Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx.

Similar documents
.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

STANDBY 200 ekw 250 kva

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

Spark-Ignited Generator Set Model GGLA 60 Hz

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel generator set QSK50 series engine

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Diesel generator set 4BT3.3 series engine

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

STANDBY 200 ekw 250 kva

Generator Set Specifications 100 ekw (125 kva)

Spark-ignited generator set

DIESEL GENERATOR SET FEATURES

Spark-Ignited Generator Set Model GGFD 60 Hz

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENERATOR SET MTU 18V2000 DS1400

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

TECHNICAL OFFER. 1. CATERPILLAR PACKAGE OVERHAULED GENSET TYPE: C175-16, 2725KVA Prime Power, Build 2007, Original, Serial Number WYB00115, SMU 9725

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

DIESEL GENERATOR SET. 60 Hz FEATURES

Diesel Generator Set Model DFBF 60 Hz

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSX15 series engine

60 Hz FEATURES. Exclusively from your Caterpillar dealer

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel generator set 6BT5.9 series engine

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Diesel generator set QSK23 series engine

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Gaseous Fuel Generator Set Model GFDA

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Diesel generator set QSL9-G7 series engine

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Spark-ignited generator set

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel generator set QSB7 series engine

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Model DFEH 60 Hz EPA Emissions

PRIME 225 ekw 281 kva

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

Diesel generator set QSX15 series engine

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET MTU 16V2000 DS KVA

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET MTU 16V2000 DS1000

Generator Set Specifications 60 ekw (75 kva)

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Diesel Generator Set Model DFJD 60 Hz

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

XQ2000 SOUND ATTENUATED POWER MODULE

DIESEL GENERATOR SETS

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

Spark-Ignited Generator Set Model GGKC 60 Hz

DIESEL GENERATOR SET MTU 16V2000 DS1100

Rental Power QSB7 series engine

Diesel Generator Set Model DFHB 60 Hz

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

GENERAC GUARDIAN SERIES STANDBY GENERATORS

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Model DFHD 60 Hz EPA Emissions

Diesel Generator Set Model DFCE 60 Hz

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

Diesel generator set QSK23 series engine

Spark-Ignited Generator Set Model GGKD 60 Hz

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Standby kw Prime kw

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

Transcription:

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah 84047 (801) 566-5678 Ph. (801) 566-7745 Fx. New 850 kw Prime Power Natural Gas Generator Set Approval Status: Energetech s Packager is an Approved Supplier Pages of specifications received: Drawings received: none Addenda received: none Quotation is: As Per this Bill of Materials ENGINE MODEL:SP0850G:GUASCOR SFGLD 480 RATING: PRIME POWER POWER FACTOR: 0.8 KILOWATT/KVA: 850 KW D/C VOLTAGE: 24 VOLTS OVERLOAD: 10 % FUEL: GAS R.P.M: 1800 AMBIENT TEMP.: 40 C (104 F) PHASE: THREE PHASE ELEVATION: 700 ft A/C VOLTAGE: 480 FREQUENCY: 60 Hz Price: Please Call Delivery Date: 14-16 Weeks 1

Generator Model: SG1050 Rated 1050 kw, 480 V. Class H insulation (superior to class F) per NEMA MG1 22.4 and CSA standards Temperature rise: 125 degrees C rise in a 40 degrees C ambient - Thermistors embedded in stator windings, Permanent magnets in exciter Automatic Voltage Regulator: Voltage regulation +/- 1%. Three phase sustained short circuit current. Mounted in generator terminal box, c/w Integral voltage adjust rheostat, under an easy access cover for adjustments and maintenance. Engine Model: Guascor SFGLD 480 Heat rate: ~ 9400 Btu/kWh Features: Dress-up Guards for moving parts Oil drain valve with extension Engine mounted, Pusher fan CGA approved natural gas flex fuel lines Altronic CPU 95 ignition system Spark plugs Battery Cables Sufficient length for mounting battery next to genset skid, on the starter side. Skid Governor Heavy duty welded, structural steel Woodward Pro act 2 Series Digital Electronic Governor Block Heater 2 x 4000W Jacket water heaters, installed. AC Power by others. Isolators Lube Oil Ten (10) - RCA-60-3500 neoprene mounts with captive, seismic inserts First fill of engine manufacturer approved low ash oil Cooling System Radiator Heavy duty remote 2 circuit radiator with fan and motor starter, 180 F Jacket water thermostat & 130 F intercooler 50/50 Antifreeze (-37 degrees C or -34 degrees F nominal) Antifreeze supplied for engine radiator capacity only. Fuel Storage/Supply System Not included Gas pressure required is 3.5-5 PSI - Above pressure to be supplied by the customer The following is included: Gas pressure regulator Primary & Zero Gas pressure regulator Prechamber 2

Gas valves Main, Prechamber slow open type Gas valves Main by-pass slow open type Gas filters Genset Automatic Controller PRO 42-12 Features: * "Fault Reset" push button * Digital display (with back light): * AC frequency (Hz) * AC Volts * AC Amps * AC KWM * AC VARM * AC PFM * DC Volts * Running time hours * RPM Status Indicators: * Switch "Not in Auto"...... Amber (Steady Flashing) * "System Ready" (auto mode)...... Green (Steady Flashing) * Operational Status...... Green (Rapid Flashing) * "Emergency Stop" activated...... Red (Steady Flashing) * Shutdown active...... Overview Display Programmable timing functions - Factory Settings * Engine Start delay (adj 0 5 min)... 3 seconds * Overcrank delay (adj 0-4 min)... 75 seconds * Low oil pressure bypass delay (adj 0-255 sec)... 10 seconds * Cooldown timer (adj 0-255)... 5 minutes * Cycle crank (adj 0-30 sec)...... 3 of 15 sec * Rest time (adj 1-30 sec)...... 2 of 15 sec Alarm Annunciation - Digital Display * High engine temperature...... Shutdown * Overspeed...... Shutdown * Overcrank (fail to start)..... Shutdown * Low battery voltage..... Alarm * Low engine temperature...... Alarm * Low coolant level...... Shutdown * High engine temperature...... Pre-alarm * High battery voltage...... Alarm Annunciators/Miscellaneous Features: * Unit fail contact (10 amp) form C * Unit run contact (10 amp) form C Battery Charger 24 volts, 20 amps, 60 Hz Features included: - Automatic float and equalize - Completely solid state - On/Off switch with light - LED indication of equalize mode Unit mounted Labour (D/C wiring) 3

Battery Four (4) 8D-1100 (210 amp hr) batteries, c/w jumper cables Battery Racks Two (2) double 8D - Painted steel Muffler 14 inch Residential Grade, side inlet, end outlet Supplied loose Flexible Connection Corrugated, stainless steel, flexible connection * Supplied loose Circuit Breaker Not Included To be provided in switchgear. Enclosure Unit Color Labels No Enclosure Generator colour: Blue International Union of Operating Engineers CSA Approval, CSA C282 Preventative Maintenance warning Two (2) decals "Danger unit may start automatically" Factory Testing Factory Test One (1) hour at 100% load One (1) hour at 110% load - At unity power factor - Testing for load pickup and rejection Operating and Maintenance Manuals. - 2 Sets of O & M manuals shall be supplied. One installation manual shipped with the unit. Field Start-up Not included Outgoing Freight FOB Factory, offloading by others. Packing Warranty Pallet/Poly protection Earlier of 12 months after field start-up or 18 months after shipment date or 2000 hours of operation. Maintenance We would be happy to set up a maintenance contract with you to provide factory trained maintenance staff to your customer. 4

A. EXCLUSIONS: Field Installation Items: - Exhaust pipe, exhaust hangers, lagging, guards - Flanges, thimble, any material past the muffler, fuel - Primary regulator, Nat gas fuel train, utility fuel lines Other Exclusions: As outlined in the Bill of Materials B. CONDITIONS: - Standard Conditions of Sale apply, copy available upon request. - Prices are in U.S. funds. - Quotation is valid for thirty (30) days from date of issue. - Normal delivery, ex-factory, is 14-16 weeks after receipt of order, subject to availability. Please consult the factory for exact. - Purchase Order will not be processed unless accompanied by a firm 'Request for Delivery' date. This date cannot be altered after Purchase Order placed, unless agreed to in writing. - Supply scope limited to this Bill of Materials. Payment terms: (unless other arrangements have been set up) - 30% deposit with order - 15% on approval of shop drawings - 25% on completion of factory testing - 30% on ready for shipment C. NOTES: 1) Emissions on this engine is 1.5g NOx/bhp-hr 2) This engine control system has the unique capability to make the engine fuel mixture go from lean burn to transiently stoichiometric upon application of block load. This engine can offer 100% block loading. 3) This unit has one of the best ignition and governor systems available in the world today. 5