Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual

Similar documents
HT owners manual WHEN ACCURACY IS THE POINT.

G-34 HOPS MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS

C owners manual WHEN ACCURACY IS THE POINT.

J owners manual WHEN ACCURACY IS THE POINT.

o w n e r s m a n u a l

J-Lite. o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T

F-2000 owners manualb&w_f-2000 owners manual out 1/11/13 11:31 AM Page 1 F owner s manual WHEN ACCURACY IS THE POINT

FX-2000 HAY MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

SAM990DW DIGITAL PSYCHROMETER GENERAL TOOLS & INSTRUMENTS USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

Model P772 Conductivity Meter. User Manual

Model Battery Powered Milliohm Meter

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

User's Manual. Earth Ground Resistance Tester. Model Introduction

Model: 1001TH - A INSTALLATION AND OPERATING INSTRUCTIONS

User's Guide. CO 2 Meter. Model CO250

HIGH VOLTAGE DIGITAL AMMETER

HEAT PRESS USER S GUIDE MP885/MP887

THWD-3 and TH-3 Relative Humidity and Temperature Meters

MODEL: 1410-A INSTALLATION AND OPERATION INSTRUCTIONS

DT304. Digital Temperature Logger INSTRUCTION MANUAL

User s Guide HH42A. Thermometer. Shop online at omega.com sm HH42A. For latest product manuals:

GLYCOL SYSTEM MONITOR (GSM)

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

SOIL RESISTIVITY TESTER

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

HLY-1111 HEAD TEMPERATURE GAUGE

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

TMD90A Dual Input Digital Thermometer

HEAT PRESS USER S GUIDE

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

4-20mA DC PROCESS CLAMP METER

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

Model D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

II DISTRIBUTION & SUBSTATION TYPE C

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

Model GX Spray Gun

ODY-19-1 AIR PRESSURE GAUGE

AD-7 THERMAL INDICATING AMMETER

Part Number Analog EGT Gauge

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

INW Panel Meter Reading an INW PT12 Sensor

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

flexible infrared thermometer

Phase Sequence Tester

Owner s Manual Phoenix Quick Chamber

Virtual Measurements & Control. VC210 Operators Manual

ODY-10-1 rev. B FUEL PRESSURE GAUGE

A Member of the. Integrated Metering Technologies

24V Solar Charger. Instructions READ CAREFULLY Garrymore Ln Missoula, MT

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Mechanical Spiral Sensor

JUMP&GO. Portable Jump Start & Power Supply OWNER S MANUAL

CO95. Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH Fax: (503)

User s Manual. Item no. 2561

PVI 60KW, PVI 82KW, PVI 95KW

MODEL: RCTS-MLT III INSTALLATION AND OPERATION INSTRUCTIONS

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Infrared Thermocouple Probe

Right Weigh. Load Scales. Right Weigh Digital Load Scale. Model 201-EDG-01(B) Installation and Operation Manual

STANDARD WARRANTY TERMS *

Cable Length Meter INSTRUCTION MANUAL

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

Please activate my limited warranty for WAGAN Corp.

Tracer ORP PockeTester TM Code 1742

Fifth Wheel Power Hitch Operations Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Dawson DSM170 Multi-Function Moisture Meter User s Manual

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

ABRASIVE BLAST CABINET

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation

2V1-3V1 SERIES SOLENOID VALVE

Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual. Current for Software Version 6.9

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

OMNI GEAR TRACTOR POWERED IMPLEMENT GEARDRIVES

24V Solar Charger. Instructions READ CAREFULLY Garrymore Ln Missoula, MT

Read this entire manual before operation begins.

December 1, 2011

ODY-17-1 DIGITAL COMPASS DISPLAY

NAPA IRONCLAD PRODUCT WARRANTY POLICY

ActuLink ABS Module - ABS-MOD-400

OPERATION AND MAINTENANCE

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

SB-300 Operator s Manual

DC REGULATED POWER SUPPLY

WARNING. Introduction ! ATTENTION

Table of Contents. Page 2. midlandusa.com. Model PPG100

Transcription:

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer Owners Manual TABLE OF CONTENTS 3 INTRODUCTION 3 OPERATION 3 AUTO-OFF 3 BACKLIGHT 4 LOW BATTERY 4 ADJUSTING THE DISPLAY CONTRAST 4 OPERATION SUMMARY 5 CALIBRATION & MAINTENANCE 5 TECHNICAL SPECIFICATION Measurement Accuracy Response Time Resolution Power Supply Battery Life 6 CARE OF YOUR METER 6 SERVICE FOR YOUR METER 7 WARRANTY 1 of 1

SCALE HOLD ON/OFF ROTATE 2 of 2

INTRODUCTION: The model HT-3000 is a portable, battery-powered meter for the measurement of ambient temperature, relative humidity, and through calculation, dewpoint and absolute humidity (grains per pound). The display can be read in either degrees Fahrenheit ( F) or degrees Celsius ( C). OPERATION: 1. Install the battery in the compartment located on the underside of the instrument case handle. 2. Press and hold the ON/OFF button until the display activates. The meter is now ON. The current software version will flash on the screen and then the meter automatically enters its default mode: measured Temperature ( F) and Relative Humidity (%) will appear on the display. T and RH readings are updated at a five second interval. 3. Tap the ROTATE button to alternate between the display of T and RH and the calculated values of Dewpoint and Absolute Humidity. A full set of all four values is always in the meter memory after power up. This allows immediate access to any measured or calculated value, even if the data of interest is not currently displayed. 4. Press the SCALE (F/C) button at any time to switch Temperature and Dewpoint readings between Fahrenheit and Celsius. 5. Press the HOLD button to freeze the displayed readings. The letter H appears at the right of the first display line. The meter stops collecting additional readings, but the SCALE and ROTATE functions are still available. Press the HOLD button again to return the meter to normal operation. 6. Press and hold the ON/OFF button to turn the meter OFF. The meter must be in normal operating mode and not in HOLD mode to turn it off. AUTO-OFF: The meter automatically switches OFF after 10 minutes without any button activity and as long as the meter is not in HOLD mode. If the backlight is active, the auto-off time is 35 seconds. (see below) BACKLIGHT: The meter is equipped with a display backlight, allowing use under poor lighting conditions. Continued use of the backlight presents an extra drain on the battery and significantly reduces expected battery life. 3 of 3

To activate the backlight, tap the ON/OFF button. Tap the ON/OFF button again to turn off the backlight. LOW BATTERY: A low battery indication will appear on the display when voltage is no longer sufficient. Immediately replace the battery (9V Alkaline only). Typical battery life is approximately 55 hours (without backlight). ADJUSTING THE DISPLAY CONTRAST: The display contrast is preset in the system memory at an optimal level. Under most operating conditions, no further adjustment should be necessary. However, if the meter is operated in extreme temperature conditions, some adjustment may be desirable for optimal viewing quality. Procedure: 1. Ensure the meter is not in HOLD mode. Press and hold the ON/OFF button. Keep it pressed throughout the adjustment process. 2. To turn the display darker, press and hold the SCALE (F/C) button within 2 seconds. Release this button when desired contrast is achieved. 3. To turn the display lighter, press and hold the ROTATE button within 2 seconds. Release the button when the desired contrast is achieved. 4. Once the desired contrast is achieved, release the ON/OFF button within 2 seconds. OPERATION SUMMARY: On/Off (Hold) Turns meter ON and OFF if held for longer than 2 seconds Hold Rotate Scale On/Off (Tap) Places meter in HOLD mode: current data is held, all data is available for display Alternates between T/RH and D/AH data set displayed on screen Alternates between F and C scales for Temp. and Dew Point readings Alternates the state of the backlight On/Off + Scale Contrast adj turns display darker. On/Off + Rotate Contrast adj turns display lighter. 4 of 4

CALIBRATION & MAINTENANCE: Continuous exposure to dirt and dust may shorten the life of the RH sensor and also cause the meter to go out of calibration more quickly. Avoid exposure to liquids and other contaminants. Suggested factory calibration interval is one year or more, depending on the application and environment, as well as the desired accuracy. Field calibration is not available for the HT-3000. TECHNICAL SPECIFICATIONS: Measurement Temperature: -20 C to 70 C, -4 F to 158 F Relative Humidity: 0-100% RH Dew Point: -40 C to 80 C, -40 F to 176 F Absolute Humidity: 0.55 gpp to 3868 gpp Accuracy Temperature: +/- 1 C over 0 C -70 C, +/- 1.8 F over 32 F to 158 F Relative Humidity: +/-3% Response time Temperature: reaches 80% of full excursion in approx. 75 seconds Relative Humidity: reaches 90% of full excursion in approx. 45 seconds Resolution 0.1 C; 0.1%RH Power supply (1) 9V Alkaline battery. Battery life Approx. 55 hours under constant use (no backlight) or 23 hours with backlight. 5 of 5

CARE OF YOUR METER: To keep your meter in good working order: Store meter in a clean, dry place. The protective carrying case provided is an ideal storage place when the meter is not in use. Change the 9-Volt battery as needed. Continued use with a low battery may cause the meter to go out of calibration. Clean the meter with any biodegradable cleaner. Use the cleaner sparingly and on external parts only. Remove the battery if the meter will not to be used for one month or longer SERVICE FOR YOUR METER: Pack your meter securely. Enclose a purchase order or letter with a brief description of the problem. There is no need to call us for a return authorization number if you are within the U.S. Customers outside the U.S. must contact us for more specific instructions prior to returning a meter. Include your name, address, daytime phone and fax numbers or e-mail address. If you believe the meter is under warranty, please provide the original sales slip or invoice. Ship via UPS, Express Mail, Priority Mail or any overnight courier who provides prompt service. Do not use standard parcel post. Insure your instrument for its full value and ship prepaid. We are not responsible for damage in transit. We do not accept COD shipments or cover any incoming freight or duty charges on returned merchandise. Turnaround time on repairs is approximately two weeks. We will call you with an estimate if you specifically request one, or if we determine that the meter may be too costly to repair. Non-warranty repairs will be returned via UPS/COD unless you have already established other payment terms. There is no COD service outside the U.S. To pay by credit card, include the card number and expiration date with your repair. We accept Visa/MasterCard, and American Express. 6 of 6

Warranty repairs will be returned at no charge if shipped within the U.S. via UPS Ground Service. Freight charges for expedited services (i.e., Federal Express, UPS/2 Day, UPS/1 Day, etc.) are the customer s responsibility and will be charged as per the above terms. WARRANTY: Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its HT- 3000 meter for one year from date of purchase. If, within the warranty period of the meter, you find any defect in material or workmanship return the meter following the instructions in the Service for Your Meter section. This limited warranty does not cover abuse, alteration, misuse, damage during shipment, improper service, unauthorized or unreasonable use of the meter or electrodes. This warranty does not cover batteries. If the meter has been tampered with, the warranty shall be void. At our option we may replace or repair the meter. Delmhorst shall not be liable for incidental or consequential damages for the breach of any express or implied warranty with respect to this product or its calibration. With proper care and maintenance the meter should stay in calibration; follow the instructions in the Care of Your Meter section. Under no circumstances shall Delmhorst be liable for any incidental, indirect, special, or consequential damages of any type whatsoever, including, but not limited to, lost profits or downtime arising out of or related in any respect to its meters or electrodes and no other warranty, written, oral or implied applies. Delmhorst shall in no event be liable for any breach of warranty or defect in this product that exceeds the amount of purchase of this product. The express warranty set forth above constitutes the entire warranty with respect to Delmhorst meters and electrodes and no other warranty, written, oral, or implied applies. This warranty is personal to the customer purchasing the product and is not transferable. Delmhorst Instrument Co. 51 Indian Lane East Towaco NJ 07082 (800)-222-0638 www.delmhorst.com e-mail - info@delmhorst.com For over 56 years, Delmhorst has been the leading manufacturer of high-quality moisture meters. Today we offer the innovative KIL-MO-TROL in-kiln monitoring system, and a complete line of portable moisture meters for woodworking/lumber, agriculture, construction and paper. 5/03 7 of 7