Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 500W Slim Type with PFC Switching Supply S&E GB4943 UL950- EN950- IEC950- % - ~+ Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipments or apparatus LED display application is a 500W single-output slim type power supply with 3mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 4.2V, 5V, 2V, 5V, 24V, 36V and 48V. In addition to the high efficiency up to 95%, that the whole series operates from -20 ~ 70 under air convection without fan. UHP-500 has the complete protection functions and 5G anti-vibration capability; It is complied with the international safety regulations such as TUV EN950-, UL950- and GB4943. serves as a high performance power supply solution for various industrial applications. R
SPECIFICATION MODEL UHP-500-4.2 UHP-500-5 UHP-500-2 UHP-500-5 UHP-500-24 UHP-500-36 UHP-500-48 DC VOLTAGE 4.2V 5V 2V 5V 24V 36V 48V RATED CURRENT A A 4.7A 33.4A 20.9A 3.9A 0.45A RATED POWER(convection) 336W 0W 500.4W 50W 50.6W 500.4W 50.6W RIPPLE & NOISE (max.) Note.2 200mVp-p 200mVp-p 200mVp-p 200mVp-p 2mVp-p 3mVp-p 3mVp-p OUTPUT VOLTAGE ADJ. RANGE 3.6~4.4V 4.5~5.5V.4~2.6V 4.3~5.8V 22.8~25.2V 34.2~37.8V 45.6~50.4V VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±.0% ±.0% ±.0% ±.0% ±.0% LINE REGULATION ±0.5% ±0.5% ±0.3% ±0.3% ±0.3% ±0.3% ±0.3% LOAD REGULATION ±.0% ±.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 000ms, 50ms/230VAC 000ms,50ms/5VAC at full load HOLD UP TIME (Typ.) 2ms/230VAC 2ms/5VAC VOLTAGE RANGE Note.4 90 ~ 264VAC 27 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF 0.95/230VAC PF 0.98/5VAC at full load INPUT EFFICIENCY (Typ.) 89% 90% 94% 94% 94.5% 95% 95% AC CURRENT (Typ.) 4.85A/5VAC 2.6A/230VAC INRUSH CURRENT (Typ.) Cold start 30A/5VAC A/230VAC LEAKAGE CURRENT <0.75mA / 2VAC PROTECTION FUNCTION OTHERS OVERLOAD OVER VOLTAGE OVER TEMPERATURE DC OK SIGNAL(Optional) REDUNDANT(Optional) MTBF DIMENSION PACKING 0~% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 4.62 ~ 5.46V Protection type :Shut down O/P voltage,re-power on to recover Protection type :Shut down O/P voltage, recovers automatically after temperature goes down ENVIRONMENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION -20 ~ +70 (Refer to Derating Curve") 20 ~ 90% RH non-condensing - ~ +85, 0 ~ 95% RH non-condensing ± 0.03%/ (0 ~ 50 ) 0 ~ 500Hz, 5G 0min./cycle, min. each along X, Y, Z axes SAFETY & EMC (Note.6) SAFETY STANDARDS EMC EMISSION EMC IMMUNITY 68K hrs min. MIL-HDBK-27F (25 ) 232*8*3mm (L*W*H) 5.75 ~ 6.75V 3.2 ~ 5.6V 6.5 ~ 9.5V 26.4 ~ 3.2V 39.6 ~46.8V 52.8 ~ 62.4V Contact rating(max.):30vdc/a resistive load For parallel connection protection:for parallel applications, when one PSU can not work, the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system UL950-,TUV EN950-, CCC GB4943, EAC TP TC 004 approved;design refer to EN335-,EN6558-2-6 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:.25KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG,O/P-FG:00M Ohms/500VDC/25 / 70%RH Compliance to EN55032,GB/T9254,Class B, EN00-3-2,-3, EAC TP TC 020 Compliance to EN00-4-2,3,4,5,6,8,;EN00-6-2 (EN50082-2), heavy industry level,criterial A,EAC TP TC 020 0.905kg; 6pcs/5.48kg/0.82CUFT NOTE includes set up tolerance, derating curve
Block Diagram I/P EMI FILTER & RECTIFIER PFC CIRCUIT POWER SWITCH- ING RECTIFIERS & FILTER FG O.T.P. O.L.P. CONTROL DETECTION CIRCUIT O.V.P. DC OK Function Redundant Function Derating Curve RATED CURRENT (%) 2V,5V 00 others 4.2V,5V 20 RATED CURRENT (%) 00 90 70 50 20 230Vac for 2V,5V 230Vac for 4.2V,5V 0Vac for other 0Vac for 4.2V,5V 230Vac for other -20 0 0 20 30 45 50 70 (HORIZONTAL) -20 0 0 20 30 45 50 70 (HORIZONTAL) AMBIENT TEMPERATURE ( ) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE( ) 00 RATED CURRENT (%) 20-30 0 0 20 30 50 70 90 (HORIZONTAL) Tcase ( )
STATIC CHARACTERISTIC 00 90 LOAD (%) 70 50 90 00 0 20 200 220 2 264 INPUT VOLTAGE (V) Hz DC OK Relay Contact Contact Close Contact Open Contact Rating(max.) PSU turns on/dc ok PSU turns off/dc fail 30Vdc/A resistive load Redundant function () UHP-500R is built-in redundant function and can be connected 2 units in parallel. (2) When in parallel operation the maximum load should not be greater than the rated power of any PSU. PSU LOAD PSU
Mechanical Specification CASE NO.:233D Unit:mm 232.0 226.0 3 9 2 3 63 2 2 3 4 8 VR 2.75 56.75 R2. 6 5.5 tc 3 tc : Max. Case Temperature AC Input Terminal(TB) pin NO. Assignment DC Output Terminal(TB2,TB3) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque Pin No. Assignment Terminal Max mounting torque AC/L (DEGSON),2 (MW) 2 AC/N DG28C-B-03P 5Kgf-cm 3,4 MEL-0-02P 8Kgf-cm 3 DC OK Connector(CN):JST B2B-PH-K-S or requivalent Mating Housing Terminal Pin No. 2 Assignment DC COM DC COM2 JST PHR-2 or requivalent JST SPH-002T-P0.5S or requivalent
Installation.Operate with additional aluminum plate In order to meet the Derating Curve and the Static Characteristics, must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.the size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and must be firmly mounted at the center of the aluminum plate. unit:mm 450 M3*4 3 450
Sager Electronics and its specialized group Sager Power Systems is an authorized distributor of MEAN WELL and the UHP500 series of power supplies. Visit the UHP500 Series online. Or contact a Sager Power Systems representative at.866.588.750 or power@sager.com for price and availability. Sager Power Systems, the authorized distributor for MEAN WELL