Axial piston pumps type PVPC with ISO mounting flange variable displacement, hydraulic control

Similar documents
Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

Solenoid directional valves type DPHI, DPHU

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Variable displacement axial piston pumps,

Variable displacement axial piston pumps,

Pressure relief valves type ARAM

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

2.3 MEDIUM HEAVY DUTY SERIES

Variable displacement axial piston pumps,

Variable displacement axial piston pumps,

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Variable displacement axial piston pump type V30D

2.4 HEAVY DUTY SERIES

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS

V Series AXIAL PISTON PUMP ORDER CODE

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Variable Displacement Pump A4VG for closed circuits

Series PVP Variable Volume Piston Pumps

Variable Displacement Open Loop Circuit Axial Piston Pumps AR Series

Output flow In l/min at 1500 min

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

THE PRODUCTION LINE OF PONAR WADOWICE

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E

Axial Piston Variable Double Pump A8VO

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

V Series AXIAL PISTON PUMP ORDER CODE

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series

A Series Variable Displacement Piston Pumps

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

Variable Displacement Pumps

P2060 P2075 P2105 P2145 P3105 P3145

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

TPV Variable Displacement Axial Piston Pumps CONTENTS. General Information. Installation Instructions. Technical Specifications 6-7

Series 20 Axial Piston Pumps. Technical Information

Axial Piston Variable Pump AA4VG

Safety directional valves with spool position monitoring

Flow sharing control block in mono block / sandwich plate design M6-22

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Axial Piston Variable Pump A4VG

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 160 / 0516 / E

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Flow sharing control block in mono block / sandwich plate design M6-15

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Series 20 Axial Piston Pumps. Technical Information

PLP Pump (up to 16 cm 3 /r max. 120 bar) PHV Pump (up to 32 cm 3 /r max. 250 bar) PVS Pump (up to 100 cm 3 /r max. 100 bar)

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

ISO cartridge valves type LIM*, LIRA, LIC*

AXIAL PISTON MOTORS SHMF

AXIAL PISTON PUMPS AND MOTORS

Variable Displacement Plug-In Motor A6VE

4.2 FIXED DISPLACEMENT DOUBLE PUMP

Axial piston variable pump A10V(S)O Series 31

Axial Piston Variable Pump A2VK

1.3 HIGH PRESSURE SERIES

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives Technical Data Sheet

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 154 / 0413 / E

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

Axial Piston Fixed Motor A2FM

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

EIPS2 INTERNAL GEAR PUMPS

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

PM50 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

Pilot-Operated Proportional DC Valve Series D*1FH

TPV 4000 (EX 28-41) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE TRANSMISSION LINE OF HANSA-TMP HT 16 / M / 280 / 1008 / E

Axial piston variable pump (A)A4VSO

Axial piston variable pump A10VSO Series 31

TPV Variable Displacement Closed Loop System Axial Piston Pump MANUFACTURING THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 403 / 1110 / E

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Axial Piston Variable Pump A4VG

Hydraulic Pump Series VP1 Variable Displacement

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

TPV 1000 (Ex 6-18) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 109 / 1008 / E

Axial piston variable displacement pump type V60N, Serie 03

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces:

Series TMM Axial Piston Motor. Technical Information

Axial piston variable pump A10VO Series 32

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Genuine Metaris MA10VO/VSO Technical Catalog. Variable Displacement Piston Pump - A10V Series 31 & 52

Transcription:

www.atos.com Table TA623/E Axial piston pumps type PVP with ISO mounting flange variable displacement, hydraulic control PVPH4046 PVP are variable displacement axial piston pumps for high pressure operation, with low noise level, suitable for hydraulic oils or synthetic fluids having symilar lubricating characteristics. The actual displacement is dependent on the lenght of stroke of the pumping pistons. This lenght of stroke is determined by the position of the swashing plate that is achieved by two servo pistons with differential areas, against a spring. The rotating barrel forces the pistons in a circular path in and out of the barrel and fluid displacement takes place. Typical section on side shows version H with manual pressure compensator and venting solenoid valve. The available hydraulic controls are shown in sections 8. The wide range of electrohydraulic proportional controls is shown in tab. TA72. ISO 309/2 mounting flange (D 6885 keyed shaft). Max displacement: 29467388 cm 3 /rev. Max pressure: 280 bar working 350 bar peak. MODEL ODE PVP X2E 4 046 / 3044 / M D I X 24D 0 /* Variable displacement axial piston pump Eventual suffix for double pumps X2E = with a fixed displacement pump type PFE (see tab. A005) Type of control (see section 8): = manual pressure compensator H = manual pressure compensator, with venting R = remote pressure compensator L = load sensing (pressure & flow) LW= constant power (combined pressure & flow) For electrohydraulic proportional controls, see table TA72 Series number Synthetic fluids: WG = waterglycol PE = phosphate ester See notes under section 2 Supply voltage, see section 5 : 00 = solenoid valve without coils (only for OI solenoid) X = without connector See section 4 for available connectors, to be ordered separately Size: 3 = for displacement 029 4 = for displacement 046 5 = for displacement 073 and 090 Max displacement of axial piston pump: 029 = 29 cm 3 /rev 046 = 46 cm 3 /rev 073 = 73 cm 3 /rev 090 = 88 cm 3 /rev Type of PFE (for double pumps), see tab. A005 ISO 309/2 mounting flange Solenoid of pilot valve: I = solenoid OI (DHI) for A and D supply Direction of rotation (viewed at the shaft end) D = clockwise S = counterclockwise Shaft: = keyed D 6885 2 OPERATG HARATERISTIS Pump model PVP*3029 PVP*4046 PVP*5073 PVP*5090 External load position Displacement [cm 3 /rev] 29 46 73 88 Theoretical max flow at 450 rpm [l/min] 42 66,7 05,8 27,6 Max working pressure / Peak pressure[bar] 280/350 280/350 280/350 250/35 Min/Max inlet pressure [bar abs.] 0,8 / 25 0,8 / 25 0,8 / 25 0,8 / 25 Max pressure on drain port [bar abs.],5,5,5,5 Power consumption at 450 rpm and at [kw] 9,9 3,6 50, 54, maximum pressure and displacement Type Type 5 Type Type 5 Type Type 5 Type Type 5 Max torque on the first shaft [Nm] 200 90 230 330 490 620 490 620 Max permissible load Fax 000 500 2000 2000 [N] on drive shaft Frad 500 500 3000 3000 Speed rating [rpm] 600 3000 600 2600 600 2200 600 850 Fax = axial load Frad = radial load Notes: For speeds over 800 rpm the inlet port must be under oil level with adequate pipes. Maximum pressure for all models with option /WG is 60 bar, with option /PE is 90 bar. Max speed with options /WG and /PE is 2000/900/600/500 rpm respectively for the four sizes. TA62

3 MA HARATERISTIS OF VARIABLE DISPLAEMENT AXIAL PISTON PUMP TYPE PVP Installation position Any position. The drain port must be on the top of the pump. Drain line must be separated and unrestricted to the reservoir and extended below the oil level as far from the inlet as possible. Suggested maximum line lenght is 3 m. Ambient temperature from 20 to +70 Fluid Hydraulic oil as per D 5524...535; for other fluids see section Recommended viscosity 5 00 mm 2 /sec at 40 (ISO VG 5 00). Maximum startup viscosity: 000 mm 2 /sec Fluid contamination class ISO 6/3 (filters at 0 µm value with ß0 75 recommended) Fluid temperature 20 +60 20 +50 (seals /WG) 20 +80 (seals /PE) 3. oils characteristics (for version H) Insulation class H onnector protection degree IP 65 Relative duty factor 00% Supply voltage and frequency See electric feature 5 Supply voltage tolerance ± 0% 4 ELETRI ONNETORS AORDG TO D 43650 FOR VERSION H The connectors must be ordered separately ode of connector SP666 SP667 Function onnector IP65, suitable for direct connection to electric supply source As SP666 connector IP65 but with builtin signal led, suitable for direct connection to electric supply source 5 ELETRI FEATURES FOR VERSION H Type of solenoid OI External supply nominal voltage ±0% () DIRET URRENT ALTERNATE URRENT 6 D 2 D 24 D 48 D 0/50 A (2) 20/60 A 230/50 A (2) 230/60 A Type of connector SP666 or SP667 SP666 or SP667 Power consumption (3) 33 W 60 VA (4) ode of spare coil SPOU6D /80 SPOU2D /80 SPOU24D /80 SPOU48D /80 SPOI0/50/60A /80 SPOI20/60A /80 SPOI230/50/60A /80 SPOI230/60A /80 olour of coil label brown green red silver yellow white light blue silver () For other supply voltages available on request see technical table E00. (2) oil can be supplied also with 60 Hz of voltage frequency: in this case the performances are reduced by 0 5% and the power consumption is 55 VA. (3) Average values based on tests performed at nominal hydraulic condition and ambient/coil temperature of 20. (4) When solenoid is energized, the inrush current is approx 3 times the holding current. Inrush current values correspond to a power consumption of about 50 VA. 6 STALLATION POSITION VERTIAL STALLATION D A B B B B The pump is supplyed whit drain open, and D plugged. Before installation fill the pump with hydraulic oil for at least 3/4 of its volume, keeping it in horizontal position. With exception of pump mounted below the oil level, we recomend to interpose a baffle plate between inlet and drain line. SIDE THE TANK Minimum oil level equal or above the pump mounting surface. A 200mm SIDE THE TANK Minimum oil level below the pump mounting surface. Minimum inlet pressure = 0,8 bar absolute B 800mm, = 200mm OUTSIDE THE TANK, above oil level Minimum inlet pressure = 0,8 bar absolute B 800mm, = 200mm HORIZONTAL STALLATION A SIDE THE TANK SIDE THE TANK OUTSIDE THE TANK, above oil level OUTSIDE THE TANK, below oil level Minimum oil level equal or above the pump mounting surface. A 200mm Minimum oil level below the pump mounting surface. Minimum inlet pressure = 0,8 bar (absolute) B 800mm, = 200mm Minimum inlet pressure = 0,8 bar (absolute) B 800mm, = 200mm = 200mm : inlet line D: drain line A: minimum distance between inlet and drain line B+: permissible suction height : inlet line immersion dept

7 DIAGRAMS at 450 rpm (based on mineral oil ISO VG 46 at 50 ) 7. Noise level curves The noise level has been measured in ambient conditions according to ISO 442 standards. Distance from microphone to pump = m. Measuring error = ± 2 db = Qmax = Qmin PVP*3029 PVP*4046 PVP*5073 and PVP*5090 7.2 Operating limits = Volumetric efficiency 4 = Power consumption with full flow 2 = Overall efficiency 5 = Power consumption at pressure compensation 3 = Flow versus pressure curve PVP*3029 PVP*4046 PVP*5073 Flow [l/min] Efficiency [%] 3 4 5 Power consumption [kw] Flow [l/min] Efficiency [%] Power consumption [kw] Flow [l/min] Efficiency [%] Power consumption [kw] Noise level [db] Noise level [db] Noise level [db] 2 4 3 5 2 3 5 4 2 7.3 Response times PVP*5090 7.3. Response times and pressure peack due to variation 0% 00% 0% of the pump displacement, obtained with an istantaneously opening and shutoff of the delivery line. Pump type T (ms) T2 (ms) PVP*3029 3 9 PVP*4046 44 20 PVP*5073 50 25 PVP*5090 52 27 Swashing plate angle αmax αmin Flow [l/min] Efficiency [%] 3 4 5 2 Power consumption [kw] Time [ms] 7.3.2 Variation of inlet pressure and reduction of displacement with increasing speed rating Speed rating [rpm/rpmmax] Inlet pressure [rbar abs.] Displacement rating [cm 3 /cm 3 max] TA62

8 HYDRAULI AND ELETROHYDRAULI ONTROLS Hysteresis and pressure increasing; max 4 bar Manual pressure compensator The pump displacement decreases when the line pressure approaches the setting pressure of the compensator. The pump supplies only the fluid required by the system. Pressure may be steplessly adjusted at the pilot valve. ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Flow [l/min] H Manual pressure compensator with venting As plus venting function, when a long unloading time is required and heat generation and noise have to be kept at lowest level. ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Flow [l/min] Hysteresis and pressure increasing; max 4 bar R Remote pressure compensator As, but with remote setting of the compensator by means of a pressure relief valve on the piloting line X. This version can be obtained from version L using a blind plug UNI 5923 M4x2 in pos.l and a restrictor M4 drilled ø 0,75 mm in pos.. ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Flow [l/min] Hysteresis and pressure increasing; max 4 bar not supplied L Load sensing The pump displacement is automatically adjusted to maintain a constant (load indipendent) pressure drop across an external throttle. hanging the throttle regulation, the pump flow is consequently adjusted. Load sensing control always incorporates an hydraulic compensator to limit the maximum pressure. ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Differential pressure setting range: 0 40 bar Differential pressure standard setting : 4 bar Flow [l/min] Hysteresis and pressure increasing; max 4 bar not supplied LW onstant power In order to achieve a constant drive torque with varying operating pressure. The swashing angle and therefore the outlet flow is varied so that the product of flow and pressure remains constant. For the best regulation, minimum working pressure is 80 bar. While selecting LW control, the required value of power must be communicated with the order (ex. 0 kw at 450 rpm). Flow [% of max] Minimum power curve 300 Maximum power curve Theoretical power curve

9 DIMENSIONS OF PVP*3029: BASI VERSION ONTROL PORTS DIMENSION = Flange SAE 3000 /4 OUT = Flange SAE 6000 3/4 D, = /2 BSPP = Regulation screw for max displacement,5 cm 3 /rev per turn. Adjustable range 50% to 00% of max displacement. In case of double pump the regulation screw is not always available, please contact our technical office. LET PORT OUTLET PORT OUT DRA PORT DRA PORT Mass: 8 kg SHAFT TYPE 200 Nm max TERMEDIATE FLANGE SAE A FOR PFE3 TERMEDIATE FLANGE SAE B FOR PFE4 SAE A SPLED 9 TEETH 6/32 PITH 00 Nm MAX SAE B SPLED 3 TEETH 6/32 PITH 35 Nm MAX OR2325 OR3400 Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted TA62

0 DIMENSIONS OF PVP*4046: BASI VERSION ONTROL PORTS DIMENSION = Flange SAE 3000 /2 OUT = Flange SAE 6000 D, = /2 BSPP = Regulation screw for max displacement 2,2 cm 3 /rev per turn. Adjustable range 50% to 00% of max displacement. In case of double pump the regulation screw is not always available, please contact our technical office. LET PORT OUTLET PORT OUT DRA PORT DRA PORT Mass: 24 kg SHAFT TYPE 230 Nm max TERMEDIATE FLANGE SAE A FOR PFE3 TERMEDIATE FLANGE SAE B FOR PFE4 SAE A SPLED 9 TEETH 6/32 PITH 35 Nm MAX SAE B SPLED 3 TEETH 6/32 PITH 250 Nm MAX OR2325 OR3400 Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted

DIMENSIONS OF PVP*5073 and PVP*5090: BASI VERSION ONTROL LET PORT OUTLET PORT OUT DRA PORT PORTS DIMENSION = Flange SAE 3000 2 OUT = Flange SAE 6000 /4 D, = 3/4 BSPP = Regulation screw for max displacement 3,2 cm 3 /rev per turn Adjustable range 50% to 00% of max displacement. In case of double pump the regulation screw is not always available, please contact our technical office. DRA PORT Mass: 33 kg SHAFT TYPE 490 Nm max TERMEDIATE FLANGE SAE A FOR PFE3 TERMEDIATE FLANGE SAE B FOR PFE4 SAE A SPLED 9 TEETH 6/32 PITH 35 Nm MAX SAE B SPLED 3 TEETH 6/32 PITH 330 Nm MAX OR2325 OR3400 TERMEDIATE FLANGE SAE FOR PFE5 SAE SPLED 4 TEETH 2/24 PITH 440 Nm MAX OR3400 Drawing show pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted TA62

2 DIMENSIONS OF PVP: OTHER ONTROLS VERSION H VERSIONS L, R VERSION LW TIGHTENG TORQUE = 5 Nm max = Regulation screw for max displacement. Adjustable range 50% to 00% of max displacement. In case of double pump the regulation screw is not always available, please contact our technical office. Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted and consequently also the position of the control groups Pump type PVP*3029 PVP*4046 PVP*5073 PVP*5090 Version A B D E Mass (kg) H L R LW H L R LW H L R LW 68 44 44 77 53 53 90 66 66 00 09 22 2 235 258 04 20 22 9,2 20 28 25,2 26 36,9 34,2 35 0/0