BATTERY CHARGERS.

Similar documents
M Technical Specification No. for the supply of Battery Charger. Israel Railways Ltd. Rolling Stock Division

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

POWER kva

Technical Data Sheets

Technical Data Sheets

POWER kva

TECHNICAL DATA SHEET KVA UPS Systemss

Qingdao Zener Electric Co., Ltd

THE DLS SERIES BATTERY CHARGING POWER CONVERSION

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

EMERGENCY VEHICLE BATTERY MANAGER PS2024

All In one uninterruptible power supply solutions

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Technical Data Sheets

Magellan Utility Scale Energy Storage

User Manual Solar Charge Controller 3KW

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

MKN-DSP SERIES - THREE PHASE

TLE Series UPS 400/500 kw With eboost Technology

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

RVS-DN Digital Reduced Voltage Motor Starter

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

TLE Series UPS 160/200/225/250 kw with eboost Technology

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

RVS-DX Digital Reduced Voltage Motor Starter

SPECIFICATIONS LOW COST 2404R CHARGER

EFFEKTA Power Supplies

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Three Phase UPS Systems Range: 10 to 500kVA

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

User Manual. Solar Charge Controller 3KW

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

SPECIFICATIONS SRL CHARGER

Amperis battery regenerator

R series solar charger inverter 1000W to 6000W

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications


Illuminator Series CR NEMA 3R

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

AT EVO SERIES BATTERY CHARGER

Liebert. FP 50Z kva

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

Supply, testing, installation and commissioning of 5 ky A UPS system as per the following specification:

AT30 SERIES BATTERY CHARGER

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Industrial Chargers and

MD60 Series 60W DINergy Power Supply

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

.3 Section Waste Management and Disposal.

SPECIFICATIONS SRF

SPECIFICATIONS SRF SuperchargerPlus

Features. Description. Table of Contents

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

LS200 Series Instruction Manual

TLE Series UPS 750/1000 kw With eboost Technology

USER S MANUAL SOLAR POWER INVERTER KW-6KW

Alphapower HTU UPS. Some key features include:

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Astron Power Supplies

SPECIFICATIONS LOW COST 2404S CHARGER

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

SPECIFICATIONS SR

Onfiniti. 1 Phase UPS

Solar Controller / Battery Charger User s Manual

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Technical Data Sheets

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

INTELLI-CHARGE BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheets

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

CBI All in One DC UPS Power Solutions

SPECIFICATIONS SR CHARGER

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

SPECIFICATIONS SRM10 24V 0.5A MEDICAL CHARGER

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Marketing Management Team of Europe

EVO AT SERIES BATTERY CHARGER

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

SAVER DSP SERIES. 3-10kVA USER MANUAL

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500

Technical data sheets

Transcription:

BATTERY CHARGERS Battery Charging Batteries used on rolling stock are either lead acid or nickel cadmium. Both types are available in sealed form so that water or gel does not need to be added. Batteries on diesel driven cars (DMUs) are used to start the engines and supply power for the switch gear and air conditioning on the car. On electric trains, batteries are used to power the pantograph gear to connect the train to the overhead wires and can also act as a backup power supply. Train batteries are typically large and expensive and require special care when charging so they last longer. Consequently, charging these batteries is more complex than you may expect. Basic Battery Charging Method - Float Charging Most basic battery chargers use a method known as Float Charging. A fixed charging voltage is set, higher than the open circuit voltage but slightly lower than the gassing voltage. In certain circumstances this can be satisfactory but generally it is not preferable because this does not give optimum performance of the batteries and reduces their effective life. Optimum Battery Charging Algorithm The optimum battery charging algorithm is summarised below. Keeping to this algorithm will extend the life of the batteries to the maximum possible. This applies to batteries in constant use as well as those kept in storage. During the charging mode of operation the batteries should be charged according to the optimum charging profile shown in Figure 1. Constant current charging Constant voltage charging Trickle charging I V 5 h 6 h 8 h Figure 1: Optimum Charging Profile Time

There are four modes of operation during optimum charging. 1. Constant Current Charging During the first period of charging (which would typically last 5 hours) the batteries are charged at a constant current of 15.5% of their Amp-hour rating. The battery voltage increases and at the end of this cycle the batteries reach their gassing voltage. At this point the battery charging mode switches to constant voltage. 2. Constant Voltage Charging The second period of charging (typically lasting an hour) commences when the DC link voltage reaches 2.4 volts/cell, and the batteries are charged at a constant voltage. The current drops away exponentially. When the charging current reduces to the trickle charge level, the battery charging mode switches to trickle charge. 3. Trickle Charging When the current drops to 3.5% of the Amp-hour rating, the batteries are once again charged at a constant current, but at the reduced charging rate. 4. Battery Charged When the rate of change of DC link voltage drops below 1% of the nominal voltage per half-hour, the batteries are fully charged and charging is complete. The optimum charging profile is that specified by British Standards, IEC Standards and Australian Standards, AS2402. Battery Equalising Over time, depending on how the battery is used, sulphate crystals can accumulate within the battery and harden to form insulation. This is called Sulfation. Such sulphur accumulation reduces the effective surface area of the cell plates and thus reduces battery charge capacity and battery life. Another condition known as stratification is where different concentrations of acid form layers within the battery liquid leading to uneven charging and reduced battery life. Battery Equalising is a method of charging a battery at a higher voltage, producing gassing, but at a limited current. This function dissolves much of the accumulated sulphur and mixes the battery solution thus extending battery life. Gel type batteries do not require equalising. Temperature Considerations The temperature of a battery has an effect on the amount of charge a battery accepts and the rate at which it will accept the charge. Advanced battery charging systems measure the battery temperature and adjust charging voltage and current accordingly. SCHAFFLER Battery Chargers SCHAFFLER Battery Chargers are designed taking into account the specific circumstances effecting battery charging in combination with the rugged requirements of railways. These factors include: Type of battery Typical and peak battery usage Required charging method Voltage, Current and Power constraints EMI and audible noise Shock and vibration Fault protection and redundancy All locomotives are different and have specific requirements, however the basic principles of battery charging and care remain. SCHAFFLER have great experience in battery charger design. SCHAFFLER Battery Chargers protect investment in battery systems by maximising battery life.

Typical Specification for 24Vdc Battery Charger Power rating 4, 6 and 8 kw 150 amp, 220 amp and 300 amp Optional power rating 12 and 18 kw Part No. #ac supply-hbc8000-24-#kws Supply voltage Design structure 380 / 415 / 480 volts 3-phase 30 to 70 Hz. Battery charger will accept 320 to 525 Vac 3-phase or 376 to 700 Vdc IGBT phase shifted full bridge Power factor Phase rotation Inrush current Output current ramp up time Nominal battery voltage Charging battery voltage Battery over voltage shutdown Charging Algorithm Equalising voltage Battery charging current Static Output Voltage droop Battery temperature control Temperature compensation Temperature probe inputs Ripple voltage maximum Efficiency Ambient temperature Active circuit Overload Signal outputs at control plug RS485 serial port LCD display >0.92 for >50% output load Insensitive to phase rotation <20 amps peak at 400 VAC input 10 seconds to maximum current 24 Vdc 27.6 Vdc. (Voltage range 24 to 32 Vdc) 36 Vdc Constant current; Constant voltage; Trickle charger 24 to 32 Vdc Separate current control up to 60 amps in constant current mode, switching to constant voltage mode, switching to trickle charge. Remainder of current available for the standing load 0.30 Vdc ±0.05 Vdc from 0 to full load. Charging current reduced as temperature of batteries increase above 40ºC. Current reduces proportionally to zero as battery temperature approaches 65 ºC 0 to -50 mv/ ºC 2 X PT100 inputs (2 or 4 wire) 2 X LM335/AD592 probes < 0.5 volts peak to peak at 6 khz Output DC filter will be provided 92% Peak current mode detection used to prevent saturation in isolation transformer -25 to 60 º C No connection to earth 100% and current limited 4-20 ma proportional to charging voltage 4-20 ma proportional to charging current N/O Fault contacts available Two wire isolated supporting Modbus protocol Optional access for modifying charging algorithm. Optional access to status and fault log. Optional backlit LCD display visible through front window. LCD to display: Charging voltage, Charging current, State of charging, Constant current, Constant voltage, Float charge, Battery temperature, Fault status

Mounting location Protection Weight External connections Voltage surges; lightning Within vestibule or optional under frame mounting IP21 internally forced ventilated Or IP65 totally enclosed Forced ventilated battery chargers 35 kg Underframe IP65 battery chargers 61 kg Three military style plugs including mating cable plugs. 3-phase supply input 24 VDC output and Data Control Control connections Differential mode 2.6 kvp Common mode 1.3 kvp for 100 µsec Waveform 1.2/50 µsec Protective Features I x t overload protection Instantaneous over-current protection 150% Output short circuit protection Earth Fault Under voltage Battery charger over temperature Battery over temperature 6kW 300 amp 27.6 Vdc Battery Charger IP67 self ventilated 8kW 300 amp 27.6 Vdc Battery Charger IP67 self ventilated 6kW 220 amp 27.6 Vdc Battery Charger IP23 forced ventilated

Typical Specification for 74 Vdc or 110 Vdc Battery Charger Supply voltage 380 / 415 / 480 volts 3-phase 30 to 70 Hz. Battery charger will accept 320 to 525 Vac 3-phase or 376 to 700 Vdc Nominal battery voltage 72 or 110 Vdc Charging battery voltage Adjustable in software Maximum output current Efficiency Isolation Ripple voltage maximum Active circuit Start up load Overload Signal outputs at control plug Display Ambient temperature Protection External connections Voltage surges; lightning Weight Protective Features Ixt overload protection, 10 to 100% Instantaneous over-current protection 15 to 150% Output short circuit Earth Fault External trip circuit 100 amps modules Battery charging is reduced when battery temperature rises above 40ºC and stops at 60ºC. Battery output is separate to the standing load output 92% at 40% load Secondary fully isolated from input supply < 0.5 volts peak to peak at 6 khz Output DC filter will be provided No connection to earth Equal to steady state load 100% and current limited Normally open contacts rated at 5 amps at 110 VDC intended for the train management system 0-10 VDC proportional to charging voltage 0-10 VDC proportional to charging current RS485 serial port Optional digital display visible through a window -40 to 55º C (within the locker) IP65 self-ventilated or IP54 blower with IP56 electronics One military style plugs including mating cable plugs. 3-phase 415 supply input 74 Vdc or 110 Vdc output Differential mode 2.6 kvp Common mode 1.3 kvp for 100 µsec Waveform 1.2/50 µsec 61 kg per 100 amp module IP65 self-ventilated 35 kg per 100 amp module IP54 blower with IP56 electronics Hardware fault coding Diagnostic display Over voltage Under voltage Over temperature heat sink Over temperature ambient Thermistor input facility Optional features Algorithm controlled battery charger. This includes constant voltage charging until gassing is reached, followed by constant current charging until trickle charge is reached, followed by trickle charge for a time period. Each of these set points is available for adjustment.

100 amp 74 Vdc Battery Charger IP65 self-ventilated 100 amp 74 Vdc Battery Charger IP65 self-ventilated Xplorer/EndeavourBattery Chargers Xplorer/Endeavor trains are DMUs that run in the outer metropolitan areas of Sydney, NSW. The battery chargers on these trains are of the basic charging type. 24V batteries are charged at a constant 27.6V whilst the current is measured. When the charging current reduces to a preprogrammed level then charging ceases. VLocity Battery Chargers The VLocity trains are DMUs that run in the outer metropolitan and country areas of Melbourne, VIC. The battery chargers on these trains follow the optimum charging algorithm and output 250Amps. Hunter Battery Chargers The Hunter trains are DMUs that run in the Hunter Valley in NSW. The battery chargers on these trains follow the optimum charging algorithm and output 500Amps. These chargers are installed as a master/slave pair and provide 100% redundancy. M E M B E R