 FPS [0.3 MPS] 0.3 to 30 seconds, adjustable Reverse-polarity, surge suppression General Requirements: NSI/IS 582.01 Hazardous Locations: NSI/IS 12.12.01 lass I iv 2, Groups & S 22.2 No. 213, E79-15-95 (3 & 4 models only) Windows based software utility, requires serial communication cable Windows 95, 98, 2000, and XP compatible TTN Transducer Standard: Ordinary rea Intrinsically Safe Option: General Requirements - 22.2. 142; UL 916 Hazardous Locations - 22.2 No. 157; UL 913: 2002 lass I iv 2, Groups & Windows is a registered trademark of Microsoft orp.

PPLITION T SHEET Series Job Name/Reference #: Name: ompany: ate: Title: E-Mail: ddress: ity: Zip / Postal: Telephone: State / Province: ountry: Fax: Liquid Type: Water Wastewater Oil Other Liquid omposition ( % volume, solids or aeration): Max. Liquid Temp: ºF/º Viscosity: Full during flow measurement: Yes No O.. : inches mm Schedule/lass: Material: Liner (if applicable): Type Thickness Length of straight pipe (in pipe diameters): Upstream ownstream Nearest obstruction (i.e. elbow, valve): Flow Range: Minimum Maximum Nominal Flow Units: GPM LPM Other isplay: None Rate / Total Power Requirement: / Output Requirements: None 4-20m Rate Pulse Environment: Indoor Outdoor Submersible Hazardous rea Other Requirements: It is recommended that a ynasonics application expert review new applications before ordering. Fill out the information noted above and fax to ynasonics at 262-639-2267. Please enclose contact information so ynasonics personnel may contact you regarding any additional questions.

Series PROUT INSTLLTION Series IMENSIONL SPEIFITIONS MEHNIL IMENSIONS: INHES (MM) Installation onsiderations 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight pipe diameters upstream and 5 pipe diameters downstream with no flow disturbances. 2. pply couplant grease to the two surfaces of the transducers that contact the pipe. 3. Mount the flow meter or remote transducers onto the pipe and secure. On horizontal pipe, transducer mounting location should be approximately -degrees on the side of the pipe. On vertical pipes with upward flow, radial orientation does not matter. 4. onnect and apply power. 5. onnect the 4-20m, frequency or both outputs to the monitoring system. coustic ouplant pplication Size Material Measuring Range ULTRSONI LMP-ON METER.875 (22.2) I onduit hole Integral Mount 3/4" Flow Meter Mounting Orientation 2.57 (65.3) The Series ultrasonic flow meter clamps onto the outside of a pipe and does not contact the internal liquid. This advanced product provides instantaneous rate and accumulated flows along with 4-20m and pulse outputs. Inherent advantages over competitive technologies include ease of installation, immunity to suspended solids and gas pockets, and a large, bi-directional measuring range. In addition, the non-contact design eliminates any fluid compatibility issues. The is housed in an enclosure suitable for outdoor mounting and is available with or without a local display. ompact integral mount systems can accommodate pipes 2 inches [50 mm] and smaller. For additional flexibility, remote mount systems are available for pipe sizes 1/2 inch [12 mm] and higher. software utility is available for customer configuration and in-field calibration. 1" 10 1-1/4" U-olt onnections (NSI & opper 2 inch Models) 11" Series 5 1- Remote Mount - Small 2" Vertical Mount 5 Flow Meter Transducer can be Mounted in any Orientation * Varies due to U-bolt configuration Remote System 7.01 (178) 10 Remote Mount - Large 2.95 (74.9).21 (5.3) I 2 Mounting holes 3.00 (76.2) MIN learance FETURES TTS U-olt onnections (NSI & opper 2 inch Models) 2.75 (69.8) Remote Large Transducer Mounting Orientation TTS TTN.875 (22.2) I 2 onduit holes I V I S I O N O F R I N E F E E R T E I N. 8635 Washington ve. Tel: 262.639.6770 Fax: 262.639.2267 www.dynasonics.com Head-on View of FORM 03/05 7.9375" UltraLink software utility allows configuration, calibration and troubleshooting of the meter. Non-invasive system allows solids to pass through the pipe with no effect on meter. Y-strainers or filtering devices are not needed. Series is a bi-directional flow measurement system. Multiple totalizers simultaneously operate to measure forward total, reverse total and net total. Greater accuracy can be attained in applications with high levels of entrained gases. The Series will automatically correct displayed flow rates and electronic outputs. esigned to replace mechanical flow meters in applications where liquid conditions tend to damage or impede mechanical flow meter operation. No maintenance is required. irect interface is provided to data collection systems via 4-20m output and either TTL - pulse or simulated turbine meter outputs that are proportional to fluid flow rate. Series provides easy and low cost installation by clamping on the outside of existing piping systems. Series can be used on applications such as well water and other liquids with moderate amounts of suspended solids or aeration. Racine, WI 53406-3738 US 800.535.3569 North merica 800.732.8354 North merica I V I S I O N O F R I N E F E E R T E I N.

Series PROUT INSTLLTION Series IMENSIONL SPEIFITIONS MEHNIL IMENSIONS: INHES (MM) Installation onsiderations 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight pipe diameters upstream and 5 pipe diameters downstream with no flow disturbances. 2. pply couplant grease to the two surfaces of the transducers that contact the pipe. 3. Mount the flow meter or remote transducers onto the pipe and secure. On horizontal pipe, transducer mounting location should be approximately -degrees on the side of the pipe. On vertical pipes with upward flow, radial orientation does not matter. 4. onnect and apply power. 5. onnect the 4-20m, frequency or both outputs to the monitoring system. coustic ouplant pplication Size Material Measuring Range ULTRSONI LMP-ON METER.875 (22.2) I onduit hole Integral Mount 3/4" Flow Meter Mounting Orientation 2.57 (65.3) The Series ultrasonic flow meter clamps onto the outside of a pipe and does not contact the internal liquid. This advanced product provides instantaneous rate and accumulated flows along with 4-20m and pulse outputs. Inherent advantages over competitive technologies include ease of installation, immunity to suspended solids and gas pockets, and a large, bi-directional measuring range. In addition, the non-contact design eliminates any fluid compatibility issues. The is housed in an enclosure suitable for outdoor mounting and is available with or without a local display. ompact integral mount systems can accommodate pipes 2 inches [50 mm] and smaller. For additional flexibility, remote mount systems are available for pipe sizes 1/2 inch [12 mm] and higher. software utility is available for customer configuration and in-field calibration. 1" 10 1-1/4" U-olt onnections (NSI & opper 2 inch Models) 11" Series 5 1- Remote Mount - Small 2" Vertical Mount 5 Flow Meter Transducer can be Mounted in any Orientation * Varies due to U-bolt configuration Remote System 7.01 (178) 10 Remote Mount - Large 2.95 (74.9).21 (5.3) I 2 Mounting holes 3.00 (76.2) MIN learance FETURES TTS U-olt onnections (NSI & opper 2 inch Models) 2.75 (69.8) Remote Large Transducer Mounting Orientation TTS TTN.875 (22.2) I 2 onduit holes I V I S I O N O F R I N E F E E R T E I N. 8635 Washington ve. Tel: 262.639.6770 Fax: 262.639.2267 www.dynasonics.com Head-on View of FORM 03/05 7.9375" UltraLink software utility allows configuration, calibration and troubleshooting of the meter. Non-invasive system allows solids to pass through the pipe with no effect on meter. Y-strainers or filtering devices are not needed. Series is a bi-directional flow measurement system. Multiple totalizers simultaneously operate to measure forward total, reverse total and net total. Greater accuracy can be attained in applications with high levels of entrained gases. The Series will automatically correct displayed flow rates and electronic outputs. esigned to replace mechanical flow meters in applications where liquid conditions tend to damage or impede mechanical flow meter operation. No maintenance is required. irect interface is provided to data collection systems via 4-20m output and either TTL - pulse or simulated turbine meter outputs that are proportional to fluid flow rate. Series provides easy and low cost installation by clamping on the outside of existing piping systems. Series can be used on applications such as well water and other liquids with moderate amounts of suspended solids or aeration. Racine, WI 53406-3738 US 800.535.3569 North merica 800.732.8354 North merica I V I S I O N O F R I N E F E E R T E I N.