Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER, SIZE S00, Technical Data CIRCUIT-BREAKER, SIZE S00, FOR MOTOR PROTECTION, CLASS 0, A REL.0.22...0.2A, N REL.4.2A SCREW CONNECTION, STANDARD BREAKING CAPACITY W. TRANSV. AUX. SWITCH NO/NC General technical data: Size of the circuit-breaker S00 Trip class CLASS 0 Protection class IP IP20 Ambient temperature / during the operating phase -20 C 70 C Item designation according to DIN 4079 extendable after IEC 204-2 / according to IEC 750 according to DIN EN 646-2 Design of the auxiliary switch Type of the driving mechanism / Motor drive design of the operating mechanism Product function Overload protection Short-circuit to earth recognition Phase disturbance recognition Product component auxiliary switch Undervoltage release mechanism trip indicator product extension / optional / Motor drive Main circuit: Type of voltage Number of poles Service power / at AC- at 400 V / rated value Service power / for three-phase servomotors rated value Arrangement of electrical connectors for main current circuit Adjustable response current of the non-delayed short-circuit release of the current-dependent overload release Q Q transverse rocker AC/DC 0.09 kw 0.09 kw front side 4.2 A 4.2 A 0.22 A 0.2 A
Continuous current / rated value Auxiliary circuit: number of NC contacts / for auxiliary contact number of NO contacts / for auxiliary contact number of change-over switches / for auxiliary contact 0 Short-circuit: Switch-off capacity limit short-circuit current at 400 V / rated value Design of the overcurrent release and short-circuit release Installation/mounting/dimensions: Type of fixing/fixation Width Height Depth Connections: Design of the electrical connection for main current circuit Further information: Information- and Downloadcenter (Catalogs, Brochures, ) http://www.siemens.com/lowvoltage/catalogs Global Industry Mall (Online ordering system) http://www.siemens.com/lowvoltage/mall 0.2 A 00 ka thermomagnetic screw and snap-on mounting onto 5 mm standard mounting rail according to DIN EN 50022 45 mm 90 mm 8 mm Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/ww/view/en/rv0-0da5/all screw-type terminals last change: 04/06/2009 Siemens AG 2009 - Corporate Information - Privacy Policy - Termsof Use
RV Motor Starter Protectors For Motor Protection RV0 Class 0 up to 2A SIRIUS Description The RV0 MSP s, can be used as components in Group Installation per NEC 40-5(C) to turn motors on and off. Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the RV0 is used as a component in Group Installation, multiple MSP s can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to provide a remotely operated starter. Ordering Information ON/OFF rocker mechanism with lockout. Adjustment dial for setting to motor FLA. Class 0 overload trip characteristics. Short circuit trip at 2 times the maximum setting of the FLA adjustment dial. Short circuit current rating: Ambient compensated up to 40 F (applies to side by side mounting). Phase loss sensitivity. Test trip function. Cage Clamp version. Auxiliaries and Accessories see pages /8 /5. General Information see pages /28 /. Technical Data see pages /20 /27. Dimensions see page /2. te: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only. UL short- Screw connection Cage clamp Instanta- circuit connection neous breaking Single- short circuit capacity FLA Phase release @ 480 V List List Adjustment HP Ratings Three-Phase HP Ratings I > I cu Price Price Illustration Range 5V 20V 200V 20V 460V 575V A ka Catalog $ Catalog $ RV0 Frame Size S00 0. 0.6 2. 65 RV0-0AA0 6. RV0-0AA20 2. 0.4 0.2 2.6 65 RV0-0BA0 6. RV0-0BA20 2. 0.8 0.25. 65 RV0-0CA0 6. RV0-0CA20 2. 0.22 0.2 4.2 65 RV0-0DA0 6. RV0-0DA20 2. 0.28 0.4 5.2 65 RV0-0EA0 6. RV0-0EA20 2. 0.5 0.5 6.5 65 RV0-0FA0 0. RV0-0FA20 5. 0.45 0.6 8.2 65 RV0-0GA0 0. RV0-0GA20 5. 0.55 0.8 2 0 65 RV0-0HA0 0. RV0-0HA20 5. 0.7 2 2 65 RV0-0JA0 0. RV0-0JA20 5. 0.9.25 6 65 RV0-0KA0 0. RV0-0KA20 5...6 0 2 65 RV0-AA0 0. RV0-AA20 5..4 2 8 2 2 26 65 RV0-BA0 0. RV0-BA20 5..8 2.5 6 2 2 2 2 65 RV0-CA0 0. RV0-CA20 5. 2.2.2 0 2 2 42 65 RV0-DA0 0. RV0-DA20 5. 2.8 4 8 2 52 65 RV0-EA0 0. RV0-EA20 5..5 5 6 2 65 65 RV0-FA0 0. RV0-FA20 5. 4.5 6. 2 2 5 5 82 65 RV0-GA0 0. RV0-GA20 5. 5.5 8 2 2 5 5 04 65 RV0-HA0 0. RV0-HA20 5. 7 0 2 2 7 2 0 0 65 RV0-JA0 0. RV0-JA20 5. 9 2 2 2 7 2 0 56 65 RV0-KA0 59. RV0-KA20 64. Accessories Transverse auxiliary switch NO + NC separately Approx. weight.02 kg RV9 0-E 24. RV9 0-2E 26. Select MSP by motor full load amps. Horse power ratings for reference only. Size S00 MSP are listed for group installation only. For additional auxiliary switches refer to Accessories, Page /8 (screw connection) and Page /5 (Cage Clamp connection). All setting ranges are suitable for use in group installation for the following ratings. Maximum short-circuit rating: S00-480 V, phase, 65,000 rms symmetrical amps; 600 V, phase, 0,000 rms symmetrical amps. The RT0 devices except suffix -J and -K are suitable for tap conductor protection in group applications used on the above levels. /4 Discount Code: SIRIUS Contactors, OL s, MSP s Siemens Energy & Automation, Inc.
IEC Controls Motor Starter Protectors SIRIUS RV motor starter protectors up to 00 A Size S Size S2 Size S00 Size S0 For motor protection CLASS 0 Selection and ordering data For motor protection CLASS 20 Selection and ordering data General data for SIRIUS motor starter protectors Size Rated current Page Size Rated current Page Page S00 up to 2 A /4 S2 up to 50 A /6 Technical data /20 S0 up to 25 A /5 S up to 00 A /6 Overview /28 S2 up to 50 A /5 Characteristics / S up to 00 A /5 Circuit diagrams / Dimension drawings /2 Ciruit Breaker RV7 SIRIUS RV9 Cage Clamp infeed system RV MSP auxiliaries and accessories Page Page Page Selection and ordering data /7 Selection and ordering data /8-9 Selection and ordering data /8 Circuit diagrams /7 Technical data /6 Technical data /26 Dimension drawings /7 Overview /6 Overview / Dimension drawings /47 Circuit diagrams /5 Dimension drawings /6 /2 Siemens Energy & Automation, Inc.
RV Motor Starter Protectors General Data RV up to 00 A (Domestic applications) SIRIUS Technical data Permissible ratings of devices approved for rth America, u s Motor Starter Protectors of the SIRIUS RV series are approved for u/s. According to UL 508 and C22.2.4 they can also be used with a load feeder contactor. These Motor Starter Protectors can be used as "Manual Motor Starter" for "Group Fusing", or for "Group Installation" or as "Combination Motor Controller Type E". Additional information is found on /29. RV as "Manual Motor Starter" If used as "Manual Motor Starter", the MSP is always operated in combination with a short-circuit protection device (upstream short-circuit protection device). As short-circuit protection device any fusible link ("group fusing") or circuit-breaker ("group installation") of a type and size compliant with American Basic Standard NFPA 70, Article 40-5 (c) can be selected for sufficient protection of the power supply cables. Approvals are found under the following file numbers containing the data listed: u Number File. E5694, Product Class NLRV s File. LR270, Product Class 2 05. MSP hp rating Rated current up to AC 240 V up to AC 480 Y/277 V up to AC 600 Y/47 V for FLA max. I n I cu ) I cu ) I cu ) Type V singlephase A ka ka -phase ka 0.... 2 65 65 0 RV0 2.5 65 65 0 5 / 2.2 65 65 0 200 / 2 4 65 65 0 Size S00 20 2 5 65 65 0 460 7 / 2 6. 65 65 0 FLA max. 2 A, 600 V 575/600 0 8 65 65 0 0 65 65 0 2 65 65 0 0.....2 65 65 0 RV0 2 4 65 65 0 5 65 65 0 5 2 6. 65 65 0 Size S0 200 7 / 2 8 65 65 0 20 5 7 / 2 0 65 65 0 FLA max. 25 A, 600 V 460 5 2.5 65 65 0 575/600 20 6 65 65 0 20 65 65 0 22 65 65 0 25 65 65 0 RV0... 6 65 65 25 20 65 65 25 5 25 65 65 25 Size S2 200 7 / 2 5 2 65 65 25 20 0 20 40 65 65 25 FLA max. 50 A, 600 V 460 40 45 65 65 25 575/600 50 50 65 65 25... 6 65 65 0 RV0 4/RV0 42 20 65 65 0 5 0 25 65 65 0 200 20 0 2 65 65 0 20 20 40 40 65 65 0 Size S 460 75 50 65 65 0 575/600 00 6 65 65 0 FLA max. 99 A, 600 V 75 65 65 0 90 65 65 0 00 (99) 65 65 0 hp rating = Power rating in horse power (maximum motor rating) FLA = Full Load Amps / Motor full load current ) Complies with "short circuit breaking capacity" to UL. /20 Siemens Energy & Automation, Inc.
RV Motor Starter Protectors General Data RV up to 00 A SIRIUS Overview S00 MSP with laterally mounted undervoltage release with leading auxiliary switch RV0 Motor Starter Protectors (MSP s) are built for a world of applications while meeting the requirements of control users worldwide. Each MSP features a manual ON/OFF switch, a Class 0 adjustable bimetallic overload relay (Class 20 available in the two largest frame sizes), and magnetic trip elements for short circuit protection. Construction The motor starter protectors are available in four sizes: Size S00 - RV0 Maximum rated current is 2 Amps. Suitable for motors up to 0 hp at 600V. Available in both screw terminal and Cage Clamp versions. Size S0 - RV02 Maximum rated current is 25 Amps. Suitable for motors up to 20 hp at 600V. Size S2 - RV0 Maximum rated current is 50 Amps. Suitable for motors up to 50 hp at 600V. Size S - RV04 Maximum rated current is 00 Amps. Suitable for motors up to 00 hp at 600V. Functions Releases RV motor starter protectors are equipped with bimetallicbased, inverse-time delayed overload releases - electromagnetic short-circuit releases. The overload releases can be set in accordance with the load current. The overcurrent releases are permanently set to a value times the rated current and thus enable trouble-free start-up of motors. The scale cover can be sealed to prevent unauthorized adjustments to the set current. Release classes The release classes of thermally delayed releases are based on the tripping time (t A ) at 7.2 times the operational current in cold state (excerpt from IEC 60 947-4): CLASS 0 A 2 s < t A w 0 s CLASS 0 4 s < t A w 0 s CLASS 20 6 s < t A w 20 s CLASS 0 9 s < t A w 0 s The release must trip within this time! Operating mechanisms S00 MSP are actuated via a rocker operating mechanism and S0, S2 and S MSP s via a rotary operating mechanism. If the MSP trips, the rotary operating mechanism switches to the tripped position to indicate this. Before the MSP is reclosed, the rotary operating mechanism must be reset manually to 0 position, in order to prevent the former from closing by mistake before the fault has been cleared. In the case of MSP s with rotary operating mechanisms, an electrical signal can be output via a signalling switch to indicate that the MSP has tripped. All operating mechanisms can be locked in 0 position with a padlock (shackle diameter.5 to 4.5 mm). Application Operating conditions RV MSP s are suitable for use in any climate. They are designed for operation in closed rooms under normal conditions (e.g. no dust, corrosive vapours or harmful gases). Suitable enclosures must be provided for installation in dusty or damp rooms. Motor Protection RV MSP s use bimetallic heater elements to provide class 0 or 20 overcurrent protection for both AC and DC motors. The bimetallic heaters sense the motor current directly, so the overloads are insensitive to high frequencies, harmonic waves and sinusoidal currents and voltages. Each MSP has a fourth bimetallic strip that reacts only to the ambient temperature inside the control panel. This ambient compensation prevents the MSP from nuisance tripping when the panel temperature is higher than the ambient temperature of the motor. A built-in differential trip bar causes the MSP to trip faster on a phase loss condition, to help reduce motor damage from phase loss. Magnetic trip elements in each MSP take the device off line when it senses currents of 2 times the maximum FLA dial setting. RV 0-0 A A 0 SIRIUS MSP or Application Frame Size Standard Amperage Range Class Terminal Type Auxiliary Circuit Breaker 0 = Motor Protection = S00 Possible choices listed below see A = 0 = Screw Switch 7 = UL 489 2 = S0 page /4-/7 for an entire listing B = 20 2 = Spring Loaded = S2 4 = S 0,, 4 B through K te: MPS s and Contactors of the same frame size are made to easily fit together with the use of a link module. /28 Siemens Energy & Automation, Inc.