www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Similar documents
GENERAL. CONSTRUCTION External

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

EE 741 Over-voltage and Overcurrent. Spring 2014

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Kuhlman Electric Corporation Volt Instrument Transformers

K-Limiter high ampere Companion II fuse

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Solid Dielectric, Three Phase Reclosers CATALOG VS11

GROUP D. Switch & Protective device.

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Kuhlman Electric Corporation Volt Instrument Transformers

Technical Specification for Pole Mounted Capacitor Rack

Capacitor Related Definitions

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Solid Dielectric, Single Phase Recloser

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

A. Submit manufacturer's literature and technical data before starting work.

Publication No.: PSG

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Volt Instrument Transformers

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

15 kv and 25 kv Thru-Bushings

Product Specifications for Aluminum Vertical Break Switches

Eaton s Cooper Power Systems

Each of these factors, as they apply to the selection of Types CLE and CLS current limiting fuses, is briefly outlined on the following pages.

SafeGear TM Motor Control Center Arc resistant metal-clad construction

25 kv Apparatus Bushings

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Cobra-S. Catalog Cobra-S

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

Overview Overvoltage protection

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

MGL Avionics AvioGuard. Fault protected, wide input range, isolated, DC to DC converter for avionics applications

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Chapter 6 Generator-Voltage System

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

SWITCHGEAR DIVISION PRODUCT PROFILES

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Fuse Link Designation

Horizontal Circuit Switchers

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

Wind Power Solutions. Make Energy Renewable and Reliable!

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

Technical Specification For Outdoor Substation Harmonic Filter Banks

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Medium Voltage Metal-Enclosed Switches

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Polymer Insulator. ITEM 15kV 25kV 35kV 69kV. Section length(l) 330±15mm 445mm 539mm 888mm. Min. arcing distance 215mm 300mm 340mm 701

X-Limiter full-range current-limiting fuse

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

High Voltage Surge Arresters Station Class

Oil Circuit Breakers

3.2. Current Limiting Fuses. Contents

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

4.0 OPERATION Type ITH-T Relay

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Medium Voltage Metal-Enclosed Switches

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Pretest Module 29 High Voltage Unit 1

Horizontal Circuit Switchers

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

MEDIUM VOLTAGE NETWORKS

600 A 15 and 25 kv class Cleer grounding elbow

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below

Transcription:

December, 1975 New nformation and Supersedes DB 38-131 Pages 1-4, dated May 1972, and 38-121 D WE A, Pages 1-4, dated April1974 E, D, C/1981/ DB Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, ndiana 47401 ndoor-outdoor Altitude 0-10,000 feet 3-468 KV 38-141 DWEA Page 1 CPL Station Arrester Controlled Protective Level

Page 2 CPL Means Protection The CPL arrester is designed as a protective device. ts primary purpose is to protect the system insulation from damaging overvoltage surges. The secondary protective function of the CPL arrester is to protect itself from the surge currents it must discharge. The quality components and design of the CPL Station Class Arrester allow it to perform both of these functions. Matched Components Protect a Modern System Utilizing matched components and expert design, the new generation of Westinghouse CPL Station Class Arresters have low protective characteristics for standard ratings 3 KV through 468 KV. Volṭage control of all sparkover and discharge voltages guarantees Controlled Protective Levels to safeguard electrical insulation from lightning and switching surge transients while at the same time assuring that the switching surge discharge voltage does not exceed the switching surge sparkover voltage. Also the characteristics of the CPL Arrester make it suitable for protecting rotating machines and dry type insulation. Controlled Protective Levels make significant savings possible by reduction in transformer basic impulse insulation levels up to 3 steps reduced for systems with an effectively shielded substation and a low coefficient of grounding. The Major Matched Components of the CPL Station Arrester are: o Control Gap o nterrupter Gap o Grading Components o Valve Elements Control Gap The high voltage CPL Arrester (60-468 KV) has parallel path gaps which separate the voltage sensing and current interruption functions of an arrester's gaps. This technology results in a level of arrester sparkover and reliability formerly unattainable with conventional arresters. Conventional arresters have gaps which perform the dual role of voltage sensing and current interruption while the high voltage CPL uses a separate control gap and interrupter gaps. The control gap serves as the voltage sensing, measuring, and triggering device and is located out of the power interruption path. t is connected in parallel with an interrupter gap and is not involved in the energy dissipating and current extinguishing duty. The interrupter gap serves as the energy dissipation and power follow current interruption device. The control gap is the key element in controlling switching surge sparkover. The parallel path circuit of the high voltage CPL assures that the control gap will retain its precise sparkover characteristics. The control gap is made with planar electrodes hermetically sealed to the ends of an alumim ceramic tube and filled with a tritium preionizing agent. The large electrodes produce a uniform electric field that is not polarity sensitive. The electrode to ceramic hermetic seal assures a precision control gap for the life of the arrester. The low voltage CPL Arrester (3-48 KV) uses conventional gap circuitry with the interrupter gap preforming both the voltage sensing and current extinguishing duties. Control Gap nterrupter Gap Assemblies The current-limiting interrupter gap coordinates with the valve element to assure that the total arrester voltage does not exceed the maximum switching surge sparkover voltage even when producing back voltage to reduce the amount of energy that the arrester is required to absorb. The interrupter gap assembly consists of permeable ceramic gap plates that cool and assist in the interruption of the arc which is extended between horn shaped copper electrodes. The interrupter gap assembly also includes ceramic slab preionizers to insure consistent sparkover levels. The self-bonded magnetic drive coil stretches the arc between the ceramic gap plates, and the interruption of the power follow current is accomplished within a fraction of a half cycle. nter-rupter Gap Assembly High Voltage CPl (60-468 KV) nterrupter Gap Assembly low Voltage CPl (3-48 KV) The interrupter gap assembly for the low voltage CPL includes grading resistors as well as gap sections and a magnetic blowout coil. n the high voltage CPL the interrupter gap assembly includes only the gap sections and magnetic blowout coil.

Grading Capacitor High Voltage CPL Grading Resistor High Voltage CPL Grading Resistor Low Voltage CPL 38-141 D WE A Page 3 Grading Components The voltage distribution of the CPL is precisely controlled by the frequency and voltage responsive grading elen,ents. The non-linear grading resistors are made of high quality silicon carbide and the grading capacitors are solid ceramic body fixed capacitors. The high voltage CPL utilizes resistors and capacitors in its grading scheme. The low voltage CPL uses nonlinear resistor grading only. Valve Elements The non-linear resistance elements (blocks) are made of high quality silicon carbide which is a semi-conductor exhibiting a non-linear voltage-current relationship. The resistance elements are ceramic bonded with a special composition to obtain low discharge voltages and high thermal capability. Valve Element

Page 4 The Total Picture ----; 1 Grading Resistor Schematic High Voltage CPL Schematic Low Voltage CPL Grading CaL:_j_ Valve Element,-----1 nterrupter : Gap Valve Element ---,--" "- Magnetic Blowout Coil ---'---..- 1 nterrupter 1 Gap Assembly.1 Grading Resistor Assembly L- : r---- l_.: L--- -----, j r---------.., -------, lr---- C j l_tf- High Voltage CPL (60-468 KV) Physical Construction Low Voltage CPL (3-48 KV) Physical Construction

8 Critically-Tested Construction Protects The CPL Arrester Special attention is given to the following major construction components of the CPL Station Arrester: Sealing System nternal Suspension System Porcelain Housing Fault Withstand Capability Sealing System The CPL arrester is the only station arrester with double sealing; a primary sealing gasket and the backup protection of a weather seal gasket. The end plates are sealed to the arrester porcelain with a neoprene gasket confined in restraining channels and held under pressure to maintain the effectiveness of the seal. To protect the primary sealing gasket from the effects of the environment a weather seal of asbestos neoprene is used. This seal is actually the front line defense against potentially damaging effects of the atmosphere on the arrester's primary sealing gasket. Spring Suspension Low Voltage CPL Sealing System High Voltage CPL 38-141 D WE A Page 5 Sealing System Low Voltage CPL nternal Suspension Systems The high voltage CPL uses a leaf spring suspension on the vertical axis of the arrester internal assembly to absorb shocks and vibrations caused by shipping and handling. The internal arrester structure is protected from side thrust by side wall supports positioned at every 5" of the arrester's height to absorb shocks. The vertical axis of the low voltage CPL internal assembly is supported by coil springs. Side wall supports for side thrust protection are positioned between every block and gap assembly. Side Wall Supports High Voltage CPL Side Wall Supports Low Voltage CPL

Page 6 High Strength Wet Process Porcelain All CPL arresters are constructed using high strength wet process porcelain. The porcelain of the CPL arrester passes all insulation withstand tests per AN Sl C62.1. The coordination of the porcelain height and high standard creep distance with the internal grading scheme of the arrester provides excellent contamination resistance, insuring that the arrester passes the contamination test cycle of AN Sl C62.1. CPL Porcelain Cantilever Strength Voltage 3-48 Kv 60-312 Kv 396-468 Kv l_ t. lbs. i 5800 1 17000 25000 Pressure Relief Capabilities CPL arresters have been sucessfully tested in accordance with the pressure relief test requirements of ANS C62.1. CPL's have published "safe fault current" pressure relief capabilities in excess of standards as shown in the table below. Arrester Rating(j) (KV) 15 65000 66000 21-48@ 40000 44000 60-192 40000 63000 240-294@ 25000 63000 300-312 396-468 Not Given Not Given 63000 63000 3 - ANS C62.1 Class High Current Test (RMS Symmetrical Amperes) CPL (RMS Symmetrical Amperes) CD Pressure relief ratings for porcelain top arresters are not standardized. @ 18 KV arrester included with these ratings. @ ncludes 204, 216, and 228 CPL arresters 3-312 KV have exhaust ports that provide directional venting in the remote event of a pressure relief operation. Directing the hot ionized gases away from the protected equipment minimizes the possibility of flashover of close-by arresters, bushings, or bus supports. CPL arresters 396-468 KV do not have directional venting. Typical Porcelain High Voltage CPL Exhaust Port High Voltage CPL (60-312 Kv) Typical Porcelain Low Voltage CPL Exhaust Port Low Voltage CPL (J-48 Kv)

Built in Quality Verified Through Production Testing CPL arresters are tested at each of the various stages of manufacturing to insure that the final product offers continued protection for the modern system. Seal Test Valve Element Test nterrupter Gap Test Grading Component Test Control Gap Test Final Unit Test Seal Tests The CPL sealing system is leak tested after the arrester is completely sealed and ready for shipment. Each arrester unit is evacuated and back filled with dry nitrogen and trace quantities of helium. The filling tube is then pinched off (cold weld) completing the seal of the arrester unit. The arrester unit is then placed in a vacuum chamber which is evacuated. As gas is evacuated, it is passed through lines to sensitive helium detection equipment capable of recording a leak rate as small as 5 x 1013 atmosphere-cc/ second. The Leak Detection System Tests the Complete Arrester-End Plates, Seals, Castings, and Porcelain- Unlike Other Arrester Testing Methods That Require the Gas Fill Hole To Be Plugged After the Seal Test s Completed. The CPL s Completely Sealed Prior To Seal Testing -Not Afterwards. Seal Testing Of a High Voltage CPL Arrester Valve Element Testing Valve elements are seasoned then tested for discharge voltage and thermal capability. nterrupter Gap Tests Each gap is placed in a test cell which is evacuated and then filled with arrester atmosphere. The gap must then sucessfully pass three electrical performance tests: 60Hz Radio influence test Repetitive sparkover tests Performance Testing To verify that CPL arresters provide low and consistent protective characteristics, each unit is tested for the following electrical values: High Voltage CPL (60-468 KV) Radio influence voltage. Grading current at 60 Hz rated voltage 60 Hz sparkover Switching surge sparkover 38-141 D WE A Page 7 Grading Components Testing High accuracy equipment is used to test each ceramic capacitor and non-linear resistor. The tests are made in a controlled atmosphere environment. Control Gap Testing Each control gap is subject to ten sparkover applications of each polarity of a ramp voltage and then categorized for use with other arrester components. Control gaps are energized above rating and given a radio influence voltage test. Low Voltage CPL (3-48 KV) Radio influence voltage Grading current at 60 Hz rated voltage 60 Hz sparkover

38-141 D WE A Page 8 Further nformation 38-140 P WE A 38-146 TWEA 38-142 F WE A Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, ndiana 47401