Dry Block and Liquid Bath Temperature Calibrator Series

Similar documents
Dry Block and Liquid Bath Temperature Calibrator Series

Temperature multi-function calibrator Model CTM

ADTS550F. Your touch, our technology. GE Measurement & Control. (ADTS552F, ADTS553F, ADTS554F) Wireless ADTS500 Series Easy-to-Use Pitot Static Tester

MTC Series. Marine Temperature Calibrator

ADTS542F. Your touch, our technology. GE Oil & Gas. Wireless ADTS500 Series Easy-to-Use Pitot Static Tester. Features

ADTS542F. Your touch, our technology. Wireless ADTS500 Series Easy-to-Use Pitot Static Tester. Features

ISOCAL - 6 Range Europa Venus Calisto

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

Temperature Calibration Guide

MIT515, MIT525 and MIT & 10 kv DC Insulation Resistance Testers

A Guide to Dry Block Calibration

S1-568, S1-1068, S1-1568

5 kv and 10 kv Insulation Resistance

ADTS 405 MkII. Druck Air Data Test System. GE Measurement & Sensing. Features. Design History with TERPS Innovation

MIT515, MIT525, MIT1025, MIT1525

MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kv DC Insulation Resistance Testers

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

HC1, HC2 and HC9. Helmholtz Coil Systems

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Mixer/Temperature Control

Thermo-hygrometer-anemometer VT 210

orb effortless reactions Unrivalled quality» Intuitive design» Exceptional value

Thermo-hygrometer-anemometer VT 210

Fluke 500 Series Battery Analyzers

FEATURES AND BENEFITS

Thermo-anemo-manometer MP 210

PAT120, PAT150 and PAT150R

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

ITC series. Industrial Temperature Calibrators. Portable and easy-to-use temperature calibrator

DT304. Digital Temperature Logger INSTRUCTION MANUAL

MJÖLNER 200 Microhmmeter

DPI 620 Genii. Advanced Modular Calibrator and HART / Foundation Fieldbus Communicator. GE Measurement & Control

2-Color Display High-Precision Digital Pressure Switch

DLRO10HDX 10 Amp Digital Low Resistance

Heat Shield Portable wireless WBGT meter

Immersion temperature sensor QAE26.9.

CU2 Closed Loop Module

ITC series. Industrial Temperature Calibrators. Portable and easy-to-use temperature calibrator

Thermo-anemo-manometer

HUMIDITY / TEMPERATURE TRANSMITTER

Micro Motion 7827 Digital Viscosity Meter

Solenoid coils VACF Type codes

better measurement Simply a question of

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D*

Switching DC Power Supply

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Digimar 816 CL. Versatile. User-friendly operation... The measuring program... Precise measuring results...

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

VariStroke II Electro hydraulic Actuator

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Resistance thermometer Without thermowell Model TR10-H

Series TCL-650S-D / TCL-165S-D TCL-M165S-B / TCL-M255S-B

c-go 24V/6A 24V/8A 24V/12A

GE Measurement & Control

Instruction Manual. Single-Input Thermistor Thermometer (Model )


CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

ATC series JOFRA TM. Advanced Temperature Calibrator. Your choice for optimum temperature calibration. Specification Sheet NOTICE

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Hour Meter Series HM36

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Integrated temperature test and calibration bench Model CBS-SC4000

362 Clamp Meter. Users Manual

better measurement Simply a question of

Cable Temperature QAP... Sensor. Use

Calibration Solutions for Industrial Temperature Sensors 4000 Series

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.


Smart Tools. spacebefore Belt tools... spacebefore 298. spacebefore Shaft alignment tools... spacebefore 301

Stabinger Viscometer SVM 3001

Waukesha E-Series Pump HYGIENIC MAGDRIVE CENTRIFUGAL PUMP

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Solenoid coil for control in potentially explosive areas Type BZ

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Committing to the future. The digital manifold testo 550, ideal for all measurement work on refrigeration systems and heat pumps

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

SRS SEALED ROTARY SENSORS

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Operation Manual for. CU2 Helmholtz Coil System Closed-Loop Module

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Model ATC-140/250 Advanced Temperature Calibrator

Thermo Scientific Variomag Magnetic Stirrers

Product specification

8000 Series Liquid Flow Meters

Temp-14 Single Input Thermistor Thermometer

TCS 1200 Portable Temperature Calibrator

Temperature calibrators

MIT515, MIT525, MIT1025, MIT kv, 10 kv, 15 kv DC Insulation resistance testers

TORRIX Magnetostrictive level sensor

Handheld Micro Ohmmeters RMO-H series

Transcription:

GE Measurement & Control Dry Block and Liquid Bath Temperature Calibrator Series Accurate temperature measurement is essential for maintaining product quality, process efficiency, regulatory compliance and operational safety in industrial processes. High performance, stable temperature sources are the solution for achieving optimal performance of temperature sensors and process instrumentation, by providing reference temperatures for checking and calibrating these devices. The GE Dry Block and Liquid Bath Temperature Calibrators provide solutions for testing temperature devices over a range of temperatures from -35 C to 650 C (-30 F to 1200 F) with a choice of dry block and liquid bath configurations to accommodate virtually any type, shape and size of sensor.

The design philosophy is one of simplification, that is, simplifying the complex arts and skills of temperature calibration to provide instrument technicians with a highly accurate, yet simple to use temperature reference. Calibrated to EA-10/13 (European Co-operation for Accreditation Guidelines on the Calibration of Dry Block Calibrators) ensuring high accuracy without the necessity of a reference probe! Quick and easy touch screen setting and set point memory recall Dry block and liquid bath configurations with multi use options for switching between dry, liquid and infra-red well inserts The Liquid Baths Accommodate anything from unique probe sizes to irregular shapes and provide a massive 60mm x 170mm capacity for simultaneously testing multiple sensors DryTC 165 and DryTC 650 These dry block calibrators incorporate the latest metal block and electronic control technology and offer a choice of precision bored well inserts to accommodate a wide range of test devices. Two models are available: DryTC 165 generates temperatures from -35 C to 165 C DryTC 650 generates temperatures from ambient to 650 C. Both models provide high accuracy, excellent set point stability and rapid heating and cooling times. Temperature range from -35 C to 650 C Accuracy from 0.2 C Stability 0.05 C Rapid heating and cooling Light weight and robust for field use Choice of interchangeable well inserts Easy to set-up and use Dry well insertion sleeves Dry block calibrators greatly simplify the test and calibration of process sensor heads, probes, switches and thermometers, but optimum performance relies on a good fit of the device in the well insert. To facilitate this, a range of insertion sleeves are available with hole diameters to suit the most common probes and devices. LiquidTC 165 and LiquidTC 255 These multi-purpose calibrators combine the portability of dry block calibrators with the flexibility of liquid immersion baths to enable the testing and calibration of virtually any shape and size of devices. The calibrators can be reconfigured by the user to function as a liquid bath, as an infrared black body source and as a dry block calibrator with interchangeable inserts. The latest heating and electronic control technology, combined with continuous liquid agitation of the fluid bath, provide high accuracy and stability throughout the large homogeneous measuring zone. The calibrators are factory configured as liquid baths and are provided with a bath cover to hold up to 5 devices while reducing heat loss from the surface of the liquid medium. For transportation a leak-proof sealing cover is also provided as standard. Optionally the temperature calibrators can be configured with additional capabilities including interchangeable liquid baths, a black body source and dry block interchangeable inserts. Two models are available: LiquidTC 165 generates temperatures from -35 C to 165 C LiquidTC 255 generates temperatures from ambient to 255 C Temperature range from -35 C to 255 C Accuracy from 0.1 C Stability 0.05 C Large bath for irregular and multiple devices Multi-purpose liquid bath, black body source, dry block Interchangeable bath simplifies fluid changes Light weight and robust for field use Leak-proof bath cover for transportation High capacity portable liquid bath Standard factory configuration provides a 60 mm x 170 mm liquid bath with automatic liquid agitation. Interchangeable liquid bath inserts Allows the calibration media to be simply and quickly changed to suit different temperature ranges, while retaining the automatic liquid agitation. Infra-red black body source A specially constructed insertion sleeve provides an emissivity of 1 (black body). Dry well insertion sleeves For the convenience of a dry block calibrator a range of insertion sleeves are available with hole diameters to suit most common probes and devices. Dry block and liquid bath general features Controller OFF disables automatic temperature control at the last set point temperature to allow the calibrator settings to be changed part way through a test. Manual control allows the power output of the calibrator to be adjusted to control the rate at which the calibrator reaches the set-point temperature. Set-point memory allows up to four set-point temperatures to be stored in memory. The test sequence can then be activated with a single key press. Test profile this function defines a temperature profile with a heating rate to the first set-point value, a test duration or soak time at set-point one followed by a cooling rate to a second set-point. PC communications -An optional USB cable is available for connection to a PC.

Specifications LiquidTC 165 LiquidTC 255 DryTC 165 DryTC 650 Temperature Ranges -35 to 155 C (-30 to 310 F option) with TCL 10 oil supplied 25 to 165 C (-77 to 330 F option) with optional TCL 50 oil Ambient to 255 C (Ambient to 490 F option) -35 to 165 C (-30 to 330 F option) Heat well Dia 60 mm/depth 170 mm (150 mm working depth) Dia. 28 mm/depth 150 mm Measuring Zone 0 to 40 mm from the bottom of the insert Stability 0.05 C Ambient to 650 C (Ambient to 1200 F option) Accuracy 0.2 C 0.4 C Standard Liquid Bath -LI 0.1 C 0.2 C Dry block option - DB 0.3 C 0.4 C Infrared black body option - IR 0.5 C 0.5 C Display Black body emissivity 0.9994 Display range -50 C to 165 C 0 to 255 C -50 C to 165 C 0 to 650 C Measurement resolution Standard Features Power requirements Dimensions 0.01 from -9.99 to 99.99 otherwise 0.1 C Setting resolution 0.1 C Supply voltage Controller off, manual control, operating service hours, set-point memory, rate control C /min, test profileir 100 to 240 VAC 50/60 Hz Power consumption 400 VA nominal 1000 VA nominal 400 VA nominal 400 VA nominal Width 210 mm 150 mm 210 mm 150 mm Height 380 + 50 mm 330 + 68 mm 380 + 50 mm 330 + 68 mm Depth 300 mm 270 mm 300 mm 270 mm Weight 13 Kg 7.5 Kg 11.4 Kg 7.5 Kg Environmental Ambient temperature Ambient humidity Storage temperature Altitude Recommended operating environment Compliance Standard Accessories 10 C to 50 C (50 F to 122 F) Specifications valid at 18 C to 28 C (65 F to 82 F) ambient temperature. Minimum and maximum temperatures may not be achieved over the full ambient temperature range. To 80% rh (non-condensing) From -20 C to 70 C (-4 F to 158 F) Up to 2000 metres (6500 ft) Indoor use. Not for use in potentially explosive atmospheres. EN6326 (EMC), EN61010 Oelectrical safety), EU directive (RoHS, REACH, WEEE) 1 lt TCL10 silicone oil 1 lt TCL50 silicone oil, Magnetic stirrer, magnetic lifter, sensor basket, sealing cap, suction pump, sensor lid with 5 silicone plugs, calibration certificate, user manual and mains cable DB option includes one interchangeable liquid bath insert and one dry well insert (1 x 2 mm/3 x 3.5 mm/2 x 4.5 mm/ 1 x 6 mm). IR option includes one interchangeable liquid bath insert and one black body insert. Note: If DB and IR options are ordered, only one interchangeable liquid bath insert is provided. Well insert (1 x 3.5 mm/1 x 6.5 mm/1 x 13.5 mm), insert remove tool, calibration certificate, user manual and mains cable

General Specifications Operating temperature (full specification) 18 C to 28 C (65 F to 82 F) Extended operating temperature (reduced specification) 0 C to 50 C (32 F to 122 F) Note: Outside of the operating temperature range, the temperature calibrators may not be able to generate the minimum and maximum temperatures. Ambient humidity To 80% RH (non-condensing) Storage temperature -20 C to 70 C (-4 F to 158 F) Ambient altitude Up to 2000 metres (6560ft) Operating environment Indoor use only. Not rated for use in potential explosive atmospheres Compliance CE marked EMC Compliance EN61326 Electrical safety EN61010 RoHS, REACH and WEEE EU Directive Compliant

Ordering Information DryTC 165 and DryTC 650 Product Code Example: DRYTC 165 Dry block temperature calibrator -35 C to 165 C DRYTC 650 Dry block temperature calibrator ambient to 650 C DRYTC 165-1- D Temperature Unit 0 C working temperature unit 1 F working temperature unit Power Lead A EU plug C Australia / New Zealand plug D UK plug G South Africa / India plug J Japan plug K USA plug R China plug LiquidTC 165 and LiquidTC 650 Product Code LIQUID TC165 Liquid bath temperature calibrator -35 C to 165 C LIQUID TC255 Liquid bath temperature calibrator ambient to 255 C Temperature Unit 0 C working temperature unit 1 F working temperature unit Calibration Function 0 Standard liquid bath configuration 1 Combination liquid bath (LI) and infrared (IR) functions 2 Combination liquid bath (LI) and dry block (DB) functions 3 Combination liquid bath (LI), infrared (IR) and dry block (DB) functions Power Lead A EU plug C Australia / New Zealand plug D UK plug G South Africa / India plug J Japan plug K USA plug R China plug Example: LIQUIDTC 165-0 -2 -K Accessories (Please order the following part numbers as separate line items:) TCUSB USB output including a cable to connect to a PC TCCASE1 Aluminium transit case TCL10 Dow Corning 200 /CS10 silicone oil -35 C to +155 C TCL50 Dow Corning 200 /CS50 silicone oil +25 C to +270 C TCSTAND Probe support stand TCBATH Interchangeable liquid bath for use with LiquidTC165 and LiquidTC255 with LI configuration TCDKD DKD accredited Calibration. Not applicable to IR option of LiquidTC165 and LiquidTC255

Adaptor inserts Single bore adaptor insert for DryTC 165 and 650 GE Part number Type DRY Length mm 150 Diameter mm 28 Bore size mm 1.5 015 MS 2.0 020 MS 2.5 025 MS 3.0 030 MS 3.5 035 MS 4.0 040 MS 4.5 045 MS 5.0 050 MS 5.5 055 MS 6.0 060 MS 6.5 065 MS 7.0 070 MS 7.5 075 MS 8.0 080 MS 8.5 085 MS 9.0 090 MS 9.5 095 MS 10.0 100 MS 10.5 105 MS 11.0 110 MS 11.5 115 MS 12.0 120 MS 12.5 125 MS 13.0 130 MS 13.5 135 MS 14.0 140 MS 14.5 145 MS 15.0 150 MS 15.5 155 MS 16.0 160 MS 16.5 165 MS 17.0 170 MS 17.5 175 MS 18.0 180 MS 18.5 185 MS 19.0 190 MS 19.5 195 MS 20.0 200 MS 20.5 205 MS 21.0 210 MS 21.5 215 MS 22.0 220 MS 22.5 225 MS 23.0 230 MS 23.5 235 MS 24.0 240 MS 24.5 245 MS 25.0 250 MS 25.5 255 MS Multi bore adaptor insert for DryTC 165 and 650 Type DRY Length mm 150 GE Part number Diameter mm 28 Number of bores 0 B 00 MS 1 B 01 MS 2 B 02 MS 3 B 03 MS 4 B 04 MS 5 B 05 MS 6 B 06 MS 7 B 07 MS 8 B 08 MS 9 B 09 MS 10 B 10 MS 11 B 11 MS 12 B 12 MS 13 B 13 MS 14 B 14 MS 15 B 15 MS 16 B 16 MS 17 B 17 MS 18 B 18 MS 19 B 19 MS Please specify the bore sizes required from 1.5mm to 25.5 mm in increments of 0.5 mm. Example ordering codes: Use Dry 150 28 050MS to order an insert with a single 5 mm bore. Use Dry 150 28 B02MS, 10 mm and 12 mm to order an insert with two bores of 10 mm and 12 mm.

Single bore adaptor insert for LiquidTC 165 and 255 GE Part number Type LIQ Length mm 163 Diameter mm 60 Bore size mm 1.5 015 AL 2.0 020 AL 2.5 025 AL 3.0 030 AL 3.5 035 AL 4.0 040 AL 4.5 045 AL 5.0 050 AL 5.5 055 AL 6.0 060 AL 6.5 065 AL 7.0 070 AL 7.5 075 AL 8.0 080 AL 8.5 085 AL 9.0 090 AL 9.5 095 AL 10.0 100 AL 10.5 105 AL 11.0 110 AL 11.5 115 AL 12.0 120 AL 12.5 125 AL 13.0 130 AL 13.5 135 AL 14.0 140 AL 14.5 145 AL 15.0 150 AL 15.5 155 AL 16.0 160 AL 16.5 165 AL 17.0 170 AL 17.5 175 AL 18.0 180 AL 18.5 185 AL 19.0 190 AL 19.5 195 AL 20.0 200 AL 20.5 205 AL 21.0 210 AL 21.5 215 AL 22.0 220 AL 22.5 225 AL 23.0 230 AL 23.5 235 AL 24.0 240 AL 24.5 245 AL 25.0 250 AL 25.5 255 AL Multi bore adaptor insert for LiquidTC 165 and 255 Type LIQ Length mm 163 GE Part number Diameter mm 60 Number of bores 0 B 00 AL 1 B 01 AL 2 B 02 AL 3 B 03 AL 4 B 04 AL 5 B 05 AL 6 B 06 AL 7 B 07 AL 8 B 08 AL 9 B 09 AL 10 B 10 AL 11 B 11 AL 12 B 12 AL 13 B 13 AL 14 B 14 AL 15 B 15 AL 16 B 16 AL 17 B 17 AL 18 B 18 AL 19 B 19 AL Please specify the bore sizes required from 1.5mm to 25.5 mm in increments of 0.5 mm. Example ordering codes: Use LIQ 163 60 035AL to order an insert with a single 3.5 mm bore. Use LIQ 163 60 B03AL 7.5 mm, 9 mm and 12.5 mm to order an insert with three bores of 7.5 mm, 9 mm and 12.5 mm.

www.ge-mcs.com 920-650A 2014 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.