Technical Specificaions. kwh Energy Meter

Similar documents
Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Helena Snyman - Technical Manager and Sydney Bhengu - Customer Support Technologist Elster Kent Metering (Pty) Ltd. South Africa

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Freedom egen System End-of- Line Functional Checklist

Micro Controller based Motor Protection Relay & Motor Management System

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

English. Instruction and operation manual S 110. Power Meter

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

Quick Start Guide TS 910

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS

ICON 2 1. FEATURES AND CHARACTEIRICS

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

OPERATING INSTRUCTIONS MCP-MT1

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

OPERATING INSTRUCTIONS ECON-M

TIME REQUIREMENT GUIDE (TRG)

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

USERS MANUAL MCD REMOTE OPERATOR

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Quick Start Guide TS 910 & TS 920

Photovoltaics. MPI Hybrid Series

Induction Power Supplies

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation Instructions

premier product range

Contact Details: Mail Id:

H- or J-Frame Main Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

Instruction Bulletin Dual Sub-Feed Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Technical Data Sheets

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

Polaris 1000 User s Manual

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

J1000. Compact Inverter Series.

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Auto Mains Failure AMF Controller AE10113

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Quick Connection Panel (QCP) Installation Guide

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

H81xx Energy Meter. H81xx NOTICE DANGER INSTALLATION GUIDE QUICK INSTALL POWER MONITORING

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

ibusway for Data Center

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

University of Houston Master Construction Specifications Insert Project Name

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

COUNTIS E22 Three-phase energy meter Direct - 80 A

GCU-10. Automatic Engine Control Unit Operators Manual

Phone: Fax: Web: -

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

AuCom - Soft Starters

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

EM DC Multi-Function DC Energy Meter

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

INTECH Micro 2300-RTD6

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Vission 20/20 micro-controller. Operation and service manual Version 2.6

Technical Data Sheets

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Delta Products VFD CP2000 Bypass Control Packages.

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

1.Safe testing IMPORTANT:

SMT-150 Installer Manual

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

ACM3P Series. Three-Phase AC Ammeters. FEATURES PRODUCT OVERVIEW

Operator s Series 300 Generator Paralleling System

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

DEEP SEA ELECTRONICS PLC

Installation Instructions & Users Manual

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

I n s t a l l a t i o n M a n u a l. f o r T E D

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

PowerView PV380-R2 Mechanical Configuration

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Transcription:

Technical Specificaions of kwh Energy Meter (SPK300) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com Phone : 044-43192660 1

General Specifications 1) GENERAL: Meter measures Active Power and Active energy on 3 phase 4 wire system, All four quadrant measurement for KWh are measured and stored in energy accumulators, Parameters can be viewed through 7 segment LED (3 row), Soft Keys are provided to stop, scroll, edit and to view the parameters, RTC with battery backup is used for time keeping and has a calendar of 100 years, Power Line Communication can be done using RS485 communication with MODBUS RTU, 2) METER FEATURES: 2.1) Display Details: 7 segment (3*4 digits) LED type The parameters are calculated by the meter are displayed, Selectable Parameters Can select any out of 7 parameters. Scroll rate The scroll rate of the display parameter scroll in steps of 4secs. Keys are provided to stop, scroll, edit and to view the particular parameter. 2.1.1) Display Parameters: Time, Date, Meter ID with Phase Sequence, Frequency (Hz.), Cumulative RYB Active Energy (KWh), Instant Active Power KW R,Y,B, Instant KW RYB. 2

2.2) Key Features: The Parameter setup can be done through 4 nos. of soft keys on front fascia, Keys on the front panel is used to scroll, increment, decrement through display parameter, to set the Meter ID, Time, Date, Energy Reset, Change Password Press scroll key once the parameter set is completed, this allows to view the parameters one after the other automatically (change over time period is 4 secs). If this is not done auto scroll will not happen. 2.3) Rear Terminal Details: 3

2.5) Safety Precautions: HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions. If the equipment is not used in a manner specified by the manufacturer, the protection provided by the equipment may be impaired. NEVER work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all sources of electric power. Assume that all circuits are live until they have been completely de-energized, tested, and tagged. Pay particular attention to the design of the power system. Consider all sources of power, including the possibility of back feeding. Turn off all power supplying the dual energy meter and the equipment in which it is installed before working on it. Always use a properly rated voltage sensing device to confirm that all power is off. Before closing all covers and doors, inspect the work area for tools and objects that may have been left inside the equipment. When removing or installing panels do not allow them to extend into the energized bus. The successful operation of this equipment depends upon proper handling, installation, and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property. NEVER bypass external fusing. NEVER short the secondary of a PT. NEVER open circuit a CT High voltage testing may damage electronic components contained in the kwh meter. Ensure that no wiring strands are straying outside after connecting wires. kwh Meter should be installed in a suitable electrical enclosure. Failure to follow these instructions will result in death or serious injury 4

Technical Specifications Accuracy : Class 1.0S System type : 3 Phase 4 Wire Resolution : 0.01 (for Combined kwh) Display : Multi Parameter LED (3 ROW) Auxiliary Supply : 85 265 VAC Current CT : Whole Current (External) (10 60)A Starting Current : 10mA Power Factor : 4 quadrant operation Frequency : 50Hz, ±5% Temperature : Operating Temp. (-10 to 55) C Storage Temp. (-20 to 70) C Humidity 5 to 95% RH at 50 C (Non-Condensing) Dimension : (96 x 96 x 48) mm (Inclusive of connector) Panel Cutout : 92 x 92 mm (-0.5mm) Mounting : Panel Mountable Connector Type : Screw type terminals (U Lug 2.5mm) Weight : 350gms. (app.) 5