Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Similar documents
Application for Energy and Fuels

Application for Energy and Fuels

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

Prodigy ICP Application Note: # 1039

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

Chemical and Petrochemical Applications of Microwave Plasma Atomic Emission Spectroscopy (MP-AES)

X-ray Analysis in Petrochemical and Polymer Industries: Challenges and Solutions

lubricants analysis. complete solutions for your lab. Lubricants Analysis

Elemental Analysis Advanced

224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE

S-PRO 3200 GC System for Sulfur Analysis

AVIO 200/500 ICP-OES CONSUMABLES AND SUPPLIES. Consumables and Supplies Reference Guide

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards

The Analysis of Biodiesel for Trace Metals and the Development of Certified Biodiesel Standards

Monitor Chlorine in Crude at Sub-ppm Levels

X-ray Essentials from XOS Proven Performance

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards

Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers

WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony. October 31,

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

CALIBRATION AND VERIFICATION STANDARDS. The benchmark for accurate measurements. Cerium Standards Sulfur-in-Oil Standards Viscosity Standards NEW

4 A village survey: Mandari, Lakshmipur

Certificate of Accreditation

TSHR 6000 series TN/TS/TX analyzer

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Calibration & Verification Standards

Certificate of Accreditation

CALIBRATION AND VERIFICATION STANDARDS

CALIBRATION AND VERIFICATION STANDARDS

INTERPRETATION OF USED COOLANT ANALYSIS

The Role of Chemical Metrology in Transportation Industry

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.

Petrochemical standards

GLASS EXPANSION NEWSLETTER

Where oxygenates are used, ethers are preferred. Methanol is not permitted. (5)

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Analysis of Sulfur and Trace Element Content in FAME

Conversion Processes 1. THERMAL PROCESSES 2. CATALYTIC PROCESSES

breakthrough versatility

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

CHEMICAL CHARACTERIZATION OF PARTICULATE MATTER EMISSIONS FROM A CATALYZED TRAP EQUIPPED NATURAL GAS FUELED TRANSIT BUS

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Shell IMAA Workshop Making Sense of Oil Analysis

The Importance of Biodiesel Meeting the ASTM D6751 Standard. Barbara E Goodrich Manager, Engine Fluids John Deere Power Systems 6 February 2008

is a division of SCP SCIENCE Calibration and verification standards version 10.0 The benchmark for accurate measurements

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

UL ALTERNATIVE FUELS & STANDARDS UPDATE

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Metals Determination in Biodiesel (B100) by ICP-OES with Microwave Assisted Acid Digestion

Conversion of Peanut Oil into Jet and Diesel Fuels. Panama City, Florida 22 July 2016 Edward N. Coppola

Antek Gas Chromatography Products: A Guided Tour Through Industry

Internal Combustion Engines

Thermal Exploitation of Wastes in Lignite Combustion Facilities

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Emissions Characterization of Three High Efficiency Wood Boilers

3/15/2017. Oil Analysis: When the Oil Speaks, You Should Listen! Oil Analysis. Common Wear Metals Found in Oil. Common Wear Metals Found in Oil

Distillation process of Crude oil

MINIMIZE WORKFLOW INTERRUPTIONS

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

SERVICE. Condition Monitoring Service Oil Check Condition Monitoring. Lubricant analysis Schwingungsanalyse Vibration SmartCheck

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

ASTM D7039. Sulfur analysis plus a further 21 elements by MWDXRF. Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF

Conversion of Carinata Oil into Drop-in Fuels & Chemicals. Carinata Summit Quincy, Florida 15 March 2016

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For

Quantitative Analysis of Chemical Compositions from Various Sources of Crude Glycerine

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

Cetane ID 510. Customer Presentation. Refining. Petrochemical

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

TSHR 7000 series TN-TS-TX analyzer

Application Note. Abstract. Authors. Environmental Analysis

Oil & Gas. From exploration to distribution. Week 3 V19 Refining Processes (Part 1) Jean-Luc Monsavoir. W3V19 - Refining Processes1 p.

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Supply of Services for Detailed OEB Crude Assay Analysis

Characterization of crude:

The benchmark for accurate measurements SCP SCIENCE. Calibration and erification standards. version is a division of

Beverage Grade Carbon Dioxide

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

better analysis counts

Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City

New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared

C2, C3, C4 Monomer Analysis

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Biodiesel Fuel Quality

ISO 8754 INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Energy-dispersive X-ray fluorescence spectrometry

PORLA Heavy and Crude Oil Stability and Compatibility Analyzer as a Tool to Improve Profitability of Oil Industry

Refinery and Petrochemicals technology innovations are aimed to

Refinery and Natural Gas Analysis

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Low cost EDXRF elemental analyzer

D 5966 Roller Follower Wear Test. Final Report Cover Sheet. Report Packet Version No. Conducted For:

SCOPE OF ACCREDITATION

FREQUENTLY ASKED QUESTIONS WHAT IS ENGEN DYNAMIC DIESEL 50 PPM?

Transcription:

Advanced Petrochemical Applications With ICP-OES Tina Harville, Ph.D. Application Engineer

Elemental Analysis of Petrochem-Based Solutions Refineries and Petrochemicals Sulfur content of gasoline Acceptance testing of imported fuels Biodiesel analysis (ASTM D6751) Wear metals in oil Oil additive analysis (process control and trend) Metals in Catalyst & Catalyst Oil Metals in Process Solutions Metals in Drilling Fluids Other: Metals in Brines Etc!

ICP-OES Design and Performance for Petrochem Unmatched Background Correction Techniques Automatic (Polynomial Fitted Technique) FACT (Fast Automated Curve-Fitting Technique) Offpeak BC Left & Right Together Continuous Wavelength Coverage Robust RF & Plasma 33,000 wavelengths ready at all times Freedom from interferences MultiCal Robust, fast, frequencymatching 40MHz RF generator

Application Considerations The challenge: High vapour pressure from solvents Plasma instability Extinguished plasma Carbon build up in injector Poor precision and drift Down time - injector requires regular cleaning Nebulizer blockage Poor precision Down time - nebulizer needs cleaning

Application Considerations The solution: Plasma stability High Efficiency RF Generator Reduce solvent loading Double-pass spray chamber Plasma torch with 1.4mm ID injector Smaller id. peristaltic pump tubing Reduce pump speed Higher plasma power and plasma gas flows

Spray Chambers Double-pass glass cyclonic spray chamber Double pass design Reduces solvent load Increased sensitivity Fast washout Suitable for low vapour organic solvents e.g. Kerosene, ShellSol

Nebulizers Sample particulates may block standard concentric nebulizers Dependent on sample composition e.g. wear metal particulates Poor precision Down time - nebulizer needs cleaning Quartz nebulizer Conikal, Seaspray and Slurry Faster washout V-groove nebulizer Made of PEEK polymer Minimizes particulate blockage OneNeb Nebulizer Quartz nebulizer V-groove nebulizer OneNeb nebulizer Page 15

Compatibility of Pump Tubing Pump Tubing Solvent PVC Viton PVC Solva Kerosene Gasoline Fuel Coolant N/A = unsatisfactory, = satisfactory, N/A = no data available Page 11

Typical Instrument Conditions Plasma power Plasma gas flow Auxiliary gas flow Nebulizer gas flow (axial) Nebulizer gas flow (radial) 1.3-1.5kW 15 18 L/min 0.75 2.25 L/min (axial radial) Optimize (0.5 0.8 L/min) Set bullet to top of torch (0.5 0.8 L/min) AGM-1 setting 2-6 Stabilization delay Pump speed Uptake Rate Fast Pump Optimize via timescan 5 10 rpm < 1 ml/min Yes or No? Page 12

Elemental Analysis of Diesel Fuel by ICP-OES 1.2 1 0.8 0.6 0.4 0.2 0 Ag 328.068 Al 396.152 B 249.772 Ba 455.403 Ca 396.847 Cd 214.439 Cr 267.716 Cu 327.395 Fe 238.204 Mg 279.553 Mn 257.610 Mo 202.032 Ni 231.604 P 213.618 Pb 220.353 S 180 669 18:56:39 19:10:51 19:25:04 19:39:17 19:53:28 20:07:42 20:21:56 20:36:09 20:50:23 21:04:37 21:18:52 21:33:05 21:47:20 22:01:34 22:15:50 22:30:05 22:44:20 22:58:36 Page 13

Elemental Analysis of Diesel Fuel by ICP-OES Element/Wavelength DL (ppb) (nm) Ag 328.068 5 Al 396.152 20 B 249.772 9 Ba 455.403 0.8 Ca 396.847 0.5 Cd 214.439 4 Cr 267.716 7 Cu 327.395 7 Fe 238.204 5 Mg 279.553 1 Element/Wavelength DL (ppb) (nm) Mn 257.610 1 Mo 202.032 10 Na 589.592 6 Ni 231.604 18 P 213.618 60 Si 251.611 39 Ti 336.122 2 V 392.401 9.6 Zn 213.857 4.7 Page 14

Stability of Kerosene by ICP-OES Concentration (ppm) 10 9 8 7 6 5 4 3 2 1 8 Hour Stability Run - NO Int. Std. Worksheet S21Stab7.vws 0 0:00 1:12 2:24 3:36 4:48 6:00 7:12 Time (Hrs:Min) Ag 328.068 Al 396.152 Ba 455.403 Ca 396.847 Cd 214.439 Cr 267.716 Cu 327.395 Fe 238.204 Mg 279.553 Mn 257.610 Mo 202.032 Na 588.995 Na 589.592 Ni 231.604 P 213.618 Pb 220.353 Si 251.611 Sn 189.927 Ti 336.122 V 292.401 Zn 213.857 90 % Limit 110 % Limit Page 15

Stability Coolant Analysis 6 5 4 3 2 1 B 249.772 Ca 396.847 Co 238.892 Mg 279.553 Na 589.592 Ni 231.604 Si 251.611 0 1 18 35 52 69 86 103 120 137 Page 51

Plasma Stability of Naphtha 7 Concentration 6.5 6 5.5 5 4.5 4 3.5 Ni 231.604 Ni 216.555 Mg 279.553 V 309.310 V 292.401 Mg 280.270 Al 396.152 Ca 396.847 Ca 422.673 Cd 214.439 Cd 226.502 Cd 228.802 Cr 267.716 Cu 324.754 Cu 327.395 Fe 238.204 Fe 259.940 Mn 257.610 Na 588.995 Na 589.592 3 1 : 1 1 : 2 1 : 3 1 : 4 1 : 5 1 : 6 1 : 7 1 : 8 1 : 9 1 : 10 1 : 11 1 : 12 1 : 13 1 : 14 1 : 15 1 : 16 1 : 17 1 : 18 1 : 19 1 : 20 No. Samples Measured Short term stability over 30 mins. for Naphtha Page 17

Organic Applications Other challenges: Wear metals and additive analysis Require large linear dynamic range Structured backgrounds Molecular band observed at wavelengths > 330nm Speed of analysis Throughput = time = money Page 19

Speed of Analysis World s Most Innovative Detector Simultaneous ICP using custom designed and patented CCD detector Full wavelength coverage 167 785 nm Use alternate wavelengths to extended dynamic range and confirm results True simultaneous measurement Improved resolution Pixels arranged to exactly match 2 dimensional echelle image Duplex readout circuitry halves readout time Processing electronics off-chip for high QE 40 times faster due to 1 MHz processing speed Typical analysis times Can measure 1 sample in < 1 min. (all elements) Page 20

Page 21 Performance Test Linear Range Radial, S21 Conostan Oil Standards in Kerosene

Page 23 Biodiesel

Analytical Requirement for Biodiesel ASTM requires the analysis of Biodiesel Must satisfy all the requirements of ASTM D 6751-07be1, including: Sulphur and phosphorus (D6751) Total calcium and magnesium (D6751-07a) Total sodium and potassium (D6751-07a) Includes other properties such as: Flash point Water and sediment Free glycerin Page 24

Analytical Results ASTM Specified Elements in Biodiesel Element P S Na K Ca Mg Wavelength (nm) 213.618 181.972 589.592 766.491 393.366 279.553 B 100a ppm < IDL 1.695 0.162 0.507 0.013 0.011 B 100b ppm < IDL 1.710 0.130 0.469 0.012 0.012 B 100+1.0 ppm (%R) 105 103 104 107 105 104 B 100+2.5 ppm (%R) 102 106 102 104 103 101 IDL (ppb) 19.9 76.5 4.1 21.8 0.1 0.1 Bkgd Correction Fitted Fitted FACT FACT Fitted Fitted Page 27

Analytical Results Other Elements in Biodiesel Element Al Ba Cd Cr Fe Mn Mo Ni Wavelength (nm) 308.215 233.527 226.502 267.716 259.940 259.372 202.032 216.555 B-100a ppm < IDL < IDL < IDL < IDL 0.032 < IDL < IDL < IDL B-100b ppm < IDL < IDL < IDL < IDL 0.037 < IDL < IDL < IDL B-100+1.0 ppm (%R) 102 105 103 103 104 103 103 104 B-100+2.5 ppm (%R) 103 103 101 102 103 102 103 102 IDL (ppb) 5.4 1.0 0.6 1.6 1.0 0.3 5.7 6.9 Bkgd Correction Fitted Fitted Fitted Fitted Fitted Fitted Fitted Fitted Element Pb Sc Si Sn Ti V Zn Wavelength (nm) 220.353 361.383 288.158 283.998 334.941 309.310 213.857 B-100a ppm < IDL < IDL 0.141 < IDL < IDL < IDL 0.024 B-100b ppm < IDL < IDL 0.139 < IDL < IDL < IDL 0.024 B-100+1.0 ppm (%R) 102 104 104 102 104 105 104 B-100+2.5 ppm (%R) 101 103 103 104 102 104 102 IDL (ppb) 25.2 0.1 4.7 11.7 0.1 0.6 1.1 Bkgd Correction Fitted Fitted Fitted Fitted Fitted Fitted Fitted Page 28

Page 30 Naphtha

Why Determine Trace Elements in Naphtha? Growing need to determine trace metals in hydrocarbon samples The presence of trace metals can: Severely hamper the catalytic reforming process Poison the catalysts used e.g. S and N compounds can deactivate catalysts Catalysts used in catalytic cracking or reforming Photo courtesy Phillips Petroleum Company Page 55

Improved Sample Introduction Systems Cooled spray chamber Externally jacketed design Ethylene glycol mixture circulated to cool sample to -12 o C Reduces solvent load Made of quartz Excellent for highly volatile organic solvents e.g. naphtha Page 56

Sample and Standard Preparation Standard Preparation Multi-element organometallic standard (e.g. Conostan S-21) Select dilution ratio to achieve required concentration Add extra neutral base oil to ensure consistent viscosity Diluted with Isopropanol (iso propyl alcohol) Page 33

Detection Limit Performance (ppm) Element Instrument DL Al 167.019 nm 0.41 Al 396.152 nm 0.06 Ni 231.604 nm 0.23 Ni 216.555 nm 0.61 Mg 279.553 nm 0.05 Mg 280.270 nm 0.2 V 309.310 nm 0.04 V 292.401 nm 0.07 Ca 393.366 nm 0.05 Ca 306.847 nm 0.05 Ca 422.673 nm 0.04 Cr 267.716 nm 0.05 Page 62

Detection Limit Performance (ppm) Element Instrument DL Cd 214.439 nm 0.09 Cd 226.502 nm 0.10 Cd 228.802 nm 0.08 Cu 324.754 nm 0.06 Cu 327.395 nm 0.06 Fe 238.204 nm 0.06 Fe 259.940 nm 0.06 Mn 257.610 nm 0.06 Na 588.995 nm 0.05 Na 589.592 nm 0.04 Page 63

Page 38 Wear Metals Analysis

Rapid Wear Metal Analyses To improve sample throughput must look at: Sample introduction Instrument delays Rinse time Instrument setup and preventative maintenance time Page 41

Rapid Flow Fast Nebulization A triple channel peristaltic pump is required Channel 1: Waste removal Channel 2: Large ID tube for FAST FLOW sample introduction Channel 3: Narrow ID tube for control of flow into nebulizer Page 43

Rapid Flow Fast Nebulization Channel 1: Pump waste away from spray chamber Transfer line between large ID channel 2 tube to small ID channel 3 tube Channel 2: Large ID tube creates FAST FLOW from autosampler to channel 3 T piece diverts excess sample from channel 2 to waste To nebulizer From autosampler Page 44

Sample Throughput Throughput speed 2 orders of magnitude washout Using Cetac ASX 500 autosampler Sample Introduction System Rinse Time (s) Sample Throughput (s) Rapid flow fast nebulisation 11 39 Unmodified sample introduction 30 85 Page 45

Elemental Analysis of 25% Brine by ICP-OES Undiluted Analysis of 25% Brine Page Page 48 48

Application Papers Available on the Agilent Technologies Web site (http://www.agilent.com) SI-A-1413 Determination of metals in oils by ICP-OES SI-A-1417 Determination of V, Ni and Fe in crude oils and bitumen with Sc as an internal standard SI-A-1420 Determination of wear metals in lubricating oil with Axial ICP SI-A-1422 Determination of Pb in Unleaded Gasoline with Axial ICP SI-A-1423 Determination of trace elements in a xylene solution of oil by ICP-AES with ultrasonic nebulization and membrane desolvation SI-A-1427 Multi-element analysis of fuel and lubricating oils by simultaneous ICP-OES SI-A-1431 Improving Throughput for Oils Analysis by ICP-OES PLUS: SI-A-1202, SI-A-1415 and SI-A-1418 Page 49

Page 50