Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Similar documents
Level One Electric Vehicle Charging Station Wall Mount Product Guide

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

LEV/Wn Building A Connected World

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician.

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

User Manual. Posture+ Adjustable Base. For customer service call:

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Installation Instructions

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

SUBMERSIBLE SUMP PUMPS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

37SCENE 46SCENE 79SCENE

Installation and Operation Instructions Safety Director Arrow

HBC-20 - LED HIGH BAY

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Installation Instructions Model: AB Single-lever Pull-down Spray Faucet

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Harvil 4 Foot Air Hockey Table

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

SUBMERSIBLE SUMP PUMPS

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

ASSEMBLY AND INSTALLATION INSTRUCTIONS

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Installation Instructions Model: AB Single-Lever Pull-out Kitchen Faucet


Installation Instructions

USER GUIDE TURBOCORD TM PORTABLE CHARGER 240V. AeroVironment EV Solutions

Use and Care Guide.

PUSH BUTTON KEY CABINET

LED Convertible Dual Fixture Work Light on Tripod Stand

MaxLite LED Linear HighBay Fixtures

Installation Instructions

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

INSTALLATION & OWNER'S MANUAL

9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Model FM2260 Wall Mount. Full Motion Television Wall Mount

PIAA Multi-Fit 005/1100X Light Bracket Kits

Model Numbers SAVI-NOTE75, SAVI-NOTE150

CT4880 Collaboration Huddle Table Assembly Instructions

Installation and Operation Manual

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

SPC-PANEL Simplex, Single Phase Pump Control Panel

Thank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment.


Harvil 5 Foot Air Hockey Table

Cargo Cover. Installation Instructions. For: Wrangler Part Number: Installation Tips WARNING

LED LARGE WALL PACK (CUTOFF & STANDARD)

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

OWNER S MANUAL CAMBRO CAMDUCTION COMPLETE HEAT CHARGER.

WARNING ATTENTION. Please read this information carefully before operating your safe.

MOTORIZED FOLDING CAMPER WINCH

SUPER PUMP OUT SYSTEM

WINDOW AIR CONDITIONER SUPPORT BRACKET

PVI 60KW, PVI 82KW, PVI 95KW

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

SYSTEM MANUAL. Automated Motorized Hydraulic Traffic Controller. Revision CS72-HTC

OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual

TPAK Series COOLANT PUMP

Installation Instructions BULL BAR (Part # 51033&51034) SIERRA 1500 / SILVERADO 1500

HALLMARK INDUSTRIES INC

Environmental Series Air Curtains

HARDWARE KIT INSTALLATION GLOVES

FOLD N STORE. Table Tennis Table. Assembly Instructions Model DS, DS CONTACT INFO Hours.

Installation Instructions / Warranty

Cambro Camtherm OWNER S MANUAL. Plate Heater.

Compressor Clutch Replacement Procedure

Read this entire manual before operation begins.

VICTORY TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

Installation Instructions / Warranty

ADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS

Charging with AC (wall) Charger

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Wireless Dimmer Installation and User Guide

Safety Sentry Electronic Breakaway Switch

POWER GEAR SLIDE-OUT MANUAL

INSTALLATION INSTRUCTIONS MECHANICAL GAUGES

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

Transcription:

Level One Electric Vehicle Charging Station FREE STANDING Product Guide Model # SC2-120 Shorepower Technologies 2351 NW York St. Portland, OR 98664 503-892-7345 info@shorepower.com www.shorepower.com

2

Table of Contents 1. Warnings 2. Installation & Mounting 3. Use 4. Maintenance & Cleaning 5. Troubleshooting 6. Features & Specifications 7. Accessories 8. Warranty 9. Other Shorepower Products P.2 P.4 P.9 P.10 P.11 P.12 P.13 P.14 P.15 3

Installation & Mounting 1. Prepare Concrete Pad. If the pad has already been poured: a. Drill appropriate sized holes for concrete anchor Studs b. Set Anchor studs (See Diagram for Bolt Pattern If Concrete Pad has not already been poured: a. See recommended footer layout in diagram 2 b. Set J bolts in displayed bolt pattern. 4

2. Install Base Plate. Place the base plate over the new anchor studs or J bolt studs in the concrete pad. Fasten the included washers and nuts and torque to the recommended torque specification. 3. Mount the Charging Station to the Base Plate. Carefully lower the charging station over the Base Plate mounting studs. From within the station, fasten the four included flat washers and nuts to the Base Plate Studs 5

4. Attach incoming line power to distribution blocks. Feed power lines through base Plate into distribution blocks. Tighten Allen head set screws to recommended torque specifications. (Use appropriate sized conductors for minimum rating of 50 amps, 100 amp conductors recommended for level 2 charging) G L1 N L2 6

9. Optional Globe Installation. a. Unpack globe assembly. b. Install globe lenses. Lay globe assembly on a flat surface. c. Gently lay the lens into globe paying attention to alignment d. Insert the lock ring into the globe. Place the open ends of the ring toward the bottom and insert the ring into top half of globe. Press ring down and in around globe circumferences until ends meet. Ring should snap into place, locking lens in position. e. Gently flip Globe over and repeat steps c. & d. for the second lens. 7

f. Insert the globe assembly into the charging station, first feeding the wires through the holes on the top of the station. Then, guiding the threaded rod through the center hole. g. Fasten the included hardware from inside the station in this order: a. Angle adapter (the aluminum cylinder with the angle cut on one side) b. Lock washer c. Nut Connect the three wires to the wire nutted extension within the charging station Switch on lighting circuit breaker to test lighting fixtures. Light should remain on for 30-60 seconds in lighted areas. In dark areas, fixtures should stay lit indefinitely. 8

9

Use Shorepower Level 1 Charging Stations work like any standard 120 volt oulet with one exception. We recommend that the circuit breaker for the specific outlet you intend to use, be shut off prior to plugging in. Once plugged in, you can then switch the circuit breaker back on and commence charging. 1. Switch Circuit Breaker to the Off Position 1 2. Plug extension cord into Charging Station Outlet 3. Switch Circuit Breaker to the On Position 2 Reverse the process for disconnecting from charging station. 3 10

Maintenance & Cleaning Regular maintenance is not generally required on Shorepower Charging Stations. However you may find the need to replace the illumination bulb within the Unit. To do so, follow these simple steps: 1. Shut off main power service to Charging Station 2. Open Station Access Panel by removing the security screws from the back of the station. 3. Grasp Bulb with soft cloth and turning counter clockwise until the bulb becomes free 4. Replace bulb with same compact fluorescent or equivalent incandescent 5. The bulb in the globe and also be changed by removing either of the glass domes. (see dome installation instructions) Cleaning: Use a soft damp cloth with a mild detergent to wipe exterior of unit with main power service off Standard Stainless Steel polish can be used on the exterior as needed User Serviceable Light Bulb User Serviceable Light Bulb 11

Troubleshooting Problem: Charging Station Does not Light Up 1. Shut power to station off. 2. Open charging station by removing the security screws from the back of the station. 3. Verify that the lighting circuit breaker mounted on the back panel is switched to the on position. 4. Remove the light bulb and test it a known good standard light fixture such as a table lamp. 5. If the light still does not illuminate, replace the bulb. Problem: Charging Station does not charge Vehicle (No Power Output) 1. Verify all Circuit Breakers are in the on position. 2. Verify no circuit breakers have been tripped by switching them to the full off position then back to the on position. 3. Verify that the GFCI trip has not been set. Press the reset button and re-test. 4. If there is still no power, verify that the main power to the station is on. 5. WARNING, SHOCK DANGER! Open charging station door and measure voltages at L1 and L2 of the Charging stations main input buss. You should read 110v 120v between L1 and N and L2 and N. If no power is found, you have a main supply issue. Problem: Circuit Breaker will not stay On 1. If the circuit breaker will not stay in the on position, please disconnect any cords you may have connected and try and reset the breaker again. 2. If the problem no longer exists, check your cords and vehicle for short circuits and chargers that are pulling current than the breaker will allow. 3. If the problem still exists, replace the circuit breaker in question. 12

Features & Specifications Input Power Recommended 240 Volt or 208 Volt, 100 amp (min. 50 amp) 4 Wire Circuit Output Power 4 Level 1 GFCI 120 Volt 20 Amp Outlets (NEMA 5-20R) One Station Serves up to 4 Vehicles Material Stainless Steel Outdoor Rating NEMA Dimensions H20 x W16 x D9 Weight 40 Pnds apx. Visibility Upgradability Warranty Safety Backlit Outlets and Shorepower Logo for Nighttime Visibility Fully Upgradable to future Level 2, SAE J1772 Standards, with corded Connector Full 10 Year Warranty against Defects in workmanship and materials. (Excluding Outlets) Hi Visibility Ground Fault Circuit Interrupt equipped Outlets 13

Accessories Payment and Monitoring Control System Shorepower Accessory payment and monitoring control system allows owners to: Optionally charge customers for use of the charging station Switch Power ports on and off via our web interface Meter power usage per individual power outlet and access Statistical data via our web interface Call Shorepower Technologies for Pricing and detailed information 503-892-7345 14

Warranty Limited Warranty Shorepower Technologies warrants its factory-installed wall mount charging station, free standing charging station, and TSE Pedestals to be free from failure due to defects in material and workmanship under normal care and proper usage in a residential installation which fully complies with all National Electrical Code requirements for a period of 1 years from the date of installation. In the event the product fails to comply with this warranty, Shorepower Technologies will, at its option, either repair or replace the product at without charge. To obtain warranty service the purchaser should return the product to the place of purchase or deliver the product prepaid to Shorepower Technologies at the address set forth below. Proof of purchase in the form of a receipt or invoice, which is evidence that the unit is within the warranty period, must be presented to obtain warranty service. Shorepower Charging Stations Additional Information These warranties do not cover failure or damage due to improper storage, installation, operation, maintenance, accident, misuse, abuse or negligence. These warranties do not cover reimbursement for labor, transportation, gaining access, removal, installation, temporary power, or any other expenses that may be incurred in connection with repair or replacement of the Shorepower Technologies products. The remedies as provided under these warranties are the exclusive remedy of the purchaser and the limit of the liability of Shorepower Technologies with respect to these products, whether in contract, in tort (including negligence or strict liability) or otherwise. Shorepower Technologies disclaims all other warranties, including without limitation any implied warranty of merchantability or of fitness for a particular purpose, and shall not be liable for any incidental or consequential damages. With respect to products purchased by consumers of the United States for personal use, the implied warranties, including but not limited to the warranties of merchantability and of fitness for a particular purpose, are not excluded but are limited to the duration of the warranty period. Some states do not allow the exclusion or limitation of incidental or consequential damages or implied warranties, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. All product warranties are rendered null and void if a breaker other than those specifically listed by UL for use in this type SC2-120 product is installed. SHOREPOWER TECHNOLOGIES WARRANTY DEPARTMENT 2351 NW York St. Portland, OR 97210 15

Other Shorepower Products Level 1 & 2 Wall Mount EV Charging Stations Truck Stop Electrification Pedestals 16

Addendum If you purchasing a globe kit after purchasing the standard station you will need to move the light sensor into the globe adapter. Light Sensor install 1. Remove light sensor from station by unscrewing the three wire nuts and the plastic nut on top of the station 2. Place the included spacer onto the sensor head 3. Insert the light sensor into the globe adapter so that the wires extend sideways 4. Place the rubber washer over the sensor head and install the plastic nut and tighten 17