INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Similar documents
INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Viking Installation Guide

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

! FOR DOMESTIC COOKING ONLY!

Hood. warning. warning. caution

Pro Island Ventilation Hoods

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

WhispAire Range Hood Quiet Hood

Installation Instructions

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Designer Wall Range Hood Installation. Installation Tutorial Video

NUTONE RANGE HOOD NTM SERIES

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Type of Motor & Blower

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

Self-Cleaning Range Hoods

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

Installation Instructions

! FOR DOMESTIC COOKING ONLY!!

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

www. TheRangeHoodStore.com

WhispAire Range Hood Quiet Hood

Viking Installation Guide

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

Installation. Professional Indoor & Outdoor Hoods

FADE Series Wall Axial Fans

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-XHD SERIES. TMI, LLC Managing Environments

All (-4) Models 390CFM Code Compliant

Viking Installation Guide

ISLAND RANGE HOOD SPECIFICATIONS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

KEES, INC. BALANCING MANUAL

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

Model ND-2 Specification

Viking Installation Guide

IMPORTANT SAFETY INSTRUCTIONS

HP190SL Series Slimline Radon Fans

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

Safety & Installation Instructions

ceiling & inline/cabinet ventilators

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

Viking Installation Guide

CEILING & INLINE/CABINET VENTILATORS

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

ISLAND INSTALLATION WALL INSTALLATION

PRODUCT INDEX PRODUCT INDEX. Item Page Item Page Item Page

Multi-Port Centrifugal Fans for Round Duct

LE MODELS: SHIPPING, RIGGING, LIFTING, ASSEMBLY MANUAL

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

NTM SERIES INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER. HOMEOWNER: OPERATION AND CARE INFORMATION ON PAGES 9-10.

VENT FLASHINGS GALVANIZED STEEL

Pro and Designer Series Ventilation

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

MICRO-AIR DUST COLLECTOR Installation and Operation Manual MODEL RP6-2, RP-3, RP8-2 & RP-3

Installation Instructions

MODERN-AIRE. For the professional or the everyday gourmet, Modern-Aire Ventilating. Range Hoods

INSTALLATION INSTRUCTIONS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

IMPORTANT SAFETY INSTRUCTIONS

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

INSTALLATION INSTRUCTIONS

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Use, Care, and Installation Guide

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Transcription:

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally during installation. B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. C. Ducted fans must always be vented to the outdoors. D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to a maximum of 15 per 100 square feet of occupiable space, unless a back drafting test is performed or make-up air is provided. Consult a local HVAC engineer for make-up air evaluation. Page 1 US

Ducting Do s and Don ts General Requirements Observe local codes regarding special duct requirements and placement of duct against combustibles. Using Vent-A-Hood transitions (back page) will ensure proper efficiency. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Where possible, seal joints with duct tape. The hood must be ducted to the outdoors without restrictions. Blower Requirements The single blower unit (M600) requires round duct or equivalent (28 square inches), and the dual blower unit (M1200) requires round duct or equivalent (79 square inches). Blower Combined Duct Dize Sq. Inch Area Vent-A-Hood Transition Single (M600) 6" round or equivalent 28 sq. in. N/A Dual (M1200) 10" round or equivalent 79 sq. in. VP566 (Included) Ducting Requirements NEVER reduce the duct size. Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Termination Requirements Airflow must not be restricted at the end of the duct run. A wall louver or roof jack is required for each duct run. Every wall louver or roof jack must include a gravity damper to prevent back drafts. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. YES Smooth Duct Smooth Gradual Turn Proper Combining of Two Ducts NO Flexible Duct Sharp Angled Turns Page 2 Improper Combining of Two Ducts

Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) When installing a wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 30 above the cooking surface for optimum performance. 3) Consult the connection diagrams below for further details on exhaust outlet placement. Install the duct from the outside of the home down to the exhaust outlet on the hood. The end of the duct should extend to the top of the hood for the M600 blower or 1" past the top of the transition for the M1200 blower. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is included on the back page of this instruction sheet. Transition heights are as follows: Single Blower (M600): Dual Blower (M1200): round duct will connect directly to the top of the hood. Included round transition (VP566) is 9 tall. M600 Connection Diagram M1200 Connection Diagram 6" Round Electrical Single Blower (Top View) 10" Round Dual Blower (Top View) Electrical Page 3

Installation Details Continued 4) Remove the hood from its packaging and place the back of the hood on the floor or countertop in front of the wall where it will hang. 5) Remove the cardboard filter retaining clip. Sharply push the front of the filter (knob end) into the hood. Raise the back of the filter from the filter rest and remove the filter through the hood opening. Repeat for each filter. Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. 6) Hoods are shipped from the factory with the junction box mounted for the M1200 double blower configuration. Remove the junction box cover. If the M600 single blower will be used, relocate the junction box and ground strap to the offset location. Install an appropriate 1/2 UL listed electrical wire clamp through the electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location. Consult the connection diagrams (on previous page) for further details on electrical placement. Model Volts Amps* Hz SP@0.0" SP@0.1" SP@0.25" SP@0.5" SP@0.75" Minimum Round Duct Size M600 Single 115 5.0 60 630 625 615 600 580 6" (28 in. 2 ) M1200 Dual 115 10.0 60 1035 1015 1000 955 915 10" (79 in. 2 ) * Add 0.5 amp for each halogen light. 2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54"-66" 7) For M600 single blower installation, skip to Step 8. Install the 10" transition (VP566, included) to the top of the hood with the screws provided. Seal the base of the transition to the hood with duct tape. 8) If using a duct cover, carefully remove the knockouts from the top four corners of the hood. Remove the duct cover from its packaging and remove the mounting screws from the base of the duct cover. Place the duct cover on the top of the hood and secure it through the knockout openings using the mounting screws previously removed. 9) Lift the hood (and duct cover assembly) to the location on the wall where it will be installed. Lightly mark the wall with a short, horizontal mark along the bottom edge of the hood. Remove the hood (and duct cover assembly) from the wall. 10) On the back side of the hood, measure the distance between the bottom edge of the hood and the top edge of the wood mounting strip. Measure this distance above the horizontal mark made in Step 9 and lightly mark the wall with a level, horizontal line. Measure where the center (left to right) of the hood will be and mark the upper, horizontal line on the wall with a short, vertical centerline. 11) Remove the screws inside the top of the back of the hood that retain the wood strip that is recessed in the mounting channel. Remove the wood mounting strip from the back of the hood and place the top edge of the strip on the upper, level, horizontal line on the wall. Referencing the vertical centerline from Step 10, place the mounting strip on the wall so it is centered (left to right) in the space where the hood will be located. Drill pilot holes in the strip to prevent splitting. Using proper hardware, attach the mounting strip to the two outermost available wall studs. For hoods wider than 36", attach to additional wall studs. 12) Hang the hood on the mounting strip by first aligning the ducting (M1200 blower only) and then aligning the channel at the top of the back of the hood over the wood mounting strip on the wall. While holding the hood in place, mark locations on the mounting strip through the two mounting holes in the channel at the top of the hood. Remove the hood and drill 3/32" pilot holes at the center of the marks in the wood strip to prevent splitting. 13) Insert the electrical wire from the service panel 6" past the electrical wire clamp on the junction box. Tighten the wire clamp. While securing the slack in the wire, lift the hood up to the wall and hang the hood on the mounting strip, taking care to properly align the duct connection (M1200 blower). Secure the hood to the mounting strip by installing the screws (previously removed from the strip in Step 11) into the pilot holes drilled in Step 12. Page 4

Installation Details Continued 14) From inside the hood, using UL listed wire nuts, attach the "neutral" wire to the white lead, the "hot" wire to the black lead, and the ground wire to the green lead inside the junction box. Replace the junction box cover. Warning: Do not operate hood without proper ground connection. 15) Raise the blower plate into the hood first aligning the ducting (M600 blower only) and then aligning the blower mounting studs to the holes in the blower plate. Secure the blower assembly with the nuts provided. Connect the motor harness to the socket next to the power cord on the reverse side of the control housing. 16) To install the baffle filter, hold the filter with the knob facing down and toward the front of the hood. Insert the back of the filter into the back filter channel with enough force to compress the filter spring. Raise the front of the filter inline with the front filter channel and slowly release the spring force. To remove the baffle filter, push the filter knob toward the back filter channel to compress the filter spring. Lower the front of the filter below the front filter channel and slowly release the spring force. 17) Refer to the Owner and Maintenance Guide for proper hood operation. Test all blower and light functions to ensure they are operating properly. Page 5

VENTING WALL LOUVER WALL LOUVER WALL LOUVER ACCESSORIES RECTANGULAR WALL LOUVER 8 5 Back View 1 ½ Flange Back View 1 ½ Flange 13 13 Back View 1 ½ Flange 8 ½ 1 ½ FLANGE 2 FLANGE VP526 VP527 VP528 Round Round Round (MAXIMUM 4/12 PITCH) VP554 Round (MAXIMUM 4/12 PITCH) VP555 Round (MINIMUM 4/12 PITCH) VP538 VP560 x 8 ½ x (MINIMUM 4/12 PITCH) 6 ½ 22 ½ 10 ½ 6 ½ 22 ½ 10 ½ 20 ¾ 20 ¾ VP539 Round VP540 Round VP541 Round ADJUSTABLE ELBOW VP513-8 ½ VP514-9 9 1 VP515-10 5 VP552 VP553 Round Round BACK/SIDE VENT ELBOW 8 ½ VP539-HP Round VP540-HP Round VP541-HP Round x BACK VENT ELBOW 14 4 ¼ VP552-HP VP553-HP x TO TRANSITION Round Round 7 ½ VP513 Round VP514 Round VP515 Round MULTI-BLOWER TRANSITION Round 1 VP561 to x 8 ½ M1200 STANDARD TRANSITION VP559 x STANDARD ISLAND TRANSITION VP521 x to CLUSTER BLOWER TRANSITION VP562-17 ½ VP563-16 ½ 9 9 11 ¼ VP562-2 VP563-30 ½ VP562 VP563 & to & to 21 VP566 21 x to 1 5 VP565 5 x 1 to 18 ½ VP564 & to OFFSET L & R TRANSITION FOR ISLAND BLOWERS SIDE VENT TRANSITION L & R FOR ISLAND BLOWERS 19 OFFSET KIT - ROUND OFFSET KIT - RECTANGULAR 10 ½ VP542 VP543 5 1 Top Left Top Right VP544 VP545 1 5 Left Side Right Side VP529 1 Rnd to Rnd 1 VP550 Rnd to x Y TRANSITION ROUND DUCT PIPE RECTANGULAR DUCT PIPE RECTANGULAR DUCT PIPE 1 3 30 1 24 8 ½ VP517 VP518 VP551 & to & to & to VP500 VP501 VP502 Round Round Round VP504 VP505 VP506 x x x 1 VP507 x 8 ½ Page 6