Generator/Loadbank Quick Connection Tap Box

Similar documents
Generator Quick Connection Tap Box WM Series

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

A. Submit manufacturer's literature and technical data before starting work.

Generator/Loadbank Quick Connection Switchboard

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

SWITCHGEAR DIVISION PRODUCT PROFILES

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Low Voltage Automatic Transfer Switch Systems

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

ASCO Low Voltage Automatic Transfer Switch Systems

Critical Power Switchboards. Selection and Application Guide

SECTION PANELBOARDS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Power Break II Switchboard

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Transfer switch OTEC and OTECSE open transition

C1000 Series Automatic Cap Bank

University of Houston Master Construction Specifications Insert Project Name

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Service Entrance Methods

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

OTEC Transfer switch open transition

Optimizing Emergency Power Systems for Health Care Applications

Tradition. Technology. Innovation.

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Medium Voltage Metal-Enclosed Switches

Caterpillar 1500kW XQ1500

Medium Voltage Metal-Enclosed Switches

Quik-Spec Electrical Gear

Switchgear Skid, C1192

Introduction. Features. Intelligent Technologies Motor Control Center Structures

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Scope of Supply / Major Bill of Materials

Generator Fire Safety: Generator assemblies should be located outside the building.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

BUSWAY Low Voltage (Pow-R-Flex)

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

Posi-Lok Plugs and Panels

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

AT30 SERIES BATTERY CHARGER

30 Years of Innovative Solutions for Construction & Industry

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

INSTALLATION INSTRUCTIONS

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

7. SERVICES OVER 600 VOLTS

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Transfer switch OTEC open or delayed transition

MP7650 CONTROLLER. Lake-Shore-Electric.com MP7650 Controller STANDARD FEATURES 1.0 INTRODUCTION

IN2 Enclosed Switches and Circuit Breakers

HIGH POWER RECTIFIER SYSTEMS

6.2. Power Pedestals. Contents

Three-Phase Pole Mounted Recloser

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Quick Connection Cabinet (QCC)

AT10.1 SERIES FLOAT BATTERY CHARGERS. Advanced technology microprocessor control

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

GE 8000-Line Motor Control Centers

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Cam-Lok Single Pole Connectors

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Energy Security Electrical Islanding Approach and Assessment Tools. Dr. Bill Kramer Senior Research Engineer Distributed Energy Systems Integration

Midwest Dry Type Transformers

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Pika Energy Island Made in America

SECTION MOTOR CONTROL

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

5.2. Power Pedestals. Contents Description

Bussmann series Quik-Spec Coordination Panelboard

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

Busway Construction. Bus Bars

Microgrid solutions Delivering resilient power anywhere at any time

Horizontal Circuit Switchers

Basics of Paralleling

Transcription:

/ Generator/Loadbank Quick Connection Tap Box WM2-Series Generator/Loadbank Quick Connection Solutions Brochure www.apt-power.com 433 N. 36 th Street Lafayette, IN 47905 (765) 446-2343 ALN: 517 Rev. 01

Standard Construction Enhance Safety Figure 1: Mechanical lugs on silver plated copper bus bars (Top) with Cam-lok Cover (Left) and Male Cam-lok Receptacle (Right) Figure 2: Loadbank Quick Connection Tap Box Inside Access Carbon Steel NEMA 3R 400A-4000A Generator or Loadbank Quick Connection Tap Box UL Listed Wall Mount System Ratings: o Voltage: 208V-480V (3Ø, 4W) o Current: 400A-4000A o Interrupting Rating: 10-65 kaic Silver-plated copper phase bus bar for permanent connection to the facility Easy and spacious access to color coded, generator (male) & loadbank (female) E1016 cam-lok type receptacles with covers o A phase Brown (480V) / Black (208V) o B phase Orange (480V) / Red (208V) o C phase Yellow (480V) / Blue (208V) o Neutral White o Ground Green APT Mechanical Lugs for incoming utility & permanent facility-side connections on NEMA standard hole patter Standard Enclosure: o Pad-lockable hinged main access door o Integral lower flip door (allows the main door to be closed with the mobile generator cables connected) o Bottom door mechanically interlocked with front door to prevent unauthorized access to receptacles when not in use o Powder coated ANSI 61 Gray o NEMA 1/3R for indoor applications o Permanent Connections: Side/Rear, Exit o Temporary Connections: Bottom Flip Door Entry Tenchi90-2 - ALN: 517 Rev. 01

Tap Box Features Circuit Breaker Cam-lok Style Receptacles Lower Flip Door (Kirk Key Interlocked with Circuit Breaker) Figure 3: 600A Quick Connection with Auxiliary Circuit Breaker Figure 4: 800A Service Entrance Manual Transfer Tap Box Monitoring, Interlocking, & Protection Phase Rotation Monitoring: o Provides visual assurance that mobile generator set phase rotation matches that of the facility o Configured to prevent circuit breaker from being closed if phase rotation is incorrect o Instructions to easily fix incorrect phase rotation are on a label inside each panel Ground Fault Monitoring: o Trips the circuit breaker on ground fault or provides alarm indication only o Configured at the factory per your order o Easily re-configurable in the field NEC 700.3 compliant temporary generator source connected indication Interlocking: o NEC 700.3 compliant key interlocking to prevent inadvertent paralleling of the temporary generator source with normal source(s) Shunt Trip: o 120VAC for tripping circuit breaker if phase rotation is incorrect or on ground fault sensing Temporary Generator Protection o Molded Case Circuit Breakers o Fixed mount o Trip Unit Thermal Magnetic Electronic trip unit with adjustable Long Time, Short Time, Instantaneous settings o Aux Contacts ( a & b ) o Standard or 100% rated - 3 - ALN: 517 Rev. 01

GQC Tap Box Options Figure 5: 800A Interlocked Utility Service Disconnect Figure 6: 800A Temporary Generator Quick Connection with Generator Signal Terminal Blocks for Customer Connections in Type 304 Stainless Steel Enclosure Pad Mounting, Enclosure Options, Optional Features Termination Cabinet (Lug Inputs/Outputs Only) Load Transfer means: o Open Transition Manual Transfer via mechanical key interlocking Hurricane Resistant Wall-Mount to Pad- Mount Conversion Kit o 3/16 Formed Steel Construction o Bolt together design for easy factory or field assembly o Designed to withstand Category 5 Hurricane force winds Up to 190MPH o Galvanized or Powder Coated Finish Enclosure options: o NEMA 4X for outdoor installation: Type 304 or 316 Stainless Steel Other Options o No Neutral Bus or Cam-loks o 100% Ground o Surge Protection Device (SPD) o Generator Remote Start/Stop Terminal Blocks o Generator Block Heater Receptacle o 480VAC or 240VAC Twist-lock Receptacle o 120VAC Battery Charger/Convenience Receptacle o Load Dump Receptacle/Terminal o Extra Large Enclosure for Conduit Entry/Exit o Custom Color o Convenience Light o SCADA Connection Interface - 4 - ALN: 517 Rev. 01

Key Interlocking Configurations Figure 7: 800A Interlocked Utility Service Disconnect Figure 8: 800A Temporary Generator Connection Receptacles Accessed via Key Interlock with Utility Circuit Breaker Utility, Generator Only, Loadbank Only, Applications Generator connection only applications typically require Kirk Key Interlocking to safely prevent the inadvertent paralleling of the normal & emergency power sources: o Service Entrance Rated Manual Transfer Tap Box (two integrated Kirk Keys) Utility Service Entrance Circuit Breaker with Kirk Key Temporary Generator Circuit Breaker with Kirk Key o Temporary Generator Connection Only External service main no temporary generator circuit breaker protection One integrated Kirk Key, one ship loose Kirk Key for installation on facility service main o Multiple generators or feeders circuit breaker sections (multiple Kirk Keys, transfer block) Operation sequence without the interlocking of sources is available upon request for users with advanced knowledge of their facility s requirements and procedures Loadbank connection only applications o Easily connects a temporary Loadbank to a facility s permanent generator(s) o Utilizes female cam-lok type receptacles o Does not require the use of interlocking o Circuit breaker and monitoring options available - 5 - ALN: 517 Rev. 01

GQC Tap Box Wall Mounted - 6 - ALN: 517 Rev. 01

GQC Tap Box Pad-Mount Kit - 7 - ALN: 517 Rev. 01

APT Product Part Number Builder *Customer to provide description of the features desired - 8 - ALN: 517 Rev. 01

Typical Applications for GQC & LQC Generator Only Configurations Figure 9: Single Circuit Breaker Option Figure 10: Dual Circuit Breaker Option with Utility & Gen Breaker Figure 11: Multiple Circuit Breakers Option Figure 12: Feeder Circuit Breakers Option Figure 13: Two Self Sync Temp Gensets into two sets of Cam-loks Figure 14: Two Self Sync Temp Gensets into one set of Cam-loks Figure 15: GQC integrated into Low Voltage Switchgear Loadbank Only Configurations Figure 16: LQC Single Circuit Breaker Option Figure 17: LQC integrated into Low Voltage Switchgear for annual Genset Testing - 9 - ALN: 517 Rev. 01

About Advanced Power Technologies Advanced Power Technologies (APT) is on the cutting edge of the latest engineered power system smart technologies, as it relates to microgrid & storage management, renewable & conventional energy source deployment, demand peak shaving, and facility back-up and co-generation power systems. Located in the central United States and headquartered in Lafayette, Indiana with solutions development engineers around the country, APT provides domestic and international products and services to industry leading companies from around the world. APT engineers have decades of power system experience from working with some of the largest companies in industry. Over the last two decades, we have produced successful solutions for hundreds of large-scale electric power projects involving utility/generator paralleling, transfer, peak shaving, and distribution. We pride ourselves in providing electrical power systems that are engineered and custom built, utilizing state-ofthe-art technologies to fit our customer s exact needs. The core of our business is low & medium voltage engineered power systems for a wide range of indoor & outdoor applications, such as: Utility(ies) and Generator(s) Paralleling/Transfer/Peak Shaving/Distribution Switchgear Microgrids, Microgrid Master Control Panels, SCADA systems Containerized Battery Energy Storage Systems (BESS) Photovoltaic (PV) Solar Power Collection/Distribution & Renewable Energy Storage Systems Low & High Resistance Grounding Systems, Grounding Systems for Photovoltaic Effective Grounding High Efficiency Combined Heat and Power Switchgear & Control Systems (CHP, Co-generation) Outdoor Walk-In Electrical Houses (E-Houses) & Skid-Mounted Switchgear Motor Control Centers & Motor Control Switchgear Automatic & Manual Load Transfer Switchgear Bypass/Isolation & Power Distribution Circuit Breaker Switchboards Generator/Loadbank Quick Connection Switchgear, Switchboards, & Tap Boxes Industrial Control Panels Please see our product webpages on www.apt-power.com for product brochures and relevant information. Actual products may look different from images shown on the website and in brochures, based on actual specifications. APT cares and understands that each power system is different. We will evaluate various solutions in order to develop the best solution for a site. APT focuses on our ability to a combine several traditional pieces of equipment/functionality into as little of a footprint possible. This saves on space, the cost of equipment, cost of installation, and accomplishes the most optimal/state-of-the-art design your facilities. APT's desires to foster and grow a culture of continued open communication with each customer. Let APT be your source to provide fully engineered power system equipment solutions for the full customer facility on time, on or under budget, and in the smallest footprint possible. We are always available to assist customers and engineers representing customers in the development of complex power solutions for all facility types. - 10 - ALN: 517 Rev. 01