/ Series High Pressure Duplex Filters A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated balancing valve and vent ports. Microglass lll glassfibre media is standard. Maximum pressure upstream side of the filter, ensuring a contamination free system. Contact Information: European Product Information Centre Freephone: 8 27 27 5374 (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: balancing valve and vent ports. change. www.parker.com/hfde 175 FDHB5UK.
/ Series High Pressure Duplex Filters Features & Benefits Features Duplex design Vent ports Visual, electrical and electronic indicators available Advantages Element service possible during operation Purges all trapped air in filter Multi-layered design produced high capacity and efficiency Wire support reduces pleat bunching, keeps performance consistent Check element condition at a glance Right style for the application Benefits full contamination protection Safety and reliability Get the maximum performance from the elements Prevents a "flabby" system Great performance value Reliable performance throughout element life Reduces downtime, maximises element life Optimises element life, prevents bypassing Matches your system electrical connections Typical Applications Ship steering systems Continuous operation industrial systems High flow flushing systems The Parker Filtration / Series High Pressure Duplex Filters. Specially designed to offer continuous operation, even during element change. of the filter, ensuring a contamination free system. FDHB5UK.
Specification Pressure ratings: Maximum allowable operating pressure 21 bar. Filter housing pressure pulse fatigue tested: 1 cycles 21 bar. Connections: Connection style Model BSPF(G) 1 1 1 /4 1 /4 1 1 /2 Filter housing: Bowl material steel. Seal material: or Fluoroelastomer. Operating temperature range: Seal material : -4 C to +1 C. Seal material Fluoroelastomer: -2 C to +12 C. Bypass valve: Opening pressure Filter element: Degree of filtration: Flow fatigue characteristics: Filter media is supported so that the optimal fatigue life is achieved Microglass III: Supported with epoxy coated metal wire mesh, end cap material reinforced composite and metal inner core. Collapse rating 2 bar High collapse elements: (to be used when no bypass function in filter housing). upstream and stainless steel on downstream, end cap material steel. Indicator options: - visual M3. - electrical T1. - electronic F1(PNP). - electronic F2(NPN). Weights (kg): Model Length 1 22 27 44 5 Fluid compatibility: Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration. Dimensions mm (inches) Model A B C D E F G H I J K L M N -1 22-PD-2-1 -2 24 (9.45) (1) 35 (1.38) 42 92 13 (5.12) 18 (.71) 2 (.79) 55 78 (3.7) 15 (5.91) 17 32 (2.21) 33 (2.28) (3.7) 12 (4.72) 192 24 (9.45) 75 (2.95) 3 (1.18) (1.42) 59 (2.32) 7 (2.75) 3.75Ø 38Ø 345 (13.58) 317 (12.48) 437 (17.2) D Out B mm (inches) J G E N 4 mounting holes : M8x1.2 pitchx12 deep : M1x pitchx15 deep H 2 bleed holes G 1 /8 F Changeover handle Balance valve Bleed valve Hexagon C Bowl removal 1mm (3.93) Flange face detail L M12x1.72 pitch x2 deep M K 177 FDHB5UK.
/ Series High Pressure Duplex Filters Pressure Drop Curves The recommended level of initial pressure drop is max. 1.2 bar. p = ( p3 x viscosity of medium used) / 3 cst. The total p = housing ph + (element pe x working viscosity/3). / Bypass Valve 13 26 39 53 66 79 92 16 3. / Empty Housing 13 26 39 53 66 79 92 16 2. 29. 2. 1..5 Cracking Pressure 29. 1..5. 5 1 15 2 25 3 35 4. 5 1 15 2 25 3 35 4-1 Elements 3. 13 26 39 53 66 79-2 Elements 3. 13 26 39 53 66 79 2. 1..5 2Q 5Q 1Q 2Q 29. 2. 1..5 2Q 2Q 5Q 1Q 29.. 5 1 15 2 25 3. 5 1 15 2 25 3-1 Elements -2 Elements 13 26 39 53 66 79 3. 3. 13 26 39 53 66 79 2. 1..5. 29. 2Q 5Q 1Q 2Q 5 1 15 2 25 3 2. 1..5. 29. 2Q 5Q 1Q 2Q 5 1 15 2 25 3 178 FDHB5UK.
-1 High Collapse Elements 3. 13 26 39 53 66 79-2 High Collapse Elements 3. 13 26 39 53 66 79 2. 1. 2QH 5QH 1QH 2QH 29. 2. 1. 2QH 5QH 1QH 2QH 29..5.5. 5 1 15 2 25 3. 5 1 15 2 25 3-1 High Collapse Elements -2 High Collapse Elements 13 26 39 53 66 79 3. 13 26 39 53 66 79 3. 2. 1..5 2QH 5QH 2QH 1QH 29. 2. 1..5 2QH 5QH 1QH 2QH 29.. 5 1 15 2 25 3. 5 1 15 2 25 3 Ordering Information Standard products table Part number 21QBM3KG161 21QBT1KG161 22QBM3KG161 22QBT1KG161 21QBM3KG21 21QBT1KG21 22QBM3KG21 22QBT1KG21 Supersedes -22-PD-2-1Q-V-5-C-1-22-PD-2-1Q-TW3-5-C-1-22-PD-2-2Q-V-5-C-1-22-PD-2-2Q-TW3-5-C-1-32-PD-2-1Q-V-5-D-1-32-PD-2-1Q-TW3-5-D-1-32-PD-2-2Q-V-5-D-1-32-PD-2-2Q-TW3-5-D-1 Flow (l/min) 12 12 14 14 24 24 Model number Element length Media rating (µ) Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above. 1 1 2 2 1 1 2 2 Seals Indicator Visual Electrical Visual Electrical Visual Electrical Visual Electrical Bypass settings Ports G1" G1" G1" G1" G1 1 /4" G1 1 /4" G1 1 /4" G1 1 /4" Replacement elements G1315Q G1315Q G1938Q G1938Q G198Q G198Q G1954Q G1954Q Part Number S4233 S4234 S4234 S4234 / Series Seal Kits Description 179 FDHB5UK.
/ Series High Pressure Duplex Filters Ordering Information (cont.) Product configurator Box 1 Box 2 2 Box 3 1Q Box 4 B Box 5 M3 K Box 7 G16 Box 8 1 Box 1 Model Small high pressure duplex filter Large high pressure duplex filter Box 2 Length Length 1 Filter type 1 2 Box 3 Element media High collapse element Degree of filtration Glass fibre Media code 2Q 2QH 5Q 5QH 1Q 1QH 2Q 2QH Box 4 Seal type Seal material Fluoroelastomer B V Box 5 Visual indicator Electrical indicator Plugged with steel plug No indicator port Electronic 4 LED, PNP, N.O. Electronic 4 LED, NPN, N.O. Electronic 4 LED, PNP, N.C. Electronic 4 LED, NPN, N.C. Indicator M3 T1 P N F1 F2 F3 F4 Bypass and indicator settings Bypass valve No bypass No bypass Indicator bar 5. bar No indicator K M X When filter includes a bypass valve but not an indicator, code denotes bypass setting. + Box 8: code 2 + Box 8: code 2 Box 7 Filter connection Ports : Thread G 1 1 /4" 3-M : Thread G 1 1 /4 1 /2" 3-M G16 R2 G2 R24 Box 8 Options Standard No bypass Options 1 2 Media 2Q 5Q 1Q 2Q 2QH 5QH 1QH 2QH Media 2Q 5Q 1Q 2Q 2QH 5QH 1QH 2QH Replacement elements with nitrile seals -1 G1282Q G2721Q G1281Q G193Q G1442Q G3737Q G1441Q G1932Q -2 G1316Q G2724Q G1315Q G1938Q G1448Q G3738Q G1447Q G194Q -1 G169Q G2567Q G168Q G1946Q G1454Q G3739Q G1453Q G1948Q -2 G199Q G2727Q G198Q G1954Q G374Q G1459Q Replacement elements with fluoroelastomer seals -1 G132Q G2723Q G131Q G1934Q G4235Q G1445Q G1935Q -2 G1335Q G1942Q G1452Q G1451Q G1943Q -1 G189Q G188Q G195Q G1458Q G4237Q G1457Q G1951Q -2 G1119Q G2729Q G1118Q G1958Q G4238Q G1959Q Filter model -1-2 -1-2 Filter model Nominal flow (I/min) at viscosity 3 cst 2Q 7 1 1 18 Seal kits S4233 S352 123 123 123 123 5Q 8 11 15 21 Fluoroelastomer S4234 S3522 1Q 1 12 21 24 2Q 12 14 23 Highlights Key (Denotes part number availability) Note: Standard items are in stock, semi standard items are available within four weeks ßx(c)=2 5.% Degree of filtration Average filtration beta ratio ß (ISO 16889) / particle size µm [c] ßx(c)=1 ßx(c)=75 ßx(c)=1 ßx(c)=2 ßx(c)=1 % efficiency, based on the above beta ratio (ßx) 9.% 11 98.7% 4.5 8.5 17 99.% 5 9 18 99.5% 1 2 99.9% 4.5 7 12 22 Disposable 2Q 5Q 1Q 2Q High collapse element 2QH 5QH 1QH 2QH Note 1: Part numbers featured with bold highlighted codes will ensure a standard product selection. 18 FDHB5UK.
Indicators Series FMU p-indicators and Pressure Indicators Max 42 bar Measuring critical system parameters is essential Reliable and continuous control of the filter in all applications The FMU range of filter condition indicators are designed for use on a wide range of Parker filters and competitive interchange filters. Maximum pressure 42 bar. A comprehensive range of high quality indicators for mobile, industrial and marine applications. Contact Information: European Product Information Centre Freephone: 8 27 27 5374 (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: on a wide range of Parker filters. feedback. www.parker.com/hfde 181 FDHB5UK.
Indicators Series FMU p-indicators and Pressure Indicators Features & Benefits Features Indicators fatigue tested to full pressure rating Cartridge screw-in type indicators Visual, electrical and electronic indicators available Several indication settings Visual indicators Electrical indicator with change-over switch Electrical indicator with 4 LEDs Programmable and ATEX certified indicators available Advantages Reliable indicators for heavy duty applications Easy mounting Check element condition at a glance Right style for the application Optimized for each bypass setting Local monitoring of the element condition Option of Normally Open (N..) and Normally Closed (N.C.) function Thermal lock-out Visual early warning with yellow LED Pre-alarm with yellow LED and wired output Alarm with red LED and wired output Right indicators for special applications Benefits Reliable and continuous control of the filter in all applications Reliable sealing, no leakage Optimises element life, prevents bypassing Match your system s electrical connections Right indicator for application Reliable low cost indicator Approved for low voltage and high voltage use including machine control systems and PLC s No false alarm because of low temperature oil Allows time to schedule element change Indicates upcoming element change Clear indication for element change Improved machine surveillance Typical Applications Industrial equipment Mobile equipment Marine/offshore applications The Parker FMU Series Differential Pressure Indicators The FMU range of filter condition indicators, are designed for use on a wide range of Parker filters and suitable for competitive interchange (consult Parker Filtration for details). Ideal for giving accurate visual, electronic or electrical feedback of filter element condition, in order to facilitate effective maintenance and ensuring hydraulic systems, marine/mobile or industrial are protected from particulate contamination. 182 FDHB5UK.
Specification Maximum operating pressure: 42 bar (25 bar for aluminium). Maximum differential pressure: 21 bar. Working temperature range: -2 C to +85 C with fluoroelastomer seals, -4 C to +85 C with nitrile and EPDM seals. Material of housing: Brass, aluminium or stainless steel. Seals: Fluoroelastomer, or EPDM. Mounting torque: max. 75 Nm (max. 5 Nm for aluminium indicator body & filter housing) The differential pressure values of standard indicator models: 1.2 bar ±.2 bar ±.2 bar ±.3 5. bar ±.5 7. bar ±.5 8.5 bar ±.5 (Indicators for other differential pressure values are optional). FMU p Indicators are typically used with the following filters: Heavy duty filters: GS, SF14, DF235, DF25, DFH26, DF27, DF289, DF211 Note: FMU-Block is required to connect indicator to filter. Medium pressure filters series: 45M. High pressure filters series: 7L, 7T, 7B, 5, 71 and 72. Heavy duty filter series: 13M, DF2145. High pressure filters without bypass valve: 7L, 7T, 7B, 71 and 72. Medium and low pressure filter series; Note for PD Range only bar indicators are available: 15CN, 4CN, 8CN,,, 15P, 3P, 4RF, 5RF, IL8, 12M, 22M, 16P, 26P, 36P. Also heavy duty filter DF4. High pressure filters 18P, 28P, 38P, FDA, FDB U12H U12H U12H U14M U14H 1. and bar bar 7. bar 1.2 and bar and 5. bar 183 FDHB5UK.
Indicators Series FMU p-indicators and Pressure Indicators FMUT Electrical Rated voltage Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load Inrush current (A) N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. 125VAC 5.7 3 1.3 25VAC 3 1..5 2.8 8VDC 5 2 5 4 3 14VDC 5 2 4 4 3 3VDC 4 2 3 3 3 125VDC.4.5.4.4.5 25VDC.2.3.2.2.3 2 max. 1 max. Enclosure class IP65 Electrical connector DIN 4365 Overvoltage category II (EN611-1) Contact configuration P1-P2 Rotating part 36 COM Indication (N.O) Normally closed (N.C) No connect P1 high pressure P2 low pressure FMUM3 Visual Auto Reset/FMUM1 Visual Manual Reset Operation Red colour visible when indicator on U12H model ø24 M1-type push here for reset Operation U14M model Red colour visible when indicator on U14H model 6 Fixed part 27.5 75 ¾-16 UNF-2A High pressure Low pressure 27.5 55.5 3 /4-16 UNF-2A 32 Low pressure High pressure 7 /8-14UNF - 2A + + ø19.78 -.6 ø18.83 -.6 Note: Only FPUM3 visual auto reset available for models U14M and U14H. FMUM1 not available. 7 /8-14UNF - 2A 184 FDHB5UK.
FMUF Electronic Contact configuration U12H model NPN FMU F NPN 3 1 2 Load Load +V +1...36 Vdc Rotating part 36 4 V max 3 ma Green LED Yellow LED s PNP Red LED Fixed part A U12H U14M U14H A 98 15 15 B 27.5 32 32 C Ø16.2 Ø19.78 Ø18.83 ±.5 ±.6 ±.6 D 3 /4-16 7 /8-14 7 /8-14 UNF-2A UNF-2A UNF-2A FMU F PNP 3 1 Load +V +1...36 Vdc High pressure B 4 2 Load max 3 ma Thermal lock-out (standard setting +2 C) Indicator operates only when temperature is above setting. Green LED is blinking if temperature is lower. (not in U12H) Ind. press. setting Enclosure class Electrical connector Input supply voltage *Indication output Output type: LED status G Y1 Y2 R < 5 % - 5 % - Note: Do not connect output terminals 1 or 2 directly (without load) to power supply terminals, because this will damage the equipment. FMUL1 Programmable Dimensions: see FMUF electronic p-indicator V Output 75 % 2 active 1 % 1 active Low pressure IP65 DIN 4365, cable connection PG9 or optinally M12 4-pin +1 to 36 Vdc max. 3 ma/36 Vdc N.O. or N.C./NPN or PNP C D U14M model C D B Low pressure High pressure U14H model Safety feature: The 25 bar U14M indicator does not fit into the U14H cavity, which is used in 42 bar filters Programmable p-indicator All settings adjustable (settings made via PC) Connections cable and software available from Parker 1 /2 years C D 185 FDHB5UK.
Indicators Series FMU p-indicators and Pressure Indicators Ordering Information Product configurator Box 1 Box 2 FMU M3 Box 3 K Box 4 V Box 5 M Box 6 U14 Box 7 H Box 8 Indicator series Filter monitoring unit FMU Box 2 Filter type Differential pressure indicator Visual manual reset Visual autoreset Electrical Electronic 4 LED, PNP, N.O. Electronic 4 LED, NPN, N.O. Electronic 4 LED, PNP, N.C. Electronic 4 LED, NPN, N.C. Programmable with memory logs Ex version M1* M3 T1 F1 F2 F3 F4 L1 X1 Box 3 Indicator setting 1. bar (14 psi) 1.2 bar (17 psi) bar (21 psi) bar (35 psi) 5. bar (7 psi) 7. bar (98 psi) 8.5 bar (125 psi) Standard settings: a: U14M, former -W3 b: U14H, former -W6 c: U12H, former -F6 Indicator setting Standard c a c a, b, c b c F G H K M N P Box 4 Seal material Fluorelastomer EPDM Neopren Seal type B V E N Box 5 Indicator body Indicator body Aluminium (Box 7, code M) Brass (Box 7, code M and H) Stainless steel A M R Box 6 Thread connection Thread connection 3 /4" - 16UNF-2A 7 /8" - 14UNF-2A U12 U14 Box 7 A - class products Max Pressure Max pressure CN, 15/3P & 22/32 PP Series 45M, 13M, 7P & 18/28/38P M H Box 8 Options Standard Other options Options omit factory supplied Note: F and L type indicators. Non-standard thermal lockout settings shown here. FMUX ATEX Approved Electronic Ø 32 57 Cable 1 meter Specification: zone 1): Ex II 2 GD Eex m II T6 kmax : 1A Indicator type X1: ATEX p-indicator Electronic indicator accordant with ATEX 94/9/EC directive: (Ex) II 2 GD Eex mii T6. Degree of protection IP66. X1 refers to NPN, N.O. (see electronic F Type). Other output options are available by request. Connection cable + software for programmable indicator L1 Connection cable for PC serial connection and software for indicator settings and utilising memory logs. Ordering : 95753 Seal kits (fluoroelastomer) Ordering code Indicators with thread connection U12H (former -F6) 9114578 Indicators with thread connection U14M (former -W3) 9114586 Indicators with thread connection U14H (former -W6) 9114587 HEX 24 (Ø 26.5 mm) 3/4-16UNF-2A U12H(F6) shape Note 1: Part numbers featured with bold highlighted codes will ensure a standard product selection. Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability. 186 FDHB5UK.
Pressure Indicators for Low Pressure Filters ETF Filter Visual pressure indicator G2 mm (inches) G 1 /8 48 Vdc electrical indicator 1. bar S2/S3 mm (inches) 31 (1.22) 25 VAC electrical indicator 1. bar S4 mm (inches) Rotating part 36 3 (1.18) x3 (1.18) 38 (1.49) 4 (7) 67 (2.64) HEX 24 (.94) 56 (2.2) 44 (1.73) C3 2 NO 1 NC 74 (2.91) 32 (1.26) 1 (.39) Option Description Connection/Voltage Wiring Part number G 1 /8K HEX 27 (1.6) G 1 /8K 1 (.39) Fixed part G2 Visual indicator 1. bar N/A N/A FMUG2EBPG2L S2/S3 Electrical indicator 1. bar 42 Vdc max Select either normally open (NO) or normally closed (NC) FMUS2FBMG2L (NO switch) or FMUS3FBMG2L (NC switch) Normally open contacts S4 Electrical indicator 1. bar 25 Vac max 1 NC 2 NO 3 C FMUS4FBMG2L TTF, BGT and TPR Indicator PS pressure switch Protective cap with dual cable duct for 1, 7-2, 3mm diameter cable Indicator PS NO/NC pressure switch Protective cover Normally open contacts 9 75 Amp 6.3x8 terminals 2 3 1 Switch 58 27 A/F 1 = COM. 2 = N.C. 3 = N.O. 24 A/F 9 Normally closed contacts 74 Normally closed contacts 55 G 1 /8 G 1 /8 (BSP) Ø3.5 Ø28 Elec.rating Thread connection Elec.connection Protection Specifications 42V / 4A G 1 /8 AMP 6.3x.8 terminals + protective cap IP65 (with cap) terminals IP FMUS14EBMG2 L (Switch) Specifications Elec.rating 42V / 2A Thread connection G 1 /8 Elec.connection AMP terminal 6.3x.8 Protection IP65 (terminal IP) Switch type NO or NC FMUS2EBMG2L (NO switch) FMUS3EBMG2L (NC switch) Visual indicator G 1 /8: code 1.2 bar FMUG2EBPG2L 187 FDHB5UK.