General Installation Instructions LED To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings and instructions included with and on the luminaire box and all luminaire labels. Before installing, servicing or performing routine maintenance upon this equipment, follow these general precautions. Installation and service of luminaires should be performed by a qualified licensed electrician. Maintenance of the luminaires should be performed by person(s) familiar with the luminaires construction and operation and any hazards involved. Regular luminaire maintenance programs are recommended. It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, nonabrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/ lens and clean in above manner, replacing damaged gaskets as necessary. DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes, this matter should be referred to Acuity Brands Lighting, Inc., a parent company of Peerless Lighting. RISK OF ELECTRIC SHOCK 4 Disconnect or turn off power before installation or servicing. 4 Verify that supply voltage is correct by comparing it with the luminaire label information. 4 Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. 4 All wiring connections should be capped with UL approved recognized wire connectors. 4 To prevent luminaire row from over- current: By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating whichever the least. RISK OF BURN 4 Allow lamp/luminaire to cool before handling. Do not touch enclosure or light source. 4 Do not exceed maximum wattage marked on luminaire label. 4 Follow all manufacturer s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. Part Number: PIN004102 Description: INSTR, IMPORTANT SAFETY LED Revision: C Effective Date: 07/2012 ECO3665 page 1 of 2 General Installation Instructions LED A
General Installation Instructions LED RISK OF INJURY 4 Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. 4 Avoid direct eye exposure to the light source while it is on. RISK OF FIRE 4 Keep combustible and other materials that can burn away from lamp/lens. 4 Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. RISK OF PRODUCT DAMAGE 4 Never connect components under load. 4 Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation. 4 Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED luminaires must be powered directly off a switched circuit. 4 Unless individual product specifications deem otherwise: Do not restrict luminaire ventilation. Allow for some volume of airspace around luminaire. Avoid covering LED luminaires with insulation, foam or other material that will prevent convection or conduction cooling. 4 Unless individual product specifications deem otherwise: Do not exceed luminaire s maximum ambient temperature. 4 Only use luminaire in its intended location. 4 LED products are polarity sensitive. Ensure proper polarity before installation. 4 Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit. 4 Do not touch individual electrical components as this can cause ESD, shorten lamp life or alter performance. 4 Some components inside the luminaire may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact a Peerless Lighting representative for assistance. 4 Always read the fixtures complete installation instructions prior to installation for any additional luminaire specific warnings. SAVE THESE INSTALLATION INSTRUCTIONS Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit PeerlessLighting.com. Peerless Lighting, an Acuity Brands Company, assumes no responsibility for claims arising out of improper or careless installation or handling of its products. Part Number: PIN004102 Description: INSTR, IMPORTANT SAFETY LED Revision: C Effective Date: 07/2012 ECO3665 page 2 of 2 General Installation Instructions LED B
General Installation Instructions To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other hazards: Service of the equipment must be performed by qualified service personnel. Installation and maintenance must be performed by a person familiar with the construction and operation of this product and any hazards involved. All applicable codes and ordinances must be followed. Read this document before installing, servicing or maintaining this equipment or installing a lamp. These instructions do not cover all installation, service and maintenance situations. If your situation is not covered, or, if you do not understand these instructions or additional information is required, contact Peerless Lighting or your local Peerless Lighting distributor. Read and follow all warnings and instructions provided by the lamp manufacturer. Before installing, servicing or maintaining this equipment, follow these general precautions. To reduce the risk of electrocution: Make sure the equipment is properly grounded. Always de-energize the circuit and/or equipment before connecting to, disconnecting from or servicing the equipment. To prevent luminaire row from over-current: By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating whichever is the least. To reduce the risk of fire: Keep material away that can burn from hot lamp. Make sure lamps are correctly installed. Use supply conductors with a minimum installation temperature rating as specified on equipment. To reduce the risk of personal injury from cuts, abrasions or falling parts: Wear gloves to prevent cuts or abrasions from sharp edges when removing from carton, handling and maintaining this equipment. Do not use abrasive materials, glass cleaners or other solvents on reflector or lens. These substances may damage equipment and cause parts to eventually break and fall. Do not install a damaged fixture. Observe lamp manufacturer s recommendations and restrictions on lamp operation including but not limited to ballast type, burning position, replacement and cycling. Use only lamps that comply with applicable ANSI standards. NOTICE: If lamp is marked it contains mercury. Follow disposal laws. See www.lamprecycle.org Peerless Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for claims arising out of improper or careless installation or handling of this product. SAVE THESE INSTALLATION INSTRUCTIONS Part Number: PIN004100 Revision: E Effective Date: 07/2012 ECO3665
Staple Suspended LED and Fluorescent INSTALLATION INSTRUCTIONS PIN005900 REV. D 04/14 ECO3722 SPM9L/SPM9/SPM4 These installation instructions are used for installing the following luminaires and kits: Luminaires Support Location Adjustable Mounting Kit SPM9L Normal Power Feed ACG4FKMTY SPM9 Emergency Power Feed ACG4EKMTY SPM4 Non-Power Feed ACG4SKMT Luminaire End Cap Kit Dust Cover VDR Kit SPM9L SPM9EP or SPM9FEP SPM9LDU SPM9LVDR SPM9 SPM9EP or SPM9FEP SPM9DU SPM9VDR SPM4 SPM9EP or SPM9FEP SPM9DU SPM9VDR : Please read the important safety instructions prior to installation of this product. The mounting instructions can be found inside the mounting kits or downloaded from PeerlessLighting.com. A) Identification of SPM9L, SPM9 and SPM4 Luminaires...Page 1 B) Cable-Mounted Installation...Page 2 C) OPTIONAL Dust Cover (DU) Installation...Page 3 D) OPTIONAL Variable Distribution Reflector (VDR) Installation...Page 3 A) Identification of SPM9L, SPM9 and SPM4 Luminaires SPM9L & SPM9 SPM4 NOTE: The Y-cable hanger for the first section of a continuous run is locatd in the end cap kit in the red hardware box. Aircraft Cable Y-Cable Hanger Cord Manager Y-Cable Hanger Details Round (EP) End Cap Squared (FEP) End Cap Wire Connectors DIMENSIONS OF STANDARD SECTION Nominal Support Spacing is 4, 8 and 12 U12 U8 U4 Llimited warranty applies. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx StapleSuspended LEDandFluorescentinstallationinstructions 1
Staple Suspended LED and Fluorescent PIN005900 REV. D 04/14 ECO3722 SPM9L/SPM9/SPM4 B) Cable-Mounted Installation 1 2 3 For individual luminaire (with IND option), raise the luminaire into position. Insert aircraft cable in to the gripper of the Y-Cable hanger. Tighten all safety caps and thumb lock screws on all Y-Cable hangers. Connect power cord to line wires and install cord manager to complete the installation. For modular luminaires, insert power cord and bushing through knockout of the first luminaire at the male connector end. Plug in the wire connectors. Hook the Y-Cable hanger onto joiner and press on tabs on joiner to secure. Fold or break the aligner tab on joiner near power cord, install and secure end-cap. Raise the luminaire into position. Insert aircraft cable in to the gripper of the Y-Cable hanger. Tighten all safety caps and thumb lock screws on all Y-Cable hangers. 4 5 6 Raise the connecting luminaire into position. Insert aircraft cable in to the gripper of the Y-Cable hanger. Plug in the wire connectors. (Refer to Section D, Step 2 if installing SPM9L with a distribution of 0/100.) Connect the luminaire at the joiner location. Repeat Steps 4-5 as necessary to hang all luminaires in the row. For modular fluorescent luminaires (left). Bolt luminaires together with (2) ¼-20 screws using a Philips screwdriver. For modular LED luminaires (right). Bolt luminaires together with (2) ¼-20 socket head screws using a 3/16 socket allen wrench. Fold or break the aligner tab on joiner, install end-cap. Level the whole row at each hanger location as necessary. Tighten all safety caps and thumb lock screws on all Y-Cable hangers. Connect power cord to line wires and install cord manager to complete the installation. 7 Optional nlight CAT5 connection. Where applicable, plug in the CAT5 cable (provided in the mounting kit) to complete the installation. Image on left shows SPM9 and SPM4 (fluorescent). Image on right shows SPM9L (LED). Staple Suspended LED and Fluorescent 2
Staple Suspended LED and Fluorescent PIN00590 REV. D 04/14 ECO3722 SPM9L/SPM9/SPM4 C) OPTIONAL Dust Cover (DU) Installation 1 2 For SPM9L (LED), simply remove the dust cover for cleaning during maintenance and then restore the part by overlaying it atop the luminaire as shown. For SPM9 AND SPM4 (Fluorescent), simply remove the dust cover to re-lamp during maintenance and then replace the dust cover centering it over the lamp(s) as shown. D) OPTIONAL Variable Distribution Reflector (VDR) Installation 1 2 3 For optional VDR on SPM9L (LED) with 60/40, 50/50, 40/60 or 20/80 distribution. Secure VDR to luminaire housing with (6) #8 screws as shown after maintenance or retrofitting. For optional VDR on SPM9L (LED) with 0/100 distribution. Fold down the tabs on the ends of the VDR as part of Section B, Step 4 for standard luminaire installation, maintenance and retrofitting. For optional VDR on SPM9 and SPM4 (Fluorescent) with one or two lamps. Place VDR over the lamp assembly as shown after maintenance or retrofitting. 4 For optional VDR CLI on SPM4 (Fluorescent) with three lamps. Place the VDR CLI over the center lamp as shown after maintenance or retrofitting.. Staple Suspended LED and Fluorescent 2