Entrematic Ditec Sprint 24V

Similar documents
Ditec SPRINT Swing doors drive unit

Ditec SPRINT Automation for swing doors

Ditec LUXO Swing gates automation (Original instruction)

Ditec BOX Balanced up and over doors

Ditec VALOR Sliding doors automation (Original instructions)

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Ditec CUBIC Swing gates automation

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Ditec DOD Industrial sectional door automations

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

Ditec VALOR HH-HS IP2063EN. Technical manual Sliding doors automation for hospitals and heavy sliding doors (Translation of the original instructions)

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

QIK4E-QIK7EH. Installation and maintenance manual for electromechanical barrier. (Translation of the original instructions) IP1861EN- rev.

Ditec E1A. IP2045EN Technical manual. Control panel installation manual for one motor automation with built-in radio.

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

Ditec PWR50H/HV/HR Automation for swing gates

Ditec PWR25H/35H Automation for hinged gates

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

IP2160EN. Ditec NeoS / NeoS+ Sliding Gates. Technical Manual. (Original instructions)

Rex. Manuale di installazione e manutenzione per porte scorrevoli. Installation and maintenance manual for sliding door

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

USER INSTRUCTIONS FOR SLIDING DOORS

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Cross14, Cross14E, Cross14VE, Cross15V

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

INSTRUCTIONS FOR INSTALLATION

EC DECLARATION OF CONFORMITY

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Automatic concealed bollards 275 H600 and 275 H800 Control station

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

BULL 424 ESA BULL 624 ESA

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

Installation Manual. Swing Gate System. Leading the way...

SLIDE NEW CONTROL BOARD

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

Ditec automatic pedestrian sliding doors.

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Automation Swing Gate Opener

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys.

Typical Installation Schematic

CE DECLARATION OF MACHINE CONFORMITY

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

FITTING AND CONNECTION INSTRUCTIONS

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

Automatic concealed bollards 275 H600 and 275 H800 with pit

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

BISON 20 OM BISON 25 OTI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Sectional and Tilting Door Opener

Mod: KLD6-12/35XLAS-N

BARRY BARRIER GATE AUTOMATION

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

FORCE SPD 800/1500/2000

ENG. Exeo. Revolving pedestrian door

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Cross Automations for sliding gates

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

QK SW80 V01_2011 USER MANUAL

c-go 24V/6A 24V/8A 24V/12A

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

Over Over Evo Over Heavy

Ditec PWR Automation system for swing gates with wings up to 5 metres

LINCE 300/400/600. User s and Intaller s manual

Porte 150 Users Manual Swing Gate Opener 24V DC

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

OPERATION & MAINTENANCE INSTRUCTIONS

Assembly and Maintenance Manual Type ASNU

Volo, Onda. Advanced entrance technology. Automation for curved sliding doors ENG

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

MP V 8A Electronic Smart Charger. Instruction and Information Manual

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Swing Piston Compressors and Vacuum Pumps

OPERATING AND USERS MANUAL

Everything becomes automatically more convenient! Discover the Ditec automation

Olly Dok. automations and motorized tracks for straight sliding frames

ISTRUCTION MANUAL Italian Movements Italian Movements

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Elmdene International Ltd

Sectional and Tilting Door Opener Installation Instructions and User Guide

OPERATION & MAINTENANCE INSTRUCTIONS

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

Declaration of Conformity

Transcription:

Foreløpig Brukerveiledning, vedlikeholdsog monteringsanvsing Entrematic Ditec Sprint 24V Ditec Sprint V Art.nr.: 2102200 Gewa AS Postboks 626 Trollåsveien 8 N-1411 KOLBOTN Tlf.: (+47) 66 99 60 00 Telefaks: (+47) 66 80 94 90 E-post: gewa@gewa.no Hjemmeside: www.gewa.no

Ditec Sprint Swing doors (Original instructions) IP1546 EN Technical Manual www.ditecentrematic.com

Index Subject Page 1. General safety precautions 3 2. Declaration of incorporation of partly completed machinery 4 2.1 Machinery Directive 4 3. Technical details 5 3.1 Operating instructions 5 3.2 Dimensions 6 4. Standard installation 7 5. Main components 8 6. Mechanical installation 9 6.1 Removing the cover 9 7. Installation with SBS sliding arm 10 8. Installation with SBA articulated arm 11 9. Installation with SPRINTBRAS 3-lever articulated arm 12 10. Installation of the floor doorstop 13 11. Electrical connections 14 11.1 Electrical connections for 230 V - 120 V power supply 14 11.2 Electrical connections for 24 V power supply 15 12. Connection of power supply 15 13. Commands 16 14. Outputs and accessories 16 14.1 Functions selector switch 17 15. Electromagnetic emissions 17 16. Adjustments 18 16.1 Trimmers enabling procedure 18 16.2 Signals 18 17. Doors requirements for disabled 19 18. Start-up 19 19. Troubleshooting 20 20. Routine maintenance plan 20 Operating instructions 21 General safety precautions 21 Manual release instructions 22 Caption This symbol indicates instructions or notes regarding safety issues which require particular attention. i This symbol indicates informations which are useful for correct product function. 2

1. General safety precautions Failure to observe the information in this manual may result in minor personal injury or damage to equipment. Save these instructions for future reference. This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with applicable regulations. Before installing the product, carefully read the instructions. Bad installation could be hazardous. The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as these are a potential source of hazard. Before installing the product, make sure it is in perfect condition. Do not install the product in an explosive environment and atmosphere: gas or inflammable fumes are a serious hazard risk. Before installing the motors, make all structural changes relating to safety clearances and protection or segregation of all areas where there is risk of being crushed, cut or dragged, and danger areas in general. Make sure the existing structure is up to standard in terms of strength and stability. The motor manufacturer is not responsible for failure to use Good Working Methods in building the frames to be motorized or for any deformation occurring during use. The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking into account: applicable laws and directives, Good Working Methods, installation premises, system operating logic and the forces developed by the motorized door. The safety devices must protect any areas where the risk exists of being crushed, cut or gragged, or where there are any other risks generated by the motorized door. Apply hazard area notices required by applicable regulations. Each installation must clearly show the identification details of the motorized door. When necessary, connect the motorized door to a reliable earth system made in accordance with applicable safety regulations. During installation, maintenance and repair, interrupt the power supply before opening the lid to access the electrical parts. The protective casing of the automation must be removed by qualified personnel only. To handle electronic parts, wear earthed antistatic conductive bracelets. The motor manufacturer declines all responsibility in the event of component parts being fitted that are not compatible with the safe an correct operation. For repairs or replacements of products only original spare parts must be used. The installer shall provide all information relating to automatic, manual and emergency operation of the motorized door, and provide the user with operating instructions. 3

2. Declaration of incorporation of partly completed machinery (Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden declares the automation for swing doors type Ditec SPRINT: has been constructed to be installed on a manual door to construct a machine pursuant to the Directive 2006/42/EC. The manufacturer of the motorized door shall declare conformity pursuant to the Directive 2006/42/EC (annex II-A), prior to the machine being put into service; conforms to applicable essential safety requirements indicated in annex I, chapter 1 of the Directive 2006/42/EC; conforms to the Low Voltage Directive 2006/95/EC; conforms to the Electromagnetic Compatibility Directive 2004/108/EC; technical documentation conforms to Annex VII-B to the Directive 2006/42/EC; technical documentation is managed by Marco Pietro Zini with offices in Via Mons. Banfi, 3-21042 Caronno Pertusella (VA) - ITALY; a copy of technical documentation will be provided to national competent authorities, following a suitably justified request. Landskrona, 15-01-2013 Marco PietroZini (President & CEO) 2.1 Machinery Directive Pursuant to Machinery Directive (2006/42/EC) the installer who motorizes a door or gate has the same obligations as the manufacturer of machinery and as such must: prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive; (The technical file must be kept and placed at the disposal of competent national authorities for at least ten years from the date of manufacture of the motorized door); draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Directive and deliver it to the customer; affix the EC marking on the motorized door in accordance with point 1.7.3 of Annex I of the Machinery Directive. 4

3. Technical details Power supply 230 V~ 50/60 Hz SPRINT PN SPRINT P SPRINT V SPRINT LN SPRINT L SPRINT LV 24 V (to protect with external fuse) 120 V~ 60 Hz Absorption 0.5 A 3 A 1 A Power consumption 120 W 120 W 120 W Torque 25 Nm 25 Nm 25 Nm Insulation class Class 2 / Class 2 Opening time Closing time min 3 s /90 max 6 s /90 min 4 s /90 max 7 s /90 min 3 s /90 max 6 s /90 min 4 s /90 max 7 s /90 min 3 s /90 max 6 s /90 min 4 s /90 max 7 s /90 SPRINT PNJ SPRINT VJ Service class 5 - VERY INTENSE 5 - VERY INTENSE 5 - VERY INTENSE Intermittence S3=80% S3=80% S3=80% Operation type Motor opening Motor closing Motor opening Motor closing Motor opening Motor closing Maximum load (1 m wing) 100 kg 100 kg 100 kg Maximum load (1.2 m wing) 80 kg 80 kg 80 kg Temperature min -20 C max +55 C min -20 C max +55 C min -20 C max +55 C Temperature with batteries min -10 C max +50 C min -10 C max +50 C min -10 C max +50 C Degree of protection IP30 IP30 IP30 Control panel EL38 EL38 EL38 Feeder AL05 / AL05J F1 fuse F1A / F2A Motor power supply 24 V 3,5 A 24 V 3,5 A 24 V 3,5 A Accessories power supply 24 V 0,3 A 24 V 0,3 A 24 V 0,3 A Operating instructions 3 4 5 Recommended dimensions Limit dimensions Limit speed Door wing weight [kg] 150 100 50 Motor speed adjustment VM 2 1 7 6 5 4 3 2 1 6 7 0 0.5 1 1.5 0 10 20 30 40 50 60 70 80 90 100 3.1 Operating instructions Door wing width [m] Wing weight [kg] Service class: 5 (minimum 5 years of working life with 600 cycles per day). Applications: VERY INTENSE (for shared entrances with very intense pedestrian use). Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of maximum permissible weight). When used with the maximum permissible weight a reduction in the above mentioned performance can be expected. Service class and the number of consecutive cycles are to be taken as merely indicative Having been statistically determined under average operating conditions, and are therefore not necessarily applicable to specifi c conditions of use. Each automatic entrance has variable elements such as: friction, balancing and environmental factors, all of which may substantially alter the performance characteristics of the automatic entrance or curtail its working life or parts thereof (including the automatic devices themselves). The installer should adopt suitable safety conditions for each particular installation. C F M A 5

3.2 Dimensions 93 450 91 450 79 79 445 7,5 60 111 149 168 75 8,5 i NOTE: unless otherwise specified, all measurements are expressed in millimetres (mm). 6

4. Standard installation 5 1 2 6 7 A 6 4 3 i Ref. Code Description 1 SPRINT Drive unit 2 SBA SBS SPRINTBRAS FBA Articulated arm Sliding arm 3-lever articulated arm Doorstop for articulated arm 3 Floor doorstop 4 COMH Function selector switch COMK 5 SPRINTBAT Battery kit 6 PASM24W (microwave), or PASM243 (microwave), or PASS24 (microwave), or PASS24W (microwave), or Opening sensor PAY ATTENTION TO FIXING POSITION PASA (infrared) REM35 Safety sensor during opening and closing REM90 REM100 A Connect the power supply to an approved omnipolar switch with an opening distance of the contacts of at least 3mm (not supplied). The connection to the mains must be made via an independent channel, separated from the connections to command and safety devices. NOTE: the given operating and performance features can only be guaranteed with the use of DITEC Entrematic accessories and safety devices. 7

5. Main components 4 1 3 2 7 8 9 6 5 Ref. Code Description 1 24 V motor with encoder 2 EL38 Control panel 3 SPRINTBAT Battery kit 4 Base plate 5 Switching on and off switch 6 Function selector switch 7 Arms support 8 Aluminium casing [SPRINT V-SPRINT LV-SPRINT VJ] 9 Grey plastic casing [SPRINTP-SPRINT L] Black plastic casing [SPRINT PN-SPRINT LN-SPRINT PNJ] 8

6. Mechanical installation Check the stability, the weight of the door wing and the regularity of the movement, without friction (if necessary reinforce the frame). Any door check must be eliminated or completely cancelled. Attention: check the correct working in the case of installation on doors that separate environments with different pressures. 6.1 Removing the cover 1 2 9

7. Installation with SBS sliding arm DP x8 34 D 500 150 29 max 45 min 650 OPENING F G B A E C F Use the SBS sliding arm for doors which open inward (view from automation side). Remove the casing and fasten the automation on the wall, where indicates (P) securely and make sure it is level, respecting the measurements indicated in the figure: refer to the hinge axis. Bore the guide [A] and fasten it to the door. Insert the sliding block [B] of the sliding arm in the guide [A]. Fasten the arm [C] to the automation, ensuring it is inserted in the housing of the arm support [D]. Insert the lid [E] and the two heads [F]. Adjust the inner stop [G] to the most suitable position. 10

8. Installation with SBA articulated arm max 30 DP x8 44 B C 46 320 min 550 max 300 OPENING C A A 90-100 min 10 Use the SBA articulated arm for doors that open outward (view from automation side). Remove the casing and fasten the automation on the wall, where indicates (P) securely and make sure it is level, respecting the measurements indicated in the figure: refer to the hinge axis. Assemble the articulated arm, without tightening the sliding screws [A], and fasten it to the automation, ensuring it is inserted in the housing of the arm support [B]. Fasten the bracket [C] to the door. With the door closed, adjust the arm and tighten the sliding screws [A]. 11

9. Installation with SPRINTBRAS 3-lever articulated arm DP x8 C 1 D 74 34 D A 340 225 max 185 A B min 650 OPENING C D E 34 2 D B max 45 A A OPENING 1 2 80-90 min 395 80-90 min 220 Use the SPRINTBRAS 3-lever articulated arm for doors which open inward (view from automation side). Remove the casing and fasten the automation on the wall, where indicates (P) securely and make sure it is level, respecting the measurements indicated in the figure: refer to the hinge axis. WARNING: the fixing distance of the automation in relation to the door wing can be included between 185 mm and 45 mm. Adjust the length of the bracket [A] and arm [B] so as to form an angle of 80 90 in relation to the arm [C], with the door closed. Note: the SPRINTBRAS articulated arm is assembled for door wings with left-hand opening; in case of door wings with righthand opening, separate the arm [D] from the arm [C] by removing the plug [E] and reassemble the two arms by rotating them by 180. For distances between 45 mm and 20 mm, remove the arm [B] and fasten the arm [D] directly to the bracket [A] with the spacer and the screw supplied, so as to form an angle of 80 90 in relation to the arm [C]. 12

10. Installation of the floor doorstop Fasten to the floor the floor doorstop as a mechanical stop in opening. 13

11. Electrical connections 11.1 Electrical connections for 230 V~ - 120 V~ power supply AL05 (230 V~) AL05J (120 V~) F1 N L Power supply Motor 24V + - +R -LK+ X + Electric lock output - 12 V max 1.2 A +M- ENC VM TC ON OFF 1 2 3 4 5 6 COM IN SA POWER ALARM OPEN - + +R SWITCH G1 0 1 1 2 3 8 9 SPRINTBAT ON-OFF switch Stop Closing safety contact Opening Automatic closing + Output 24 V max 0.3 A - General purpose X indicates where to install supplied ferrites as shown in figure The figure shows the main connections of the control panel EL38. 14

11.2 Electrical connections for 24 power supply (to protect with external fuse) Motor 24V -LK+ X + Electric lock output - 12 V max 1.2 A +M- ENC VM TC COM ON IN SA OFF 1 2 3 4 5 6 POWER ALARM OPEN SWITCH G1 0 1 1 2 3 8 9 - + +R Power supply ON-OFF switch Stop Closing safety contact Opening Automatic closing + Output 24 V max 0.3 A - General purpose X indicates where to install supplied ferrites as shown in figure 12. Connection of power supply Before connecting the power supply, make sure the plate data correspond to that of the mains power supply. An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply. Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout. Use a H05RN-F 2G1,5 or H05RR-F 2G1,5 type electric cable and connect to the terminals L (brown), N (blue) in the automation. Secure the cable using the special cable clamp and remove the outer sheath near the terminal only. Connection to the mains power supply, in the section outside the automation, is made with independent channels and separated from the connections to the control and safety devices. Make sure there are no sharp edges that may damage the power supply cable. Make sure that the mains power supply (230 V) conductors and the accessory power supply (24 V) conductors are separate. 15

13. Commands Command Function Description 1 2 N.O. CLOSING The closing of the contact activates the closing operation. AUTOMATIC A permanent contact enables automatic closing. CLOSING 1 3 N.O. OPENING The closing of the contact activates the opening operation. 1 8 N.C. CLOSING SAFETY The opening of the contact reverses movement (re-opening) during the closing operation. CONTACT 1 9 N.C. STOP The opening of the contact stop all movements and excludes all normal or emergency operations. OPEN N.O. OPENING The opening operation is activated with a brief press. WARNING: make a jumper for all the N.C. contacts if not in use. The terminals with the same number are equal. 14. Outputs and accessories Output Value - Accessories Description 0 1 - + -LK+ G1 0 + - SWITCH COM MOT + - ENC 24 V 0.3 A 12 V 1.2 A 24 V 30 ma Accessories power supply. Power supply output for external accessories. NOTE: the maximum absorption of 0.3 A corresponds to the sum of all terminals 1. Electric lock. Output for electric lock or electric block. The electric lock power supply has an advance of 0.1 seconds and a duration of 1 second. General Purpose Output. The output provides a positive of 30 ma whose function can be determined using the COM customisation module. ON-OFF switch. Switch for activating/deactivating the power supply. When activating (ON), the first operation is carried out with the acquisition of the stop positions. When deactivating (OFF), the line power supply and the batteries (if present) are disconnected from the control panel. WARNING: make a jumper if not in use. It allows the functioning configurations to be saved or the control panel application type to be defined. WARNING: the module must be inserted and removed with the power supply disconnected. Motor-encoder connection. Connect the motor and encoder to the control panel by means of the supplied cables. SPRINTBAT 1 x 12 V 1,2 Ah Anti-panic battery kit. With the mains power supply off, the automation will carry out an opening operation at low speed. When the door is open, the power supply is disconnected from the control panel. To charge the batteries, connect the mains power and the battery kit at least 30 minutes before starting the system. WARNING: the batteries must always be connected to the control panel for charging. Periodically check the efficiency of the batteries. Continuous mode battery kit. With the mains power supply off, the battery kit will guarantee continuous operating. To charge the batteries, connect the mains power and the battery kit at least 30 minutes before starting the system. WARNING: the batteries must always be connected to the control panel for charging. Periodically check the efficiency of the batteries. 16

14.1 Funtion selector switch SPRINTV LEFT SIDE RIGHT SIDE Radar B 24 V + - Radar A 24 V + - G1 0 1 1 2 3 8 9 CONTROL PANEL Rif. Description Door open. 1-3 permanent opening command. Door closed. Radar controls (A-3) are excluded. The door can be opened by control 1-3A or by pushing if the Push&Go function is enabled. Automatic door closing (1-2 contact). Bi-directional operating mode. 15. Electromagnetic emissions WARNING: in accordance with Directive 2004/108/EC, the supplied ferrites must be installed as shown on page 14-15. Pass the cable through the ferrite, make 1 turn and protect it from knocks by using heat-shrink sheathing or similar. The ferrite must be secured to the cable near the terminal boards (approximately 50 mm). 17

16. Adjustments Description DIP1 DIP2 Doors with no electric lock and subject to strong winds. If the wind blows the door open, a closing force is triggered by the motor. OFF OFF Doors with electric lock. When the door is closed a closing force is maintained by the motor. OFF ON Push&Go doors without electric lock. Manual pushing of the door activates automatic opening. When the door is closed a closing force is maintained by the motor. ON OFF Push&Go doors with electric lock. Manual pushing of the door activates automatic opening. When the door is closed a closing force is maintained by the motor. ON ON DIP3 DIP4 Description OFF ON LowEnergy function. Disabled. Enabled. Refer to chapter Doors requirements for disabled on page 21. Opening direction selection. SEE FIGURE SEE FIGURE The opening direction is intended by viewing the automation from the side being examined. DIP5 Arm type selection. SBA articulated arm. SEE FIGURE SBS sliding arm SPRINTBRAS articulated arm. SEE FIGURE DIP6 FUTURE USE - - SBA Arm DIP4 DIP5 SBS - BRAS Arm DIP4 DIP5 ON OFF OFF ON OFF OFF ON ON 16.1 Trimmer enabling procedure The VM and TC trimmers affect the force limiting safety function. They must be set as instructed. If not, the modifications will not be accepted and the IN LED will flash. press the OPEN key for 4 s (IN LED flashes); set the VA, VC and R1 trimmers within a maximum time of 5 min; to complete the procedure, press the OPEN key for 2 s or wait for the maximum time to expire. min Trimmer VM max 0 s 30 s TC Description Operation speed adjustment. Adjusts the automation operation speed. The closing speed equal to 2/3 of the opening speed. WARNING: set the correct operation speed and check that the operating force and contact force between the door wing and the obstacle is lower than that indicated in the EN 16005 standard. Setting automatic closing time. Adjust the time that passes between the end of the opening operation and the start of the automatic closing operation. 16.2 Signals LED IN SA POWER ALARM Description On Flashing Receipt of a command 1-3. Change in status of a dip switch or command 1-2. Trimmer enabling procedure in progress. At least one of the safety contacts is open. - Power supply on. Encoder not working or automation fault. 18

17. Doors requirements for disabled If the Ditec SPRINT automation is used on doors for the passage of disabled, adjust the VM trimmer so that the opening and closing times (excluding deceleration) are the same as, or greater than, those indicated in the table. Door wing weight [kg] 50 60 70 80 90 Door wing length [mm] 1200 1000 850 750 3,0 s 3,0 s 3,0 s 3,0 s 3,5 s 3,0 s 3,0 s 3,5 s 3,5 s 4,0 s 3,5 s 3,5 s 4,0 s 4,0 s 4,5 s 4,0 s 4,5 s 4,5 s 5,0 s 5,5 s Make the adjustments indicated in the figure: t 3 s t 4 s ~80 t 3 s min 10 OPENING 5 s TC t 1,5 s CLOSING 18. Start-up WARNING: Before performing any type of operation, make sure that the automation is turned off and the batteries are disconnected. The operations in point 4 are performed without safety devices. The trimmer can only be adjusted with the automation idle. 1- Select the operating force with DIP3 e select the correct opening direction with DIP4. Set DIP1 and DIP2 according to the type of installation. 2- Set TC trimmer to the minimum and VM trimmer halfway. 3- Make a jumper on the safety devices (1-8) and the stop (1-9). 4- Turn on the power (mains and batteries). Warning: the control panel performs an automatic POWER RESET on each start and the first opening or closing manoeuvre is performed at low speed allowing the automatic self-learning of the stop positions (acquisition). Check that the automation is operating correctly with further opening and closing commands and set the desired speed using the VM trimmer. WARNING: to set the VM and TC trimmers, the trimmers must be enabled as described on page 20. 5- Remove the jumpers and connect the safety devices (1-8) and the stop (1-9). 6- Adjust the automatic closing with the TC trimmer (enabled by command 1-2). 7- Set the Push&Go opening using DIP1 if required. 8- Connect any accessories and check they operate correctly. 9- If the automation encounters an obstacle during a closing operation, the movement is reversed. If the automation encounters an obstacle during an opening operation, movement is stopped. If the obstacle is detected twice consecutively, it is considered as the new stop until it is removed. i Warning: check the operating force and that the contact force between the door and the obstacle is lower than that indicated by the EN 16005 standard. NOTE: in the event of servicing or if the control panel is to be replaced, repeat the start-up procedure. 19

19. Troubleshooting Problem Possible causes Remedy The automation does not No power. Check that the control panel is powered correctly. open or close. (POWER ALARM led off). The automation opens by itself. The automation opens/closes briefly and then stops. Short circuited accessories. (POWER ALARM led off). Blown line fuse. (POWER ALARM led off). The stop contact is open. The automation is locked by bolts and locks. Safety contacts are open. (SA led on). Safety devices are activated. (SA led on). The radars are activated. The automatic closing does not work. The radars are instable or detect moving objects. Encoder disconnected, false encoder contacts, encoder fault. (POWER ALARM led flashing). Motor leads crossed. (POWER ALARM led flashing). There is a presence of friction. Disconnect all accessories from terminals 0-1 (voltage must be 24 V ) and reconnect one at a time. Replace F1 fuse. Check terminal 9 of the control panel and the position of the function selector switch (if present). Check that the door wings move freely. Check terminal 8 of the control panel. Check that the safety devices are clean and operating correctly. Check that the radar is not subjected to vibrations, does not make false readings or the presence of moving objects within its range. Check jumper 1-2 and the position of the function selector (if present). Check that the radar is not subjected to vibrations, does not make false readings or the presence of moving objects within its range. Check that the encoder is connected correctly, clean the contacts by connecting and disconnecting the encoder plug on the contacts, replace encoder. Check the motor leads. Manually check that the door wings move freely and adjust the door wing in height by lifting it. 20. Routine maintenance plan Perform the following operations and checks every 6 months according to intensity of use of the automation. Disconnect the 230 V~ power supply and batteries (if present) and turn the ON-OFF switch OFF: Clean and lubricate the moving components. Check that all securing screws are well tightened. Check all the electrical connections. Check battery efficiency. Reconnect the 230 V~ power supply and batteries (if present) and turn the ON-OFF switch ON: Check the stability of the door and that the movement is regular and without friction. Check the condition of the pintles or hinges. Check that all control and safety functions are working correctly. i i NOTE: for spare parts, see the spares price list. For repairs or replacements of products only original spare parts must be used. The installer shall provide all information relating to automatic, manual and emergency operation of the motorised door or gate, and provide the user with operating instructions. The installer must prepare the maintenance log, which will indicate all the interventions of ordinary and extraordinary maintenance carried out. 20

Operating instructions Ditec SPRINT Swing doors General safety precautions DETACH AND DELIVER TO THE CUSTOMER The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed. Any other use is to be considered improper and therefore dangerous. The manufacturer cannot be held responsible for any damage caused by improper, incorrect or unreasonable use. This product should not be used by people (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety. Avoid operating in the proximity of the hinges or moving mechanical parts. Do not enter within the operating range of the motorized door while it is moving. Do not block the movement of the motorized door since this may be dangerous. Do not allow children to play or stay within the operating range of the motorized door. Keep remote controls and/or any other control devices out of the reach of children in order to avoid possible involuntary activation of the motorized door. In the event of fault or malfunctioning of the product, turn off the power supply switch, do not attempt to repair or intervene directly and contact only qualified personnel. Failure to comply with the above may cause a dangerous situation. All cleaning, maintenance or repair work must be carried out by qualified personnel. To ensure that the system works efficiently and correctly, the manufacturer s indications must be complied with and routine maintenance of the motorized door must be performed by qualified personnel. In particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. For the correct disposal of electric and electronic equipment, waste batteries and accumulators, the user must take such products to the designated municipal collection facilities. Technical data Power supply 230 V~ 50/60 Hz SPRINT PN SPRINT P SPRINT V SPRINT LN SPRINT L SPRINT LV 24 V (to protect with external fuse) 21 120 V~ 60 Hz SPRINT PNJ SPRINT VJ Rated power input 120 W 120 W 120 W Service life 5 - VERY INTENSE 5 - VERY INTENSE 5 - VERY INTENSE Temperature min -20 C max +55 C min -20 C max +55 C min -20 C max +55 C Temperature with batteries min -10 C max +50 C min -10 C max +50 C min -10 C max +50 C Degree of protection IP30 IP30 IP30 Control panel EL38 EL38 EL38 Line fuse F1A / F2A Accessories power supply 24 V 0,3 A 24 V 0,3 A 24 V 0,3 A

Manual release instructions POWER OFF In the event of maintenance, malfunctioning or emergency, to disconnect the automation power supply, set the ON-OFF switch to OFF and move the door manually. If the door does not have an electric lock, use the appropriate key to release it. Warning: carry out the door wing blocking and release with the motor switched off. The following safety devices may be installed to protect the danger areas (according to EN 16005): 2 1 1 1 2 PASM24W (microwave), or PASM243 (microwave), or PASS24 (microwave), or PASS24W (microwave), or PASA (infrared) REM35 REM90 REM100 Opening sensor Safety sensor during opening and closing DETACH AND DELIVER TO THE CUSTOMER i For repairs or replacements of products only original spare parts must be used. The installer shall provide all information relating to automatic, manual and emergency operation of the motorised door or gate, and provide the user with operating instructions. 22

All rights related to this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been compiled with the greatest possible care, Entrematic Group AB cannot accept liability for any damage that might arise from errors or omissions in this publication. We reserve the right to make modifications without prior notice. No part of this publication may be copied, scanned, adapted or modified without prior permission in writing from Entrematic Group AB. 23

Entrematic Italy S.p.A. Via V. Pisani, 20 20124 Milano (MI) ITALIA Tel. +39 02 963911 Fax +39 02 9650314 www.ditecentrematic.com