Outdoor vacuum breaker for railway applications - FSK II

Similar documents
Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

TECHNICAL DESCRIPTION

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Publication No.: PSG

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Product Group Brochure. PS Range Capacitor Vacuum Switches

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

3TM Vacuum Contactors

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Vacuum Circuit Breaker VS1

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Type SDV7 distribution circuit breaker family

Voltage limiting device HVL

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Voltage limiting device HVL

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Surge arrester POLIM-H..SD

Documents and Addresses

Contactor V-Contact VSC/P

EMPAC Metal enclosed capacitor bank for wind applications

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

B kv T&D GAS INSULATED SWITCHGEAR

Surge arresters Product overview

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Independent Testing Laboratory for High Voltage Equipment

Prüffeld der Schaltwerke

NXPLUS C Single busbar. Maintenance-free for lifetime

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

B kv Gas-insulated Substations

Siemens AG Catalog HG11.07 Edition 10/ AE6 Medium-Voltage Equipment. siemens.com/sion

Live Tank Circuit Breakers Buyer s Guide

Air-insulated switchgear UniGear type ZS1

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Surge arrester POLIM-H.. ND

Horizontal Circuit Switchers

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Cobra-S. Catalog Cobra-S

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS

Transformer bushings, type GOH. Technical guide

RCS Capswitch Longest Life of ANY Distribution Capacitor Switch with 30,000 Maintenance-Free Operations! Catalogue Rockwill Electric Co., Ltd.

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Q pole Pole Mounted Capacitor System

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

The galvanic separation of the primary or actuating circuit and the load circuits

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

OHB Outdoor sulphur Hexafluoride circuit-breaker

Type SDV7 distribution circuit breaker family Answers for energy.

Horizontal Circuit Switchers

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Surge arrester POLIM-C.. HD

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

Ultra Fast Earthing Switch UFES retrofit Overview

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Vacuum Circuit-Breaker Modules

SF 6 Gas Insulated Load Break Switch

AF series contactors (9 2650)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Report No.: MS/E Copy No.: 0 Contents: 140 sheets

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

RESIDUAL CURRENT CIRCUIT BREAKER

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Solid Dielectric, Single Phase Recloser

GROUP D. Switch & Protective device.

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

SUBSTATIONS. Energy Storage System

High voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators

EISHO TEK. Vacuum Circuit Breaker

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

3AH37 and 3AH38 vacuum generator circuit-breakers for power stations and industry

Modular contactor for installation into distribution boards

Transcription:

Outdoor vacuum breaker for railway applications - FSK II Single or two-pole outdoor vacuum breaker with magnetic actuator 27.5 kv - 250 kv BIL - 1250 A. 2000 A - 25.0 ka - 50/60 Hz 27.5 kv - 200 kv BIL - 1250 A. 2000 A - 25.0 ka - 50/60 Hz

50/60 Hz outdoor breaker for railway-traction-power-supply PRODUCT DESCRIPTION... 3 HIGH-VOLTAGE POLE... 3 THE MAGNETIC DRIVEN OPERATING MECHANISM... 4 BLOCK DIAGRAM... 4 THE MAGNETIC ACTUATOR... 4 THE CONTROL BOARD... 5 POWER SUPPLY... 5 CONTROL UNIT... 5 THE CAPACITOR BANK... 6 END POSITION SENSORS... 6 SELF MONITORING... 6 THE CONTROL BOX... 6 COMPARISON TO THE SPRING-CHARGED MECHANISM... 6 TECHNICAL SPECIFICATIONS OF THE HIGH VOLTAGE POLE... 7 RATINGS... 7 DIMENSIONS... 7 VACUUM INTERRUPTER... 7 MAGNETIC ACTUATOR... 7 CHARACTERISTICS OF THE CONTROL BOARD... 8 ACCESSORIES... 8 SERVICE CONDITIONS... 8 TYPE TESTS REPORTS... 9 ROUTINE TESTS... 9 MARKINGS ON THE NAME PLATE... 9 TECHNICAL DOCUMENTATION... 9 OUTLINE DRAWINGS... 10 2

Product description High-voltage pole A new generation of FSK type breakers has been developed to address the railway AC market for outdoor application. As result of a continuous improvement of former products dedicated to the same application range, this product line is based on proven technology components and uses vacuum interrupting technology. The current is interrupted in a bottle in which a high vacuum exists. When the contacts open, a metal vapour arc appears between the contacts. This vapour carries the current until next current zero. The arc extinguishes at current zero and metal vapour condenses on the metal surfaces within a few microseconds, which means that the gap recovers its dielectric strength very rapidly. Thanks to fast interruption and low arc resistance, the wear of the contacts is low and therefore the electrical endurance is very high. This technology is well suited for railway application where the operating conditions are specially demanding. The pole consists in vacuum interrupter(s) (), encapsulated within hollow porcelain insulators (). On request silicon insulators may replace the porcelain insulators. The space between the insulator and vacuum interrupter () is filled in with 0.5 bar pressure dry nitrogen N2 (or SF6 gas on request). The gas guarantees a moisture free stable environment around the interrupter. The N2 (or SF6) gas is unaffected by the electric arc which occurs only inside the vacuum. 3

The magnetic driven operating mechanism Block diagram The magnetic actuator is an ultra-modern concept for operating mechanism construction; storing and monitoring its energy electrically. The result is a completely maintenance-free drive system, which can confidently be expected to have even longer life times than its mechanical predecessors. Careful selection of all components and reliable design guarantee maximum reliability even under EMC load. The magnetic actuator technology has been successfully introduced for medium voltage circuit breakers in the three-phase market. The magnetic actuator Considering the number of magnetic-driven breakers in operation, the return of experience has already demonstrated the same reliability as a spring-charge mechanism. The FSK II is the world s first commercially produced outdoor breaker for railway powersupply, which uses the actuation technology. The benefits of this technology are: Reduced maintenance duties Increased reliability of operation thanks to reduced number of components and related settings Interfaces through digital inputs with reduced power demand Fast simple exchange of any main component. Total exchangeability of poles and commands The actuator is a bi-stable magnet system, made of two permanent magnets maintaining the device in open or closed position, and two electrically excited coils. Switching operations are released by excitation of one of the coils until the retaining force of the permanent magnets is exceeded. The magnetic actuator transmits directly its movement to the vacuum interrupter mobile contact. The vacuum interrupter can also be opened manually with a crank, part of maintenance tools. 4

The control board The control board consists of two main elements: The power supply The control unit Power Supply All necessary application-specific input and output signals are independent of the type of auxiliary voltage in accordance with the rest of the system, and are integrated by plug-in technology. The selection of a suitable internal power supply with feed via a UC-DC converter makes the breaker independent of the type and also almost of the level of auxiliary voltage. The power supply has a galvanic insulation to protect the circuit breaker from external disturbances. Control Unit The logic of the processing unit takes account of priority of OFF commands and integrates anti-pumping and self-monitoring features. Inputs and outputs Several digital inputs control the circuit breaker. Two Off-switching inputs are available as well as one Closing lock-out input. The inputs are fitted with low-pass filters, to damp out line disturbances. Thanks to a bridge-rectifier, 50 Hz signals can supply the inputs without any additional interface. Several digital outputs report the status of the circuit breaker. Circuit breaker opened and Circuit breaker closed outputs are available as well as one Ready output and one Not Ready output. Local control The local control of the interrupter is performed with On/ Off push buttons. A Led indicates the Ready for operation status. The Control Unit consists in principal of input channels, processing unit, power outputs and message outputs. Processing unit The main tasks of the processing unit are: To accept an incoming operation command, from local push-buttons or from a remote control system To check the status of the other inputs, the capacitor voltage and the position information, To switch the capacitor voltage on the relevant coil To disconnect the coil from the capacitor once the main contact reached its final position 5

The capacitor bank The capacitor stores the electrical energy needed for a complete autoreclosing cycle but also ensures power supply to the electronics. The energy content is sufficient for a buffer time of 200 s on failure of the auxiliary power. After an autoreclosing cycle, the recharge of capacitor bank requires less than 100 W (average value over the charging time) for only a few seconds. The external power consumption is very low when the breaker is in the On or Off position. End position sensors Self monitoring A watchdog monitors if the programmable logic array is working. Additional internal conditions are monitored: Availability of the internal voltage Position of the end position sensors (XOR logic) Voltage level of the capacitor If these four conditions are fulfilled, the Ready LED is shining, the output contact Ready is closed and the output contact Not Ready is open. The control box The control box is a small stainless cabinet housing the electronic board, the capacitor, the heating resistance, local push buttons and optional voltage free NO/ NC contacts. Comparison to the springcharged mechanism The major difference with a spring charge mechanism is the significant reduction of site works. The concept of a breaker control system without any auxiliary switches makes use of sensors to detect the position of the lever shaft. The inductive proximity sensors employed have proven their worth for these functions in practice, and are of course also included in the self-monitoring system. In addition a mechanical indication ( flag ) of the position of the vacuum interrupter is provided. Cables transmit energy from the command to the pole(s), therefore no mechanical adjustment is required neither in factory nor on site. Pole and command are totally independent and do not need to be paired on site. FSK II also brings better performances than its predecessor (shorter operating time, wider current range, better synchronisation when used in two-pole configuration, etc.). 6

Technical specifications of the high voltage pole Type designation FSK 1020 or FSK 1025 Ratings Rated voltage 27.5 kv Rated continuous current 1'250 A 2'000 A 2'500 A Rated frequency 50 Hz Number of phase 1 or 2 Rated short-circuit breaking current Rated short circuit making current Rated short time withstand current 25 ka 63 ka 25 ka, 3 s Rated power frequency withstand voltage (50 Hz, 1 min) Phase to earth 95 kv 105 kv Across open contacts 95 kv 110 kv Rated impulse withstand voltage (1.2/50 µs) Phase to earth 200 kv 250 kv Across open contacts 200 kv 250 kv Opening time Closing time Rated operating sequences 40 ms 60 ms O - 0.3 s - CO 180 s - CO CO - 10 s - CO Standard applied EN 50152-1 IEC 694 Creepage distance (external) Between live part and earth 1 215 mm 1720 mm Between Terminals 1 215 mm 1720 mm Flashover distance 400 mm 525 mm Dimensions Outline drawing FSK 1020 FSK 1025 Vacuum interrupter Storage life Vacuum degree > 20 years < 10-4 Pa Electrical endurance 1) at rated current 20'000 at rated short circuit current 50 1) According to vacuum interrupter datasheet Magnetic actuator Mechanical endurance 100 000 7

Characteristics of the control board Power supply voltage range Service operating voltage, low voltage range Service operating voltage, high voltage range Consumption In normal position During a charging process Recharging time 20 60 V AC/DC 80 264 V AC/DC 4 W.. 10 W approx. 100 W Capacitor bank recharging time at minimum voltage 3 s 1) Capacitor bank recharging time at maximum voltage 2 s 1) 1) Charging time for capacitor bank of 0.1 F Binary inputs Electrical isolation from the electronics Electrical isolation between the inputs Maximum input voltage Response range Current consumption Protection against voltage surges Binary outputs Electrical isolation from the electronics Electrical isolation between the inputs Maximum switching voltage Maximum switching current 2 kv AC 2 kv AC 260 V AC/DC 48 to 250 V AC/DC 2 ma at 250V AC/DC Yes 2 kv AC 2 kv AC 400 V DC / 280 V AC 0.5 A AC/DC Accessories Five-digit operation counter 1 Electrical opening and closing push button 1 + 1 Mechanical indicator Close / Open 1 Electrical indicator Ready 1 Local/ Remote Switch (option) 1 Service conditions Operating temperature range Altitude - 25 / +50 C 1000 m 8

Type tests reports Copies of following type tests reports are available on request: Insulation voltage Short-circuit breaking and making current Short-circuit withstand current and peak withstand current Capacitive current Temperature rise Measurement of the main circuit resistance Mechanical endurance test Only routine tests are performed for delivery of the equipment. Routine tests The following routine tests are carried out in the seller s factory: Construction inspection Mechanical operation and mechanical data test Measurement of the main circuit resistance Power frequency withstand voltage of the main, auxiliary and control circuit Markings on the name plate Following information are mentioned on the name plate: Manufacturer s name and trade mark Type designation name Date of manufacture and serial number Rated voltage Rated lightning impulse withstand voltage Rated current Rated short circuit breaking current Rated operating sequence Rated frequency Name and type of the operating mechanism; Technical documentation For each order, the following technical documentation (in English) will be provided in 2 copies: Operation and maintenance manual Outline drawing for the pole Outline drawing of the mechanism box Wiring diagram Routine test reports 9

Outline drawings FSK 1025, 1250 A, Porcelain ABB Sécheron Ltd Rue des Sablières 4-6 / Voie 11A Zone industrielle Meyrin-Satigny CH-1217 Meyrin Contact: P.O. Box 2095 CH-1211 Geneva 2 Tel: +41 22 306 21 17 Fax: +41 22 306 26 82 E-mail : info.abbsecheron@ch.abb.com www.abb.com/railway FSK 1020, 1250 A, Porcelain 1VSR632510B- en, Rev: G, Copyright ABB.2004 Subject to modification without notice