Meter Mounting Equipment. Northern Indiana Public Service Co.

Similar documents
Meter Mounting Equipment DTE Energy Area

Meter Mounting Equipment Wisconsin Area

MEG Approval Meter Equipment Group

Wisconsin Area Catalog

Meter Mounting Equipment Florida Area Catalog

Duke/MEG Approval Meter Equipment Group

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

ComEd Service Area Meter Mounting Equipment

Meter Mounting Equipment Commonwealth Edison

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

Indiana Meter Mounting Equipment

REC Municipal Meter Mounting Equipment

Meter Mounting Equipment. GA/AL/FL Panhandle Area

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

Ohio Meter Mounting Equipment

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,

Louisiana/Mississippi. Area Catalog

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market

Meter Mounting Equipment

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Recreational Vehicle Park Electrical Products & Accessories

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Instrument Rated Metering Equipment

Louisiana & Mississippi Area Catalog

Ameren Service Area Product Catalog

Tennessee Area Meter Mounting Equipment

PSE&G Long Island Meter Mounting Equipment

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Upstate New York Meter Mounting Equipment

Ameren Service Area Product Catalog

Consolidated Edison Orange & Rockland Meter Mounting Equipment

New York City Apartment Metering Meter Sockets / Load Centers

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents

AMENDMENT ELECTRIC SERVICE MANUAL 2014

5.2. Power Pedestals. Contents Description

6.2. Power Pedestals. Contents

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Introduction. Upon completion of Basics of Meter Mounting Equipment

Contents. Volume 1 Residential and Light Commercial CA E December

10 Commercial, Industrial, Agricultural Services

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

MP Meter-Pak Meter Centers

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

A. Submit manufacturer's literature and technical data before starting work.

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

DISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual

Multiple Metering, Horizontal Gang - Non Lever Bypass

Selection and Application Guide For use in New England EQUIPMENT

Customer Requirements Meter Socket Configurations

COMMERCIAL QUICK REFERENCE

Selection and Application Guide. Meter Mounting Equipment. For use in Iowa and Nebraska.

CT Metering. CT Metering. Meter Mounting Equipment

Modular Metering Application Guide

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

Design Standard. Purpose: Design Standard:

The Reliable Choice. Field Pocket Guide

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

WPS SERVICE MANUAL. Section Amp and Smaller - Common

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Multiple Metering, Vertical Gang

6.1 Introduction Product Description... Application Description... Optional Features...

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

10. METERING General Requirements

Group Meter Main - Without Bypass

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Meter Centers Meter Mounting Devices

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

UNDERGROUND SERVICES - SECONDARY

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

SECTION PANELBOARDS

Modular Metering Construction Details

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Accessories. Accessories. Meter Mounting Equipment

Section 6 Electric Metering: Residential

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

Volume 1 Residential and Light Commercial CA E December

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

(CT, NH, ME, RI, VT, MA)

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Solar Combiner Solutions

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

Transcription:

Meter Mounting Equipment Northern Indiana Public Service Co.

MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank Quality Metering Products for over 7 Years Milbank Manufacturing Company was established in 97 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 9 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank s employee base of over,000 with our five manufacturing facilities comprising almost 0,000 square feet gives us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 0,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs and related accessories. If you don t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is an important factor to remain competitive in today s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for over 7 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE!

TABLE OF CONTENTS LOGIC......................................................................... DISCONNECTS AIR CONDITIONER DISCONNECT.................................................................. AIR CONDITIONER DISCONNECT WITH GFCI RECEPTACLE........................................... HOT TUB DISCONNECT.......................................................................... SINGLE POSITION (HORN BY) AMP TERMINAL RINGLESS 00 VAC.........................................................7 00 AMP TERMINAL RINGLESS 00 VAC.........................................................8 00 AMP TERMINAL SIDE WIREWAY RINGLESS 00 VAC...........................................8 TABLE OF CONTENTS SINGLE POSITION (LEVER BY) 00 AMP & 7 TERMINAL HEAVY DUTY RINGLESS 00 VAC.........................................9 0 AMP TERMINAL HEAVY DUTY RINGLESS 00 VAC............................................0 0 AMP CONTINUOUS 7 TERMINAL HEAVY DUTY RINGLESS 00 VAC............................... MULTIPLE POSITION 00, 0 & 00 AMP / POSITION TERMINAL HORIZONTAL GANGS RINGLESS 00 VAC................. 00 AMP / POSITION 7 TERMINAL HORIZONTAL GANGS HEAVY DUTY RINGLESS 00 VAC.............. CONDOMINIUM METERING BANKS & 00 AMP / POSITION VERTICAL & RECTANGULAR 0 / 0 VAC..............................- PEDESTALS 00 & 00 AMP TERMINAL RESIDENTIAL SINGLE OR DOUBLE POSITION RINGLESS-00 VAC........... 00 / 00 AMP & 7 TERMINAL LEVER BY HEAVY DUTY 00 VAC...............................7 METER-MAIN / CIRCUIT BREAKERS 00 / 00 AMP TERMINAL CB MAIN DISCONNECT RINGLESS 0 / 0 VAC..........................8 00 / 00 AMP TERMINAL METER PEDESTAL RINGLESS PARALLEL MAIN 0 / 0 VAC...............9 0 AMP TERMINAL WITH BREAKER LEVER BY HEAVY DUTY RINGLESS 0 / 0 VAC..........0 0 AMP TERMINAL NO BREAKER PROVISION LEVER BY HEAVY DUTY RINGLESS 00 VAC......0 RV / MOBILE HOME PEDESTAL 00 AMP TERMINAL RINGLESS 0 / 0 VAC.................................................... MISCELLANEOUS ACCESSORIES..............................................................................- CONDUIT AND AMPACITY INFORMATION.......................................................... ENERGIZATION OF ELECTRICAL EQUIPMENT...................................................... MATERIALS AND FINISHES...................................................................... WATTHOUR METERS...........................................................................7 OTHER MILBANK PRODUCTS....................................................................8 INDEX.............................................................................................9

LOGIC LOGIC

0 & 0 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS DISCONNECTS U800 (No deadfront required) U80 PROFILE Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and also complies with article 0- in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. TECHNICAL INFORMATION U80 0 & 0 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS AMP TYPE MAX H.P. WT. # 0 FUSIBLE U80.7 0 FUSIBLE U80 0.7 0 NONFUSIBLE U800 0. & LOAD WIRE RANGE GROUND WIRE RANGE WIRE RATING CU AL CU C AL C #-# AWG #-# AWG #- AWG 9 0 /7 0 #-# AWG #-# AWG #- AWG 9 0 /7 0 #-# AWG #-# AWG #- AWG 8 0 /7 0 /7 U800 is UL Listed without deadfront. Line and load terminations are fully insulated. U80 & U80 std. quantity is per carton. U800 std. quantity is 0 per carton.

AC DISCONNECT / SPA BOX AC DISCONNECT / SPA BOX DISCONNECTS AMP Combination AC Disconnect / 0 Amp GFCI Receptacle Together in Box TYPE U8-0GR MAX H.P. 0 amp, Non-Fused AC Disconnect Duplex 0 amp GFCI Receptacle Type R Enclosure with In-Use Cover WT. # 0 NONFUSIBLE U8-0GR 0 Meets NEC # 0. Requirements * UL Listed as Power Outlet Type R Enclosure In-Use Cover** Duplex Ground Connector Concentric Knockouts AC DISCONNECT, 0 Volt 0 amp, Non-Fused GFCI RECEPTACLE 0 amp & LOAD CONNECTOR WIRE RANGE Reset/Test Button Padlock provision CU AL #-# AWG #-# AWG * NEC #0. Heating, Air- Conditioning and Refrigeration Equipment Outlet....The receptacle shall be located on the same level and within 7. m ( ft.) of the heating, airconditioning and refrigeration equipment. * NEC #0.08 Ground-Fault Circuit Interruptor protection for personnel. GROUND CONNECTOR WIRE RANGE WIRE RATING #- AWG CU C AL C.8. 7. 0 /7 0 /7 To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U8-0GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). *Reprinted with permission from NFPA 70-00, National Electrical Code, Copyright 00, National Fire Protection Association, Quincy, MA 09. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Spa Box with GFCI Protection U88-O-0GB 0 volt ground fault protection UL listed, Type R rainproof Milbank reliability Easy installation pole, 0 amp GFCI breaker protection Compact size: 8-/ H x 7-/ W x -/ D or wire installation, 0 / 0 VAC Standard package of extra one-pole breaker spaces 00 amp overall rating Sub Panel Breaker Enclosure Use as a 00 amp, circuit sub panel enclosure U88-O has provision for () -pole or () -pole small frame breakers AMP 0 0 TYPE WT. # BREAKER PROVISION U88-O 7 BREAKER BREAKER U88-O-0GB U88-O-0GB 8 8 & LOAD CONNECTOR WIRE RANGE GROUND CONNECTOR WIRE RANGE CU AL #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 7 8 7 8 7 8

AMP TERMINAL RINGLESS 00 VAC 7 SINGLE POSITION 787 U787-RL-TG-KK AMP TERMINAL RINGLESS 00 VAC AMP TERMINAL* RINGLESS W SERVICE AMP CONNECTORS OH U787-RL-TG-KK H.O. #-/0 HORN 8 S: For proper hub selection see the hub suffix chart on the accessory page. BY: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral. *FIFTH TERMINAL: For field mounted fifth terminal, order catalog number TR. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7

8 00 AMP TERMINAL RINGLESS 00 VAC 00 AMP TERMINAL RINGLESS 00 VAC SINGLE POSITION SERVICE U70-RL-TG-KK CONNECTORS LOAD OH U70-RL-TG-KK H.O. #-0 #-0 HORN 00 AMP TERMINAL RINGLESS 8 8 OH U899-RL-TG-KK H.O. #-0 #-0 HORN 8 8 OH/UG U700-RL-TG-KK H.O. #-0 #-0 HORN 8 S: For proper hub selection see the hub suffix chart on the accessory page. FIFTH TERMINAL: For field mounted fifth terminal for U899, U70 & U700, order catalog number KT. 70 CONNECTORS: Extruded aluminum connectors are tin plated. U700-RL-TG-KK GROUND: For indoor service for U899 order as extra catalog number BL08-KK block assembly to be installed to provide insulated neutral. 980 700 899 U980-O-KK,, 00 AMP TERMINAL SIDE WIREWAY RINGLESS AMP SERVICE CONNECTORS LOAD 00 UG U980-O-KK BLANK #-0 #-0 HORN, FIFTH TERMINAL: For factory installed fifth terminal in the 9 o clock position add the suffix -T. For field mounted fifth terminal order catalog number KT. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with triplex neutral. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8

00 AMP & 7 TERMINAL LEVER BY HEAVY DUTY RINGLESS 00 VAC 9 90 9700 SINGLE POSITION AMP 00 SERVICE 00 AMP TERMINAL RINGLESS W CONNECTORS LOAD OH U90-RL* H.O. #-0 #-0 LEVER 7 8 0 8, 00 UG U9-O* BLANK #-0 #-0 LEVER 7 8 9 *Grounded B phase (may be field isolated). S: For proper hub selection see the hub suffix chart on the accessory page. BY: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground. FIFTH TERMINAL: Fifth terminal is supplied in the o clock position. For factory installed fifth terminal in the 9 o clock position add the suffix -T9 to the catalog number. AMP 00 SERVICE U90-RL CONNECTORS LOAD OH U9700-RRL H.O. #-0 #-0 LEVER 9 970 00 AMP 7 TERMINAL RINGLESS W 7 8 0 8 U970-O,, 00 UG U970-O BLANK #-0 #-0 LEVER 7 8 9, 00 AMP & 7 TERMINAL LEVER BY HEAVY DUTY RINGLESS 00 VAC S: For proper hub selection see the hub suffix chart on the accessory page. BY: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground. INSULATED NEUTRAL: For field installed insulated neutral for the U970 order kit number K07. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9

0 0 AMP TERMINAL LEVER BY HEAVY DUTY RINGLESS 00 VAC 0 AMP TERMINAL LEVER BY HEAVY DUTY RINGLESS 00 VAC SINGLE POSITION SERVICE U000-O-KL-KL OH U779-RRL H.O. CONNECTORS #-00 () /0-0 /8 - STUD LOAD TWIN #-0 /8 - STUD LEVER 7 8 8 UG U000-O-KL-KL BLANK K8 LEVER 7 8 0 0 AMP TERMINAL RINGLESS W 00 VAC T KIT K8 S: For proper hub selection see the hub suffix chart on the accessory page. BY: Lever supplies clamping action and also operates bypass device. CONNECTORS: Stud type units supplied with /8 - hex head nuts with Belleville washers. For connector kits, order as extra K0 (00 ). For twin lug connectors order as extra K0 (0 ). U000-O-KL-KL uses K0L (single 00) or K0L (twin 0) non-rotating connectors for load side. Separate kits are required for both line and load. FIFTH TERMINAL: For factory installed fifth terminal in the o clock position add the suffix -T to the catalog number. For factory installed fifth terminal in the 9 o clock position at the suffix -T9 to the catalog number. For field installed fifth terminal, order as extra K8. 000 779 KO right side only U779-RRL (shown with optional hub installed),, Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 0

0 AMP CONTINUOUS 7 TERMINAL LEVER BY HEAVY DUTY RINGLESS 00 VAC 0 AMP CONTINUOUS 00 AMP MAX. SINGLE POSITION AMP 0 SERVICE OH/UG U9-X-K7-INV (Shown without lugs) U9-X-K7-INV C.P. CONNECTORS #-00 LOAD /8 - STUD LEVER 0 AMP SIDE WIREWAY 7 TERMINAL RINGLESS W 9 8 S: For proper hub selection see the hub suffix chart on the accessory page. BY: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Type K7 single barrel 00 (catalog number K) line side lugs included. For load side lugs, stud type units are supplied with /8 - hex head nuts with Belleville washers. For single lug connector kits, order as extra K (00 ). For twin lug connectors order as extra K (0 ).. 9,, 0 AMP CONTINUOUS 7 TERMINAL LEVER BY HEAVY DUTY RINGLESS 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 & 00 AMP / POSITION TERMINAL HORIZONTAL GANG RINGLESS 00 VAC SIDE WIREWAY OH/UG SERVICE L7-XL-KK U-X-KK (Shown with optional line side connectors) MULTIPLE POSITION 00 & 00 AMP / POSITION TERMINAL HORIZONTAL GANG RINGLESS 00 VAC NO. OF POS. AMPS 00 00 00 00 00 NO. OF POS. L7-7 - 00 AMP / POSITION TERMINAL RINGLESS W OVERHEAD 00 VAC 0 & 00 AMP / POSITION TERMINAL RINGLESS W OH/UG 00 VAC L7-XL-KK C.P. CONNECTOR /8 - STUD /8 - STUD /8 - STUD /8 - STUD /8 - STUD CONNECTOR #-0 #-0 #-0 #-0 #-0 LOAD #-0 #-0 #-0 #-0 #-0 LOAD #-/0 : For proper hub selection refer to the hub suffix chart on the accessory page. For the U & U units, two hub openings are supplied and the extra opening is closed with a closing plate as standard. FIFTH TERMINAL: For field mounted fifth terminal order catalog number KT for 9 o clock position. *CONNECTORS: Extruded aluminum connectors are tin plated. Units supplied with /8 hex head nuts with Belleville washers on line side. Order connector kit K (00 ) as extra. BUSSING: Refer to the Conduit & Ampacity Section on page of this catalog for information on ampacity of bussing. FOR OVERHEAD SERVICE: The U, U, and the U units are factory assembled for underground service. If overhead service is desired an extension kit is required; order catalog number K9 for the U and U units, and K9 for the U unit. For factory installed overhead service add suffix -EX to the catalog number. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7 7 U-X-KK* C.P. HORN 8 U-X-KK* C.P. HORN 8 U-X-KK* C.P. HORN 8 7 8 U-X-KK* C.P. HORN 8 7 8 U-X-KK* C.P. HORN 8 7 8 8 HORN D W 0 H, L7-XL-KK C.P. HORN #-/0, 8 L7-XL-KK C.P. HORN #-/0, 0 L7-XL-KK C.P. HORN #-/0, 8 7 8 L7-XL-KK C.P. HORN #-/0, 7 CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Supplied with / x aluminum bussing. FIFTH TERMINAL: For field installed fifth terminal, order as extra catalog number T8K for the o clock position, and Kit #K999 for the 9 o clock position. EXTRA WIRE SPACE: Extra wire space of provided on the left end of and position gangs. Furnished on both ends of,, and position gangs. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information page in this catalog. BY: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers.

00 AMP / POSITION 7 TERMINAL HORIZONTAL GANGS LEVER BY HEAVY DUTY RINGLESS 00 VAC CENTER WIREWAY U7-XT-PED (shown without pedestal) MULTIPLE POSITION AMPS 00 00 00 SERV. OH/UG OH/UG OH/UG NO. OF POS. 00 AMP 7 TERMINAL RINGLESS W OVERHEAD / UNDERGROUND* U7-XT-PED ()C.P. CONNECTOR /8 - STUD /8 - STUD /8 - STUD LOAD #-0 #-0 #-0 LEVER D W 8 H PED, U7-XT-PED ()C.P. LEVER PED, U7-XT-PED ()C.P. LEVER PED, S: Units supplied with two closing plates. To order hubs as extra refer to the hub suffix chart on the accessory page. BY: Lever supplies clamping action on meter spades and also operates bypass device. *CONNECTOR KITS: Line wire sections supplied with studs. For connector kits order K08 (single-0 ), K (single- 00 ), or twin K (twin-0 ) or K08 (twin-00.) Line connectors can be reversed to change from OH to UG service. *UNDERGROUND PEDESTALS: For underground service order S9-TO pedestal raceway. A pedestal extension kit is also available. Order catalog number S7. BUSSING: Bussing is /8 x aluminum. Refer to the conduit & ampacity page of this catalog for information on ampacity of bussing. 00 AMP / POSITION 7 TERMINAL HORIZONTAL GANGS LEVER BY HEAVY DUTY RINGLESS 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

CONDOMINIUM METERING BANKS RINGLESS OH/UG SERVICE W 0 / 0 VAC U8-X-PED-KK (Order breakers and pedestal raceway as extra) U8-X (Shown without pedestal) VERTICAL AMP/POSITION 00 AMP/POSITION CONDO MTR. BANKS CONDOMINIUM METERING BANKS RINGLESS OH/UG SERVICE W 0 / 0 VAC NO. OF POS. NO. OF POS. U8-X-KK-K-PED U8-X-KK-K-PED U8-X-KK-PED U8-X-KK-PED MAIN BUS RATING 00 amp 00 amp MAIN BUS RATING 00 amp 00 amp CONNECTOR SIZE #-0 #-0 CONNECTOR SIZE */8 - STUD */8 - STUD U8-X-KK-PED 00 amp */8 - STUD SIZE SINGLE TWIN SUFFIX -K -K -K -K K9 K0 K0 K U8- U8- U8- U8- U8- U8- NO. OF POS. NO. OF POS. U8-X-KK-K-PED U8-X-KK-K-PED U8-X-KK-PED U8-X-KK-PED MAIN BUS RATING 0 amp 00 amp AMP/POSITION 00 AMP/POSITION CONNECTOR KITS * KIT COMPATIBLE WITH U8- RECTANGULAR WIRE RANGE #-0 #-00 #-0 #-00 MAIN BUS RATING 00 amp 00 amp CONNECTOR SIZE #-0 #-0 CONNECTOR SIZE */8 - STUD */8 - STUD U8-X-KK-PED 00 amp */8 - STUD *CONNECTORS: For line wire connector kits, order separately. FIFTH TERMINALS: For field mounted fifth terminal order catalog number K8. Order one per meter position (9 o clock position only). BREAKERS: Units have provision for one double pole main per meter position. Breakers not included, order as extra Milbank type Q or QNR or comparable. Refer to the accessories section in back of catalog. UNDERGROUND SERVICE: For underground service order S9-TO pedestal raceway. Order separately. PEDESTAL EXTENSION KIT: A pedestal extension kit is also available. Order catalog number S7. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

CONDOMINIUM METERING BANKS RINGLESS OH/UG SERVICE W 0 / 0 VAC CONDOMINIUM METERING BANKS VERTICAL with pedestal option in bottom amp/pos. (- position) 00 amp/pos. (- position) D D U8-X " or 7" 9" or " FIG. A CONCENTRIC K.O. A A A PED -7/8" B C D E PEDESTAL OPTION Pedestal Raceway S9-TO PED, CONCENTRIC K.O. CONCENTRIC K.O. OPENING CONCENTRIC K.O. PEDESTAL OPTION Pedestal Extension Unit S7 FIFTH TERMINAL # K8 (-00 amp) A A A C 8" amp/pos. (, & position) " or 7" PED A A A -7/8" " E E E E " PED RECTANGULAR with pedestal option in bottom C " -7/8" 00 amp/pos. (, & position) E E PED E E E 9" or " -7/8" CONDO MTR. BANKS CONDOMINIUM METERING BANKS RINGLESS OH/UG SERVICE W 0 / 0 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 / 00 AMP TERMINAL RESIDENTIAL PEDESTAL SINGLE OR DOUBLE POSITION W 00 VAC 00 / 00 AMP TERMINAL RESIDENTIAL PEDESTAL SINGLE OR DOUBLE POSITION W 00 VAC U8-O GRADE 8.00 Extension Unit K800 PEDESTALS AMP SERVICE 00 / 00 AMP TERMINAL CECHA APPROVED RINGLESS W 00 VAC CONNECTORS LOAD 00 UG U8-O BLANK /0 Crimp-On #-0 HORN 8 9 HANGING HOOK: Supplied with keyhole hanger for easy mounting. EXTENSION UNIT: For burial applications, order extension unit K800; for 0 applications, order () K800 units. FIFTH TERMINAL: For field installed fifth terminal, order catalog number KT (9 o clock position). BY: Horn type bypass. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.

00 / 00 AMP & 7 TERMINAL LEVER BY HEAVY DUTY PEDESTAL 00 VAC 7 PEDESTAL EXTENSION UNIT S88 MILBANK # OF TERMS U908-O 908 907 SERVICE UG BLANK CONNECTORS /0-/0 LOAD #-0 LEVER U907-O 00 / 00 AMP TERMINAL HEAVY DUTY -W OR -W 8 00 / 00 AMP & 7 TERMINAL LEVER BY HEAVY DUTY PEDESTAL 00 VAC # OF TERMS 7 U907-O 00 / 00 AMP 7 TERMINAL HEAVY DUTY W SERVICE UG BLANK CONNECTORS /0-/0 LOAD #-0 LEVER 8 PEDESTALS BY: Lever supplies clamping action on meter spades and also operates bypass device. BOTTOM PLATE: Bottom plate is not furnished with this unit. However, if plate is required, order catalog number S97 as extra. NEUTRAL: The U908-O is supplied with a center disconnect neutral. EXTENSION KIT: For direct burial applications, order kit S88 as separate item. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7

8 00 OR 00 AMP CIRCUIT BREAKER MAIN DISCONNECT SINGLE POSITION METER MAIN 0 VAC M I L B A N K 00 OR 00 AMP CIRCUIT BREAKER MAIN DISCONNECT SINGLE POSITION METER MAIN 0 VAC METER MAINS U77-RL-KK U77-RL-KK U707-RL-00-KK 00 AMP TERMINAL METER MAIN (PLUG-IN) RINGLESS SERVICE OH SERVICE OH H.O. H.O. CONNECTORS LOAD #-/0 C.B. CONNECTORS #-0 LOAD #-00 HORN HORN 8 8 8 8 9 U707-RL-00-KK (Supplied with 00 Amp circuit breaker), CIRCUIT BREAKER: Main circuit breaker not supplied with unit. For 00 amp service order Milbank catalog number Q00 separately. See circuit breaker chart on accessory page for other compatible models. 00 AMP TERMINAL METER MAIN RINGLESS, CIRCUIT BREAKER: 00 amp main circuit breaker factory bussed. Order Milbank catalog number UQFB-00-X for replacement. Other amperages available. See Milbank circuit breaker chart on accessory page. S: Order hubs separately see accessory page for ordering information. FIFTH TERMINAL: For field mounted fifth terminal for U77 order catalog number T8K. For field mounted fifth terminal for U707 order catalog number KT. Mount in the 9 o clock position only. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8

00 / 00 AMP TERMINAL METER PEDESTAL PARALLEL MAIN 0 / 0 VAC 9 W/ BREAKER INSTALLED NU8980-O-00-KK 00 / 00 AMP TERMINAL C/B RINGLESS W UG 0K / K AIC RATING BLANK CONNECTOR #-0 KCMIL #-0 KCMIL #-0 KCMIL #-0 KCMIL LOAD C/B HORN NU8980-O-00-KK-LP BLANK C/B HORN NU8980-O-00-KK NU8980-O-00-KK-LP BLANK BLANK NU8980-O-KK C/B C/B HORN HORN MAIN BREAKER 0K UQFP UQFP UQFP UQFP K UQFPH UQFPH UQFPH UQFPH STD = 79" -LP = 70" STD = " -LP = " MILBANK Grade Line 9 79 9 70 9 79 9 70 MAIN CIRCUIT BREAKERS: For 0K AIC order with factory installed main. For K AIC order pedestal without main and order circuit breaker separately. All main breakers are parallel connected. For series wired main order wire kit K7 and UQFP-M type circuit breaker. See Milbank circuit breaker chart on accessory page. BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers <00 amp. See plug-in breaker compatibility chart on accessory page. FIFTH TERMINAL: For field installed th terminal order T8K. Mounts in 9 o'clock position only. BY: All pedestals have horn-type bypass installed for meter testing or replacement without interrupting customer service. EXTENSION KIT: Available for low profile (-LP) units only. Order kit K9. See accessory page. 00 / 00 AMP TERMINAL METER PEDESTAL PARALLEL MAIN 0 / 0 VAC METER MAINS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9

M I L B A N K 0 0 AMP TERMINAL METER MAIN LEVER BY HEAVY DUTY /00 AMP CB 0 AMP CONTINUOUS 00 AMP MAX 0 AMP TERMINAL METER MAIN LEVER BY HEAVY DUTY /00 AMP CB 0 AMP TERMINAL METER MAIN WITH BREAKERS RINGLESS 0 VAC W U89-O-/00-INV SERVICE UG BLANK CONNECTORS /8 X STUDS LOAD C.B. #- 00 LEVER 7 8 BREAKERS: Supplied from factory with double-pole, 00 amp Milbank UQFB-00 or UQFBH-00 (,000 AIC) bolt-on circuit breakers. * Must order K AIC breakers separately. Order Milbank UQFBH-00 breakers. CONNECTORS: The line wire section is supplied with /8 - studs with hex nuts and captive Bellville washers. For line side connectors, order as extra catalog numbers K9 (single-0 ), or K0 (single-00 ), or for twin K0 (twin-0 ). Order one kit per unit. EXTENSION KIT: For extension kit order as extra catalog number S88.. U89-O-/00-INV Grade Line 8" Grade Line -/" " " O.D. S88 Pedestal Extension Unit Grade Line -7/" I.D. 8" Grade Line U78-O-WI METER MAINS 0 AMP TERMINAL WITHOUT BREAKER PROVISION RINGLESS 00 VAC W U78-O-WI SERVICE UG BLANK CONNECTORS /8 X STUDS LOAD TWIN #- 0 LEVER 7 8 CONNECTORS: The line wire section is supplied with 8 studs with hex head nuts and captive Belleville washers. The line side connectors are to be supplied by the Utility, load side is furnished. BY: The lever supplies clamping action on the meter spade and also operates the bypass device. FIFTH TERMINAL: For field installed fifth terminal order kit number K8. PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit number S88. See accessory page.. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 0

00 AMP SERIES U & U7 RINGLESS METERED PEDESTAL U-O-00S UL Listed File E909. 00 amp maximum, 0/0 V, W. Ringless type meter socket with horn bypass and stainless steel latch. Short circuit withstand rating 0K AIC, for K AIC, order with suffix. Type R construction for durable outdoor use. Milbank grey polyester powder coat finish. Wire terminations accept copper or aluminum conductors. Line & Neutral: () #-0 per phase. Line Ground: () #-/0. Load (CB): /0 to 00 per pole. Load Neutral: () #-0. Load Ground: () #-/0, () #/. Commercial grade, plug-in main circuit breaker. Available in 00,, 0 & 00 amp. Type UQFP-M. circuit plated copper interior accepts () -pole or () -pole standard plug-in type circuit breakers. Branch circuit rated to amps max. Acceptable manufacturers: Milbank, Cutler-Hammer, GE or Siemens. Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories. SINGLE PEDESTAL # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs) U-O-00S UQFP-M-00 00 Circuit 8 U-O-00S UQFP-M-00 00 Circuit 8 U-O-00S/ UQFPH-M-00 00 Circuit 8 DOUBLE PEDESTAL # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs) U7-O-00S () UQFP-M-00 Series 00 Circuit U7-O-00S () UQFP-M-00 Series 00 Circuit U7-O-00S/ () UQFPH-M-00 Series 00 Circuit RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (Sold separately) # RECEPTACLE CIRCUIT BREAKER CONDUCTOR CONFIGURATION K00-0 -0R Duplex 0 amp, Pole Awg RV/MH 00 AMP SERIES U & U7 RINGLESS METERED PEDESTAL K00-0GR -0R Duplex GFI 0 amp, Pole Awg GFI Rec. K00-TT0 TT0R 0 amp, Pole 0 Awg K00-0 -0R 0 amp, Pole 8 Awg K00-BRIDGE-POS Self-grounded one position receptacle bridge with hardware K00-BRIDGE-POS Self-grounded two position receptacle bridge with hardware K Stabilizer foot with hardware K0 Pad mount kit with hardware (see note below) KT th terminal for or 9 o clock position K9 Wire kit to convert series wired main breaker to parallel A maximum of two receptacle / circuit breaker kits can be installed in each power head. Order from above. Other kits available. Consult factory for factory-installed receptacle kits. Receptacle / circuit breaker kits include receptacle, circuit breaker, wire, cover plate and mounting screws. Receptacle bridge K00-BRIDGE-POS or K00-BRIDGE-POS not included with pedestal. Order separately. Pedestals are stocked with series wired main circuit breakers. Order K9 kit to field convert to parallel main lug circuit breaker. For parallel wired main circuit breakers, change S suffix to P (Ex.: U-O-00P). K Stabilizer Foot sold separately. Recommended for double pedestals. Pad mount pedestals available. Order U8 (single meter) or U9 (double meter) prefix. K0 pad mount kit required. Order separately.

MILBANK ACCESSORIES INTERCHANGEABLE UNIT S MILBANK ACCESSORIES MISC. ADAPTER PLATE (Converts opening to opening) S8 METAL CLOSING PLATE (for ringless sockets) CP- SUFFIX WL YL ZL DL EL CLOSING COVERS SMALL RL"OPENING (STANDARD) SIZE MILBANK NO. A7 A7 A7 A77 A78 METER CLOSING PLATE (Grey Plastic) 00 LARGE R OPENING (HEAVY DUTY) SUFFIX F G H SIZE MILBANK NO. A80 A8 A8 SUFFIX CHART O Plain Top WL For -RL Opening RL Small Hub Opening YL For -RL Opening R Large Hub Opening ZL For -RL Opening XL Small Closing Plate DL For -RL Opening X Large Closing Plate EL For -RL Opening Large Hub Opening F For -R Opening RXL adapted to small Closing Plate G For -R Opening RRL Large Hub Opening adapted to small Hub Opening H For -R Opening PEDESTAL EXTENSION UNITS REMOVABLE CLOSING PLATE DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) LARGE (for -R opening) -XL A7 -X A90 FOR CONDO METERING BANKS (-00 AMP) K8 S8988 S88 S7 S88 K9 K800 8 8 7 8 8 0 9 9 #K STAKE KIT Suitable for use with pedestals for extra support FIFTH TERMINALS PLUG-IN FIFTH TERMINAL T8K (Fits in round hole of old style block) BOLT-IN FIFTH TERMINAL TR (Fits in round hole of old style block) HEAVY DUTY JAW CLAMPING K8 FIFTH TERMINAL KT (Fits in square hole of new style 00 amp block)

MILBANK ACCESSORIES SINGLE CONNECTOR KITS For use with /8 - stud type units only TWIN DISCONNECT SLEEVE M- SUFFIX K K KL SUFFIX K K7 # ( per set) K9-0 K0-00 or () /0-0 -00 or K0L () /0-0 Non-rotating # K08 K ( per set) -0-00 or () /0-0 SUFFIX K KL K SUFFIX Replaces the load side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #-0 load-side connector. K0 Includes Safety Barrier Extensions for applications over 00 VAC. K977-INT INTERNAL HEX K0-INT INTERNAL HEX K K8 # K0 K0L K # K K08 ( per set) -0-0 Non-rotating -00 ( per set) -0-00 LOAD TAP CONNECTORS ( per set) ISOLATED NEUTRAL KIT K07 MISC. MILBANK ACCESSORIES ANTI-INVERSION CLIP SEALING RINGS K80 PLUG-IN BREAKER COMPATIBILITY CHART AMPS MILBANK CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) SIEMENS MURRAY / CROUSE-HINDS G.E. SQ-D -00 Q / QNR HQP / BR / WBJ Q / QN MD Q 00 Q QUICKLAG P / BR / HQP QP MP Q HOME SCREW TYPE MR- BUCKLE HASP MR-8 MILBANK -POLE 00 AMP LARGE FRAME 0,000 AIC &,000 AIC AMPS 0,000 AIC PLUG-IN,000 AIC PLUG-IN 0,000 AIC PLUG-IN,000 AIC PLUG-IN 0,000 AIC BOLT-ON,000 AIC BOLT-ON 0,000 AIC BOLT-ON 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 UQFB-00 UQFBH-00 UQFB-00-X UQFP- UQFPH- UQFP-M- UQFPH-M- UQFB- UQFBH- UQFB--X 0 UQFP-0 UQFPH-0 UQFP-M-0 UQFPH-M-0 UQFP-0 UQFBH-0 UQFP-0-X 7 UQFP-7 UQFPH-7 UQFP-M-7 UQFPH-M-7 UQFB-7 UQFBH-7 UQFB-7-X 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 UQFB-00 UQFBH-00 UQFB-00-X

CONDUIT AND AMPACITY INFORMATION MAXIMUM OF CONDUCTORS IN CONDUIT* TYPE RHW & RHH (without outer covering) THW CONDUCTOR SIZE AWG,MCM 0 8 CONDUIT TRADE SIZES (INCHES) 0 8 9 9 0 0 9 7 7 9 9 9 7 7 7 0 8 8 0 0 CONDUIT AND AMPACITY INFORMATION MISC. TW THW FEPB ( thru ), RHW and RHH (without outer covering) RH, THHW /0 /0 /0 /0 0 00 0 00 00 00 700 70 *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C. * ALLOWABLE AMPACITIES OF INSULATED COPPER & ALUMINUM CONDUCTORS (W IN CONDUIT) 7 C (7 F) A 8 0 8 /0 /0 /0 /0 0 00 0 00 00 00 700 70 *CU B 0 0 8 00 0 0 7 00 0 8 0 80 0 0 7 AL or Cu-Clad AL A 0 8 /0 /0 /0 /0 0 00 0 00 00 00 700 70 C 0 0 0 0 7 90 00 0 80 0 0 0 70 0 0 7 8 A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 0-) AMBIENT TEMP.C 8 7 0 9 7 CORRECTION FACTOR 0 8 7 8 0 9 8 7 AMPACITY CORRECTION FACTORS AMBIENT TEMP.F -.0 70-77 - 0.00 79-8 -.9 88-9 - 0.88 97-0 -.8 0 - - 0.7 - -.7 - - 0.8-0 -. - 8-70 0-7 Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 99 N.E.C. Manual article 0- and ANSI / UL- (except where restricted by line connector size). These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 7 C insulated wire conductor, sized in accordance with Table 0- of the National Electric Code. GANG SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS 00A / POS. AMPACITY 00A 00A 00A A 70A A / POS. AMPACITY 00A A 0A 8A 0A 0A / POS. AMPACITY 00A A 70A 8A 9A 00A / POS. AMPACITY 00A 70A 0A 0A 8A Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed amps for AWG, 0 amps for AWG, and 0 amps for 0 AWG copper: or amps for AWG and amps for 0 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. All meter sockets are 00 Volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted.

ENERGIZATION OF ELECTRICAL EQUIPMENT IMPORTANT NOTE In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. BEFORE ENERGIZING A. Give equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. ) Proper clearances have been maintained. ) All connections have been made. ) Equipment is clean and dry. B. Make a thorough examination to verify: ) Tightness of all bolted connections (see table below). ) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. ) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. WHEN ENERGIZING A. Use caution and follow established safety procedures: ) Wear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. ) Take action to prevent/decrease damage to property in the event of failure of the installation. ) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. MISC. ENERGIZATION OF ELECTRICAL EQUIPMENT RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* NOMINAL JOINT DESCRIPTION HEAD TYPE TORQUE SIZE SCREW NUT ( INCH LBS. ) 0 0 0 / / / BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL Brass Nut or Extruded Hole CU or AL Busbar </8 Steel Nut or EH; CU or AL Busbar >/8 Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole ALL ALL ALL ALL ALL ALL ALL HEX 0- in. lbs. -0 in. lbs 0- in. lbs 0- in. lbs 0-0 in. lbs. 0-0 in. lbs. 0-0 in. lbs. 0-70 in. lbs. / STEEL Steel Nut or EH; CU or AL Busbar HEX 00-0 in. lbs. /8 STEEL Steel Nut HEX 0-00 in. lbs. / STEEL Steel Nut HEX 00-0 in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum

MATERIALS AND FINISHES MATERIALS STEEL QUALITY The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. STEEL SHEET MATERIALS AND FINISHES MISC. FINISH gauge, galvanized, sheet: / oz./ sq.ft. class zinc-coated. (AISI G90) gauge, galvanized, sheet: / oz./ sq.ft. class zinc-coated. ALUMINUM EXTRUSION Wire-Terminals: Alloy; 0-T, Tin-plated for wire. Bus Bar: Alloy; 0-o & 0-O ALUMINUM SHEET 000 series aluminum sheet, H, or 0 series aluminum sheet, H. Where applicable thicknesses range from.0. COPPER SHEET & BUS Electrolytic copper with tin plating in most applications. INSULATING MATERIALS In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. RATING PROCESS Light gray state of the art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. METAL FASTENERS Zinc-coated with a chromate dip. NEMA RATING All Milbank meter sockets, CT cans and meter socket / breaker units have a Type R rating.

WATTHOUR METERS STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED 7 SC SC TR TR TR and -WIRE FORMS S & S and -WIRE FORMS S & S with BY -WIRE FORM S th Term. 9 o'clock -WIRE FORM S with BY -WIRE FORM S th Term. o'clock TR SC SC SC SC -WIRE FORM S with BY TR TR SC SC TR -WIRE FORM S TR TR SC SC TR ELEMENT W, W, W FORM S TR = TRANSFORMER RATED SC = SELF CONTAINED ELEMENT -WIRE NETWORK FORM S th TERM. 9 o'clock -WIRE FORM S WITH BY ELEMENT W, W, W FORM S with BY ELEMENT -WIRE NETWORK FORM S with BY th Term. 9 o'clock or ELEMENT W Y or Δ Y FORM S Δ FORM S ELEMENT -WIRE NETWORK FORM S th TERM. o'clock or ELEMENT W Y or Δ FORMS S & S with BY TR TR TR or ELEMENT W Y or Δ FORMS 8S & 9S with BY ELEMENT W, W, W FORM S ELEMENT W Y FORM S or ELEMENT W, W, W FORM S with BY ELEMENT W Y FORM S with BY ELEMENT -WIRE NETWORK FORM S with BY th Term. o'clock ELEMENT W Y or Δ Y FORM 7S Δ FORM S with BY or ELEMENT W Y or Δ Y FORM 9S Δ FORM 8S MISC. WATTHOUR METERS STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7

8 ADDITIONAL MILBANK PRODUCTS Other quality products available from Milbank ADDITIONAL MILBANK PRODUCTS MISC In addition to your local utility s meter mounting equipment, Milbank also manufactures supporting products, such as... Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches Contact your local distributor or go to www.milbankmfg.com to find additional product literature. 8

INDEX 9 CAT. NO. PG 00......................... TR........................ T8K........................ A7........................ A7........................ A7........................ A77........................ A78........................ A7........................ A80........................ A8........................ A8........................ A90........................ CP-........................ K07........................ K0....................., K0L....................... K9....................., K0....................., K0L....................... K....................., K8....................., K08........................ K08........................ K........................ K........................ K........................ K8........................ K09........................ K9........................ K9........................ K0........................ K08........................ K9........................ K00-0................... K00-0.................... K00-0GR.................. K00-BRIDGE-POS........... K00-BRIDGE-POS........... K00-TT0................... K........................ K800........................ KT......................., L7-XL-KK................... L7-XL-KK................... L7-XL-KK................... L7-XL-KK................... L7-XL-KK................... M-....................... CAT. NO. PG MR-......................... MR-8......................... NU8980-O-00-KK..............9 NU8980-O-00-KK-LP...........9 NU8980-O-00-KK..............9 NU8980-O-00-KK-LP...........9 S88........................ S9-TO..................... S7....................., S88........................ S8........................ S8988........................ U-X-KK................... U-X-KK................... U-X-KK................... U-X-KK................... U-X-KK................... U78-O-WI...................0 U779-RRL....................0 U980-O-KK....................8 U9-X-K7-INV................ U7-XT-PED................. U7-XT-PED................. U7-XT-PED................. U8-X-KK-K-PED............ U8-X-KK-K-PED............ U8-X-KK-PED............... U8-X-KK-PED............... U8-X-KK-PED............... U8-X-KK-K-PED............ U8-X-KK-K-PED............ U8-X-KK-PED............... U8-X-KK-PED............... U8-X-KK-PED............... U000-O-KL-KL..............0 U800......................... U80......................... U80......................... U8-0GR.................... U89-O-/00-INV.............0 U88-O....................... U88-O-0GB.................. U88-O-0GB.................. U-O-00S................. U-O-00S................. U-O-00S/............... U7-O-00S................. U7-O-00S................. U7-O-00S/............... CAT. NO. PG U70-RL-TG-KK................8 U700-RL-TG-KK................8 U77-RL-KK..................8 U787-RL-TG-KK................7 U707-RL-00-KK..............8 U8-O...................... U899-RL-TG-KK................8 U907-O......................7 U908-O......................7 U90-RL......................9 U9-O.......................9 U9700-RRL.....................9 U970-O.......................9 UQFB-00.....................7 UQFB-00-X..................7 UQFB-.....................7 UQFB--X..................7 UQFB-0.....................7 UQFB-0-X..................7 UQFB-7.....................7 UQFB-7-X..................7 UQFB-00.....................7 UQFB-00-X..................7 UQFBH-00...................7 UQFBH-...................7 UQFBH-0...................7 UQFBH-7...................7 UQFBH-00...................7 UQFP-00.....................7 UQFP-.....................7 UQFP-0.....................7 UQFP-7.....................7 UQFP-00.....................7 UQFPH-00...................7 UQFPH-...................7 UQFPH-0...................7 UQFPH-7...................7 UQFPH-00...................7 UQFPH-M-00.................7 UQFPH-M-.................7 UQFPH-M-0.................7 UQFPH-M-7.................7 UQFPH-M-00.................7 UQFP-M-00..................7 UQFP-M-..................7 UQFP-M-0..................7 UQFP-M-7..................7 UQFP-M-00..................7 INDEX 9

0 NOTES NOTES 0

NOTES NOTES

Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches REPRESENTATIVE Callas/Kingsley 8 Lively Boulevard Wood Dale, IL 09 Tel: 0-9-7887 Fax: 0-9-9 www.ckelectricalsales.com MILBANK MFG. CO. PO Box 908 Kansas City, MO -008 Tel: 8-8- Fax: 8-8-7 Toll Free: 877-8- www.milbankmfg.com www.milbankmfg.com NIPSCO /0 (K)